Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC MISRA ELECTROSTATE CENTRE BAR ASSOCIATION COMPOUND CIVIL COURT AYODHYA 224123 UP | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | L1 | Accepted-AOC Tender Accepted | |
| 2 | L2₹22.5 L+₹1.3 L (6.20%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹23.0 L+₹1.8 L (8.51%)Rejected-Finance 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹23.0 L+₹1.8 L (8.64%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹23.5 L+₹2.3 L (10.8%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
1 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faizabad
GE mes Faizabad
REPAIR MAINT OF LT OVERHEAD LINES POLE ISINSULATORS AND ALLIED WORKS UNDER AGE EM AT FAIZABAD
2022_MES_523329_1
8303/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Faizabad
₹60,000
Yes
5 Jul 2022
11 May 2022
2 Jun 2022
11 May 2022
1 Jun 2022
18 May 2022
90 days
Amount
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil, complete all as specified .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soil, complete all as specified .
Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point , complete all as specified .
M & L for fine sand cushioning to underground cable with clean dry river sand , complete all as specified . Note:- Punned thickness only shall be measured & Paid.
Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable , complete all as specified .
M & L for plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation of poles, complete all as specified .
M & L for plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation of stay assembly struts etc , complete all as specified .
M & L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles including necessary form work , complete all as specified .
Hiring of cable fault detector, to detect exact position of fault for XLPE /PVC LT/HT cable, 1100/11000 Volts grade heavy duty aluminium conductor of any size including to and fro transporting charges etc. , complete all as specified .
S & F Straight through cable joint kit for LT UG cable of SIZE 16 Sqmm 4 Core , complete all as specified .
All as per item no. 10 but 25 to 50 Sqmm 3.5 Core
All as per item no. 10 but 70 to 120 Sqmm 3.5 Core
All as per item no. 10 but 150 to 185 Sqmm 3.5 Core
All as per item no. 10 but 240 to 300 Sqmm 3.5 Core
Horizontal boring in soft/loose soil/under roads of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables , complete all as specified . Note : GI pipe shall be measured and paid separately.
Supply & laying steel tubing of GI Pipe 50mm bore, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting , complete all as specified .
All as per item no. 16 but GI Pipe 80mm bore
Dismantling LT stay assembly complete of any description and removing from site(s), complete all as specified .
M & L stay rod 16mm dia with assembly complete with all accessories such as mild steel galvanised flat iron stay clamp 7/4 mild steel galvanised stay wire, one loop type porcelain vitreous insulator (white, brown or green) overall dimensions 65 x 90mm and clearance of hole 16mm, stay grips, mild steel galvanised stay bow, thimbles, 16mm dia mild steel galvanised stay rod and mild steel galvanised stay plate all as shown in electrical plate No 1 of SSR Part-I, complete all as specified . Note : Excavation, Earthwork and Cement Concrete work shall be measured and paid separately under relevant items of this Schedule
Dismantling cross arms, MS channel, angle section, flat iron, MS rod etc complete and unserviceable materials removing from the site , complete all as specified .
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, notching for wire ( for securing wire mess ) in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chromet primer including preparation of surfaces, complete all as specified .
S & F pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nut, 100mm height, 65mm dia for 1100 bolts grade, complete all as specified .
S & F shackle type, porcelain, vitreous, white brown or green insulator of size 75mm high and 90mm dia including galvanised mild steel straps of section 31mm x 3mm, 12mm dia insulator bolts, nuts, washer etc for working pressure 1100 volts, complete all as specified .
S & F small size loop type insulator, vitreous porcelain, white, borwn or green with overall dimensions 65 x 90mm clearance of hole 16mm, complete all as specified .
M & L for aluminium conductor, steel reinforced (ACSR) of any size as approved on LT poles including straining, binding to insulators with aluminium binding wire with connectors, etc providing PVC sleeves for jumpers as in OH conductors , complete all as specified .
Re-Straining tightening of existing ACSR conductor of any size on LT/HT poles including necessary aluminium binding wire, connectors, PVC sleeves for jumpers etccomplete all as specified and directed by Engr-in-Charge.
Dismantling of LT unserviceable pre-stressed steel poles of any size including taking out of embedded portion of poles from concrete after necessary demolition of concrete foundation and disposal of the same, complete all as specified . Note : Excavation and earthwork etc shall be measured and paid separately under relevant item of this schedule).
M & L for steel tubular swaged poles type 410 SP-31 (9mtr long) complete with cast iron base plate, final taper plug, bolts, nuts & screws including two coats of aluminium paint over one coat of red oxide zinc chromet primer including preparation of surfaces all as specified complete in all respect conforming to IS-2713 and , complete all as specified . Note : (i) Excavation and earthwork cement concrete etc will be measured and paid separately under relevant items of this schedule (ii) Painting of poles with one coat of red oxide primer and two coat of aluminium paint (one coat before fixing and one coat of aluminium paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion. (iii) The portion above coping shall be painted in alternative bands of black and yellow colour starting with yellow colour (each band of 20 cm wide) by two coat of super enamelled paint up to 1.5m height.
Supplying, laying, commissioning & testing LT underground cable of 10Sqmm 2 core, 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes, complete all as specified .
All as per item no. 29 but 16 Sqmm 4 core
All as per item no. 29 but 25 Sqmm 3.5 Core
All as per item no. 29 but 35 Sqmm 3. 5 Core
All as per item no. 29 but 50 Sqmm 3. 5 Core
All as per item no. 29 but 70 Sqmm 3. 5 Core
All as per item no. 29 but 95 Sqmm 3. 5 Core
All as per item no. 29 but 120 Sqmm 3. 5 Core
Supply and fixing in repair aluminium sector lugs short barrel of 25 Sqmm , complete all as specified.
All as per item no. 37 but 35 Sqmm
All as per item no. 37 but 50 Sqmm
All as per item no. 37 but 70 Sqmm
All as per item no. 37 but 95 Sqmm
All as per item no. 37 but 120 Sqmm
All as per item no. 37 but 150 Sqmm
Labour for cutting/ trimming of tree branches up to 80 mm thickness along the alignment of LT /HT over head electric line which are going/ touching or falling or ACSR conductor/ poles or near by sub stns etc at any height from GL and making ta leastlearance 1.5m form conductor and removing to a distance up to 100 mtr where directed by Engineer-In-Charge. Note:- (i) Trimming of the branches on one sides of the conductor. (ii) actual length of cutting will be measured. (iii) The distance as motioned above will be maintained during contract current period & same location subject to at least 6 months period between two trimming/leaping. (i) Measurement will be taken including all conductor as one only.
Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the earth plate not less than 1.5 meters deep below normal ground level, connected with and including galvanised iron strip of size 32 x 6mm connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 40mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completioncomplete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with copper plate electrode of size 60×60cm ×3.15mm buried directly in ground vertically to depth of not less than 2.25 mtr below ground level, with top edge of the earth plate at a depth of not less than 1.5 mtr below ground connected to 20×3mm copper strip by means of bolts, nuts and washers etc made out of GI, earth strip protected by GI pipe medium grade 40mm bore up to 7.5 mtr and connecting to Gen Set, Neutral/Body, including necessary excavation, earth work in any type of soil PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover with 6mm dia MS bars 10 cu C/C on both ways as reinforcement complete all as shown in electrical plate No 3 of MES Schedule Part I, complete all as specified and as directed.
Supply and fix Earth continuity conductor or main earthing lead 20x 3mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified.
Earth continuity conductor or main earthing lead fixed to walls or to poles or any other indicated situation for loop earthing with 32 mm x 6mm aluminium strip complete all as specified and as directed by Engr-in-Charge.
Supply & fix in replacement of MCCB, 3 pole, 100 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 16 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T /Schneider/C&S).
Supply & fix in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T /Schneider/C&S).
Supply & fix in replacement of MCCB, 4 pole, 200 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T /Schneider/C&S).
Supply & fix in replacement of MCCB, 4 pole, 250 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T /Schneider/C&S).
Supply & fix in replacement of MCCB, 4 pole, 400 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T /Schneider/C&S).
Preparation of old painted surface of steel tubular swaged poles (9 to 11 meter long) with good neck brackets including junction box, GI pipe and painting with one coat of aluminium paint including cleaning the acrylic cover and painting with black to 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. by Engineer-in-Charge. Make - Shalimar/Nerolac/Berger.
Preparation of old painted surface of RCC poles up to the height of 1.5 mtr height and painted with one coat of synthetic enamel paint in strips alternative with black and white colour paint and marking pole number including painting MS channel 'D' clamps bracket, GI pipes etc with one coat of aluminium paint complete all as directed by Engineer-in-Charge. Make - Shalimar/Nerolac/Berger.
M & L for installing, testing and commissioning of factry made bus bar chamber comprising of 4 Nos aluminium bus bar of 200 Amp rating supported on insulator and enclosed with sheet steel enclosure out door type made out of 3.15 mm thick CRCA sheet, with top edge tappered, dust and vermin proof , having locking arrangement at front and opening arrangement from front & rear both including fixing arrangement on pole/gorunting in floor, with colour coded FRP with compression cable glands for entry & exit of cables, powder coated all specified and directed by Engr-in-Charge.
M&L for chain link fencing galvanised including line wires 4 mm dia, mesh size 150x100mm weight not less than 2.3 Kg/sqm and type of standards rails, straining bolts etc. Including provision of binding wire and fixing complete all as specified and directed.
m/s allied enterprises
M/s RAM LAKHAN GUPTA
Ajanta Motor Store
R.S Enterprises
His And Her Enterprises
Khan Brothers
Avion Industries
Eco Creations
Aawadh associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .