| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-Finance DR SEWALIYE SIVAJI GANESAN NAGAR 3RD STREET DINDIGUL 642 001 | COIMBATORE | TAMIL NADU | 642001 | ₹46.5 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹48.0 LAccepted-Finance | ₹48.0 L | L2 | Accepted-Finance Accepted |
| 3 | L3₹49.4 LAccepted-Finance C 234 ADG P CHENNAI | ₹49.4 L | L3 | Accepted-Finance Accepted |
| Sl No | Description | Qty | Unit | N SARAVANAN L1 | GMS Builders L3 | SREE VARI INFRA L2 |
|---|---|---|---|---|---|---|
| 1.00 | Surface Excavation n. exc. 30cm deep & avg 15 cm deep & getting out in hard dense soil. | 195.5 | sqm | 110 ₹21,505 | 115 ₹22,482.50 | 150 ₹29,325 |
| 2.00 | Rough earth work excavation in ordinary soil up to a depth 1.5 mtr. From the starting point | 293.25 | cum | 400 ₹1.2 L | 420 ₹1.2 L | 45 ₹13,196.25 |
| 3.00 | Excavating in trenches n .exc 1.50 m depth and getting out in hard dense soil | 229.5 | cum | 800 ₹1.8 L | 837 ₹1.9 L | 650 ₹1.5 L |
| 4.00 | Excavating in trenches n .exc 1.50 m to 3.0 m depth and getting out in hard dense soil | 229.5 | cum | 1,200 ₹2.8 L | 1,255 ₹2.9 L | 1,200 ₹2.8 L |
| 5.00 | Plain Cement concrete 1:4:8 type C1 using 40mm graded aggregate in surface channels and drains | 27.46 | cum | 10,000 ₹2.7 L | 10,450 ₹2.9 L | 10,500 ₹2.9 L |
| 6.00 | R.c.c. footing with cement mortar 1:2:4,using 20mm graded stone aggregate as in foundation | 32.4 | cum | 15,000 ₹4.9 L | 15,675 ₹5.1 L | 14,800 ₹4.8 L |
| 7.00 | R.C.C 1:2:4 using 20mm graded aggregate columns | 12.42 | cum | 15,000 ₹1.9 L | 15,675 ₹1.9 L | 14,800 ₹1.8 L |
| 8.00 | R.C.C 1:2:4 using 20mm graded aggregate beams | 12.54 | cum | 15,000 ₹1.9 L | 15,700 ₹2.0 L | 14,800 ₹1.9 L |
| 9.00 | Reinforced Cement concrete in roof slab | 24.05 | cum | 15,000 ₹3.6 L | 15,700 ₹3.8 L | 14,800 ₹3.6 L |
| 10.00 | Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hopping ends and binding with and including MS wire not less than 0.9mm dia. | 8,141 | kgs | 130 ₹10.6 L | 136 ₹11.1 L | 128 ₹10.4 L |
Tender Value
₹49 L
EMD Value
₹49,000
Closing Date
19 Feb 2026, 4:00 pmClosed
The CEO, Cantonment Board Wellington
Cantonment Board Wellington, The Nilgiris-643231
E- TENDER FOR THE YEAR 2025-2026 - PROPOSED ADDITIONAL CLASS ROOM FOR CANTONMENT BOARD SECONDARY SCHOOL AT CHINNA VANDISOLAI, WELLINGTON
2026_DGDE_750641_1
WCB/002/2026
Open Tender
Civil Works - Others
180 days
Cantonment Board Wellington
As per Tender Document
2 documents required · 2 mandatory
₹2,000
The CEO, Cantonment Board Wellington
₹49,000
23 Feb 2026
30 Jan 2026
20 Feb 2026
30 Jan 2026
19 Feb 2026
31 Jan 2026
31 Jan 2026 - 31 Jan 2026
Surface Excavation n. exc. 30cm deep & avg 15 cm deep & getting out in hard dense soil.
Rough earth work excavation in ordinary soil up to a depth 1.5 mtr. From the starting point
Excavating in trenches n .exc 1.50 m depth and getting out in hard dense soil
Excavating in trenches n .exc 1.50 m to 3.0 m depth and getting out in hard dense soil
Plain Cement concrete 1:4:8 type C1 using 40mm graded aggregate in surface channels and drains
R.c.c. footing with cement mortar 1:2:4,using 20mm graded stone aggregate as in foundation
R.C.C 1:2:4 using 20mm graded aggregate columns
R.C.C 1:2:4 using 20mm graded aggregate beams
Reinforced Cement concrete in roof slab
Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hopping ends and binding with and including MS wire not less than 0.9mm dia.
Form work sides of concrete surfaces in foundation footings
Form work sides of concrete surfaces in Columns
Form work sides of concrete surfaces in Beams
Form work to soffits of suspended slab such as roof slab not exceeding 250mm thick
Returning and filling including spreading levelling watering and well ramming in layer n exc 25cm
Removing excavated soil to a distance of 50 mtrs
Rendering in cement mortar 1:6, 15mm thick on fair faces of walls
Ceiling plastering with cm 1:3, 15mm thick of roof slab
Plain cement concrete 1:2:4 type C1 using 20mm graded stone aggregate as in bed block
Screed bed or bedding layer of 1:4 motor 15mm thick for laying floor finishes
Steel doors complete including protection type hings etc., with glazing bars
White washing on wall surface three coats including preparation of surface
White washing on Ceiling surface three coats including preparation of surface
Preparing newly plastered wall surface and applying two coats of cement based paint over a coat of primer
Preparing steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer
M& L for complete with GI earth plate electrode 600 x 600x6 mm thick buried directly in ground earth plate not less than 2.25 m deep below ground level with top edge of the earth plate not less than 1.5 meter below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nuts, check nuts, washers and GI earth wire protected by 15 mm dia GI pipe for watering funnel, Earth work PCC chamber with 40 mm thick RCC 1:2:4 type 'B' for cover slab with 6 mm dia MS bar and 100 mm both ways with MS Hook 8 mm dia all as shown in electrical plate No. 5 all as specified and as directed.
M & L for sub main wiring with 2 runs of single core stranded copper copper conductor 6 sqmm PVC inculated and unsheathed drawn through and including suitable size non metalic regid PVC conduit with all acessories fixed to walls, ceiling including 1 run of 4.00sqmm copper ( Insulated) cable as earth contiunity xonductor including taking down existing unserviceable sub main wiring all as specified and as directed. Note: Two runs of conductor and one run of earth wire and one run of PVC conduit shall be measured as one unit.
Supply and fixing double door MCB distribution board in sheet metal enclosureSPN 8 way with 200 Amps, 240 Volt rated bus bar neutral and earth connected bars for use of MCB’s fixed properly at directed place by using suitable required fixing arrangement
Supply and fixing double door MCB distribution board in sheet metal enclosure TPN 4 way with 200 Amps, 415 Volt rated bus bar neutral and earth connected bars for use of MCB’s fixed properly at directed place by using suitable required fixing arrangement
Supply and fixing RCB SPN 16Amps, 30mA breaking capacity, 240Volt AC all as specified and as directed.
Supply and fixing RCCB TPN 40Amps, 30mA breaking capacity, 415Volt AC all as specified and as directed.
Supply and fixing MCB SP 6/ 32Amps, 10KA rupturing capacity, 240Volt AC all as specified and as directed.
Supply & Connecting Tamper proof Electronic Energy Meters three phase 240 V, AC , 50 HZ, ISI marked Class I, LCD type 30 to 60 Amps capcity, including making seal of MES afater removing the old unserviceable meters all as specified and as directed. (Make : L & T or Equivalent)
M & L for sub main wiring with 2 runs of single core stranded copper copper conductor 6 sqmm PVC inculated and unsheathed drawn through and including suitable size non metalic regid PVC conduit with all acessories fixed to walls, ceiling including 1 run of 4.00sqmm copper ( Insulated) cable as earth contiunity xonductor including taking down existing unserviceable sub main wiring all as specified and as directed. Note: Two runs of conductor and one run of earth wire and one run of PVC conduit shall be measured as one unit.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting 1x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fixing LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
BOQ_840706.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid