Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹98.5 LAdmitted-Finance | -13.35% | ₹98.5 L | L1 | Admitted-Finance |
| 2 | L2₹1.1 CrAdmitted-Finance 120 2 A BLOCK 8 KAMLA NAGAR KANPUR NAGAR 208005 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208005 | -5.89% | ₹1.1 Cr | L2 | Admitted-Finance |
Tender Value
₹1.1 Cr
EMD Value
₹2.3 L
Closing Date
20 Feb 2026, 1:00 pmClosed
SE PHED CIRCLE SRIGANGANAGAR
SE PHED CIRCLE SRIGANGANAGAR
Balance work for Rejuvenation, Renovation and providing, laying and jointing of Pipe line for providing FHTC in each house hold at RWSS 15 PS with defect liability period 1 year in sub division Raisinghnagar division Anoopgarh under JJM
2026_PHCJA_533339_1
SE/PHED/SGNR/2025-26/05
Open Tender
Civil Works
180 days
Anoopgarh
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
EXECUTIVE ENGINEER PHED DIV. ANOOPGARH
₹2.3 L
Yes
18 Mar 2026
29 Jan 2026
20 Feb 2026
29 Jan 2026
20 Feb 2026
29 Jan 2026
Part A (Rejuvation of storage tank)
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Earth work excavation for Sedimentation cum storage tank including disposal of excavated earth to be disposed outside of head works boundary. If earth is to be disposed at more than 200 M distance than distance separate payment for each lead beyond 200M distance will be payable as per PWD BSR effective from 01.01.2005. Disposed earth to be leveled and neatly dressed including stacking of useful material if any available during excavation for all kind of soil. Earth work to be carried out by means of mechanical system i.e. “Tractor craw” are any other mechanical system. No extra payment shall be made for lift of any limit. This work also involves dressing of sides and bottom of lining purposed which is be done manually, slope of sides is to be maintained as per specification and drawing.
Silt clearance from Sedimentation cum storage tank with lift upto 4.5 Mtr. and lead upto 50 Mtr. Silt to be disposed outside of Headworks Boundaries. Disposed silt to be levelled and neatly dressed including stacking of useful material if any available during excavation for all kind of soil. Silt to be carried out by means of mechanical system i.e. Tractor craw/Trolly or any other mechanical system. No extra payment shall be done for lift of any limit. This work also involves dressing of bottom purposed which is to be done mannually to be maintained as per direction of Engineer In Charge.
Add :- Extra for every additional lead up to 1 KM.
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
“Preparing surface leveled and dressed to proper slope and lying over it tibba sand properly rammed and watered in to layers of 5cm each. Providing & lying ISI marked 250 micron LDPE film as per ISS : 2508-1984 including interlocking by using thermal welding or ultrasonic welding are sealing tapes on the finished surface compacted tibba sand. LDPE film to be anchored in parapet/Toe wall or any other structure etc as per direction. Over the LDPE film 15mm thick cement bajri mortar 1:3 shall be provided & laid. Over this mortar single layer Ist class flat brick lining in cement bajri mortar 1:3 shall be provided with joints not more than 8mm wide. It includes providing weedicides and anti-termite treatment as per specification “ and curing. Measurement of lining area will be payable. (Film used in anchoring is not payable)
Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar.
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 meters (stacks of cleaned bricks ahall be measured): From brick work in Cement mortar.
Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in foundation and plinth with Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in foundation and plinth with Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish: 12 mm thick.
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 20mm thick .
Recovery of old Bricks
b. INTER CONNECTION SUMP WELL TO STORAGE TANK
Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specification of concerned IS Code 210-1978 (IS 1538:1993) and as per direction of Engineer:-150MM
Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated CI D/F Sluice valves of approved make (IS: 14846- 2000- amended upto date- For Sluice Valve) PN 1.0 class and CI Tail Piece- 2 Nos. (IS: 5531- 1988- amended up to date- For CI Plane Ended Specials) of same size of following dia complete including all material like Instren Rubber Sheet of thickness- 6.00 mm (ISI Mark)- For Rubber Sheet), MS Nut Bolts (IS: 1363 Part I-1984- amended up to date), CI Detachable Joint (IS: 8794- 1988 amended up to date), labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. Nominal Dia. 150 mm
Providing and Fixing of PVC float arm with PVC flexible hose pipe 7.5 Mtr long and 150 mm dia. This also included tail pieces 150 mm dia on pipe's side and tail piece of required shape and 150 mm dia as hose pipe end for fixing float arm. All material should be confirming to relevant IS code. PVC float should be of capacity 100 Ltr. minimum. This job also includes dismantling of old system from storage tank. supply and fixing complete work in all respect.
PART B (P,L,J & Testing of Raising Main Pipe line(HDPE PE-80, PN-06))
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80 PN-6 90 mm dia
……………………….110 mm dia
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. In all type of soil For HDPE pipe line dia up to 110 mm
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended upto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS, Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS: 6418, Fastners - CS, All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. Class PN 1.0 40 mm
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date), Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Grey cast iron of grade IS:210/FG200 ,Float- LP ball & HP ball : AISI 304 stainless Steel, Float Guide- HTB1,Seat ring & Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside, Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, with CI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.0 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. Class PN 1.0 40 mm
Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of severciable & un serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block, all lead and lift as per general specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) b) 80 mm thick.
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.Bituminous courses
Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Manually Operated CI Sluice valve of Class PN-1.0 Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 80 mm HW
--do-- 100 mm HW
Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer.
SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. BFM 80 mm
BFM 100 mm
Construction of VTC Chamber
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Walls ( any thickness) including attached pilaster buttresses , plinth and string course
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Suspended floor, roofs, landings, staircases, balconies girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chajjas, lintels, beams etc.
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)Thermo-mechanically Treated bars (Conforming of relevent IS code)
Supply and fixing R.C.C. Main holes cover with frame of approved make (Light duty).(450 mm Dia)
PART C ( Providing Fitting & Fixing of Pumpset)
Supply and installation of electric driven 3 phase mono block pump sets confirming to IS:9079 of make Kirlosker, Texmo, Crompton, Taro, Siemens, ABB or equivalent make for raw water etc with perfect alignment and testing of complete system following capacity and size. This work also includes fitting with delivery and suction pipe line including fitting material like Nut Bolt, Dhaga, Rubber Sheet etc (Excluding GI Pipe/MS Pipe, CI specials cost) Complete job as per direction of Engineer-incharge :- Mono block pump with Syn Speed 300-600 LPM/15-12m Head/3 HP
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 operating at sync. speed 2900 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee. Centrifugal Monoblock Pump set (Single Stage) 12.5 HP
P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :- (External Work) Medium Duty Pipes_100 mm dia nominal bore.
P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :- (External Work) Medium Duty Pipes_80 mm dia nominal bore.
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6-.80mm
Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.0 100 mm dia
………………………..80mm dia
P & F foot valve of superior quality and approved make with fittings : 80/100/125mm
P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :- ( External Work ) Medium Duty Pipes 20mm dia nominal bore
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 20mm nominal bore.
Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :20mm dia nominal bore
P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including placing on terrace( at all floors),making connection etc. complete of approved design. Details of cost for 500 litre
P & F bolts including nuts and bolts complete.
Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer.
Part D ( Providing, Installation and Commissioning of Electric Composit Panel Board )
SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator)
Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Electrolytic grade Aluminium bus bar
SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required.up to 100 Amp , 10 kA, fixed O/L & S/C setting
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required.up to 125 Amp ,25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
Providing and fixing of three pole power Contactor confirming to IS 13947-4-1 IEC 60947-4-1. Standard coil voltage 110, 240, 415, 440V 50 Hz as per ISI marked/approved make L&T, GIC, ABB. Simenes Contactor AC3 rating (415) 12 Amp Motor output 3 phase 7.5 HP
Providing and fixing of three pole power Contactor confirming to IS 13947-4-1 IEC 60947-4-1. Standard coil voltage 110, 240, 415, 440V 50 Hz as per ISI marked/approved make L&T, GIC, ABB. Simenes Contactor AC3 rating (415) 25 Amp Motor output 3 phase 15 HP
P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. Up to 14 Amp
P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.21 to 30 Amp
SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required. Red/yellow/Green colour
P & F push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Luminous type Red , Yellow, Green, Amber
Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 10 SWG copper. Wire
SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type
SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A
SF of Current Transformer , with all necessary support in existing panel including connection etc. as required. up to 150 / 5 Ratio , 5 VA , class 1 accuracy
P&F of RCBO with overload, short-circuit and earth leakage protection ISI marked (IS12640)/ conforming to IEC 61009/1 complete in all respect including making connections, testing etc. as required. Two pole 100/300mA sensitivity 16 A rating
P&F 240/415 V Residual current circuit breaker conforming to IS:12640:1988/ IEC 61008 on existing board/sheet including making connections, testing etc. as required Two pole 30 mA sensitivity 25 A rating
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 1 x 1.5 sq.mm
1 x 2.5 sq.mm
1 x 4.0 sq.mm
1 x 6.0 sq.mm
Supply and laying PVC insulator submersible cable 3 core copper conductor of superior quality making connection etc in the following size as per related code, ISI Marked. 3 core 6.0 Sq.mm
Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 2 x 2.5 sq.mm
2 x 4.0 sq.mm
2 x 6.0 sq.mm
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. Single pole MCB 0.5 A to 5 A rating
6 A to 32 A rating
Double pole MCB 6 A to 32 A rating
Triple pole MCB 6 A to 32 A rating
SITC of microprocessor based three phase sensing power factor correction relay having following sensing capacity secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, metering facility as required. 6 to 8 stage sensitivity up to 50 milli Amp
P & F of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current , conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 7 to 10 KVAR
SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR . including making connections with suitable capacity conductors/cables testing etc. as required. Heavy duty Three phase 440 V , 50 Hz capacitor (Bank)
Providing and fixing of Timer as per ISI marked/approved make L&T, GIC, ABB. Simenes Electronic Timer 240/360 volt 415 Hz for 3 to 10sec./9 to 30sec./30 to 120sec
Single phase Prevantor with automatic approved make L&T, Simenes, Vishnu.
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 35.0 Sq.mm, 3.5 core
Part E ( Reju. Of RCC CWR)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix.
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix.
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Arches, arch ribs, domes, vaults, shells, folded plate, chimneys, shafts , roofs having slope more than 15º ,vertical and horizontal fins individually or forming box louvers, facias and eaves boards M20 grade Nominal Mix / Design Mix Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix.
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for: Walls (any thickness) including attached pilasters, buttresses, plinth and string course.
Add for Centering and Shuttering for circular work in plan up to dia 10 m
Arches, domes, vaults etc. up to 6 Mtr. span.
Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.
Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25x25mmx16 gauge.
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing Square bars or other flat welded to window, ventilators etc.
Painting with enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
Part F (Rejuvenation of SSF's)
Providing and Placing of new filter media as (i) Sand shall be hard and resistant quartz or quartzite and free of clay, fine particles, soft grains and dirt of any description. (ii) Effective size shall be 0.20 to 0.30 mm. (iii) Uniformity Coefficient not be more than 5.0 nor less than 3.0. (iv) Ignition loss should not exceed 0.70% by weight. (v) Soluble fraction in HCL acid shall not exceed 7.0% by weight, (vi) Silica content should not be less than 95% (vii) Specific Gravity shall be in the range between 2.55 to 2.65 (viii) Wearing loss shall not exceed 3.0%. and as per specifications given in IS: 8419 (Part-I). (ix) The sand should not contain more than 2% of calcium and manganese calculated as carbonate. Filter media (fine sand and coarse sand) should be processed through. Disindicator and dust seperator in automatic plant including screening of sand to desired. Specification and washing and cleaning of sand with water by aqua wash technology at quarry site. The sand shall not contain more than 5% acid soluble matter as determined by solubility test in Appendix B of IS: 8419 (Part-I) (Fine sand 0.2 to 0.3mm and coarse sand 1.0 to 1.7mm)
Supply of 90 mm dia UPVC pipe
Fixing of pipes for under drainge system including plugging pipes with CM 1:4 on one end and fixing other end in collecting channel with CM 1:4 with all Material etc.(Excl.cost of pipes) This job, also, includes Making 4mm dia holes in pipes @15 cm c/c in zig-zag patternhis and testing of under drainage system as per instruction of Engineer-in-charge.
Making 4mm dia hole in pipes of under drainage system of filters duly drilled. Carriage of pipe from stacks to filter site, making two per rows on pipe and points of making holes in Zig-Zag pattern in two hold raw. Making 4mm dia holes with drill machine @ 15cm
Labour charges for screening of old sand (received from filter beds) through the standard sieves, washing the sand with HCL acid of required concentration as directed by the Engineer- In- Charge, so as to remove all the mud and other deposits from sand grains and then clean with water till the sand is as neat and clean that it impart no colour to clean while washing. It also includes placing this washed filter media (sand) in filter beds in layer as instructed by the Engineer- In- Charge. (RGF, SSF)
Labour charges for screening of old gravel (received from filter beds) through the standard diffrent sizes sieves for required sizes of gravel, washing the gravel with HCL acid of required concentration as directed by the Engineer- In- Charge, so as to remove all the mud and other deposits from gravel grains and then clean with water till the gravel is as neat and clean that it impart no colour to clean while washing. It also includes placing this washed gravel in filter beds in layer as instructed by the Engineer- In- Charge. (RGF, SSF)
Removing of sluice valve in existing distribution pipe line and repair of pipe complete as required in existing system of pipe line:- 125 mm to 150mm
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 . 150 mm
Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer.
Demolishing brick work including stacking of serviceable material and disposal of U/S material within 50m lead (B/W in cement mortar)
Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in foundation and plinth with Cement mortar 1 : 4 (1 cement : 4 coarse sand)
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finished 12mm thick. One coat
Providing and laying in position specified grade of reinforced cement concrete including curing compaction finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. All work up to plinth level : 1:1:2 (1-Cement:1-Coarse sand:2-graded stone aggregate 20 mm nominal size) M- 25.
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Three or more coats).
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.HDPE PE-80 PN-6 110 mm dia
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M. HDPE PE-80 PN-6 160 mm dia
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. In all type of soil For HDPE pipe line dia up to 110 mm
……………..For dia of pipe above 150 mm and up to 350 mm nominal.
Part G (Provision for Construction of Pump House)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead.In Cement mortar.
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 meters (stacks of cleaned bricks shall be measured): From brick work in cement mortar.
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in foundation and plinth with Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .75mm thick.
Brick masonary in super structure with brick of class designation 75 in cement mortar 1:6 upto 4.5M height above plinth level.
Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members and removal of formwork for superstructure up to 4.5 mtr above plinth, for: Walls (any thickness) including attached pilasters, buttresses, plinth and string course.Add extra for centering and shuttering work in superstructure above floor five level for each four floor or part thereof .
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix Add extra for providing richer mixes espectively at all floor levels Providing M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix.
Providing and laying tiles of class designation 100 over mumty roots, grouted with cement mortar 1:3 mix with 2% crude oil by weight of cement over 12mm thick layer of cement mortar 1:3 and finished neat.
Filling local sand in trenches, plinth,sides of foundtion, under floor etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by remming and watering including all leads and lifts.
P&F T-iron, angle iron frames for doors made of mild steel tee or angle section, joints mitred & welded with 15x3 mm lugs 10cm long embedded in CC blocks 15x15x10 cmsize of 1:3:6 or wooden plugs, screws or with fixing clips and screws or with bolts and nuts as required including fixing of necessary hinges, screws and applying a priming coat of approved steel primer.
Providing and fixing M.S. sheet 1mm thick double leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and1.4 mm aperture on both sides
P/F Square bars or other flat welded to window, ventilators.
Cement plaster on new surface on walls with cement bajri mortar 1:4 including finishing of corners the complete 12mm thick in one coat.
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)For area of each slab from 2001 to 5000 Sq.Cm
Providing and appling wall putty (JK/Birla or equivalent)or POP Filling complete to achieve fine finish one or more coat
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: one or more coats on old work including prepartion of base with primer, putty, lippy etc complete in all respect.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on Old work
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Three or more coats).
Recovery of old Bricks
Wiring of light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq.mm FR PVC insulated unsheathed flexible earth copper conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit and its accessories , 18 SWG M.S. Box with earthing terminal, 6 A switch 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections testing etc; as required - G-1-Short point ( up to 3 mtrr.)
Medium point ( up to 6 mtrr.)
Long point ( up to103 mtrr.)
Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq.mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit and its accessories , 18 SWG M.S. Box with earthing terminal, 6 A socket 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections testing etc; as required - G-1 On boartd
Supplying and drawing RC PVC insulated & unsheathed flexible copper conductor ISI marked ( IS:694) of 1.1 KV grade and approved make in existing surface of recessed conduit/casing capping including making connections etc. as required. Group-1-2 x 1.5 sq. mm
2 x 2.5 sq. mm
Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175x100x60 mm on surface or in recessed with suitable size phenolic larninated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet making connection, testing etc as required
P & F 240/415 V MCB of breaking capacity not less than 10 KV ( B/C/D tripping characteristic) ISI marked IS:8828 (1998)/conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. Group-1 6 A to 32 A rating
P & F 240/415 V isolator conforming to IS:13947-III/ IEC 60947-3 on existing board/ sheet including making connections with lugs, testing etc. as required Group-1 30 A/ 40 A rating
P & F Recessed/Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link, neutral link, earth link and din bar, conforming to IS 13032 & IS8623 including making internal DB terminatyions with coppper lugs, testing etc; as required 6 Way
P & F ISI marked flush type 120/280 watt rotary step fan regulator including making connection testing etc. as required.
P & F TP&N 415 V AC-23A front handle operated switch disconnector fuse unit cubical type, without metallic enclosure, confirming to IS-13497 P-III in existing panel (W/O HCBC fuses) including making connections with lugs, testing etc. as required. Group-1 32 A rating
Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and brick masonary finished chamber covered with ferro cement cover CI frame of size 300 mm x 300 mm complete with alternate layers of sals charcol / coke, testing of earth resistance as rquired.
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 10 SWG copper Wire.
P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side .
P & F Star rated double ball bearing capacitor start, aluminium body & blade ceiling fan with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.1200 mm Sweep 5 Star rated
P & F strip type fluorscent tube fitting fabricated from (CRCA sheet and finished with powder coating / stove enamelled paint) / (extruded non corrosive UV resist EP channel) complete with accessories (Low Loss Copper Choke, starter, starter seat) / Electronic Choke with terminal block duly prewired with copper conductor including making connection, testing etc. as required( without tube).1 X 36 Watts with OCCB
P & F Flucrscent tube rod in existing fixtures as required. Group-1 36/40 Watts
Wiring for sub mains ISI marked ( IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWS G.I. Support wire duty clipped etc. as required. Group-1, 4.0 sq. mm
P & F energy efficient direct fit (Retrofit) LED tube system (with integral driver), on existing fixture. Power Consumption of 18W / 36W 1500-3000 lumens, system lumen efficiency 80 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K & 6000°K.4' LED 4' LED Tube shape fixture 18W
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with Copper conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.2.5 sqmm, 2 core.
P & F IP-65 / IP-66 protected LED street light luminaire on existing bracket. Fixture made from powder coated single piece pressure die cast aluminium housing with Heat dissipation fins on housing with High Power LEDs of CREE / NICHIA / OSRAM / PHILIPS make. DIffuser / Glass cover for ensuring IP65 protection for Lamp & control gear compartment, System Lumen output of 1500 - 8500 High Power LED. Integrated Driver shall be high efficiency having efficiency > 85% and in compliance to IEC standards System life of 25,000 Burning Hours with 70% of initial Lumens maintained. Fixture shall be in CE Compliance. IP - 65 Protected LED Street Light Luminaire. Group A-1 LED Street Light fixture 20-25 Watt
Supply and erection of hot dipped galvanised steel swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate in position including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals , cable entry, GI cable sleeve complete as required. The pole shall be galvanised using ISI mark seamless tube for structural purpose of following height & designation. ( See Table E - 09 for specs. )7.5 Mtr. ( 410 SP - 5 )
P&F 240/415 V isolator conforming to IS:13947-III/ IEC 60947-3 on existing board / sheet including making connections, testing etc. as required. Double Pole - 30/40 A rating.
Part H (P,L,J & Testing of Distribution Main Pipe line(HDPE PE-80, PN-06)
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80 PN-6 75 mm dia
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80 PN-6 90 mm dia
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated CI Sluice valve of Class PN-1.0 80 mm HW
…………..do 100 mm HW
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. In all type of soil For HDPE pipe line dia up to 110 mm
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.Bituminous courses
Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.
Part I (Providing service connection in each house hold)
Providing service connection as per technical specification and standard drawing as per relevant IS code (amended up to date) from all kind of water mains up to consumer meter/premises (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil including demolishing of cement concrete,WBM, Black top etc. of all thickness; cutting of CC road/jhiri by using a concrete cutter machine; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 50 meter ; providing & fixing of all fitting duly approved in accordance with ISO/DTR 9080 as per specification for potable water including approved make of MS/PVC clamp with saddle piece, gunmetal ferrule 4.0 mm (ISI make) , valve (IS: 778) and specials with MDPE pipe PE 80 PN 12.5 as per ISO 4427 below ground level and GI 15 mm class B 1.19.1 Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm 1.19.2 House hold tap connections (ISI mark) above ground level ( max. length 3.0 mtr), P&F a Bib Cock (IS : 8931 Mark), Superior quality Brass 400 gm,15 mm nominal bore including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . In addition to the ferrule, an orifice of 4.0 mm dia should also be provided in the service line at the entry point of the consumer's property in such a way that it should be accessible for inspection to VWSC, PHED and any other authority which would like to inspect as and when required. The service line should be laid at least 45 cm below ground level, except in case of concrete/bituminous roads where minimum depth shall be 20 cm. For detailed specifications of MDPE pipes please refer section "Technical specifications" of bid document. General specifications of MDPE pipes shall be as under: • The raw material shall be virgin PE 80 Blue compound and comply with the requirements of ISO/Directive of testing material : 9080 with minimum equired strength of 8 Kg/sq.cm. • The raw material shall be Food grade quality Pressure rating shall be 12.5 Bar. • The pipes shall bear ISO marking. Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm GI Class B Pipe
Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in; work includes visiting the village for collecting basic data consumers like i.e. Aadhar no./ration card/voter ID/BPL card/ PAN card/driving licence/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.43 MB
BOQ_950453.xls
BOQ • 0.61 MB
TD05.pdf
Tender Documents • 11.39 MB
Download all tender documents and submit your bid