Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10.6 L
EMD Value
₹21,279
Closing Date
3 Jun 2023, 3:00 pmClosed
Sm ( E ) Z4
1st floor, TE Bldg Goregaon, SV road, Goregaon West, Mumbai-400104
As per NIT
2023_MTNL_754825_1
SM(E)Z4/NIT/23-24/05
Open Tender
Electrical Works
Item Rate
30 days
Charkop RDLU
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (CASH-BW), MTNL
₹21,279
6 Jun 2023
25 May 2023
5 Jun 2023
25 May 2023
3 Jun 2023
25 May 2023
Amount
Servicing of Main Fire Hydrant Pump of capacity 50 HP pump i.e cleaning, oiling, greasing changing of Gasket, Brushing, wiping and testing etc complete as required as per site condition.
Servicing of Diesel engine driven Pump of capacity 60 HP pump i.e cleaning, oiling, greasing cleaning Filter and changing of Gasket Brushing, changing of coolant of engine oil and filters, wiping, and testing etc complete as required as per site condition.
Servicing of Main Sprinkler Pump of capacity 50 HP pump i.e cleaning, oiling, greasing Brushing, wiping, and testing etc complete as required as per site condition.
Servicing of Jockey Pump of capacity 7.5HP pump i.e cleaning, oiling, greasing, Brushing, wiping, and testing etc complete as required as per site condition.
Replacement of booster pump (SITC) of 900 LPM at 40 m Head, 10 HP (7.5KW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification ( This item includes removing the faulty motor)
Supplying, installing pressure gauge of 100mm dia,0-21 kg/cm2, fitted with 12/15 mm dia pad cock valve etc. complete as required including removing existing faulty pressure switches and handing over to building incharge.
Servicing i.e cleaning, oiling, greasing Brushing, wiping, and testing etc. and repairing of all cut off Valves of different sizes (butterfly valve, gate valves and ball valves.)
Repairing, cleaning, oiling and servicing of hydrant valves to the wet riser flanged tee at each floor
Replacement of hydrant valve parts i.e coupling, lugs and washer
Repairing ,cleaning, oiling and servicing of hydrant valves to courtyard stand posts including all nuts bolts gaskets etc. complete.
SITC of First-Aid-Fire Hose reel, wall mounted swinging type, complete with drum, bracket,25mm diameter MS Piping up to riser , 25 mm brass ball valve,20mm diameter 30 meter long high pressure Thermoplastic reel as per IS:12585 tubing (I.S.I.marked) with PVC jet and spray type shutoff nozzle with 5mm diameter orifice complete as required
Providing and fixing in position 2 lengths of 15 M long controlled percolation hose RRL fire hose 63 dia (as per IS 636)with adapter and nozzle and stroking them in metal cabinets with lockable glass shutters and fixing the metal cabinet at ground level in a location where it can be easily spotted including painting etc
Supplying and erecting M.S./CRCA cabinet (size 400 x 800 x 400mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour
Servicing ,cleaning and oiling of 4 nos. 65 dia breaching inlet and Siamese connection near the building compound wall for connecting to fire fighting tank.
Replacement of Back up Batteries of 12 vlt.150 AH. Accessories.
Servicing ,cleaning and oiling of gong valve for sprinkler system
Changing of Diesel oil for Diesel pump (i/c cleaning the diesel tank & painting)
Above Ground: SITC of 100mm dia ERW G.I.Pipe 'C' class with necessary fittings like Elbow, Tee, Reducer, Flange, Nipple, bend etc above ground of following sizes conforming to IS:1239 with one coat of red oxide primer and two coats of post office fire red enamel paint etc complete as required.
Under ground: SITC of 150mm 'C' class ERW G.I pipes with necessary fittings like Elbow, Tee, Reducer, Flange, Nipple, bend etc as per IS:1239-1973 with one coat of hessian and two coats of anti corrosive primer ( Black Japan) & 4mm thick Wrapping as per IS 10221to be laid at a depth of 1 mtr. Below ground from pump house to ring main, ring main of wet risers etc. complete as required.
Excavation & filling of trencher for underground piping in RCC/PCC/ Hard / Road/hard morrow etc, complete as require.
Excavation & filling of trencher for underground piping removing extra earth morrow complete as require (soft soil/ earth)
Supply and fixing M.S support to pipe angle frame with one coat of red oxide primer and two coat of post office red enamel painting etc complete as require.
Replacement of 25 mm dia air release valve
Supplying and installing cast iron wafer style butterfly valve confirming to IS 13095 ISI mark, having cast iron body lining black Nitrile/ Neoprene, disk of G.M/ IS 318, S.S.shaft IS 1570, with nut bolts, gaskets etc complete as required. of 150 mm dia
Supplying and installing cast iron wafer style butterfly valve confirming to IS 13095 ISI mark, having cast iron body lining black Nitrile/ Neoprene, disk of G.M/ IS 318, S.S.shaft IS 1570, with nut bolts, gaskets etc complete as required. of 100 mm dia s) using
Supplying, Installing C.I Wafer type dual plate check valve/ NRV having S.S Hing & Stop Pin, design as per API 594 and comply with API 598 testing standard. With nut bolts, gaskets etc, complete as required.100 mm dia
Supplying, Installing C.I Wafer type dual plate check valve/ NRV having S.S Hing & Stop Pin, design as per API 594 and comply with API 598 testing standard. With nut bolts, gaskets etc, complete as required 150 mm dia
Charges for Repairing of Fire Alarm System. With Main Control Panel, with repairing of 12 Zone Cards, power supply module, faulty relay and IC etc. ( This item includes servicing of all detectors, RI, Hooters, PA system, exit sign boards, tighting of cables etc)
Charges for Repairing of Local Control Panel, with repairing of 4 Zone Cards, power supply module, faulty relay and IC etc.
Replacement of 12 Volt 26AH Backup Batteries
Replacement of 12 Volt 7AH Backup Batteries
Supplying, Installing, Testing & Commissioning of Multi criteria Photoelectric Type Smoke Detectors i/c base complete as per attached specifications.
Supplying, installing and testing of 150mm dia C.I. Foot valve with strainer with nuts, bolts, gaskets, washers etc for positive suction etc. complete as required
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .