CWE AIR FORCE SECUNDERABAD
CWE AIR FORCE SECUNDERABAD, BOWENPALLY-POST, SECUNDERABAD- 500 011
REPAIR AND MAINTENANCE TO HT ELECTRIC SUPPLY AND CONNECTED WORKS AT AFS HAKIMPET
2020_MES_380523_1
84635/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) HAKIMPET
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) HAKIMPET
₹49,000
Yes
26 Dec 2020
25 Sept 2020
5 Nov 2020
25 Sept 2020
3 Nov 2020
21 Oct 2020
25 Sept 2020 - 3 Oct 2020
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard/dense soil for laying of cables/ erection of poles/ stay assembly etc complete all as specified and directed.
Cutting of road crossing, PCC hard standing for laying of cable/protection pipe including making good the existing surface with existing finish to match the original ground complete all as directed by Engineer-in-Charge.
Supply and spread clean dry river sand in trenches for cushioning of cable complete all as specified and directed. (Note: Punned thickness shall be measured)
Supplying and laying un-reinforced precast concrete cable cover, Class HV, Type I, flat, size 300 mm x 180mm x 40mm for protection of under ground cables complete all as specified and directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified.
Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
M & L in repair 80 mm dia bore tubes, 'light grade' galvanised, with all fittings and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed.
Supply only in replacement of Insulation mat of 1 mtr width x 2 mtr length x 3 mm thickness (Voltage grade 11KV) ISI marked IS 15652, CPRI approved of blue colour omplete all as specified and as directed.
S&F in repairs XLPE insulated screened,PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 95 Sqmm, 3 core HT under ground cable complete all as specified and as directed.
Taking out old steel tubular pole 11 mtr long carefully from foundation for re-use, shifting and re-fixing/re-erecting at other location within complex complete including following :- (a) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in soft /loose soil including, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 Mtr. (b) M&L PCC 1:4:8, type D2 ( using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1500 mm for encasing the pole upto GL complete all as specified and directed. (c) M&L PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450x450 mm size. (d) M&L Painting to pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide black bands 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block.
S&F in repirs steel tubular electric pole, swaged type, welded (11 metre long SP - 55) complete with CI base plate, bolts, nuts & screws all as specified including the following:- (a) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in soft loose soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 metres. (b) M&L PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1500 mm (planting depth) for concrete encasing the pole upto GL. (c) M&L PCC 1:3:6, type C2 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia. (d) M&L painting of pole externally with one coats of black bituminous paint (upto planting depth) and above plinth block/ concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surfaces including painting of 30 cm wide black bands 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block.
Checking/ identifying the faulty pin point of HT cable using cable fault locator machine and rectify the defects with necessary excavation, removing of defective portion, adding essential size of cable in required length, meggering & re-storation of electric supply of HT external electric feeder complete all as directed for the following length of cable :-
0 to 500 mtr
0 to 1000 mtr Note : (i) for item No 12.01 & 12.02 Cable fault locator machine with all T&P required for identifying the faulty point will be arrange by contractor which cost is included in unit rate. (ii) Straight through joint will be measured & paid seperately in the relevent item.
Disconnecting of OH line of ACSR conductor/GI earthing wire, opening of binding wires, jumper connections any size and restringing, tightening of conductor with suitable line vice, replacing all worn out jumper connection with suitable conductor, re-tightening and straightening all cross arms, insulators, clamps etc including replacement of all wornout nut bolts and washers complete all as specified and directed .
M&L stringing and fixing in position of new ACSR conductor in OH line on pole to existing insulators, tightening with new aluminium binding wire of suitable gauge, connecting with jumpers for Weasel/Squirrel including taking down old un-serviceable ACSR complete all as specified and directed by Engr-in-Charge.
Supply and install HT 11 KV out door gang operated air break switch suitable for horizontal or vertical mounting fixed type, triple pole, mechanically operated, mounted on 12 or insulators and steel frame, with operating mechanism worked from ground level for current rating upto 200 Amps including taking down old un-serviceable one complete all as specified and directed.
Taking down and servicing, overalling greasing replacing with nuts, bolts & washers of suitable size and refixing as per the orignal, position HT 11 KV out door gang operated air break switch suitable for horizontal or vertical mounting fixed type, triple pole, mechanically operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for current rating upto 200 Amps including one complete all as specified and directed.
Material and labour stay assembly complete of 300 x 300x 6mm thick galvanised stay plate, stay rod of size 20mm including 7 strands of 3.15 mm stay wire with loop insulator complete all as shown in electronic plate No 1 of SSR Part I including dismantling old stay wire assembly complete all as directed by Engineer-in-Charge.
Supply and Fixing Cross Arms, Bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as inclusive of one primer coat. One under coat and one finishing coat of paint incuding dismantling and taking out existing unserviceable compete all as specified and directed.all as specified and directed .
Supply and Fix Lightening Arresters expulsion type complete with all fittings, 65KA, 11 KV discharge capacity, distribution class incuding taking out existing unserviceable one compete all as specified and directed.
Supply and Fix HT Disc type insulator, porcelain, vitreous 145mm high and 255 mm dia ball and socket type, brown single disc assembly for tension with testing clamps for conductors, working pressure 11000 volts grade after taking out old unserviceable insulator complete all as specified and directed.
Supply and Fix pin type HT insulator porcelain vitreous white/brown including one galvanized mild steel spindle, two GI washers and one nut of size 150 mm height and 65 mm dia suitable for 11000 volts grade after taking out old unserviceable insulator complete all as specified and directed.
M&L cable jointing Kit for 11KV grade cable for end box indoor heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
M&L cable jointing Kit for 11KV grade cable for end box indoor heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
M&L cable jointing Kit for 11KV grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 35 Sqmm to 95 Sqmm complete all as specified and directed.
M&L cable jointing Kit for 11KV grade cable for outdoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
M&L cable jointing Kit for 11KV(Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
M&L cable jointing Kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and directed.
Surface dressing not exceeding 15cm deep in hard/ dense soil complete all as specified and directed.
Taking down unsv breather and supply & fix silica gel breather, suitable for transformer including sufficient quantity of silica gel complete all as specified and directed for the following:
Transformer of capacity upto 100 KVA
Transformer of capacity above 100 KVA and upto 250 KVA
Transformer of capacity above 250 KVA and upto 400KVA
M&L PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete for all electrical structures complete all as specified and directed.
M&L PCC 1:2:4, type B-1 (wiring 20mm graded aggregate) as in coping of poles including necessary form work complete all as specified and directed.
Taking out trolley of vacuum circuit breaker 630/800 Amps 11 KV from the cabinet and opening top cover, de-carbonizing moving and fixed contacts if required, lubricating, inspecting the wiring of Micro processor EF/OC relay, tripping coil electrical and checking for manual/auto tripping system and placing back the breaker trolley in its original position complete all as specified and as directed by Engr-in-Charge. Note : The various unsv items required to be replaced shall be paid seperately under appripriate items.
Supply only replacement of Shunt trip coil of 24 V DC for 11 KV HT VCBs.
Supply only replacement of shunt closing coil for 11 KV HT VCBs.
Supply only replacement of spring charge motor , 230 v for 11 KV HT VCBs
Supply only replacement of 11 KV Resin cast single phase PT, 11 KV/RT3/110V/RT33: core 1: Class 1.0, burden : 50VA; with PT fuse
Supply only replacement of 11 KV resin cast single phase CT, CTR :50/5-5A, core1: class 0.5, burden : 15VA for metering, core 2 : class 5P10, burden : 15VA for protection, STC :18.4KA/1 Sec.
Supply only for replacemen of Numerical type protection relay having inbuilt features as follows : 50,51,50N,51N etc with Make : C&S or equivalent
Supply only replacement of Master trip relay.
Supply only replacement of Auxilary relay for transformer protection Make C&S or equivalent.
S&F in replacement Indication Lamp, 22.5 mm dia, 24V DC, of RED/Green /Yellow /Clear /Blue /White as required on site. Make: L&T or equivalent
Supply only in replacement of Heater 200W , 230 V AC . Make - APT Control or equivalent.
Callibration and service charge of microproccessor E/F and O/C relay of VCB complete and calibrating with portable relay test kit to set time and fault level and adjustment of setting with according to load & time with SPDC of Telangana for proper functioning complete all as specified.
S&F Cable Route Indicator for HT Cable with GI Plate and GI Pipe 80mm bore (dia) having 1.20 Metre long 'light grade' showing MES HT Cable/HT Joint and Voltage including necessary Earth Work and Cement Concrete 1:2:4 (20mm graded crushed stone aggregates) Block of size 20x20x20 Cm including taking out unserviceable Cable Route Indicator, complete all as specified and as directed.
Material and Labour painting of HT four pole structure of steel ISMB/Tubular pole/PCC pole after scraping thoroughly the existing rust/ dirt/ dust/ oil /grease and corroded paint from the steel surfaces of the structure including cross arms MS channel and applying two coats of aluminium paint over a coat of red oxide metal primer of approved quality including making of red and black strips above the coping upto a height of 1.5 Mtrs from the floor level with two coats of synthetic enamel paint complete all as specified and directed.
All as per item No 46 above but for two pole structure -ditto-.
All as per item No.46 above but for HT, 11 KV, 11 Meters pole -ditto-.
Supply & fix in replacement of temperature gauge 0 Degree Centigrade to 120 Degrees centigrade 100mm dia.
Supply & fix in replacement of head gasket (set of three) 3mm thick cork sheet
Supply & fix in replacement of oil level indicator glass in the conservator tank.
Material and labour Anti climbing devices spike type fabricated out of MS bars( round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified.
Isolating the transformer by carefully dismantling the HT / LT and earth connections, draining out the oil from transformer to the required level and storing in cleaned containers, opening the top cover and conservator tank from transformer, rectifying the defects and dismantling and repalcing burnt out LT/HT bushes and refixing back the same duly repalcing with GI nuts, bolts & washers of suitable size and making all HT /LT connections as per the original, re-filling the transformer oil to the required level and testing on completion foe capacity up to 315 KVA, 11KV complete all as specified and directed. NOTE: (i) LT /HT bush, trasformer oil for toping up will be measured and paid separetly appripriate under items.
Disconnecting the HT / LT connection, taking out the transformers form its plinth at any situation with the help of suitable crane and traporting the transformer to civil work shop for carrying out necessary repairs and bringing back and re-install in its original place of capacity upto 315 KVA, 11KV complete all as specified and directed.
Tacking out complete core from transformers tank of capacity upto 315 KVA, cutting and removing burnt out winding and re-winding the same with super enamelled copper conductor of existing gauge with insulating materials, applying varnish, drying in heating chamber , re-assembling the transformer as per the original and testing on completion all as specified and directed. Note: Shifting of transfermer from installed position to Civil work shop and back will be measured and paid separetly under appripriate items.
Dehyderation of transformer oil into the body/ conservator tank of transformer upto required level, Filteration of transformer oil at site of 11 KV / 433 V, indoor / outdoor transformer on any capacity installed at various locations with moblie type filtration plant to acheive minimum di-electric strength of 40 KV for 1 minute at 4 mm gap as per relevent I.S including testing and recording the values of di-electric strength of oil before and after filtration at site with transformer oil testing machine complete all as specified and directed. Note: Trasformer oil will be measured and paid separetly as "supply only" items of schedule.for topping up .
Supply only transformer oil for topping up in transformers oil.
Supply & fix in replacement of HT bushing of capacity 100 KVA, and upto 315 KVA
Supply only LT bush of capacity 100 KVA, and upto 400KVA
Opening the LT side cable box, disconnecting LT cables, removing unsv oil seal and supply and fix suitable oil seal and gasket for LT bushing of 11 KV /422 V transformers incl replacement rusted nuts & bolts for the transformers of capacity 100 KVA upto 400 KVA. complete all as specied and directed.
M&L for preparation of old painted surfaces of 11 KV / 433 V outdoor type distribution transformer, painting with spray gun through out externally with two coats of synthetic enamelpaint of approved colour and writing machine nubmer in white colour on black backgroung complete all as specied and directed by Engr-in-Charge.complete all as specified and directed for the following capacities of transformer :-
Transformer of capacity upto 100 KVA
Transformer of capacity above 100 KVA and upto 250 KVA
Transformer of capacity above 250 KVA and upto 400KVA
Disconnecting the HT / LT connection of a defective transformer of any capacity and shifting the trolly mounted mobile type transformer of capacity 315 KVA to the required location with tractor and making all necessary HT and LT connections, testing and return back to the original after completion of transformer repairs and reconnection.
Material & Labour for coarse aggreagate 20mm grade for all electrical structures (2 pole & 4 pole) after removing and clearing the vegitation, spreading & levelling the same in a required basis, complete all as specified and directed.
All as IteM No 63 above but 40mm grade coarse aggreagate -ditto-.
Cutting/pruning of tree branches along /around over head HT line at places within a radius of 2 mtr from fasted conductor and removing from site complete all as specified and directed
M&L Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strip 32×6mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to LT panel board as indicated including testing complete all as specified and as directed.
Sri Surya Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .