Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹35.8 L+₹4.9 L (15.7%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 3 | L3₹35.9 L+₹4.9 L (15.9%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 4 | L4₹37.1 L+₹6.1 L (19.8%)Rejected-Finance | L4 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 5 | L5₹37.2 L+₹6.2 L (20.1%)Rejected-Finance | L5 | Rejected-Finance BEING OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
27 May 2024, 6:00 pmClosed
GE NW NAVY NAGAR COLABA MUMBAI
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINTENANCE AND REPLACEMENT OF BURNT DAMAGED LIGHTINING CONDUCTOR DOWN CONDUCTORS EARTHINGS AVIATION LIGHTS REPAIR REPLACEMENT OF SECURITY LIGHT PATHWAYS LIGHTING SUBMAIN WIRING PVC TRUCKING AND ALLIED WORKS OF RASHI AREA UNDER GE NW
2024_MES_652783_1
8365/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹96,000
Yes
10 Jul 2024
7 May 2024
29 May 2024
7 May 2024
27 May 2024
21 May 2024
7 May 2024 - 27 May 2024
Amount
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 3.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.
Supply only the following spares suitable for LED street/Flood light fittings of make: Bajaj/Crompton/Phillips/Havells/Wipro/Orient/C&S/Polycab/Shakti
Electronic driver suitable for outdoor LED fitting of capacity 70 to 110 Watt.
Electronic driver suitable for outdoor LED fitting of capacity 30 to 60 Watt.
Surge protection device compatible with industrial & outdoor LED fitting of capacity 10 KV complete all as specified and as directed.
Surge protection device compatible with industrial & outdoor LED fitting of capacity 5 KV complete all as specified and as directed.
Dismantling LED light fitting of of Make:Bajaj /Crompton/ Phillips/ Havells/ Wipro/Orient/C&S/Polycab/Shakti of capacity 70 to 110 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Dismantling LED light fitting of of Bajaj/ Crompton/ Phillips/ Havells /Wipro/ Orient/C&S/Polycab/Shakti of capacity 30 to 60 W ,strip opening the elctronic driver, LED panel complete, identifying defective LEDs , replacement of defective LEDs complete including soldering, replacement of pitted control wiring from LED panel to driver etc complete, including testing and commissioning complete. Note : The rate quoted is not inclusive of taking down and refixing of street light fittings and shall be measured and paid separately under relevant schedule items
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 45 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. Make:Bajaj/Havells/Crompton/Wipro
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. Make:Bajaj/Havells/Crompton/Wipro
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. Make:Bajaj/Havells/Crompton/Wipro
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 9000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 90 watt, with ingress protection IP 65/66 and SPD of capacity 5 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. Make:Bajaj/Havells/Crompton/Wipro
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item. Make : M/S India Electric Pole Mfg Co MH /M/S Bombay Tubes/ M/S Singh Profile Pune
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item. Make : M/S India Electric Pole Mfg Co MH /M/S Bombay Tubes/ M/S Singh Profile Pune.
Supply, laying and commissioning, testing armoured heavy duty electric cable with copper conductor, 1100 volts grade of size 4 sqmm 4 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles/bottle lugs and taking out old u/s damaged cables. Make: Polycab/Havells/Plaza/Finolex
All as per item No-11.00 here in before but of size 2.5 sqmm 3 core including taking out old u/s damaged cables.
All as per item No- 11.00 here in before but of size 1.5 sqmm 2 core including taking out old u/s damaged cables.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation complete.
M&L for PCC 1:3:6 type C1 with 20 mm graded stone aggregate for coping of poles and stay including form work.
S & F astronomical Timelite distribution board IP-54 with contactor, relay and prewired, 32A, 3 pole, 230 Volt , and Astronomical programmable time switch with backup of 6 years, 28 memory locations, current capacity 16 A with one CO time switches for street light after taking out old one complete.
S & F digital time switch 3 phase of current capacity 16 Amps incl any type of accessories with suitable capacity of contactor after taking out unserviceable one.
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carrying capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed. Make: L&T/Legrand/ABB/Seimens
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using 4 mm dia GI earth wire bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
All as per Item No 19 but using galvanised iron strip 32×6mm as earthing lead and incased in and including 40 mm dia GI light grade pipe .
S&F loop-in/loop-out box of outer size size 225mmx295mmx122mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm aluminium clamp not less than, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
S&F street light bracket bend to shape made as required of 32/40mm dia 1 mtr long GI pipe light grade fixed to pole/wall with flat iron clamp of size 40x6mm two number with the help of nuts and bolts for fixing of street light fitting including making all electric connection including taking out old one complete all as specified and as directed.
M&L for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with white letters/ blackground etc complete all as directed
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
All as per above item No.24 above but exceeding depth 1.5 mtr and n exceeding 3 mtrs.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
Removing excavated material from the site of work and transporting out of Station/site of work suitable to the contractor all as specified.
Material and labour for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of size 250x250 mm having compressive strength of 35N/Sqmm, zig-zag (uni-paver) shape in flooring tested as per IS : 15658-2006, with and including layer of 50 mm thick natural river sand bed compacted complete as specified and directed.
Cutting existing road surfaces or hard standing 0.45 mtr depth (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces.
Material and labour for cement concrete type C-2, 1:3:6 (40mm graded stone aggregate), for coping and finished surface without using extra cement.
Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 150 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables.
All as per Item No-31.00 here in before but of sizes, 120 sqmm, 3.5 core.
All as per Item No-31.00 here in before but of sizes, 95 sqmm, 3.5 core.
All as per Item No-31.00 here in before but of sizes, 70 sqmm, 3.5 core.
All as per Item No-31.00 here in before but of sizes, 50 sqmm, 3.5 core.
All as per Item No-31.00 here in before but of sizes, 35 sqmm, 3.5 core.
All as per Item No-31.00 here in before but of sizes, 25 sqmm, 3.5 core.
All as per Item No-31.00 here in before but of sizes, 16 sqmm, 4 core.
All as per Item No-31.00 here in before but of sizes, 10 sqmm, 4 core.
All as per Item No-31.00 here in before but of sizes, 10 sqmm, 2 core.
M&L for 50mm dia High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface all as specified and directed.
All as per Item No-41.00 here in before but of sizes, 75mm dia
M&L for GI pipe ,light grade 50mm dia for road crossing or in hard standing for protection of cable above or under ground surface including taking out old one all as specified and directed.
Taking out old u/s and Supply, installing, testing and commissioning of LT feeder pillar box factory made cubical indoor type, fabricated out of 2.0mm thick CRCA sheet with angle iron base frame made of 40x40x6mm, 45cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415V 3 phase 4 wire weather proof with IP-66 protection, with separate hinge door for each compartment for incoming and out going MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with copper busbar (TPN), suitable double compression copper cable glands complete in all respect for bay work station and including provn of the following:- Note:- The panel shall be as per IEC/IS standards - IEC61439 1& 2 and CPRI certificate. Make of accessories :- ABB/Legrand/Siemens.
S&F MCCB 160 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
S&F MCCB 100 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 02 Nos,
S&F MCB SPN 32 Amps, 10 kA, - 60 Nos,
Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
Phase indicator lamp R,Y & B (Set of 3)- 01 Set
S&F Copper Bus bar 400 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N)
Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
Taking out old u/sand Supply, installing, testing and commissioning of LT feeder pillar box factory made cubical outdoor type, fabricated out of 2.00 5mm thick CRCA sheet with angle iron base frame made of 40x40x6mm, 45cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415V 3 phase 4 wire weather proof with IP-66 protection, with separate hinge door for each compartment for incoming and out going MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with copper busbar (TPN), suitable double compression copper cable glands complete in all respect for bay work station and including provn of the following:- Note:- The panel shall be as per IEC/IS standards - IEC61439 1& 2 and CPRI certificate. Make:- ABB/Legrand/Siemens.
S&F MCCB 100 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
S&F MCCB 63 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
S&F RCBO's 63 Amps, 4 Pole 300mA - 01 Nos,
S&F MCB SPN 40 Amps, 10 kA, - 01 Nos,
Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
Phase indicator lamp R,Y & B (Set of 3)- 01 Set
S&F Copper Bus bar 250 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N)
Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge.
Supply and fixing MCCB 100 Amps 25 KA , 50 Hz , Thermal magnetic release , ics=100%icu complete all as specfied and as directed.Make: Legrand/Havells/ABB
Supply and fixing MCCB 63 Amps 16 KA , 50 Hz , Thermal magnetic release , ics=100%icu complete all as specfied and as directed.Make: Legrand/Havells/ABB
Supply and fixing RCBO's 63 Amps 16 KA , 50 Hz , Thermal magnetic release , ics=100%icu complete all as specfied and as directed.Make: Legrand/Havells/ABB
Taking out old broken air termination, single pointed aluminium rod of any dia fixed over the GI Tube with the clamps.
Material & labour for CPT Cirprotec CPT-L ESE lightning rod with stainless steel body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of early streamer emission technology which will offer level 1 protection for up to 42 mtrs radius when mounted on the RCC concrete base on building at a height of 4.5 mtrs from the place to be protected complete all as directed by Engineer-in-Charge.
Taking out old, GI tube of any dia complete.
Supply and erection of mounting structure of 4.5 mtrs height with base plate suitabe for roof mounting on RCC concrete base on building complete all as directed by Engineer-in-Charge.
Taking Out old, broken aluminium strip of size 25 x 3mm fixed on walls/roof top with saddles and screws complete.
Supply & fixing of single core PVC insulated and PVC Innersheathed cable with aluminium conductor cable size 1x70 Sqmm 1100 Volt grade stranded aluminium conductor complete all as specified and as directed.
M&L for Galvanised steel tubes 25mm bore, light grade for protection of single core PVC insulated 70 sqmm unarmoured aluminium cable fixed on external wall surfaces of G+5 bldgs by proper clamping from roof to bottom complete all as directed.
M&L for PVC conduit pipe 25mm bore, medium mechanical stress for protection of single core PVC insulated 70 sqmm unarmoured aluminium cable fixed on external wall surfaces of G+5 bldgs by proper clamping from roof to bottom complete all as directed.
Supply and fixing 4 digital electromechanical lightning even counter in weather proof resistance including taking out old, U/S copper strip complete all as directed by Engineer-in-Charge.
Taking out old, broken/unserviceable earth testing point of any type complete
Supply and fixing test link box for each downconductor in order to disconnect the earth termination system to enable measurement of resistance.
Taking out old/unserviceable earthing complete with earthing material.
Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) including FRP earthpit chamber cover complete all as directed by Engineer-in-Charge.
M & L for snap-on trunking system including cover, angles bends and all accessories and fitting of size 50x80 mm fixing on wall complete all specified and directed.
Taking down old unserviceable aviation light fittings from roof surfaces of G+14 bldg and Supply & fixing of Twin LED aviation light 2 x 6 watt comprising of aluminium housing with polycarbonate diffuser, enclosed with glass cover in frame (with total lumen output not less than less than 100 lumens/Watt) with ingress protection IP 65 and surge protection device of 5 KV capacity etc incl necessary, angle iron supports , clamps etc for installation complete and testing on completion all as specified and as directed.
SHRI SAI ENTERPRISES
shree arihant constrution
shubham construction
NOEL ENGINEERS
M/s ASPIRE ENGINEERING ENTERPRISES
SHREE JAGDISH FURNITURE CO.
AGRAWAL ASSOCIATES
Shree Ayyappa Engineering
Nayana Electric Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .