Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L1 | Accepted-AOC AOC | |
| 2 | L2₹30.2 L+₹20,000 (0.67%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹30.3 L+₹30,240 (1.01%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹30.8 L+₹84,875 (2.83%)Rejected-Finance 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹31.8 L+₹1.9 L (6.17%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹47 L
EMD Value
₹96,000
Closing Date
4 Sept 2024, 6:00 pmClosed
BENGALURU
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
REPAIR REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS FIXTURES RENEWAL OF BLDG EARTHING AND OTHER CONNECTED ITEMS IN RO OTM ACCN MEG AREA UNDER GE N BANGALORE
2024_MES_665060_1
8476
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BENGALURU
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH BANGALORE
₹96,000
Yes
14 Oct 2024
10 Jul 2024
11 Sept 2024
10 Jul 2024
4 Sept 2024
24 Jul 2024
10 Jul 2024 - 24 Jul 2024
Amount
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, call bell socket or power circuits) complete and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete concealed with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes suitable for normal/modular concealed on walls including plastic/hylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :- One light point controlled by one switch
All as per item No. 2 above but for One fan point controlled by one switch/regulator
All as per item No. 2 above but for One light point controlled by 2 way switch
All as per item No. 2 above but for One 3 pin socket out let 5 Amps on independent board
All as per item No. 2 above but for One bell / buzzer point controlled by bell push
All as per item No. 2 above but for One 3 pin socket out let 5 A on same board
All as per item No 2 but concealed wiring drawn through existing PVC conduit. One light point controlled by one switch
All as per item No. 8 above but for One fan/Exhaust point controlled by one switch/regulator
All as per item No. 8 above but for One light point controlled by 2 way switch
All as per item No. 8 above but for One 3 pin socket out let 5 Amps on independent board
All as per item No. 8 above but for One bell/buzzer point controlled by bell push
All as per item No. 8 above but for One 3 pin socket out let 5 A on same board
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick GI/MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories all as specified and as directed. Note: 3 runs of cable will be measured as unit length.
Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick GI/MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following One light point controlled by one switch
All as per item No. 16 above but for One fan point controlled by one switch/regulator
All as per item No. 16 above but for One light point controlled by 2 way switch
All as per item No. 16 above but for One 3 pin socket out let 5 Amps on independent board
All as per item No. 16 above but for One bell/buzzer point controlled by bell push
All as per item No. 16 above but for One 3 pin socket out let 5 A on same board
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete surface type with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories including GI / MS branded sunken boxes suitable for normal / modular concealed on walls including plastic / hylam laminated sheet top cover 3 mm thick / modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :- One light point controlled by one switch
All as per item No. 24 above but for One fan point controlled by one switch/regulator
All as per item No. 24 above but for One light point controlled by 2 way switch
All as per item No. 24 above but for One 3 pin socket out let 5 Amps on independent board
All as per item No. 24 above but for One bell/buzzer point controlled by bell push
All as per item No. 24 above but for One 3 pin socket out let 5 A on same board
Point wiring complete surface type with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing modular / Normal switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 02 to 30 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch / socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be paid measured and paid separately.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth, all as specified and as directed.
S&F in repair LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No. BCLAB 20 W LED P or equivalent Makes & model of CA
S&F in repair LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as specified and directed. Make: Bajaj, Cat No.BCLSB 10W WH or equivalent Makes & model of CA
S&F in repair 2' x 2' Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36L LED WH GX MT or equivalent Makes & model of CA
S&F in repair 2' x 2' Surface mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36L LED GX CW or equivalent Makes & model of CA
Supply and Fix in repair Modular switch 1 way 6A,1 module
Supply and fix in repair Modular switch 1 way 16A, 1 module
Supply and fix in repair Modular switch 2 way 6A,1 module
Supply and Fix in repair Modular Bell push 6A 1 module
Supply and fix in repair modular Socket, 6A - 2/3 pin combined 2 module
Supply and fix in repair modular Socket 6A/16A - 2/3 pin combined 2 module,
Supply and fix in repair modular type Fan step regulator, 120W - 2 module
S&Fin repair of of Switch piano flush button single pole two way 5 Amps all as specified and as directed.
S&F in repair of Angle holder PVC / polycarbonate type all as specified and as directed
S&Fin repair of switch piano flush type single pole one way 5 Amps
S&F in repair of switch socket combination 5 pin 2 in 1, 5 A Flush type all as specified and as directed
S&F in repair of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed
S&F in repair of bell push flush type 5A all as specified and as directed .
S&F in repair of MCB SPN 240 volts 32/40 Amps complete all as specified and as directed
S&F in repair of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed
S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed
S&F in repair of MCB TPN 415 volts, 10KA 'C' curve 100 Amps complete all as specified and as directed
S&F in repair of MCB DB SPN 4 way double door horizontal type 240 volts with 200 Amps rated busbar as specified and as directed.
S&F in repair of MCB DB SPN 8 way double door horizontal type 240 volts with 200 Amps rated busbar as specified and as directed.
S&F in repair of MCB DB TPN 4 way with double door horizontal type 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed.
S&F in replacement of Vertical DB TPN 8 way suitable for MCCB upto 125 Amps as I/C, double door type 415 volts, IP :54 protection, door, earthing, isolated neutral bar, mechanical impact strength IK 09 with insulated bus bar assembly, pre punched knockout, wire set with 16 sqmm phase and 10 sqmm neutral cable independent shield along with 200 Amps Ammeter and 500 Amp voltmetre including RYB lamps. Make : Indoasian Cat No. 812048 or equivalent make of CA
S&F in repair of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
S&F in repair of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed
S&F in repair of Ding Dong bell AC 230 volts single pole.
Provision of new sub main wiring 1100 volts grade multi stranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed inculding taking down the unsv submain complete. Note:- 3 runs of cable and one run of PVC conduit will be measured as unit RM.
Provision of new sub main wiring 1100 volts grade multi stranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed inculding taking down the unsv submain complete. Note:- 3 runs of cable and one run of PVC conduit will be measured as unit RM.
Provision of new sub main wiring 1100 volts grade multi stranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed inculding taking down the unsv submain complete. Note:- 3 runs of cable and one run of PVC conduit will be measured as unit RM.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed including dismantling and taking down old Earthing plates.
S&F LED lamp suitable to fit in angle holder of capacity 09 watt. Make: Bajaj or equivalent in CA.
Supply and fixing in repair 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate diffuser with IP 66 protection including taking out old fittings. Make:- Bajaj, Cat No.:- ENXT P 30L WH PO PC SD or Equivalent Makes & model of CA.
S&F in repair Bracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust / wall mounting fans complete all as specified and as directed.
S&F in replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20 Amps.
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable legs including taking down the unsv cable complete. 4 C x 10 Sqmm
All as per item No. 69 above but for 4 C x 16 Sqmm
All as per item No. 69 above but for 3.5 C x 25 Sqmm
Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables on trenches etc complete all as specified and as directed.
Returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed
Removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed
M & L for sand cushioning with of M-Sand 23 cm thick under and above the cable complete all as specified punned down to 18 cm thick and as directed. Note:- Only punned thickness will be measured for payment
S & L sub class 'B' burnt bricks for cable protection complete as specified as directed
M&L for GI tubing light grade 40mm dia with all accessories for cable protection fixed on poles / bldgs / road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed.
S&F in repair Bulk Head Fitting suitable for indoor application of 10 watt. Make & Model No: Bajaj Cat part No: BIBWP 10W LED or its equivalent makes of CA.
S&F in repair slim down light / round / square / recess / surface mounted with die cast aluminium housing complete of 9/12 watts
RRK PROJECTS (BID ID -3081376)
Varsha Enterprises (BID ID -3080801)
Vasavi Electricals (BID ID -3080494)
RAMSON TRADERS (BID ID -3083164)
KRD ASSOCIATE (BID ID -3081730)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .