Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC L1 accepted | |
| 2 | L2₹10.7 L+₹28,404.65 (2.73%)Rejected-AOC | L2 | Rejected-AOC rejected due to other L agency | |
| 3 | L3₹10.9 L+₹49,326.29 (4.73%)Rejected-AOC FLAT NO 3 NEW HOUSING BOARD COLONY BARNALA ROAD SIRSA 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-AOC rejected due to other L agency | |
| 4 | L4₹11.0 L+₹55,999.13 (5.37%)Rejected-AOC C 128 BASEMENT ROSEWOOD CITY SECTOR 49 GURUGRAM HARYANA 122018 | GURUGRAM | GURUGRAM | HARYANA | 122018 | L4 | Rejected-AOC rejected due to other L agency | |
| 5 | L5₹11.7 L+₹1.3 L (12.5%)Rejected-AOC | L5 | Rejected-AOC rejected due to other L agency |
Tender Value
₹11.8 L
EMD Value
₹24,000
Closing Date
28 Jun 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer PD1 PWD BandR Branch Sirsa
Construction of Rain Water Harvesting Tank in Govt. ITI at Chautala 3 Nos. in Sirsa Distt.
2021_HRY_176621_1
Construction of Rain Water Harvesting Tank in Govt
Open Tender
Civil Works - Buildings
Item Wise
60 days
Sirsa
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
₹24,000
Yes
26 Aug 2021
19 Jun 2021
29 Jun 2021
19 Jun 2021
28 Jun 2021
19 Jun 2021
120 days
Amount
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per clause 304 of MORT&H specifications Ordinary soil,Depth 3 m to 6 m (HSR 15.1.1.2)
Providing and Laying in position cement concrete of specified grade excluding the cost of centering and shuttering – all work below plinth level and upto floor IV level (HSR 6.1.6) 1:4:8 (1 Cement : 4 Coarse Sand (Zone-III) : 8 Graded cum stone aggregate 40 mm nominal size)
Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS : 2800 (Part I) including collecting samples from different strate, preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools plants & machineries required for the job, all complete as per direction of Engineer-In-Charge, upto 90 metre depth below ground level (HSR 33.6.1.1) All types of soil 300 mm dia
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15” landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-III) : 3 Graded Stone aggregate 20 mm nominal size) (HSR 6.16)
Steel reinforcement for RCC work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level (HSR 6.33.6) Thermo – Mechanically Treated bars of grade Fe-500D or more Note: - Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps, wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as require (HSR 13.29.1) In Stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all completed
Providing and placing in horizontal layers filtering media screened washed and cleaned as described below: - (HSR 20.52) Top layer Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4 mm with uniformity coefficient 2.0 to 3.0) from Ghaggar or other approved source (HSR 20.52.1)
Second layer Coursed sand screened, cleaned and washed and graded from 3 mm to 6 mm (from Ghaggar or approved equivalent quarry) (HSR 20.52.2)
Third layer Bajri (coursed) screened and washed graded from 20 mm to 25 mm (from Ghaggar or approved equivalent quarry) (HSR 20.52.3)
Bottom layer (e) Broken stone, screened, washed and graded from 50 mm to 75 mm (from Ghaggar or approved equivalent quarry) (HSR 20.52.5)
Wire crates 1.20 x 1.20 m from all directions of GI wire, filled with boulders with square-cut faces, against the wire (HSR 16.38.1) 4 mm dia GI wire, 25 cm x 7.50 cm mesh (diagonal wise)
Supplying and fixing CI cover without frame for manholes (HSR 22.200.1) 455 x 610 mm rectangular CI cover (light duty) the weight of the cover to be not less than 23 Kg
Providing and Fixing on wall face un-plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382. Leaving 10 mm gap for thermal expansion, (i) Single socketed pipes (HSR 9.57.3) 150 mm diameter
Providing fixing PVC Rain water pipe 6Kg Pressure of ISI mark in cement mortar during masonry work. 200 MM dia PVC pipe perforated 6 Kg. Pressure i/c PVC net (NS)
Providing and Fixing on wall face un-plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382. Leaving 10 mm gap for thermal expansion, (i) Single socketed pipes (HSR 9.57.2) 110 mm diameter
Brick work with common work burnt clay non-modular bricks of class designation 7.5 in foundation and plinth (HSR 7.21.1) Cement mortar 1:4 (1 Cement : 4 Coarse Sand)
CEMENT PLASTER (IN FINE SAND): 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (HSR 11.5.3)
Constructing brick masonry inspection chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12 mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement RCC 1:2:4 slab 100 mm thick / cement concrete topping, 50 mm thick with 455 x 455 mm / 455 x 610 mm inside light duty CI inspection chamber cover and frame weight as per ISI specification painted with 3 coats of black bitumastic superior paint complete as per standard design (HSR 21.84.1) Size 450 x 450 mm inside (with 455 x 455 mm cover and frame light duty single seal weighing 20 Kg with CC topping)
Extra for every 0.30 metre depth of inspection chamber (HSR 21.85.1) 450 x 450 mm inside
Atul Gupta Contractor
LS CONTRACTOR
RAJENDER CONTRACTOR
The Aapni Co-Op Labour and Construction Society Limited
Wallet Solutions
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .