Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.4 L+₹91,825 (6.34%)Rejected-Finance | L2 | Rejected-Finance Quoted amount more than L1 | |
| 3 | L3₹16.4 L+₹1.9 L (13.1%)Rejected-Finance | L3 | Rejected-Finance Quoted amount more than L1 | |
| 4 | L4₹16.8 L+₹2.3 L (16.0%)Rejected-Finance | L4 | Rejected-Finance Quoted amount more than L1 | |
| 5 | L5₹17.0 L+₹2.5 L (17.1%)Rejected-Finance | L5 | Rejected-Finance Quoted amount more than L1 |
Tender Value
Refer Docs
EMD Value
₹29,500
Closing Date
5 Oct 2020, 12:00 pmClosed
Lt Col Vipin V Kumar
Garrison Engineer Ranchi, 7th Club Road, PIN-834001
SPL REPAIR OF ELECTRIFICATION WORK TO BLDG NO T-18A (OFFR MD ACCN) AND T-92 (FSH) AT ENGR LINE AREA UNDER GE RANCHI
2020_MES_379553_1
8400/1095/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class E cat b (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹29,500
Yes
27 Oct 2020
21 Sept 2020
7 Oct 2020
22 Sept 2020
5 Oct 2020
28 Sept 2020
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete with screws, gutties including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets, light fittings, etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, ceiling, etc.to match with existing surfaces, all as specified and directed.
Material and labour for point wiring (concealed) with 1.5 Sqmm PVC insulated FR unseathed multi stranded copper conductor cable 1100 volts confirming to IS-694-1990 and one run continious earth wire with 1.5 Sqmm stranded core PVC insulated unsheathed FR copper conductor confirming to IS-6941990 in PVC Conduit concealed type incl PVC conduit/fitting etc, switch,sockets fixed to modular MS boxes and metal colour plate and all as specified and directed :-
One light point controlled by one switch
One fan/exaust point controlled by one switch
One 3 pin socket outlet 5 Amps, on the same board with other switches
One socket 3 pin outlet 5 amp on independent board
One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size
All as per item No 2 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 4 sq mm including one run of 4 sq mm copper conductor as earth contnuity wire, all as specified and directed.
S&F Modular switch 1 way 6A, 1 module, all as specified and directed.
S & F modular white cover plate with frame,2 module
S & F modular white cover plate with frame,3 module
S & F modular white cover plate with frame,4 module
S & F modular white cover plate with frame,6 module
S & F modular white cover plate with frame,8 module
S&F ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body, ac, 230 volts, complete all as specified and directed.
S&F in replacement modular type electronic fan regulator complete all as specified and as directed
S&F Socket outlet modular 2 in 1, 3 pin, 5A multipurpose, flush type, complete all as specified and as directed.
S&F modular Switch socket outlet 3 pin 5 amp' flush type multipurpose, flush type, complete all as specified and as directed.
S&F modular Switch socket outlet 3 pin, 15 amp, flush type flush type universal, complete all as specified and as directed
S&F Modular Bell push 6A 1 module, flush type, complete all as specified and as directed
S&F bell ding dong type, AC, 230 V, single pole, complete all as specified and as directed
Taking down and Refixing only ceiling fan and connecting up with round flexible copper conductor Flame retardant PVC insulated and sheathed 3 core multi stranded of size 0.50 Sq mm from ceiling rose to connector of C / Fan complete with testing all as specified and directed by Engr in Charge .( Note : 1. Cost of Flame retardant PVC insulated unsheathed multi stranded round flexible copper conductor 1100 V grade 3 Core 0.5 Sqmm from ceiling rose to connector of C / Fan is deemed to be included in the rate quoted.
M&L for sub main wiring with two single core FR 6 Sqmm copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including FR 6 Sqmm PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly all as specified.( Note :- Three runs of 6 sqmm copper conductor shall be measured as one unit length. ie Phase, Neutral, Earth)
S&F in replacement sheet metal enclosure for DB's for using MCB, MCB DB, single pole and neutral 8 ways double door with 200 amps rated bus bar 240 volts and all accessories and complete all as specified and as directed
S&F in replacement of MCB single pole and neutral 63 amps, 240 Volts
S&F in replacement of MCB 6 to 32 amps single pole 240 Volts
Supply and fix exhaust fans AC single phase 230/240 V of size 300mm sweep with louver complete all as specified and as directed
Supply and fix LED tube light alongwith fixtures, 22W complete all as specified and as directed
Supply and fix LED down lighter '2'x2', 35W complete all as specified and as directed
Supply and fix LED security light 35/36 W IP 65 complete all as specified and as directed
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3 1/2 core
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any kind soil complete all as specified and directed.
Returning filling in including spreading, leveling and well ramming in layers not exceeding 25 cm each layer of any kind of soil
Removing surplus excavatged material from site not exceeding 50 mtrs from starting point and depositing where ditected at level not exceeding 1.50 mtr above the starting point.
Sand cushioning for cables complete all as specified and directed.
Material and labour for old size brick well burnt, laid flat for cable protection complete all as specified and directed.
Supply and fix post top lantern light fitting for 70 Watt SV lamp complete with all accessories.
S&F fans ceiling complete with elecronic type regulator and accessories 230 V, 1200 mm sweep BEE 5 star rated.
M/S Manoj Kumar Sinha
M/s Dwarika Nath Singh
OM SAI CONSTRUCTION
jai maavindwashni sales & supply
M/S JAI MATA DEE CONTRUCTION CO.
BHARATI ENTERPRISES
india trading company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .