| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹16.1 L+₹72,000 (4.67%)Rejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Not the lowest e-tenderer | |
| 3 | L3₹17.7 L+₹2.3 L (14.9%)Rejected-Finance | L3 | Rejected-Finance Not the lowest e-tenderer | |
| 4 | L4₹19.8 L+₹4.4 L (28.7%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
₹17.8 L
EMD Value
₹35,600
Closing Date
10 May 2023, 6:00 pmClosed
Shri T Rajasekharam,IDSE
HQ Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
SPECIAL REPAIR REPLACEMENT OF FIRE FIGHTING PUMP SETS AGAINST BER EQUIPMENTS AND CONNECTED ITEM UNDER GE WEST COLABA MUMBAI
2023_MES_589323_1
85054/W/E8
Open Tender
Civil Works
Item Rate
120 days
Garrison Engineer (W) Colaba
Please refer tender documents
7 documents required · 7 mandatory
₹500
Garrison Engineer (W) Colaba
₹35,600
Yes
4 Jul 2023
13 Apr 2023
11 May 2023
13 Apr 2023
10 May 2023
28 Apr 2023
13 Apr 2023 - 3 May 2023
Amount
Dismentalling ,taking down/out old UNSV pumpsets of any capacity /any type by carefully including base frame, demolition of foundation and transporting , and depositing to MES Store yard .
Supply, Installation, Testing, Aligning and proper leveling & commissioning of Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft working parts (EN-8) mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 90m Head, 1620 LPM discharge , directly coupled to totally enclosed fan cooled squirrel cage A.C. induction motor of suitable capacity of operate on 3ph, 415V & 50 cyc A.C. with B class installations & both the pump & motor are to be Erected on common M.S. base plate, and required size MS channel suitable rigid foundation, nut bolt washer, coupling guards and anti vibration rubber pad and accessories all as specified and directed. Make: Kirloskar/KSB/Mather & Platt.
Supply, Installation, Testing, Aligning and proper leveling & commissioning of Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft working parts (EN-8) mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 70m Head, 2280 LPM discharge , directly coupled to totally enclosed fan cooled squirrel cage A.C. induction motor of suitable capacity of operate on 3ph, 415V & 50 cyc A.C. with B class installations & both the pump & motor are to be Erected on common M.S. base plate, and required size MS channel suitable rigid foundation, nut bolt washer, coupling guards and anti vibration rubber pad and accessories all as specified and directed. Make: Kirloskar/KSB/Mather & Platt.
Supply, fix and jointing in repairs duly welded heavy grade MS ERW pipe with 150mm dia class 'C' conforming to IS 1239:2004 in trenches / wall / floor including all fittings, such as MS flanges, coupling, bends, elbow, tee, nuts, bolts, washers etc with two coats of synthetic enamel paint in red colour over red oxide primer for pipe and fire hydrant stand post with welding, screwing joint etc complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in repair foot valve CI with ISI marked heavy duty conforming to IS 4038 of rubber ball lock type including all accessories regular little rubber gasket, nut & bolts, washers etc complete of size 150mm dia complete all as specified and directed at site.
Supply & Fix in repair CI Sluice valve with flanged ends, cast iron body flanged and drilled end non rising type. HT bronze spindle with nuts, class PN-1.6 suitable for 150 mm bore as per IS 14826, ISI marked including all joints with rubber or fibre board, bolts and nuts, washers etc complete including taking down existing all as specified and directed by Engineer-in-Charge.
M & L for earthing complete with galvanised earth plate electrode 60cmx60cmx6.15mm thick, burried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to GI strip 32x6 mm as earthing lead by means bolts and nuts check nuts and washers galvanised iron and connected to main switch board including watering arrangement with PCC chamber, MS funner with wire mesh CI cover with frame etc including necessary excavation in any type of strata, returning filling removal of soil outside MD land filling of charcoal and salt complete includiong taking out existing all as specified and directed and testing on completion all as directed.
Supply and fix in repair non return valve ISI mark complete of size & PN 1.6 grade with necessary fittings such as rubber gaskets, nuts, bolts, washers complete including dismantling / taking out old defective / unserviceable non return valve of 150mm bore size
GANGAJAL
Minal Engineers
AGRAWAL ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .