Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹28.9 L+₹3.9 L (15.8%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹29.4 L+₹4.4 L (17.8%)Rejected-Finance 121004 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹31.4 L+₹6.4 L (25.8%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹36.9 L+₹11.9 L (47.6%)Rejected-Finance DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
28 Nov 2024, 6:00 pmClosed
GE (AF) SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR / MAINT OF COOLING APPLIANCES AND OTHER CONNECTED E/M WORKS AF STN SULUR
2024_MES_682168_1
8712/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (AF) SULUR
₹99,000
Yes
13 Jan 2025
1 Nov 2024
30 Nov 2024
1 Nov 2024
28 Nov 2024
15 Nov 2024
1 Nov 2024 - 11 Nov 2024
Amount
SCHEDULE A BOQ
Taking out, inspection, checking adjustment and minor repair of unserviceable refrigerator 165/180/175/210/260/280/300/310/320/ 335 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose electrical connection etc., cleaning, condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of refrigerating gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 260 to 300 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning all as specified and as directed. Note:Topping up of gas will be measured and paid seperately
Supply and fixing in repair of hermetically sealed new compressor for 260 to 310 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 260 to 310 litres. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and fixing in repair of condensing coil for refrigerator of capacity 260 to 310 Ltr complete all as specified and directed.
Supply and fixing in repair of Chiller tray suitable for Refrigerator of any make, 260 to 310 litres capacity, complete all as specified and as directed.
Supply and fixing in repair of Evaporator coil, suitable for refrigerator of 260 to 310 ltrs any make size and type complete all as specified and as directed.
S & F in repair Vegetable tray suitable for Refrigerator of any make, 260 to 310 litres capacity, complete all as specified and as directed.
Supply and fixing in repair of ice superior quality plastic/PVC Ice cube tray for refrigerator of capacity 260 Ltrs to 310 ltrs complete all as specified and directed.
Supply and fixing in repair of in repair electric bulb 20 watt 230v threaded type for refrigetator of Capacity 260 ltrs to 310 ltrs complete all as specified and directed.
Supply and fixing Freezer compartment including door and accessories suitable for refrigeratorr 280, 300, 310 and 320 ltrs capacity refrigerator and including taking existing unserviceable one complete all as specified and as directed.
Supply and fixing PVC shelf transparent type of tough plastic suitable for refrigerator of capacity 300 ltrs complete including taking down existing unserviceable one all as specified and as directed.
M&L for pressure testing and rectifying the leakage found in the system of refrigerator of capacity 165 to 260 litres including vacuuming and charging the refrigerant (R 134a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed. Note:Topping up of gas will be measured and paid seperately
Supply and fixing in repair of hermetically sealed new compressor for 165 to 255 Ltr capacity of refrigerator including filling of refrigerant suitable and testing complete by disconnecting the electrical and refrigerant connection of defective sealed unit of Refrigerator compressor of capacity 165 to 255 litres complete all as specified and as directed. Make :- As per existing make of Refrigerator Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and fixing in repair of condensing coil for refrigerator of capacity 165 to 255 Ltr complete all as specified and directed.
Supply and fixing in repair of Chiller tray suitable for Refrigerator of any make, 165 to 255 litres capacity, complete all as specified and as directed.
Supply and fix in repair magnetic beading for refrigerator of cap 165 ltrs to 335 ltrs complete all as specified and directed.
Supply and fixing in repair of Relay, box type, suitable for refrigerator of any make 165 to 335 litres capacity complete all as specified and as directed.
Supply and fixing in repair of Evaporator coil, suitable for refrigerator of 165 to 255 ltrs any make size and type complete all as specified and as directed.
M & L for preparing the old painted surface of refrigerator of capacity 165 litres to 335 litres and spray painting with synthetic enamel paint of approved colour complete all as specified and as directed
Note for item No 20 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
Supply and fixing in repair of Vegetable tray suitable for Refrigerator of any make, 165 to 255 litres capacity, complete all as specified and as directed
Supply and fixing Freezer compartment including door and accessories suitable for refrigerator 165/175 ltrs capacity refrigerator and including taking down existing one complete all as specified and as directed.
Supply and fixing in repair of Thermostat, suitable for refrigerator of any make 165 to 335 litres capacity complete all as specified and as directed
Supply and fixing in repair of Gasket, suitable for door of Refrigerator of any make, 165 to 260 litres capacity,complete all as specified and as directed
Supply and fixing of Multi capacitors 2 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Filter of refrigerator including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Timer and sensor of Refrigerator including taking down existing unserviceable one complete all as specified and as directed as per Make of Refrigerator
Supply and fixing Over load protector for refrigerator including taking down existing unserviceable one any description complete all as specified and as directed..
Supply and fixing Copper capillary tube suitable for refrigerator including taking down existing unserviceable one, any description complete all as specified and directed.
Supply and fixing Starting relay suitable for refrigerator including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Multi capacitors 4 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed
Supply and fixing Multi capacitors 2.5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
M&L for pressure testing and rectifying the leakage found in the system of Deep freezer of capacity 320 litres including vacuuming and charging the refrigerant Refrigerant gas R-134 a gas to the desired pressure and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately
Supply and fixing in repair of hermetic sealed new compressor 1/6 HP suitable for deep freezer of capacity 320 ltr including disconnecting the electrical and refrigerant connection of defective sealed unit of deep freezer 320 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and fixing Copper capillary tube of Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Supply and fixing Condenser fan motor of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Thermostat for Deep freezer including taking down existing unserviceable one complete all as specified and as drected.
Supply and fixing Starting relay of Deep freezer including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Filter for Deep freezer including taking down existing unserviceable one complete all as specified and as directed
Supply and fixing Over load protector for Deep freezer including taking down existing unserviceable one, any description complete all as specified and as directed.
Supply and charging of Refrigerant gas, (R-22/R-134(a)/R-407(c)) Freon suitable for cooling equipments like water cooler, refrigerator, deep freezer air conditioner etc of any type and capacity complete all as specified and as directed
S & F multi capacitors 60 µfd for cooling appliances and including taking down existing one complete all as specified and as directed.
S & F multi capacitors 50+5 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
M&L for dismantling the transformer from the voltage stabilizers of following capacity and removing the old / burnt transformer and replaced with new transformer complete all as specified and as directed
S & F in repair of following spare parts for 1 KVA to 2 KVA capacity voltage stabilizers complete all as specified and as directed
(a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
Taking out, inspection, checking adjustment and minor repair of unserviceable water cooler 40/80/60/120/150/200 ltr capacity of any type any make for repair/ replacement of defective parts such as condenser, PVC pipe, loose water tap, float valve, loose electrical connection etc., cleaning condenser unit of foreign particle and descaling with carbon di oxide gas to ensure smooth flow of water cooler gas, reassembling the appliance, testing and placing in original position complete all as specified and as directed by Engineer-in-Charge. Note :- Repair/ replacement of unserviceable parts shall be measured and paid separately complete all as specified and as directed by Engineer-in-Charge.
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 150 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately
Supply and fixing in repair of hermetic sealed new compressor for water cooler 150 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 150 ltr and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and as directed Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and fixing in repair of Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 150 ltr capacity, complete all as specified and as directed
Supply and fixing in repair of Door gasket suitable for lid of water cooler upto 150 litres capacity, complete all as specified and as directed
Supply and fixing in repair of Stainless steel tray suitable for water cooler of 150 Litres capacity complete all as specified and as directed
Taking down corroded bottom portion of water cooler of 150 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour complete all as specified and as directed
M&L for preparing the old painted surface of the water coolers of capacity cap 150 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed
Note for item No 64 & 65 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 60/120 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately
Supply and fixing in repair of hermetic sealed new compressor for water cooler 60/120 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 60/120 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Supply and fixing Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 60/120 litres capacity, including taking down existing one complete all as specified and as directed
Supply and fixing in repair of Candle (filter) 10” size incl taking down existing one complete all as specified and as directed
Supply and fixing in repair of Self closing push type Bib tap 15mm dia made out of cast copper alloy chromium plated suitable for water cooler conforming to ISI mark, including testing and leak proof etc.complete all as specified and directed.
Supply and fix in repair PVC connection pipe 450mm long 15 mm dia with brass unions with washers on both the ends complete all as specified and as directed
Supply and fixing ball brass valve high pressure 15mm dia complete fitting such as PVC polythene ball, layer check nut washer etc for water cooler of any capacity including taking down existing one complete all as specified and as directed
Supply and fixing gun metal gate valve 15mm dia including GI nipple including taking down existing one complete all as specified and as directed
Supply and fixing in repair of PVC drain out pipe 30mm dia bore as per existing including providing necessary GI clamps, nut bolt etc.complete all as specified and as directed
M&L for pressure testing and rectifying the leakages found in the system of water cooler of capacity 40/ 80 litres and vacuuming and charging refrigerant gas (R-134a) and filling new compressor oil etc. complete for satisfactory functioning complete all as specified and as directed Note:Topping up of gas will be measured and paid seperately
Supply and fixing in repair of hermetic sealed new compressor for water cooler 40/80 ltr/Hr cooling capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of storage type water cooler of capacity 40/80 litres and connection of all pipe line & charging of refrigerant and testing complete all as specified and directed. Make :- As per existing make of Water Cooler Note:- Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
M&L for repairing the leakage in the steel water tank of water cooler of any capacity by welding brazing/ soldering complete all as specified and directed.
Taking down corroded bottom portion of water cooler of 40/80 litres capacity and provision of 14 gauge MS sheet with suitable size angle iron frame work duly welded to the body of the water cooler including two coats of synthetic enamel painting over a coat of red oxide primer to match the existing colour complete all as specified and as directed
Note for item No 85 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
Supply and fixing in repair of Stainless steel tray suitable for water cooler of 40/ 80 litres capacity complete all as specified and as directed
Supply and fixing in repair of Evaporator coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity complete all as specified directed.
Supply and fixing in repair of Electric condensor Fan motor, AC 230 volt, single phase with recommended RPM etc suitable for water cooler of any make of 40/80 litres capacity, complete all as specified and as directed
Supply and fixing in repair of Condensing coil suitable for water cooler of capacity 40/80 ltr/hr cooling capacity complete all as specified directed.
Supply and fixing Multi capacitors 45 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
Supply and fixing Multi capacitors 6 µfd for cooling appliances including taking down existing unserviceable one complete all as specified and as directed.
M&L for preparing the old painted surface of the water coolers of capacity up to 40/80 Litres and spray painting with synthetic enamel paint over one coat of red oxide primer including replacement of worn out nut, bolt, washer, screw and writing MES No and capacity complete all as specified and as directed
Note for item No 99 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
Supply and fixing in repair of filter for water cooler of any size any make complete all as specified and as directed.
Supply and fixing in repair of Carbon (filter) 12” size incl taking down existing one complete all as specified and as directed.
Routine repair and annual maintenance of Aqua guards installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed by Engineer-in-charge, for the any models / types, for 09 month period of each aqua guard - 18 Nos Notes :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 09 months.
Supply and fixing PCB Card 12 Volt of DC capacity for Aquaguard incl dismantling old unsv and including taking down existing one complete all as specified and directed.
Routine repair and annual maintenance of best water doctor of tank capacity 25/ 44 ltrs installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed by Engineer-in-charge, Make :- Best water doctor model No. HIMA-5NC of flow rate 100 ltr/ hr - 2 Nos Notes :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 09 months.
Routine repair and annual maintenance of best water doctor of tank capacity 40/ 80 ltr installed in various locations including attending breakdown calls, monthly routine maintenance including replacement of carbon , micron filter as and when required and changing of defective spares, quarterly cleaning of Aqua Guard internally and externally, changing of filters complete all as specified and as directed by Engineer-in-charge, Make :- Best water doctor model No. UV 7 NC of flow rate 200 ltr/ hr - 9 Nos Notes :- (a) The contractor shall make AMC contract with the authorised service agency of best water cooler and repair/ maint shall be carried out through the authorised person of OEM only. (b) The rate quoted shall deem to be included for carried out all repairs to water cooler noticed during the period 9 months.
S & F PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and as directed.
M&L for Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance alongwith blower assembly filter and other components including checking electrical connections complete all as specified and as directed
M&L for blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections complete all as specified and as directed
M & L Periodical servicing, calibaration and maintenance of composite synchronous panel of Make: Jackson PCC 3.3 based on auto load management, auto load sharing, auto synchronization panel suitable for 3x 810 KVA stand by DG set comprising of following components:-
INCOMER:- (i) Air circuit breaker 1600A, 415V, 50 Hz -03 Nos (ii) Engine start/stop push button (iii) Digital temperature scanner - 03 Nos (iv) Annunciator -03 Nos (v) Electric buzzer (hooter) - 03 Nos (vi) Digital multifunction meter - 03 Nos (vii) DC volt meter - 03 Nos (viii) indicating LED lights for 3 phase, R, Y, B, Breaker - ON/ OFF, Neutral - ON/OFF, battery charger ON/OFF etc
Note for Item No 116 to 119 :- (i) The unit quoted rate shall deem to be included to carried out all repairs noticed during the period. (ii) Repairs/ maintenance shall be carried out through the authorised service agency only as per instructions recommended by the original manufacturer. (iii) The authorised service agency must be attended as and when called for urgent nature of repair of synchronous panel irrespective of number of visit. (iv) Otherwise, periodicity shall be around 03 months or as per manufacturer instruction. (v) Replacement of minor items shall be included in the unit quoted rate. (vi) Replacement of any major defective items will not be included in the scope of work. However, the decision of Accepting Officer is final and binding in deciding, whether the defective item is major or minor in nature. (vii) Payment shall be made thrice for the period of 09 months proportionately.
Periodical servicing, calibaration and maintenance of Electric Air shower installed at TRCD/CRRW/75 RMU for smooth functioning of hudraulic doors, maintaining required air pressures, lighting etc all as directed.- 15 Nos
Note for Item No 121 :- (i) The unit quoted rate shall deem to be included to carried out all repairs noticed during the period. (ii) Repairs/ maintenance shall be carried out through the authorised service agency only as per instructions recommended by the original manufacturer. (iii) The authorised service agency must be attended as and when called for urgent nature of repair of synchronous panel irrespective of number of visit. (iv) Otherwise, periodicity shall be around 03 or as per manufacturer instruction. (v) Replacement of minor items shall be included in the unit quoted rate. (vi) Replacement of any major defective items will not be included in the scope of work. However, the decision of Accepting Officer is final and binding in deciding, whether the defective item is major or minor in nature. (vii) Payment shall be made thrice for the period of 09 months proportionately.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.
Note for item No 123: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
S&F in repairs on distribution board MCCB four pole, 125 Amp ultimate breaking capacity 25 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
S&F in repairs on distribution board MCCB three pole, 63 Amp ultimate breaking capacity 16 KA, 415V including connecting by using suitable size of lugs complete conforming to IEC -61439-1 complete all as specified and as directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 2.5 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one rum of 2.5 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.
Note for item No 127: (a) 2 runs of 2.5 sqmm cable along with one run of 2.5 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
Supply and Laying of XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 4 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, by taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately.
Supply and Laying of XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 6 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, by taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately.
Supply and Laying of XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, by taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately.
Supply and fix in repair Triple pole MCB 25 to 63 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Supply and fix in repair Triple pole Neutral MCB 16 to 32 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
Supply and fix in repair Triple pole Neutral MCB 40 to 100 Amp, 415 V, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 complete all as specified and as directed.
M&L for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one 15A Socket & switch point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 4 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly including taking down existing point wiring complete all as specified and as directed.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and as directed.
Note for item No 136: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor alongwith PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
LAKSHMI ELECTRICAL ENTERPRISES (BID ID -3170850)
Neptune Engineers and Builders (BID ID -3171189)
M/s.Sai Agency (BID ID -3169436)
PRIYA ENTERPRISES (BID ID -3167571)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .