Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 CrAccepted-AOC | ₹32.4 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹33.9 CrRejected-Finance CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹33.9 Cr | L2 | Rejected-Finance Being L2 |
| 3 | L3₹33.9 CrRejected-Finance EAST LANE GALI NO 01 ABROL NAGAR PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | ₹33.9 Cr | L3 | Rejected-Finance Being L3 |
| 4 | L4₹34.0 CrRejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹34.0 Cr | L4 | Rejected-Finance Being L4 |
| 5 | L5₹35.3 CrRejected-Finance | ₹35.3 Cr | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹15 L
Closing Date
20 Aug 2021, 6:00 pmClosed
CE AF Udhampur
CE AF Udhampur
CONSTRUCTION OF TECHNICAL ACCOMMODATION FOR GLADIATORS AT AF STATION PATHANKOT
2019_MES_265287_3
CEAFU-12/2019-20
Open Tender
Civil Works
793 days
Pathankot
As Per NIT and Tender Documents
10 documents required · 10 mandatory
₹3,000
GE AF Pathankot
₹15 L
Yes
22 Nov 2021
30 Mar 2021
21 Aug 2021
30 Mar 2021
20 Aug 2021
3 Aug 2021
31 Mar 2021 - 6 Apr 2021
Amount
BUILDING PART:-
SCHEDULE 'A' PART-I (SECTION-I) Design, supply, fabrication and erection of pre-engineered building (PEB) steel structure for portion mark " PEB STRUCTURE HANGAR" of size length 90 metre width 60 metre (Internal span) with clear hight of 12.9 metre including all civil works in RCC foundations duly designed, steel sliding motorised Hangar door system to be provided on front and rear of the hangar, including PQC flooring inside hangar before laying antistatic PU floor coating and the work listed in Sch 'A' notes and shown on drawings, design of PEB structure , provision of natural turbo ventilators to be design and instal in hangar with following specification and design criterias as finalise by the designer for size of hangar 90mX 60m (Internal clrear span) ceiling hight 12.90 M along with design for structural system for hangar door as per parameters for hangars and door as specified from approved firms as listed and vetting of design, drawing from IIT after acceptance of tender, the drgs / design shall be submitted by the contractor dully vetted by IIT within 45 days of acceptance of tender. Any delay if occures by the contractor , the contractor will be the responsble for the same and will will be dealt as per CA provission accordingly with the following:- (Cont to 1.02)
Note :- Rates quoted by the contractor shall also deem to include the cost of the following :- (i) Design of PEB structure Hangar portion along with structural system for hangar door with antifalling arrangement shall be design and provided for antifalling arrangement by the designer from PEB approved firm/vender as listed in particular specifications along with vetting of design/drawing from IIT . (ii) Design of RCC foundations. (iii) Arch drgs provided by the department will form part of contract however structural drawings for hangar provided by contractor, which will be vetted by IIT. (iv) The structural steel members shall be designed as specified here in before and in particular specifications. (v) The steel sliding motorised Hangar door system for Rear & front doors for the hangar, shall be designed as specified in particular specifications. (vi) The design for structural system for the Hangar door will also be vetted by the same organisation vetting the steel Hangar Design. (xix) Design of columns including rail for movement of double girder EOT crane of capacity 10 Ton along with vetting of design and drawings from IIT.
Total amount of Sch 'A' Part-I (Section-II) (Bldg work)
Total amount of Sch 'A' part-II (Internal water supply)
Total amount of Sch 'A' part-III ( Plumbing Work)
Total amount of Sch 'A' part-IV (Section-I) (Internal Electrification Works)
Total amount of Sch 'A' part-IV (Section-II) (Internal Electrification Works)Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
LED tube light fitting 1X18 watt, 230 volts industtrial batten type, powder coated with CRCA sheet body with bipin holders, connected block, one No LED tube rod with in build LED driver complete with all accessories internally pre-wired and including connecting up with three core flexible copper conductor of suitable size, complete all as specified and directed by Engr-in-Charge.
LED tube light fitting 2X18 watt, 230 volts industtrial batten type, powder coated with CRCA sheet body with bipin holders, connected block, two No LED tube rod with in build LED driver complete with all accessories internally pre-wired and including connecting up with three core flexible copper conductor of suitable size, complete all as specified and directed by Engr-in-Charge.
Lamp holder insulated body with back plate (ISI marked) for batten fittings including LED lamp of 10 Watt, complete all as specified and directed by Engr-in-Charge.
Surface mounted LED luminare for mirror lighting 10 watt Complete with lamp including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.50 sqmm, complete all as specified and directed by Engr-in-Charge.
LED Street light fitting 40 Watt , IP66 power coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass including street light bracket made out of 40mm dia GI pipe light grade 1.2 mtr long ,bent to shape, with all necessary fittings i.e nuts,bolts, clamps made out of flat iron 50X6mm -02 nos.complete all as specified and as directed by Engr-n-Charge.
Suspended type decorative integral high bay down lights 230 Volts 300 Watt LED anti perch pigeon spikes PVC for bird proofing of light, totally encosed type with inbuilt electronic driver with APFC, lower THD, open circuit protection, surge voltage protection up to 10 KV with built in SPD Confirming to IS 15885 Part-2/Sec 13, closed version with aluminum alloy pressure die casted housing, reftector tpughtened glass cover including fixing arrangment, complete all as specified and directed by Engineer-in- change.
Ceiling fan (as per BEE recommendation) 1200mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminium rotor complete with down rod, including fan regulator 5 steps two module flush in piano type, hanging of fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site or directed by engr-in-Charge
Heavy duty exhaust fan (as per BEE recommendation) 380mm sweep 900 RPM single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast alumn rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site or directed by Engr-in-Charge
Distribution board, triple pole & neutral 415 volts iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and netural link confirming complete with one MCCB 4 pole 415 volts 250 amps rating with rupturing cap 36 KA of the same make as of distribution board and including cuttting chases to wall for fixing DB and making good the distrubed wall surface complete all as required at site for AC in annex directed by Engineer-in-Charge.
Bus bar chambers fabricated out of sheet steel (CRCA) 2mm thick, indoor type, epoxy powder coated, sections made of ETP grade copper & dull tin plated, supported on suitable size insulators including 4 Nos copper bus bars of capacity 400 Amps with 1 No MCCB of capacity 250 Amps 4 Pole, 35 KA and with 2 Nos earthing points on both sides complete fixed flush in wall and making good to dusturbed surface matching with existing CPRI approved, complete all as specified and directed by Engr-in-charge
MCB single pole 240 Volts 6 to 32 amps with rupturing capacity 10 KA, "B" Curve type, complete all as specified.
MCB single pole 240 Volts 40 to 63 amps with rupturing capacity 10 KA, "B" Curve type, complete all as specified.
MCB single pole and neutral 240 Volts 35 to 63amps with rupturing capacity 10 KA "B" curve type, complete all as specified.
Rigid steel conduit stove enamelled black 40 mm dia welded, exclusive of junction and terminal boxes but inclusive of all fittings such as tees, bends, albows, reducers, bell mouth tube ends and all fixing accessories such as, lock nuts saddles pipe hook etc complete all as specified and directed by Engineer-in Charge.
Supply and laying PVC insulated electric power cables 1100 volts grade unarmoured with stranded coppeer conductor of size 70sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge.
LED Luminaire minium 35 Watt recess mounting suitable for fixing in false ceiling complete including electronic driver, surge protector, connector block, suitable for cutout of size 2 feet X 2 feet 240 volts, 50 Hz complete with all accesories all as specified and directed by Engineer-in-charge.
Exhaust fan single phase 230 volts, 250mm sweep in plastic body, including louvers with all connected accessories including making opening for fitting of exhust fan and making good to the distrubed surface as required, complete as specified and directed by Engineer-in-charge.
MCB Trilpe pole and neutral 415 votls 40 to 63 Amps with reputuring capacity 10 kA 'C' curve type complete all as specified and directed by Engineer-in Charge.
Supply and fixing wall mounting single phase air circulator fans in metallic bost 750 mm sweep with speed regulator, complete all as specified and directed by Engineer-in Charge.
Total amount of Sch 'A' part-V (ROAD, PATH AND CULVERT WORKS)
Total amount of Sch 'A' part-VI (RCC Drain and Cable works)
Total amount of Sch 'A' part-VII (Sewage Disposal Works)
Total amount of Sch 'A' part-VIII (Lightning Protection Work)
Total amount of Sch 'A' part-IX (Section-I) (External Water Supply Works)
Total amount of Sch 'A' part-IX (Section-II) (External Water Supply Works)Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Sluice valve, flanged of class 1.0 PN of size 80mm dia including nuts, bolts and rubber washer complete all as specified and directed by Engr in charge.
Cutting existing steel tubing for alterations or additions, Screwing existing steel tubing for alterations or additions screw on pipe to form connector done in position without taking down existing for 80 mm bore GI Pipe complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure, complete all as specified.
Material and labour for construction of valve pit including necessary excavation and earth work as required including necessary PCC work, brick work, plastering etc all as specified including fixing of MS sheet 6 mm thick cover and suitable size of angle iron frame with locking arrangement including two coats of red oxide arrangement including two coats of red oxide primer internal size of pit 600X600X600mm, complete all as specified and directed by Engr in charge.
Total amount of Sch 'A' part-X (Section-I) (Refregeration and Air Conditioning Works)
Total amount of Sch 'A' part-X (Section-II) (Refregeration and Air Conditioning Works)Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled wall mounted, copper wound with digital display indoor type for AC & designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 3 % and of capacity 5 KVA complete all as specified and directed by Engr-In-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled wall mounted, copper wound with digital display indoor type for AC & designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 3 % and of capacity 4 KVA complete all as specified and directed by Engr-In-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled wall mounted, copper wound with digital display indoor type for AC & designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 3 % and of capacity 2 KVA complete all as specified and directed by Engr-In-Charge.
Total amount of Sch 'A' part-XI (Section-I) (EXTERNAL ELECTRIFICATION WORKS)
Total amount of Sch 'A' part-XI (Section-II) (EXTERNAL ELECTRIFICATION WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supplying, installing, testing & commissioning of factory assembled silent Diesel Engine driven generating set 1500RPM of capacity 500 KVA, 3 phase, 4 wire,415 volt, 0.8 PF (MSL complete with control panel including integrated powder coated acoustic enclosure as per CPCB regulations and duly certified by agencies/labs designated by CPCB for noise and sound pollution level, etc floor mounted including PCC foundation as per manufacturer's instructions complete all as specified and directed and comprising of the following :- (A) DIESEL ENGINE required capacity for driving 500 KVA alternator multi cylinder, vertical type, 4 stroke, water cooled, electric start conforming to IS : 10001/10002/BS-5514 for continuous running capable of taking 10% overload for one hour in 12 hours complete and comprising of the following :- (i) Radiator cooling (ii) Radiator fan with guard (iii) Flywheel with starter ring (iv) Air cleaner oil bath type (v) Vacuum indicator (vi) Electronic governor class 1A (vii) Exhaust silencer (viii) Fuel filter & fuel hoses (ix) Fuel injection pump (FIP) (x) Fan & water pump assembly (xi) Lub oil filter & Pump (xii) Oil filter (xiii) Exhaust gas driven turbo charger (xiv) Lub oil cooler (xv) Engine maintenance manual with spare parts list (xvi) Suitably designed acoustic enclosure as per CPCB regulations. (xvii) Engine safety shut down system against low lub oil pressure and high water pressure (Cont to 15.02 to 15.04)
(xviii) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 2 X 12 volts 180 AH DC or as per manufacturers requirement including interconnecting cables/leads with terminals complete with starting/stopping switch, volt meter etc - 01 Set. (B) ENGINE INSTRUMENT PANEL digital type indicating the following (i) Starting switch on/off (ii) Water temp guage (iii) Hour meter cum RPM indicator (iv) Lub oil pressure (v) Lub oil temperature (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure (c) ALTERNATOR Shall be self excited, self regulated, brush less for 500 KVA continuous operation at the speed of 1500 RPM at 415 volts, 50Hz , three phase four wire system with advance electric voltage regulator to ensure high voltage accuracy with + 1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS- 13364 complete- 1 No. (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 type B1 foundation including adequate number of .suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No (NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor.
(E) Fuel tank fabricated out of 14 SWG MS sheet of capacity not less than 8 hrs continuous operation, inside canopy, with fuel level guage, drain plug, locking arrengements, etc with & including GI pipe connections duly laid as per engineering practice complete. (F) AMF CONTROL PANEL Supply, fabrication, fixing commissioning and testing, factory made, floor mounted, cubical automatic mains failure panel suitable for 500 KVA DG set, fabricated using 14 guage thick CRCA sheet, powder coated painting, suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming & outgoing leads/bus bas as approved with and including the following accessories as under:- (i) Master switch for auto/manual/reset/off- 01 No (ii) Ammeter digital type 96x96 mm to read 0 - 400 amps with CT's 1 set of 3, aux supply 230 volts, AC, accuracy class 1.0 (iii) Voltmeter digital type,96 x 96 mm to read 0 - 500 volts aux supply 230 volts, AC, accuracy class 1.0 (iv) Digital frequency meter -01 No. aux supply 230 volts, AC (v) Push button start, stop/ reset - 01 No (vi) Set of lamp for indicating load on , low pressure, high cylinder temperature, load on mains, set fails to start, low oil pressure
S&F Street light fitting LED type 72 Watt or higher side with pressure die casted aluminium housing with flat glass optical cover with lens to ensure uniform distribution with minimum 100 lumen/watt efficacy, IP 66 protection including sluge protection 5ka, LED Driver and housing of same make as of fitting as per BIS standards including connecting terminals, mounting clamp, mounting bracket if required and all other accessories reqd for fixing and making fitting operational complete as directed by Engineer-in-Charge.
Supply and fixing junction box outdoor type of size not less than 0.01 cum made of steel sheet 1.6 mm thick painted with two coat of synthetic enamel paint over a coat of red oxide primer having aluminium bus bar 4 Nos of capacity 100 amps mounted on porcelain/PVC insulator suitable for connection of minimum 2 nos LT cables of size 25/35 sqmm 3.5 core including clamps, nuts and bolts etc, 1 No MCB SP 6 Amps complete all as specified and directed by Engr-In-Charge.
Supply and fixing Aviation obstruction lights LED type with minimum 300 LEDs in aluminum housing and polycarbonate enclosure complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology or by mechanical means including making good to existing disturbed surfaces matching with existing complete all as specified and directed by Engr-In-Charge.
M & L for plateform for installation of transformer of mentioned size upto 1000 KVA as per manufacturers recommendations for each transformer, with brick construction in step on one side XPM jalli and fixed on angle iron post and gate openable type with locking arrangement earthwork in any type of soil incl plastering to bricks masonary work and painting to steel surface with two coat of synthetic enamel paint over a coat of primer and two coat of colour washing over a coat of white wash on plaster surface incl MS stand with locking arrangement for mounting transformer complete all as specified and directed. Note :- Confirming to TD Drg No. 1129 of Chief Engineer Udhampur Zone (Army)
PVC insulated, unarmound electric cable with copper conductor, single core, 1100 volts grade of size 400sqmm, laid in trenches, on wall/pole/floor or in air, passing through pipe/ducts/road/drain, jointing. testing and commissioning, complete all as specified and directed.
Total amount of Sch 'A' part-XII (Section-I) (Fire Fighting Works)
Total amount of Sch 'A' part-XII (Section-II) (Fire Fighting Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply installation testing and commissioning of repeater panel complying with BS EN 54 suitable for wall mounting confirming to IS-2189 fabricated out of 16 guage CRCA sheet incorporating audio visual indication including dry type maintenance free battery of suitable capicity and battery charger complete all as specified and directed by Engr-In-Charge. Make: Honeywell/Agni or equivalent as approved
Supply and fixing mannual operated monitor of long range suitable for pressure 7 bar, spray angle 120 degree, and vertical rotation 30 to 80 degree suitable for inlet connection with 100mm CI Pipe complete all as specified and directed by Engr-In-Charge.
Supply, fixing, installation, testing and commissioning of CPRI approved LT electric panel totally enclosed (factory, fabricated) indoor type double door powder coated inside and outside made out of CRCA sheet not less than 2.00mm thick with front and back opening having locking arrangment spray painting internally/externally including internal wiring with suitable size of copper strip bus bar chamber 3 phase and four wire type system 415 volts 50 Hz consisting of copper bus bar of capacity 400 amps confirming to IS 13947 (Part-I & Part-III) of 1993 and consisting of the following:- (i) MCCB 250 amps TPN-01 No (Incoming) (ii) MCCB 200 amps TPN-01 No (Outgoing for pump) (iii) MCCB 63 amps TPN-01 No (for jockey pump) (iv) AIuminium bus bar of 500 Amps rating -04 Nos (v) Phase indicator (vi) Including automatic starter for two numbers motors as per manufacturer recommendation. Note srl item no 17.01 to 17.03.:- Firefighting points and lightspoinnts in PEB hangar shall be as per CFEES guidlines shall be followed .
Total amount of Sch 'A' part-XIII (LAN Conduit Works)
Total amount of Sch 'A' part-XIV (EOT Crane Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Design, Supply, Installation, testing and commissioning of 10 Ton capacity EOT Crane double girder, The cross span width is 62m (1m each on gantry girder on either side ,electrically operated through pendant push button station floor operated type having hoisting height of 8 Mtrs approx, trolley with frame, crab buffers, gears with gear boxes shafts, rope drum, rope sheaves, wire rope, wheels, lifting hook, plate form on one side of the crane brackets, motors, limit switches, control panel pendant push button station, micro speed arrangements, wiring etc as per IS-3177, 807. All as specified below :- (a) Capacity 10.0 Tons (b) Cross span - 62 Metres (c) Long Span - 90 Metres (d) Hoist Lift 8 metres (e) Hoisting speed - 3 mpm and creep/micro speed 0.6 mpm (f) Hoisting motor of suitable HP as per design calculation submitted by OEM/Contractor (g) Cross travel speed - 10 mpm and creep/Micro speed of 2mpm (h) Cross travel motor of suitable HP as per design calculation submitted by OEM/Contractor (j) Long travel speed - 15 mpm and creep/Micro speed of 3 mpm (k) Long Travel motor, 1/2 Nos of suitable HP AS PER Design calculation submitted by contractor. (l) Operation pendant Push button from floor (m) Class of duty - II (Indoor ) (Cont to 19.02)
Supply and fix electrically operated EOT, portable I-Beam trolley gantry crane without cabin of capacity 0.4 Ton,Cross Travel - 03 Mtrs, lifting height 03 mtr from FFL, with duty class II as per IS-3177, 807, including pendant push button for indoor use without any auxiliary hoist, having speed of CT - 15 MPM and creep/Micro speed of 3.0 mpm, Hoist speed 3 mpm and creep/Micro speed 0.6 MPM complete all as specified and directed. Make :- Dinesh/Rockwell/CRANEX
Total amount of Sch 'A' part-XV (PQC Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Rolling and consolidation formation surfaces in cutting at OMC to achieve 98 percent of maximum of dry density (modified PROCTOR density) and to achive K-value of 5.30Kg/SqCm/Cm with 8 to 12 Tonne power roller including filling in soft spots, depression etc., which occur during rolling (for portion coming in cutting/original ground only) to required level and gradient including watering before and during rolling, complete all as specified and directed.
200mm thick Ganular sub Base(GSB) of grading II as per MORTH specification, surface formed, roller consolidated to required gradient and chamber, using earth compactor of 8 tonne to 15 tonne capacity or compaction at OMC to achieve 98 % density of max dry denisity (MDD) determined using modified proctor density determination method as per IS code to achieve min CBR 30 %, laid in layers of consolidated thickness all as specified and directed.
150mm consolidated thick Wet mix Macadam (WMM) in two layers of 75mm each with coarse aggregate of specified grade as per MORTH, spread, roller and consolidation to required gradient and camber using mechanical paver/grader and tandom vibratory roller/earth compactor of capacity 8 tonne to 15 tonne or compaction at OMC to achieve the min 98 % density of max dry denisity (MDD) determined using modified proctor density determination method as per IS code laid in layers of consolidation thickness all as specified and director.
150mm thick DLC (Dry lean concrete) with 7 days compressive strength of 10 N/sqmm with min cement content of 180 kg/cum or as per design mix whichever is more using grading as per MORTH specificion, spread rolled and consolidated to required camber and gradient using necessary mechanical sensor paver and tendom vibratory roller of capacity exceeding 8 ton and n exc 12 ton capacity complete all as specified and director.
350mm thick pavement quality concrete (PQC) work in pavement of flexural strength 45 kg/ sqcm (lower control limit) in field using minimum cement content as per Design mix but not less than 400 kg OPC cement per CUM with crushed graded stone aggregate, Combined grading of Coarse & fine Aggregate as per MORTH Table 600-3 and super plastisiizer, required as per design mix ( as per IRC V th revision ) mixed with triangular / non circular synthetic fiber reinforcement @ 0.25% by weight of cement, spread and compacted by using fixed form paver and all as specified and including necessary T & P for bull nosing , rounding of edges, and finishing the surfaces by mechanical brooming/ belting, curing etc complete all as specified shown on Drawings. Cured with curing compound as per recommendation of Auth approving design mix. Note : - Cost of admixture (super plasticizer) and curing compound are inclusive in the rate of above item. The synthetic fibre reinforcement shall be measured and paid separately under item no 20.09 of BOQ here-in-after.
Forming construction joint 25mm deep and 10 mm wide (using diamond cutter ) providing polythene backup rod 12mm dia sealed with polyurethane sealant ( min depth of sealant 12mm ) complying with BS 5212, BS 4254 and EN 41875-2003 priming the sides min MAF ±30% with ten years performance guarantee and applying masking tape on edge of joint prevent accident spillage of sealant on top surface to give net finish to sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawings specified and as directed.
Forming dummy joint 1/3depth of slab and 8mm wide (using diamond cutter ) providing backup rod 10mm dia and sealed with polyurethane sealant (min depth of sealant 12mm ) complying with BS 5212, BS 4254 and EN 41875-2003 priming the sides min MAF ±30% with ten years performance guarantee and applying masking tape on edge of joint prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawings specified and as directed.
Forming 25 mm wide expansion joint filled with compressible synthetic filler board for complete depth of joint 350mm i.e the thickness of slab, provision of closed cell backup rod 30mm dia , filled with polyurethane sealant (mm depth of sealant above back up rod shall be of 15mm ) complying with BS 5212, BS 4254 and EN 41875-2003 priming the sides min MAF ±30% with ten years performance guarantee and applying masking tape on edge of joint prevent accidental spillage of sealant on top surface to give neat finish to sealant and removing the masking tape after sealant is applied by mechanical means all as shown on drawings specified and as directed.
Supply only polyester non-circular virgin synthetic monofilament fibres reinforcement, cut length 12-18 mm , having minimum tensile strength 300 MPA , minimum melting temperature 250 degree centigrade and specific gravity 1.34 to 1.39 complete all as specified and as directed.
Polyethlene film 400 micron transparent/white spread and laid over sand layer with minimum 15 cm side and ends laps as per IS-2508. (Note : Net measurement shall be meqasured without any allowance of overlaps).
Total amount of Sch 'A' part-XVI (Working Station works)
Total amount of Sch 'A' part-XVII (Sec-I) (RO Plant works)
Total amount of Sch 'A' part-XVII (Section-II) (RO Plant works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply and fixing water purification system with 7 stages i.e Sediment filter, Pre-activated carbon filter cum adsorber, Carbon block filter cum adsorber, anti scalant cartridge, Reverse Osmosis (RO) Membrane, UV disinfection column , Post carbon commercial RO with taste enhancer of capacity 25 liters per hour, wall mounting, complete all as specified and directed by Engr-in-charge. Make :- Kent RO/Aquaguard/Livpure
Total amount of Sch 'A' part-XVIII (Signage and Marking Board Works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Double legged informatory sign board of any following size made out of 2mm thick aluminum sheet confirming to IS 736 to be covered with Hi intensity grade retro reflective film of shade as approved including boarder of 20mm thick as per IRC standard and letter of any type and colour ( size and colour as approved) to be fixed to sheet with suitable adhesive aluminum sheet fixed to structural street frame work made of MS square pipe 32mm dia heay duty fixed with nuts bolts/revets ensuring sagety against removal of plates MS tabular pipe frame fixed to two vertical posts made of 50mm size MS square pipe heavy duty (height from ground level to bottom of sheet is 2m to 4m as required as per site constraints) pipe should be cover with hi-intergrity graderetro reflective sheeting and al least 600mm in ground level for grip to sagety against over turning with cross of flat iron (FI 40 x 5) of 230mm long complete in all respect including two coats of synthetic enamel paint over a coat of red oxide primer and including excavation and earth work in any type of soil and ground in PCC 1:3:6 type C 1 (using 20 mm grade aggregated complete all as specified and director by Engineer-in-charge
All as per item No. 24.01 here-in-before but of size 1044mm X 800mm and leg length 600mm.
All as per item No. 24.01 here-in-before but of size 2836mm X 800mm and leg length 600mm.
All as per item No. 24.01 here-in-before but of size 2000mm X 800mm and leg length 600mm.
Total amount of Sch 'A' part-XIX (Site Clearance and earth works)
M M SHAWL Engineers and contractors pvt ltd
SRM BUILDERS AND ENGINERS PVT.LIMITTED
NSC Projects Pvt. Ltd.
SHIV CHARAN GUPTA AND SONS
Faith Builders
M/s Jatindra Construction Company
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
B D Raizada Projects Pvt Ltd
Shekhar Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid