Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.7 LAccepted-AOC C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-1 | Accepted-AOC Being L-1. | |
| 2 | L-2₹23.1 L+₹3.3 L (16.4%)Rejected-Finance RAWALPORA WANABAL PATI YAYIL POST OFFICE SANAT NAGAR SRINAGAR 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-2 | Rejected-Finance Being not L-1. | |
| 3 | L-3₹23.5 L+₹3.6 L (18.1%)Rejected-Finance 15 BAGHE ISLAM NEAR NH BY PASS BRIDGE LAL NAGAR CHANAPORA SRINAGAR JAMMU KASHMIR 190015 | SRINAGAR | JAMMU AND KASHMIR | 190015 | L-3 | Rejected-Finance Being not L-1. | |
| 4 | L-4₹25.0 L+₹5.1 L (25.8%)Rejected-Finance | L-4 | Rejected-Finance Being not L-1. |
Tender Value
₹26.3 L
EMD Value
₹52,620
Closing Date
21 Nov 2024, 6:00 pmClosed
GE 861 EWS
GE 861 EWS c/o 56 APO
PROVN OF ELECTRIC LT POLES ALONG SECURITY PERIMETER WALL WITH ALLIED WKS AT KHUNMOH GRN AND SPECIAL REPAIRS AND REPLACEMENT OF INTERNAL WIRING FITTINGS AND FIXTURES OF BUILDING NO T11 T16 T25 T29 AT SHER-E-SHALI GRN UNDER GE 861 EWS
2024_MES_680549_1
GE 861 EWS-65/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE 861 EWS
₹52,620
Yes
20 Dec 2024
21 Oct 2024
28 Nov 2024
21 Oct 2024
21 Nov 2024
7 Nov 2024
Amount
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation in any type of soil for poles/stay/cable etc including getting out in any type of soil complete all as specified and directed by Engr-in-Charge. Note: During Excavation repair damaged roads, walls etc will be repaired by contractor with PCC and payment will be made for it under relevant items of this schedule.
Excavation in trenches beyond 1.5 m wide and n.exc. 3 m deep for foundation hard/dense soil of poles/stay etc including getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soils complete all as specified and directed by Engr-in-Charge.
Removing excavated materials n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for river sand cushioning to cables with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness of 18CM shall be measured and paid.
M&L for Sub Class 'B' bricks for covering protection to the electric cables laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
Supply & fixing Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified type 410 SP -31 (9.00 meters long) including applying two coats of aluminium paint over a coat of red oxide primer and with white washing to concrete surfaces and numbering of poles etc complete all as specified and directed by Engr-in-Charge. Note:(a) Electric Poles shall be excuted at site alongwith perimeter fence, with manual excavation, Returning filling and Removal. (b) Location of poles will be based on user requirement and as directed by Engr-in-Charge.
Supply and fix LED flood/Street lights 60 W energy saving and environmental friendly light fitting IP 66 high power LED flood light with pressure die cast aluminium housing, suitable fittings at poles with nut & washer including suitable clamp, hinges etc. complete with all accessories, complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35Sqmm x 3.5 core, laid in duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of aluminium thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. During cable laying repair damaged roads, walls etc will be repaired by contractor with PCC and payment will be made for it under relevant items of this schedule all as directed.
Supply, laying and testing in replacement cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35Sqmm x 3.5 core, laid in duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of aluminium thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. During cable laying repair damaged roads, walls etc will be repaired by contractor with PCC and payment will be made for it under relevant items of this schedule all as directed.
Supply, laying and testing of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10sqmm 2 core, laid in duct / along pole/wall etc including making connection complete all as directed. Note : The cost of aluminium thimbles/lugs and cable gland etc is including in quoted rate and no extra payment will be made for it.
Supply and laying or fixing twin core or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated copper conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2.5 sq. mm nominal cross section 2 core as in service connections for street/security light connection with insulation tape complete all specified and directed by Engr-in-Charge.
S&F brackets made out of 40mm bore GI tubes medium grade, 1.5mtrs long for mounting one number Street/Perimtere security light fitting with and including bending 40 mm medium grade GI pipe at an angle of 30 degree, including clamps made out of 40mmx6mm MS Flat Iron/nuts/bolts & washers to brace the same properly including painting with two coats of synthetic enamel silver colour paint over a coat of red oxide zinc chrome primer complete all specified and directed by Engr-in-Charge.
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm centre to centre both way with suitable lifting handle and pit/chamber in PCC 1:3:6 type C1 , for pit cover including testing on completion complete all as specified and directed. Note:- After completion of work if desired test result are not obtained, the earthing is to be redone without any extra cost to deptt.
Supply & fix Rigid non-metallic PVC conduit of size 20 mm dia including all fixing accessories for pole/ wall , couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engr-in-Charge.
Supply fix and testing of on load change over switch 415V in sheet metal enclosures 4 pole of capacity 250 Amps, complete all as specified and directed by Engr-in-Charge.
M & L street light junction/pole box of size 300x250x180 mm or higed suitable size fabricated out of 2 mm thick MS sheet 4 nos aluminium bus bar strip 25x3 mm over protection insulators including suitable nut bolts and washers for fixing at pole/wall/CGI sheet etc, including magnetic/Nut bolt lock, gland for incoming and outgoing cable and one no MCB SP 6 Amp, complete all as specified and directed by Egr-in-charge.
Supply and fixing GI tube, 40 mm bore, light grade with all fittings/clamps of suitable size and nuts and bolts, including one coat of red oxide primer and painting two coats of synthetic enamel paint complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement GI tube, 40 mm bore, light grade with all fittings/clamps of suitable size and nuts and bolts, including one coat of red oxide primer and painting two coats of synthetic enamel paint complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed by Engr-in-Charge.
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having aluminium bus bar of capacity 200 amps for phases and 100 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, including taking down old panel complete mounted on PCC foundation, supporting channel, and outgoing with thimble/lugs, including the accessories as below complete and mounting the panel on ground/floor with PCC(1:3:6) bedding upto a height of 30 cm above ground level and 30 cm in foundation complete all as specified and directed by Engr-in-Charge. cable termination, cable gland etc, complete (Feeder Panel) including taking out old unsv panel, complete all as specified and comprising of the followings: (a) MCCB 100 Amps 4pole,36 KA (b) MCCB, 4 pole 63 Amps, 18KA, Thermal magnetic - 01 Nos (Out going) (c) MCB, SPN 32 Amps, 18KA, Thermal magnetic - 03 Nos (Out going) (d) Volt meter , digital type ,0 - 500V - 1 Nos (e) Ammeter, digital type with CT's - 1 No (f) indication lamps (R,Y,B) LED type - 1 set (g) Thermal magnetic - 1 No (Incomer) Note : The cost of thimbles/lugs and cable gland, PCC for panel base etc shall be measure and paid separately under respective item of this schedule
Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete including fittings such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc. complete all as specified and directed by Engr-in-Charge.
M & L for point wiring complete for light/ fan with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in PVC casing & capping and including pipe hooks , elbows, junction covers and junction boxes , after fixing or cutting on wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes 60mm deep, suitable length and thickness for mounting, switches, sockets, fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly fixed on wall or grouting and painted with red oxide metal primer and making good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly complete all as specified and directed by Engr-in-Charge.
All as per srl item No-25 here in above but for one 5A socket outlet on the same board controlled by one switch.
All as per srl item No-25 here in above but for one 3 pin 5A socket outlet independent controlled by one switch.
Description all as per srl item No 25 above but for 3 pin socket outlet 15 Amps independent board with 2.5 Sqmm wire.
M&L for submain wiring with two single core PVC insulated unsheathed , FRLS flexible copper conductor cable of size 6 sqmm and one single core PVC insulated unsheathed ,FR flexible copper conductor cable of size 4.0 sqmm as earth lead in & including PVC casing / non metallic rigid PVC conduit medium grade, and making good the disturbed portion complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engr - in - Charge.
S&F bell push flush type 6 Amps 240 Volt complete all as specified and directed by Engr-in-Charge.
S&F bell/buzzer AC 230 volts single pole complete all as specified and directed by Engr-in-Charge.
S&F for Switch Socket combination, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts complete all as specified and directed by Engr-in-Charge.
S&F for Switch Socket combination 2 in 1, 5 Amps flush type, 230 volts complete all as specified and directed by Engr-in-Charge.
S&F Socket 2 in 1, 5 Amps flush type, 230 volts complete all as specified and directed by Engr-in-Charge.
S&F fan regulator Electronic type complete all as specified and directed by Engr-in-Charge.
S&F ceiling rose surface bakelite three terminals complete all as specified and directed by Engr-in-Charge.
S&F energy saving exhaust fan 300 mm sweep sturdy engineering plastic complete with lovers shutters, voltage 230V, 50Hz, RPM 1200, copper winding making hole in wall wherever required and, connecting electrically to ceiling rose or connector block using PVC insulated and overall sheathed 3 core cable of size 0.75 Sqmm with flexible copper conductor all as required at site and taking down old unserviceable exhaust fan from building and depositing to MES store yard complete all as specified and directed by Engr-in-Charge
S&F ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with squirrel cage induction motor where required and connecting electrically to ceiling rose or connector block using PVC insulated and overall sheathed 3 core cables of size 0.75sqmm with flexible copper conductor all as required at site and taking down old unserviceable ceiling fans from building and depositing to MES store yard complete all as specified and directed by Engr-in-Charge.
Supply and fix in electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection pipe ( PVC connection of 15 mm bore with PTMT nut of length 450 mm suitable for hot water and cold water for geysers ) including fixing arrangement like clamps , nuts, bolts washers, suitable type of fastner and making good the disturbed surfaces as per existing etc and taking down old unserviceable electric water heater from building and depositing to MES store yard complete all as specified and directed by Engr-in-Charge.
Supply and fixing sheet metal enclosure with socket plug top single phase and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 amps, B curve complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB 32 to 40 Amps SP 240 volts, 10 kA ' B curve complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED lights fitting 1x22W, 230V, AC decorative box type with drive, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fixing round/square shape 15 watt ( white/Warm white) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable bldg Security light fitting and taken as credit including supply & Fix 25W New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaries with high power LED as light source along with suitable bracket including all accessories complete all as specified and directed by Engr-in-Charge.
S&F Lamp holder insulated body with back plate for batten fittings complete all as specified and directed by Engr-in-Charge.
Supply and fixing of LED 9 watt pin type bulb complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 1x5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fixing Decorative wall light fixture made up of Polycarbonate, suitable for 9 W retrofit LED lamp B22 base including 9 watt LED lamp with necessary connection of suitable twisted copper flexible wire complete all as specified and directed by Engr-in-Charge. Make : Havells cat Part No-LHDL02160099 or equivalent in Philips/ Bajaj
S&F MCCB Distribution board, TP&N , vertical , double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link,415 Volts 4 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 3 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory all as specified and directed. Make: Indoasian Cat part No KSLTVM04 or equivalent in Legrand/ Havells.
Supply and fix MCB Distribution board, 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed by Engr-in-Charge. Make: Indoasian Cat part No:- KSLT0008 or equivalent in Legrand/ Havell's/ ABB
Supply and fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB) of current carrying SPN 40-63 Amps capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amps in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Material & labour for earthing complete in replacement with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm centre to centre both way with suitable lifting handle and pit/chamber in PCC 1:3:6 type C1 , for pit cover including testing on completion complete all as specified and directed. Note:- After completion of work if desired test result are not obtained, the earthing is to be redone without any extra cost to deptt.
Material & labour for earthing complete in replacement with galvanised cast iron earth plate electrode of size 600x600x6.0mm thick busied directly in ground less than 2.25mtr deep below normal ground level as earth electrode with top edge of the earth plate not less than 1.50mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shora all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. (i) Main earthing lead from earth plate electrode to test point up to length of 7.5 meters length shall be deemed to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 meter shall be measured and paid for separately under appropriate item of Sch A. (iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department .
FIRDOUS AHMAD BABA (BID ID -3165634)
M/S Manzoor and Co (BID ID -3165491)
CHINAR CONSTRUCTION TRADERS (BID ID -3171101)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .