Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹39.1 L+₹1.6 L (4.26%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹39.4 L+₹1.9 L (5.08%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | MAMTA ENTERPRISES L3 | Nitika electricals and engineers works L2 | M/S KALSI ENGINEERS AND CONTRACTORS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone masonry, built in CM including all quoins, arches, pillars etc. but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed. | 9.57 | Cum | 50 ₹478.5 Lowest | 200 ₹1,914 | 50 ₹478.5 Lowest |
| 2.00 | M & L for Brick work with sub class B (old size) brick straight or curved on plan exc 6 m mean radius in CM 1:4 complete all as specified and directed. | 9.57 | Cum | 4,000 ₹38,280 Lowest | 4,000 ₹38,280 Lowest | 4,000 ₹38,280 Lowest |
| 3.00 | All as item no 2 above but except bricks complete all as specified and directed. | 1.5 | Cum | 2,200 ₹3,300 | 2,000 ₹3,000 | 1,200 ₹1,800 Lowest |
| 4.00 | M & L for Dewatering/Desludging & cleaning of manhole of any depth, any size, taking out water mixed with sludge and solid sludge including any foreign materials such as stones, tree hedges etc, removing and depositing sludge at a distance not less than 20 meter in a ditch including necessary excavation of pits and covering with earth & spraying unslaked lime on the covered ditch as well as around the manholes to make hygienic including necessary flushing of manholes with water after desludging complete all as specified and directed. | 400 | Each | 100 ₹40,000 Lowest | 220 ₹88,000 | 500 ₹2,00,000 |
| 5.00 | Taking out/Pumping out contaminated sewage water from septic tank/soakage well including inlet/outlet chamber after plugging incoming sewage line through combined high pressure water jetting cum suction (vaccum) type machine mounted on HCV Honey succer vehicle of capacity not less than 6000 ltrs each and facility of high pressure vaccum and removing off the same in the pit to a placet all as directed by Engineer-n-Charge. Note;One lorry unit will be considered for full load of 6000ltrs irrespective of taking out. complete all as specified and directed. | 100 | Per Lorry | 1,600 ₹1,60,000 | 1,000 ₹1,00,000 Lowest | 1,000 ₹1,00,000 Lowest |
| 6.00 | M & L for Desludging the solid sludge from septic tank, soakage well including inlet/outlet chamber, removing out all scum, silt reduce sludge (both organic/inorganic nature) after plugging the incoming sewage line through combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV and facility of high pressure vacuum and removing and dumping off the same in the tank to a place out side cantonment at the place marked for the purpose by local municipality or area controlling authority complete all as specified and directed. | 85 | Cum | 120 ₹10,200 Lowest | 220 ₹18,700 | 300 ₹25,500 |
| 7.00 | M & L for Cleaning of soil waste pipe (cast iron/PVC/SGSW/DWCP )150/200mm bore laid in ground any slope or gradient and depth 3 mtr by roding taking out all residue from the lines/manholes including water and depositing at a distance not less than 20 mtr in ditch finally covering the ditch with earth and spraying unslacked lime on the covered ditch as well as around the manholes to make hygienic including excavation of ditch testing of line by flushing water after cleaning etc complete all as specified and directed. | 500 | RM | 30 ₹15,000 | 22 ₹11,000 Lowest | 40 ₹20,000 |
| 8.00 | M & L for Cleaning/clearing of IWC/ EWC, gully trap /floor trap including CI pipe / PVC pipe upto first manhole by roding, taking out all residue including waste and testing by pouring water after cleaning etc complete all as specified and directed by Engr-in-Charge. (Note: Cleaning of PVC/CI pipe from first floor / ground floor embedded in floor or fixed to wall included in this item) complete all as specified and directed. | 200 | Each | 40 ₹8,000 | 50 ₹10,000 | 20 ₹4,000 Lowest |
| 9.00 | M & L for Cast iron oval access covers / inspection cover with bolts rubber gasket to make it water tight for 75mm/100mm bore CI fittings including taking out broken/ unserviceable cover with bolts etc and removing from site complete all as specified and directed. | 9 | Each | 100 ₹900 | 250 ₹2,250 | 50 ₹450 Lowest |
| 10.00 | Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m wide for foundation etc or for shaft, wells, cesspits, manhole, pair house etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth and getting out in any type of soil complete all as specified and directed. | 240 | Cum | 130 ₹31,200 | 100 ₹24,000 | 70 ₹16,800 Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
6 Aug 2025, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR REPLACEMENT OF SEWAGE LINE CLEANING OF MANHOLES SEPTIC TANKS ETC INCL DAY TO DAY LINE CLEANING AND REPAIRS TO BOUNDARY WALL AND MAINT OF EXTERNAL PIPE LINE SLUICE VALVE ETC AND MAINT OF PERIMETER SECURITY LIGHTS AT 213 TC UNDER GE NAGROTA
2025_MES_719429_1
CANO GEN-63/2025-2026
Open Tender
Civil Works
Item Rate
180 days
GE NAGROTA
Class D Cat a(ii)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹1 L
Yes
9 Oct 2025
9 Jul 2025
13 Aug 2025
9 Jul 2025
6 Aug 2025
23 Jul 2025
Amount
Demolition of brick work or stone masonry, built in CM including all quoins, arches, pillars etc. but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed.
M & L for Brick work with sub class B (old size) brick straight or curved on plan exc 6 m mean radius in CM 1:4 complete all as specified and directed.
All as item no 2 above but except bricks complete all as specified and directed.
M & L for Dewatering/Desludging & cleaning of manhole of any depth, any size, taking out water mixed with sludge and solid sludge including any foreign materials such as stones, tree hedges etc, removing and depositing sludge at a distance not less than 20 meter in a ditch including necessary excavation of pits and covering with earth & spraying unslaked lime on the covered ditch as well as around the manholes to make hygienic including necessary flushing of manholes with water after desludging complete all as specified and directed.
Taking out/Pumping out contaminated sewage water from septic tank/soakage well including inlet/outlet chamber after plugging incoming sewage line through combined high pressure water jetting cum suction (vaccum) type machine mounted on HCV Honey succer vehicle of capacity not less than 6000 ltrs each and facility of high pressure vaccum and removing off the same in the pit to a placet all as directed by Engineer-n-Charge. Note;One lorry unit will be considered for full load of 6000ltrs irrespective of taking out. complete all as specified and directed.
M & L for Desludging the solid sludge from septic tank, soakage well including inlet/outlet chamber, removing out all scum, silt reduce sludge (both organic/inorganic nature) after plugging the incoming sewage line through combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV and facility of high pressure vacuum and removing and dumping off the same in the tank to a place out side cantonment at the place marked for the purpose by local municipality or area controlling authority complete all as specified and directed.
M & L for Cleaning of soil waste pipe (cast iron/PVC/SGSW/DWCP )150/200mm bore laid in ground any slope or gradient and depth 3 mtr by roding taking out all residue from the lines/manholes including water and depositing at a distance not less than 20 mtr in ditch finally covering the ditch with earth and spraying unslacked lime on the covered ditch as well as around the manholes to make hygienic including excavation of ditch testing of line by flushing water after cleaning etc complete all as specified and directed.
M & L for Cleaning/clearing of IWC/ EWC, gully trap /floor trap including CI pipe / PVC pipe upto first manhole by roding, taking out all residue including waste and testing by pouring water after cleaning etc complete all as specified and directed by Engr-in-Charge. (Note: Cleaning of PVC/CI pipe from first floor / ground floor embedded in floor or fixed to wall included in this item) complete all as specified and directed.
M & L for Cast iron oval access covers / inspection cover with bolts rubber gasket to make it water tight for 75mm/100mm bore CI fittings including taking out broken/ unserviceable cover with bolts etc and removing from site complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m wide for foundation etc or for shaft, wells, cesspits, manhole, pair house etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth and getting out in any type of soil complete all as specified and directed.
Returning filling in including, spreading, leveling watering and well ramming in layer not exceeding 25cm in each layer complete all as specified and directed.
Removing excavated material not exceeding 50 M and depositing where directed at level not exceeding 1.5m above the starting pointing complete all as specified and directed.
M & L for Plain cement concrete 1:4:8 as in foundation type D-2 (using 40mm graded crushed stone aggregate) as in fdn filling or mass concrete complete all as specified and directed.
M & L for Plain cement concrete 1:2:4 type B-1( using 20mm graded aggregate) as in benching, coping including watering slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M & L for TMT mild steel bars 10MM dia and over cut to length bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire annealed 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for Mild Steel TMT bars 6 to 8 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
M & L for RCC 1:1.5:3 type B-1 (using 20mm graded crushed stone aggregate) as in slab cover for septic tanks including fomwork complete all as specified and directed.
M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and directed.
M & L for Precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in manhole/drain slab cover and set in CM 1:4 including fomwork complete all as specified and directed.
M & L for Rendering 15mm thick cement plaster in CM 1:4 on faces of brick work with or concrete WPC finished even and smooth without using extra cement all as specified ( WPC shall be measured and paid separately. ) complete all as specified and directed.
Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar complete all as specified and directed.
Demolition and breaking up 200 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar complete all as specified and directed.
M & L for Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 150mm bore pipe, complete all as specified and directed.
M & L for Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 200mm bore pipe, complete all as specified and directed.
M & L for Salt -Glazed stoneware drain pipes 150 mm dia laind in trenches and jointed complete all as specified and directed.
M&L for 200mm bore dia reinforced cement concrete pipes, class NP-2, laid and jointed complete with collars, complete all as specified and directed.
M & L for 200mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed
M & L for 150mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed
M & L for Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified and directed.
M & L for Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 225mm dia of pipe complete all as specified and directed.
M & L 75mm thick PCC 1:3:6 Type B2 ( 40 mm graded aggregsate) as in subbase, Hardstanding and pavings etc complete all as specified and directed.
M & L for Glazed ceramic colored tiles 600mmx300mmx 6 to 7mm thick/450mm x300 mm x 7mm,as in patches in vertical surfaces such as dado, skirting, wall etc set & jointed in neat cement slurry and pointed with coloured cement to match with tiles in over and including 10mm thick cement plaster in cement mortar 1:4. complete all as specified and directed.
S&F Non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.11sqm but n exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or beddding layer of CM 1:6 including complete all as spd and directed.
M & L for 100mm dia Cast iron pipes with flanged ends, centrifu?gally cast, class A, in any length laid in trenches complete all as specified and directed.
M & L for 80mm dia Cast iron pipes with flanged ends, centrifu?gally cast, class A, in any length laid in trenches complete all as specified and directed.
M & L for upto 150mm bore Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore. complete all as specified and directed.
S&F PVC (SWR) Branch Piece double equal or unequal of 110mm bore complete all as specified and directed..
S&F PVC (SWR) Branch Piece double equal or unequal of 75 mm bore complete all as specified and directed..
S&F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incl bolt and nuts securing ends of stays to wall or roof of 75mm bore complete all as specified and directed..
S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
M & L for cleaning of all types of blockage of Nahni traps/floor traps/bottle traps, blockages of WC's, rain water pipes and similar works complete all as specified and directed by Engr-in-Charge. Note :- 1. Labour shall be provided by the contractor on daily basis from 9:00 AM to 5:00 PM incl all Tools and Plants. Each labour shall intertain complaints everyday in working hours. 2. The supervisor of Contactor shall take all complaints from the Complaint Cell and do the all on same day. 3. Futhermore, the feedback shall be given by the contractor/supervisor to concened JE from all aspect.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from cement concrete and making good disturbed ground complete all as specifed
Excavation for post holes in any type of soil (or in similar hole ) each n.exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm including dismantling PCC including disposal of surplus n.exc 50m all as specifed and directed by Engineer -in- Charge.
M&L for PCC 1:3:6 type C-2 (40mm graded aggts) in foundation filling and mass concrete complete all as specified and directed.
M&L for posts and struts in fencing of angle, tee including cutting tops to shape as directed, drilling holes, notching for wire, Y angles wall for fencing, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed etc complete all as specified and directed.
M & L for Fixing chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed.
Supply only Chain link fencing with or without line wires,any type and mesh size and any type of standards and dia of wire ( as directed by Engineer-in-charge) fixed with rails, staining bolts etc including provision of binding wire including dismantling existing unserviceable fencing all as specifed and directed.( rails, staining bolts will be measured in seperate Item)
M & L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and 5 to 10mm dia of shank complete all as specified and directed
M & L for Preparation new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by Engr-in-charge
Dismantling of barbed wire fencing of any description and any positions complete all as specified and as directed.
Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion. complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n.exc 15cm thickness (below & above GL) unreinforced complete all as specified and directed.
S&F Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as complete all as specified & directed.
M & L for Fixing only galvanised 2 strand, steel barbed wire of any description (obtained from dismantling) and straining and fixing to any type of standard rails straining bolts, including aluminium paint and securing or tying at crossing with and provn of galvanised MS wire complete all as specified and as directed.
M & L for Fixing,Restraining,resecuring incl making good staples etc of existing barbed wire fencing complete all as specified and directed.
M&L Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia 10 metre openable length , having 50 Nos rounds per 6 metre length, spring core wire (2.5 mm thick) of high tensile strength of 165 Kg/Sqmm with tape (0.52mm thick) and weight 43.478 gm/ metre and fixing the same with existing Y-shape dangle iron placed 2 mapartand with 6 horizontal R.B.T (Reinforced Barbed Tape) wire, stud tied with G.I staple and GI clips to retain horizontal, incld necessary bolts, complete all as specified and directed.
M & L for Preparation of old decorated plastered or unplastered surface including cleaning by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasy spots and applying one coat of cement base paint on walls of external surfaces complete all as specified and directed..
All as per itme no 58 above here-in-before but applying two coat of cement base paint on walls of external surfaces complete all as specified and directed..
M&L for providing precast cement concrete (type B0 1:2:4 12.5mm graded aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings and form work including demlation of old louvres and jallies complete all as specified and directed.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded as in sub base of floor, hard standing (40 mm graded stone aggregate), finishing even and smooth without using extra cement to received tiles including necessary form work etc complete all as specified and directed.
M&L in repair 60mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and laid over and including 25mm thick grid cushion complete all as specified and directed.
Supply & Laying in trenches galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site for the following sizes including dismantling and taking out old unserviceable pipe line alongwith fittings from existing connections:- Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe.
Bore of tube 150 mm dia.
Bore of tube 100 mm dia.
Bore of tube 80 mm dia.
Bore of tube 50 mm dia.
Bore of tube 40mm dia.
Bore of tube 25mm dia.
Bore of tube 20mm dia.
Bore of tube 15mm dia.
Supply & Fixing galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors including dismantling existing steel tubing and connections fixed at any location all as directed for the following sizes:- Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe.
Bore of tube 40mm dia.
Bore of tube 25mm dia.
Bore of tube 20mm dia.
Bore of tube 15mm dia.
S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location complete all as specified and directed for the following sizes:-
50 mm dia.
40 mm dia.
25 mm dia.
20 mm dia.
S&F stop valves of cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipe or for unions and fixed complete all as specified and directed to the following sizes:-
Bore dia of pipe 25mm.
Bore dia of pipe 20mm.
Bore dia of pipe 15mm.
Supply and fix cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts including dismantling of old unserviceable sluice valve fixed at any location complete all as specified and directed for the following sizes:-
150mm dia.
100mm dia.
80mm dia.
Material & Labour for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 100 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable non return valve complete all as specified and directed
Material & Labour for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 150 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable non return valve complete all as specified and directed
M & L for Construction of valve chambers with 150 mm thick PCCfoundation 1:4:8 type D2 using 40 mm graded trap stone aggregate, 230 mm thick brick masonary wall with sub class 'B' bricks builts in cement mortar 1:4 10 mm thick plastering to brick masonary in cement mortar internally and externally upto 15 cm below ground level, 50 mm thick coping with PCC 1:2:4 type B1 using 20 mm graded crushed trap stone aggregate valve chamber frame cover made of mild steel angles of size 40mm x 40mm x 6mm and cover made of 2.5 mm thick mild steel sheet fixed with mild steel hinges - 02 Nos, locking arrangements with provision of locks and painting the steel surfaces with two coats of synthetic enameled paint over a coat of zinc chromate primer including neccessary earth work, excavation, dismantling of existing valve chmber of any size and pattern and at any position complete all as specified and directed for the following:-
1000CM x 1000CM X 1000CM (Internal Size)
900CM x 900CM X 900CM (Internal Size)
M & L for Servicing , painting and greasing & minor repairs of sluice valves of different sizes at any location including replacement of glands complete all as specified and directed
M & L for Attending emergency breakdown/ complaint of damaged water supply GI/ CI/ DI pipe lines in distribution system and main rising system of size 15 mm to 150 mm and restoring the water supply by stopping the leakage occured by deputing skilled/ semiskilled man power for smooth functioning of water supply complete, including excavation, returning filling in, ramming, & removing the soil to a distance n. exc. 50 m, cutting & threading all as directed by the EIC or as required at site. Note:-(i)The CI specials and lead joints shall be measured and paid separately (ii) The cost of necessary earth work and repair to damaged road shall deemed to be included in the quoted rates by the contractor and no extra payment shall paid on this account. (iii)The cost of JCB ( min. of 8 hours work ) for Attending complain shall deemed to be included in the quoted rates by the contractor and no extra payment shall paid on this account.
Supply and fixing the following item to be incorporated against item No. 73 complete all as specified and directed
GI union of 40mm & 50mm dia.
GI union of 15mm to 25mm dia.
GI nipple of 40 mm & 50mm dia.
GI nipple of 15mm to 25mm dia.
GI sockets/elbow of 40mm & 50mm dia.
GI socket/elbow of 15mm to 25mm dia.
Run lead joints for 150 mm cast iron pipe including spun yarn complete.
Run lead joints for 100 mm cast iron pipe including spun yarn complete all as specified and directed
Run lead joints for 80 mm cast iron pipe including spun yarn complete all as specified and directed
Flanged Joint with rubber or fiber board gasket for 80 mm GI/CI/DI pipe including complete accessories.
Flanged Joint with rubber or fiber board gasket for 100 mm GI/CI/DI pipe including complete accessories.
Flanged Joint with rubber or fiber board gasket for 150 mm GI/CI/DI pipe including complete accessories.
Titan joints for 80 mm cast iron pipe including complete acessories..
Titan joints for 100 mm cast iron pipe including complete acessories.
Titan joints for 150 mm cast iron pipe including complete acessories.
Mechanical joints for 150 mm CI/DI pipe including complete accessories.
Mechanical joints for 100 mm CI/DI pipe including complete accessories.
Mechanical joints for 80 mm CI/DI pipe including complete accessories.
M & L for Cast iron fittings for spigot and socket / flanged pipe upto 150 mm bore such as bends (any type radius and angle) tapers any type (straight, bends) tee, joint piece single branch Y junctiondouble branch cross (all socket or socket and spigot or all flanged ends) coller caps and plug, connecting piece one end flanged and other socketed or spigot and bell mouth complete all as specified, The fitting shall be as per IS 1538-1989.complete all as specified and directed
Supply and fix repair column pipe for borewell made out of mild steel (MS) 100 mm bore 3 mtr length each welded with MS flanged drilled for nut bolts & washer including rubber gasket. (T&P) as required will be provided by the contractor complete all as specified and directed.
Supply and fix repair column pipe for Over Head Tank made out of mild steel (MS) 150 mm bore 6 mtr length each welded with MS flanged drilled for nut bolts & washer and rubber gasket including painting with two coat of synthetic enamel paint over a coat of red oxide primer, . (T&P) as required will be provided by the contractor complete all as specified and directed.
M & L for Attending emergency breakdown of water supply installation where directed. lifting defective submersible pumpset, column pipes (any number) from borewell, setting aside and stacking column pipes for reuse, transportation the pumpset to MES store yard for checking of repair work, transportation of serviceable pumpset from MES store yard to bore well, lowering of submersible pumpset with column pippes in the borewell as existing with new nut, bolts and washer including rubber gasket 3 mm thickand making water and electrical connections as existing for running of pump motors complete all as directed. The pumping set after repair shall be lowered as per the manufacture specification. Note:- (i) T&P required for lifting and lowering for submersible pump set column pipe (any number) shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor.
M & L for Repairs to submersible pumpset coupled with motor of capacity 25 to 45 HP 3 Phase, 415 volts onvolving the following operations and rates are included for the following functions and replacement of UNSV parts. (a) Opening of the defective Pump from motor at site, cleaning the covers and parts as applicable in presence of Engineer-in-Charge to ascertain the quantam of defects and repairs involved. (b) Transporting the defective Pump to contractors workshop for repairs as decided by Engr-In-Charge and carrying out the needful repairs.(c) Assembling the Pump with motor after repair.(d) Spray painting the repaired Pump externally with two coats of synthetic enamelled paint of shade as directed by Engr-in-Charge. (e) Transporting the repaired Pump to site, Assembling the Pump with motor and carrying out necessary test in presence of Engineer-in-Charge to establish the functionability of the repaired Pump upto the entire satisfaction of the Engineer-in-Charge. (f) Replacement of unserviceable part of pump like Thrust Bearing, bearing cover sleeve, intermediate shaft, stud ring, neck ring, stainless steel key/sleeve for immpeller shaft, shaft coupler, body bush thrust pad & repair/ Replacement of impeller etc of Pump.
M & L for Repairs/rewinding to submersible motor of Cap 25 HP,3 Phase, 415 volts dismanteled from submersible pump set complete as per existing gauge/size/turns super enemalled copper winding wire complete all as specified and directed
M & L for Repairs/rewinding to submersible motor of Cap 45 HP,3 Phase, 415 volts dismanteled from submersible pump set complete as per existing gauge/size/turns super enemalled copper winding wire complete all as per directed by Enginner in Charge at site.
Material & Labour for CI non return butterfly valve, ISI marked with GM flap of size 150 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable valve complete all as specified and directed
Material & Labour for CI non return butterfly valve, ISI marked with GM flap of size 100 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable valve complete all as specified and directed
Material & Labour for CI non return butterfly valve, ISI marked with GM flap of size 80 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable valve complete all as specified and directed
Material & Labour for CI non return butterfly valve, ISI marked with GM flap of size 50 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable valve complete all as specified and directed
Supply and fixing as in replacement of 'V' fan belt size C1500 C-57 for blower compressure (evaporator Motor) as per existing and complete all as specified and directed
M & L for Servicing / maintenaace of Air Blowers coupled with electric driven AC induction Motor of cap 10 HP three phase including carrying out maintenace check along with following repairs (a) Dismantling of Twin lobe commpressor in presence of MES representative and display all the parts without damage any portion for inspection of Engr in Charge to ascertain the serviceability of existing parts and assembling the same after filling compressor oil No 320 or as existing, upto indicated level. (b)Heating, varnishing to stator, rotor with super qualityvarnish and drying out properly. (c) Cleaning, washing and greasing of ball bearing complete. (d) Assembling of motor with old serviceable parts and replacement of UNSV parts with new as ordered where necessary. (e) Installation of motor by making connections as per existing and testing on load complete. Note:- Any minor repair and replacement of parts like bearing,gasket, gland packing, Nuts bolts washers, Gear oil of compressor etc and labour cost to be included in the quoted rates. (ii) Rewinding of motor if required shall be measured and paid separately under appropriate item of Sch
Servicing Maintenance of centrifugal pump set of sewage water discharge coupled with electrical motor AC of capacity 7.5 HP, three phase, carrying out maintenance check along with following repairs :- (a) Dismantling of centrifugal pump set in presence of MES representative and display all the parts without damage any portion for inspection of Engr in Charge to ascertain the serviceability of existing parts. (b) Heating, varnishing to stator, rotor with super qualityvarnish and drying out properly. (c) Cleaning, washing and greasing of ball bearing complete. (d) Checking play of impeller and bushing of pupm and repair/replacement of bushes, gland, sleeves etc. (e) Assembling of motor and pump with old serviceable parts and replacement of UNSV parts with new as ordered where necessary. (f) Installation of motor by making connections as per existing and testing on load complete. Note:- Any minor repair and replacement of parts like bearing,gasket, gland packing, Nuts bolts washers etc and labour cost to be included in the quoted rates. (ii) Rewinding of motor if required shall be measured and paid separately under appropriate item of Sch
M & L for Servicing Maintenance of centrifugal pump set of sewage treated water discharge coupled with electrical motor AC of capacity upto 5 HP, three phase, carrying out maintenance check along with following repairs :- (a) Dismantling of centrifugal pump set in presence of MES representative and display all the parts without damage any portion for inspection of Engr in Charge to ascertain the serviceability of existing parts. (b) Heating, varnishing to stator, rotor with super qualityvarnish and drying out properly. (c) Cleaning, washing and greasing of ball bearing complete. (d) Checking play of impeller and bushing of pupm and repair/replacement of bushes, gland, sleeves etc. (e) Assembling of motor and pump with old serviceable parts and replacement of UNSV parts with new as ordered where necessary. (f) Installation of motor by making connections as per existing and testing on load complete. Note:- Any minor repair and replacement of parts like bearing,gasket, gland packing, Nuts bolts washers etc and labour cost to be included in the quoted rates. (ii) Rewinding of motor if required shall be measured and paid separately under appropriate item of Sch
M & L for Rewinding of AC induction motor 10 HP Three phase dismanteled from Blowers complete as per existing gauge/size/turns super enemalled copper winding wire complete all as specified and directed
M & L for Rewinding of AC induction motor 7.5 HP Three phase dismanteled from sewage water discharge centrifugal pump set complete, as per existing gauge/size/turns super enemalled copper winding wire complete all as specified and directed
M & L for Rewinding of AC induction motor upto 5 HP Three phase dismanteled from treated water discharged centrifugal pump set complete as per existing gauge/size/turns super enemalled copper winding wire complete all as specified and directed
Material & labour for applying one coat of synthetic enamel paint to all GI/CI pipe, Sewage/Blower Pump motors surfaces of any size inside/out side of Sewage Treatment plant complete with existing colour and marking arrows and all points as existing complete all as specified and directed
Supply & Fix automatic star delta starter in sheet enclosure type (Motor rating 7.5 HP ) suitable for 3 phase,415V,50HZ pump set upto 7.5HP suitable for fixed in the existing electric panel including taking down existing defective star delta starter complete all as specified and directed.
Supply & Fix in replacement of unserviceable star type rubber coupling suitable size for centrifugal pump set upto 10 HP complete as per sample complete all as specified and directed.
Supply & Fix in replacement of unserviceable MS coupling suitable size for coupled to induction motor with centrifugal pump set upto 10 HP complete all as specified and directed
Supply & Laying in trenches Black Berlia HDPE (High density polyethylene) pipe of size 63 mm dia with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site for the following sizes including dismantling and taking out old unserviceable pipe line alongwith fittings from existing connections:- Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe.
M & L for Disconnecting and removing to workshop opening for repair automatic voltage stabilizer for automatic operation air cooled servo controlled type input voltage 260-440V and output voltage 420 V cap 50 KVA to 160 KVA complete all as specified and as specified and as directed Note : Replacement of the parts if any found worn out/defective shall be measured and paid for separately.
M & L for Dismantling and rewinding of dimmer coil with super enameled copper winding wire incl varnishing tapping and insulating material to get same capacity of 50 KVA to 160 KVA complete all as specified and directed
M & L for Replacement of electronic circuit plate complete with DC transformers (PCB cold) complete capacity of 50 KVA to 160 KVA complete all as specified and directed
M & L for Dismantling of old servo motor and supply and fix new servo motor of existing size and cap complete all as specified and directed.
M & L for Dismantling of old carbon brush with carbon holder incl S & F new one complete all as specified and directed
S & F in Replacement of brass studs fixed for input and output of stabilizer with brass nuts for upto 160 KVA capacity complete all as specified and directed
M & L for Painting to voltage stabilizer old painted surface of steel after cleaning scrapping and preparing and filling cavities and providing two coat of synthetic enameled cream paint with spray gun process to voltage stabilizer of cap upto 160 KVA complete all as specified and directed
M & L for Filtration, dehydration of Voltage Stabilizer oil as drain out from Voltage Stabilizer vide Sch 'A' srl item No. 37 here-in-above to make the oil fit for reuse by improving its dieelectric strength not less than 40 KV below 40 KV dielectric strength oil shall be replaced with new oil (new oil for toping / or for replacement shall be measured and paid separately under appropriate item of Sch 'A') here-in-after. complete all as specified and directed
Supply, treating (dehydrating), filling new Voltage Stabilizer oil in Voltage Stabilizer for topping up levels or for replacement of unfit oil. New oil having dielectric strength not less than 60 KV and shall be conforming to IS 335. complete all as specified and directed
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable of size 25 Sqmm for submersible pump motors complete all as specified and directed
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable for of size 35 Sqmmsubmersible pump motors complete all as specified and directed
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR I including necessary earth work in type strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr complete all as directed including testing complete on completion. connected to earthing test point all as specified Note for item No. 51 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The qty above the 7.5 RM shall be measured & paid separetely.
M & L for Cutting of existing DI pipe line of 150/100 mm bore in potion for taking connection including excavation and earth work complete all as specified and directed
M & L for Servicing of sluice valves cast iron body by greasing/oiling using T&P as required as per manufacturer’s instructions & providing gland rope of superior quality to stop any leakage of sluice valves of size 80 mm to 200 mm diameter including replacement of defective brass check nuts complete all as specified and direceted.
Supply & fixing for GI strip 32x6mm on wall/batten or recessed or buried in ground all as directed by Engineer-in-Charge.
M & L for Cleaning of over head water tank by draining out water from the tank, removing sludge, mud or any other foregin materials from the bottom and internal surface and cleaning by wire brushing, washing internally by using bleaching powder and applying 2 coats of lime washing including re writing the date of cleaning, capacity of the tank with white paint on black back ground & external painting applying two coat of cement base paint including painting of steel and iron surface like railings and CI pipe line etc (welding to steel railing / ladder if required) with two coats of synthetic enamel paint over a coat of primer etc complete for the following capacities all as directed by Engineer-in- Charge.
50000 gallons at 18m staging.
100000 gallons at 18m staging.
Material & labour for Pumping out liquid and Taking out setteled sewage sludge/silt from STP Screening Bed & Sewage Collection Chamber, with the help of sewage suction pump and transporting & Disposed off the material minimum 5 KM away from the site to a low lying area (Isolated/No man area) and covering with a layer of soil but not less than 25 cm thick as directed.
Material & labour for Pumping out liquid and Taking out setteled sewage sludge/silt from STP, Clarifire Chamber 01 & 02, sludge digester and reaction room complete, with the help of sewage suction pump and transporting & Disposed off the material minimum 5 KM away from the site to a low lying area (Isolated/No man area) and covering with a layer of soil but not less than 25 cm thick as directed.
M & L for Cleaning of STP, Clean water semi under ground sump (Ecko Lake) by draining out water from the sump with portable pump sets, removing sludge, mud or any other foregin materials from the bottom and cleaning internal surface by wire brushing, washing internally by using bleaching powder and applying 2 coats of lime washing including painting with cement base paint internal & external wall surface etc complete. Note :- (i) T&P required for cleaning the OHT/Sewage water tank shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor.
Supply and filling PP Floating media to top up the Bio reactors as per existing complete all as specified and directed
Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out for lifting/ taking out of sludge/silt accumulated inside drying sludge bed of 1-06 Nos bed of size 9.0x9.0x1.2 M, making necessary arrangements and disposal of the same to the out side of 213 Transit Camp Jammu complete all as specified and directed by Engineer in charge
Supply and mix bleaching powder stable Gde-I confrming to IS specification 1665/89 ( second revision ) minimum available chlorine percentage by mass 34%+1% in 25 Kg polythene HDPE bags duly marked date of manufacturing and batch No. of fresh lot. Make Vikram SBP brand of M/S Grasim industries LTD/M/s Rayalaseema Hi strength Hypo ltd?DCM Shriram ltd oer equivalent make approved by E-in-C's Br. Note : The contractor shall deliver the same as per the site requirement and direction of Engineer-in-charge.
Supply and mix calcium Hypo Chloride granular in factory sealed HDPE container ( 45 kg Each) decomposing at 177C, Mol Wt:142.98, Toxicity : Oral rat LD : 850 mg/kg having chlorination concentration level 70 %Make- Puri chlor (Sree Rayalaseema Hi- strength Hypo Ltd) of equivalent make as per approved by engineer-in-Charge (E-in-C's branch approved only)
M & L for Transporting air compressor and other allied equipment/ material to and from the site of T/well, installation of machinery and dismantling there of complete all as specified and directed
M & L for Re-development of tubewell with air compressor of adequate capacity (not less than 250 cfm) as per specification till the availibility of sand free clear water, subject to minimum of 40 hrs of operation of air compressor complete all as specified and directed.
M & L for Stablization and yield testing of tubewell by using Submersible pump of adequate capacity as per specification (subjected to minimum of 8 hrs of development with Submersible pump ) including conduction of sounding test (50000 for 8 Hrs).
M & L for Dismantling and and takingout Submersiable pumpset complete from well complete all as specified and directed.
M & L for Lowering of Pumset complete with column pipe into well after completion of all operation and wrks including replacemnt of nuts, bolts, washers and gasket of suitable size.complete all as specified and directed
M & L for Dismantling and taking down carefully flood light, street light /perimeter lighting luminaries from its position of any size/wattage from over head line poles or from elevated sentry post for carrying out repair/replacement of burnt/worn out accessories and removing unserviceable items from site and depositing to MES store yard at Nagrota, including material and labour for replacement of worn out wiring with PVC insulated copper conductor single core cable 1.5 sqmm size, connector block, screws etc. Refixing the fitting after repair to its position compllete all as directed by Engr-in-Charge.(Note- Accessories/components required for replacement i.e Driver, Surge protection device shall be measured and paid separately under relative item of Sch 'A' ) Note : Contractor responsibility is to liase with the department concerned for LT supply shut down required to carry out the work & also ensure the safety of labour employed by giving them safety equipments like helmet, gloves, safety belt , discharge rod etc and nothing extra shall be permisissible in this account.
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 25 to 60 W capacity complete all as specified and directed
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 72 to 100 W capacity complete all as specified and directed
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 120 to 180 W capacity complete all as specified and directed
Supply and Fixing in replacement of unsv burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity complete all as specified and directed
Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 60 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box(sintex make) conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 1 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable incl taking down old unsv complete all as specified and directed.
Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 60 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box(sintex make) conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable incl taking down old unsv complete all as specified and directed. Make: Swadeep -02EC12kW1P , or Equivalent to Indoasian /Legrand
S&F of 90 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in- Charge
S&F of 60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in Charge . Make: HPL cat Part No HPLLEDSL60WBSHLM or equivalent in PS
S&F of 120W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Ant dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture . The luminaire should have a minimum system lumen output of 14400 lumens and 120 Watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a sysytem life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lamp and gear compartment ) and Mechanical impact resistance ratinfg of IK>=07. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india .LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including complete electrical connection with fixing arrangenment on pole or wall and taking down unsv light fittings complete all as specified and directed by Engr-in-Charge .
Supply and fixing Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 1 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6 A 10 KA 240V -01 No. with fixing arrangement fixed properly to pole/fixed on wall with MS Clamps 25x5 mm and nut and bolts complete all as specified and directed by the Engineer-In-Charge.
Supply & Fix street light brackets fabricated out of medium grade GI pipe of 50 mm dia, 1.5mtr long bent to shape suitable for street light fittings with two sets of clamps made out of mild steel flat iron suitable for fixing on HT/LT poles with nuts, bolts and washers all as directed including dismantling the existing brackets etc complete all as specified and directed
S & F in repair MCB TPN 16- 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed
S & F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed
S & F in repair MCB SP 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified and directed
S & L cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor,1100 volts grade,cross sectional area 4 core 35 Sqmm .Note : Excavation, returning and refilling will be measured and paid separately.
All as per ser No 144 but 25 Sqmm 4 core complete all as specified and directed
All as per ser No 144 but 16 Sqmm 4 core complete all as specified and directed
All as per ser No 144 but 10 Sqmm 4 core complete all as specified and directed
M & L for Sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed
M & L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat complete all as specified and directed
M & L for Old Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ obtained from excavation all as directed by engr in charge.
Supply and fix DWC pipe for cable protection with outer dia 50 mm and inner dia 38 mm including suitable size of coupler for connection of pipe complete all as specfied and directed. Note : Pipe are manufactured as per IS 16205 ( Part-24) have a smmoth internal surface and corrugated external surface for cable protection
Supply and fix aluminium lugs of any type / shape of capacity from 10 Sqmm to 25 Sqmm complete all as specified and directed
Supply and fix aluminium lugs of any type / shape of capacity from 35 Sqmm to 95 Sqmm complete all as specified and directed
Supply and fix aluminium lugs of any type / shape of capacity from 120 Sqmm to 300 Sqmm complete all as specified and directed
S&F Extension link four set for MCCB of cap 125/160 Amp. complete all as specified and directed
S&F Extension four link set for MCCB of cap 250 Amp complete all as specified and directed.
S&F Extension four link set for MCCB of cap 400 / 630 Amp. complete all as specified and directed
S&F in repair for fabrication and installation of feeder pillar box outdoor canopy type, size 40cm (Height) x 30 cm (width) x 12 cm (thick), size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut bolt, & 8 Nos aluminium cable socket suitable for upto 120 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25mm x25mm, 400 mm long as per sample including taking down complete all as specified and as directed.
Taking down service wire from street light poles & providing new 1100 V Grade PVC insulated,aluminium conductor & overall PVC sheathed in service connection with 2 single core cables of size 6 Sqmm & connecting to light fittings/terminal boxes complete all as specified and directed
Taking down service wire from street light poles & providing new 1100 V Grade PVC insulated,aluminium conductor & overall PVC sheathed in service connection with 2 single core cables of size 10 Sqmm & connecting to light fittings/terminal boxes complete all as specified and directed
Nitika electricals and engineers works (BID ID -3377295)
MAMTA ENTERPRISES (BID ID -3377110)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .