GE
GE 860 EWS
SPECIAL REPAIR TO BLDG NO T-56 AND T-141 OF CERTAIN UNIT AND OTHER SANCTIONED WORSPECIAL REPAIR TO BLDG NO T-56 AND T-141 OF CERTAIN UNIT AND OTHER SANCTIONED WORKS AT KARU AND KIARI UNDER GE 860 EWS
2022_MES_506181_1
8170/2021-22/E8
Open Tender
Civil Works
Item Rate
270 days
Karu
Class D Category a i and b i
9 documents required · 9 mandatory
₹500
Yes
GE 860 EWS
₹67,000
Yes
19 Apr 2022
5 Feb 2022
14 Mar 2022
5 Feb 2022
7 Mar 2022
20 Feb 2022
Amount
SECTION 1: SPL REPAIRS TO BLDGS AND OTHER SANCTIONED WORKS AT KARU
Dismantling wall & ceiling boards (fibre, insulation etc ) or insulation boards, slabs, blankets any thick ness including cover fillets all as specified & directed by the Engr-in-Charge.
Dismantling of timber scantling/fillets, rails, posts, rafters, purlings, etc in framed work under 40 sq cm in any position complete all as specified and directed by Engr in Charge
M&L for 2nd class hard wood Plain fillets exc 13 Sqcm but n exc 25 Sqcm in square, rectangular or triangular in section, clean sawn, secured with nails etc complete all as specified and directed by Engr-in-Charge
M&L for 9mm thick pre laminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame works on walls complete all as specified and directed by Engr in Charge
M&L for 4mm thick (3 Nos of Ply) Veneered decorative plywood of grade 1 (with BWR resin) with one decorative veneers face, fixed with Nails to timber frame work on ceilings etc complete all as specified and directed by Engr-in-Charge
M&L for preparation of newly or previously untreated wooden/plywood surfaces and applying one coat of finishing coat of varnishing over one coat of undercoating, over 10 cm in width or girth complete all as specified and directed by Engr-in-Charge
M&L for 2nd class hard wood corner beading exc 6 but n exc 13 sqcm bullnosed splayed chamfered or rounded on one edge or face complete all as specified and directed by Engr in charge
Taking down of chowkhats with shutter (without taking of shutter from frame) including iron Mongries etc exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed by Engr in Charge.
Taking down, refixing in same opening, resecuring or easing & adjusting, without taking down shutters of any description exc 1 sqm and n. exc 2 sqm removing of unserviceable complete all as specified and directed by Engr-in-Charge
S&F of second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed by Engr in Charge
S&F of 35mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engr-in-Charge
S&F of 250mm length aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixed clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified and directed by Engr in Charge
Supply and fix 125 mm size medium weight cold rolled mild steel butt hinges complete all as specified and as directed by the Engineer-in-Charge
S&F of 200mm long, aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engr in Charge
S&F 150 mm Extruded aluminium alloy handles, fabricated type, anodised all as directed by the Engr-in-Charge.
M&L for two coat of synthetic enamel (ordinary tint each coat) over a coat priming with pink primer on new or previously untreated wooden surfacecomplete all as specified and directed by Engr in Charge
Taking down Chowkhats with shutter (without taking of shutter from frame) including iron mongries etc n exc 1.5 sq. m each complete all as specified and directed by Engr in Charge.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded duly one factory coat red oxide primer complete all as specified and directed by Engr-in-Charge
S&F of 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge
M&L for securing glass of any description in existing metal frames glazed with putty/beads including removing loose or decayed putty/beads, painting/oiling one coat on rebates, grooves, reputttying and painting/oiling puttied surface to match existing work (new length of frame reputtied shall be measured)
M&L for two coat of synthetic enamel paint over a coat of priming with red oxide, zinc chrome of new or previously untreated surfaces of steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described complete all as specified and directed by Engr in Charge
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete
M&L Non skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15 mm thick in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge
M&L for glazed ceramic tiles in vertical surface 300 x 450 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 10 mm thick in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level complete all as specified and directed by Engr-in-Charge
M&L for providing cement concrete 75mm thick Type C1 1:3:6 (Using 20mm graded crushed stone aggregate) in plinth protection etc complete all as specified and directed by Engr in Charge
Taking up or down 15mm bore steel tubing and connections including cleaning for refixing with all fittings complete all as specified and directed by Engr-in-Charge
Taking up or down 20mm bore steel tubing and connections including cleaning for refixing with all fittings complete all as specified and directed by Engr-in-Charge
S&F of 15mm bore medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors complete all as specified and directed by Engr-in-Charge
S&F of 20mm bore medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors complete all as specified and directed by Engr-in-Charge
S & F in repair of Stop valves 15mm bore fancy type, chromium plated screwed down, high pressure with crutch or buttrefly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr-in-Charge
Supply and fix in repair 15 mm bore bib tap chromium plated fancy type with capston head screwed down, screwed for iron pipe fixed in repairs all as specified and directed.
Dismantling of PVC water tanks 500 ltrs capacity complete all as specified and directed by Engr-in-Charge
S&F 20mm bore ball brass valve, high pressure with polythene ball & float complete all as specified and directed by Engr-in-Charge
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge
S&F of galvanised, corrugated mild steel sheeting 0.50 mm thick with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws with rubber washers with grade of zinc coating 275 complete all as specified and directed by Engr in Charge
S&F of 0.50mm thick plain mild steel sheeting in ridges, hips, valley gutters,drip and straight flashings (length and girth as fixed) fixed with L-type or J-type or cranked hook bolts in lieu of screws with rubber washers with grade of zinc coating 275 complete all as specified and directed by Engr in Charge
M & L for two coat of synthetic enamel paint of approved tint on steel and iron surfaces of any description over 10 cm width or girth not otherwise described including preparing new zinc(or galvanised) surfaces to receive painting by coating with mordant solution incl washing and cleaning, etc. over a coat of red oxide complete all as specified and directed.
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
M&L point wiring complete One light / fan point controlled by one no, 1-way, 5 Amps switch. with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & PVC casing and capping of 25 mm and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings / junction boxes / inspection covers etc, with and incl concealed PVC box of suitable size flush with wall surface, covered with & incl 3 mm thick bakelite, laminated hylem sheet / Gang box for top cover suitable for fixing of piano type switches / sockets etc, complete all as specified and directed for the following :- (Note : The cost of PVC box with 3 mm thick bakelite, laminated hylem sheet top cover is deemed to be included in quoted rate.)
All as per srl item no. 40 here-in-before but for one socket outlet 3 pin, 5 Amps on independent board.
All as per srl item no. 40 here-in-before but for one socket outlet 3 pin, 5 Amps on same board..
All as per srl item no. 40 here-in-before but with 2.5 sq mm FRLS copper wire and with 2.5 Sqmm FRLS copper earth wire for indpendent 15 Amp point. Note: The point wiring for power point will not be mixed with light/fan point circuit or not in the same conduit.
S&F Switch piano type, single pole, one way, 5 amps, 230 volts, complete all as specified and directed.
S&F Socket outlet multipurpose 2 in 1, 5 Amp,flush type, 230 volts complete all as specified and as directed by Engr-in-charge.
Supply and fixing switch socket combination multi purpose 2 in 1, 3 pin 5 Amp and 15 Amp, flush type complete all as specified and as directed by Engr-in-charge
S&F in replacement of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 08 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
S&F in replacement of Distribution Board, double Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F of MCB, C Curve type, 10 kA, 32 Amp, DP with over load and short circuit protection, complete all as directed.
M& L for submain wiring using two runs of 4 sqmm single core PVC insulated cable with copper conductor multi stranded 1100 volts through new non metalic PVC casing capping including one run of 4 sqmm single core PVC insulated cable with copper conductor multi stranded copper earth wire in green colour, connection to DB with thimbling complete as specified and directed (Note: Two runs of sub main wire 4 sqmm including one run of 4 sqmm earth wire and rigid non metallic PVC casing capping shall be measured as one unit per RM.)
S&F of MCB, C Curve type, 10 kA, 6 to 40 Amp, Single Pole with over load and short circuit protection, complete all as directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore (7.5 m long) including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2009 Part-I and connecting to CBDB’s as specified or indicated including testing on completion
Supply & Install Pumping sets, centrifugal, electric driven three phase 440 volts of capacity 15 HP exclusive of starter and including PCC foundation in PCC 1:2:4 type B1 incl grouting bolts etc , nuts and washer complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of GI tubing in trenches and getting out in hard and dense soil complete all as specified by Engineer - in - charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply & laying of GI/DI pipeof the following sizes and grade complete with fittings (such as bends, elbows, tees, short pieces, connectors, caps, plugs, unions and screwed socket joints etc) laid in trenches complete as directed by Engr-in-Charge, of following sizes (Note : when pipe laid in straight line then the 3rd length is required to be connected by union
PPR pipe 3 layer SDR 7.4 , 20 mm dia
PPR pipe 3 layer SDR 7.4 , 25 mm dia
GI pipe, Med grade 20 mm dia
GI pipe, Med grade 25 mm dia
GI pipe, Med grade 50 mm dia
GI pipe, Med grade 80 mm dia
Supply and fixing gun metal, globe or gate valve for 50 mm dia pipe with iron wheel head, screwed both ends ISI marked complete all as specified and directed.
Supply and fixing gun metal, globe or gate valve for 25 mm dia pipe with iron wheel head, screwed both ends ISI marked complete all as specified and directed.
Supply and fixing gun metal, globe or gate valve for 20 mm dia pipe with iron wheel head, screwed both ends ISI marked complete all as specified and directed.
S&F 500 Ltrs capacity Rotaional moulded, polythene water storage tanks triple layered (cylindrical shape with vertical threaded top closed) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engr-in-Charge
S&F 1000 Ltrs capacity Rotaional moulded, polythene water storage tanks triple layered (cylindrical shape with vertical threaded top closed) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engr-in-Charge
Construction of Staging of size 1.3 m x 1.2 m x 1.25 m using precast cement concrete solid block masonary type C-1, 1:3:6 (20mm graded crushed stone aggregate), exceeding 10cm in width and setting in cement mortal 1:6 over 150mm thick PCC 1:3:6 (nominal mix) type C-2 (using 40 mm graded crushed stone aggregates) complete, 10mm thick rendering in cement mortar 1:4 on concrete surface finished even & smooth without using extra cement The masnory work including PCC sub base shall be 0.20 m below GL including neccessary earth work complete all as specified and directed by Enginner-in-Charge.
Construction of Staging of size 1.3 m x 1.5 m x 1.60 m using precast cement concrete solid block masonary type C-1, 1:3:6 (20mm graded crushed stone aggregate), exceeding 10cm in width and setting in cement mortal 1:6 over 150mm thick PCC 1:3:6 (nominal mix) type C-2 (using 40 mm graded crushed stone aggregates) complete, 10mm thick rendering in cement mortar 1:4 on concrete surface finished even & smooth without using extra cement The masnory work including PCC sub base shall be 0.25 m below GL including neccessary earth work complete all as specified and directed by Enginner-in-Charge.
Supply & fixing cast iron sluice valve for water supply purposes with CI drilled flanged end internally cast for 80 mm nominal bore class PN 1.6 horizontal type conforming to IS 760, ISI marked with stainless steel spindle & iron wheel non using type including jointing material complete such as rubber assertion packing rings with requisite no of nuts & bolts , washers of requisite size etc all as specified and directed by the Engr-in-Charge.
S&F cast iron non return valve (NRV) or reflex valve for water supply purpose, single door pattern for 80 mm bore pipe conforming to IS 5312-198, heavy duty ISI marked with CI drilled flanged ends (integrally cast) including packing material such as rubber inserting packing rings with requisite numbers of nuts & bolts washers of requisite size complete all as specified by Engr-in-Charge.
Construction of stone masonary valve pit chamber of size 90cm x 90cm x 160 cm (internal dimension) including all necessary excavation and earth work in hard/dense soil and disposal of surplus soil to a distance not exceeding 50 metre as directed including PCC in foundation of the mixture (1:4:8) type D-2, stone masonry in cement mortor 1:4, rendering 15 mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externaly as the work proceeds in the same mortar as of stone masonary including MS frame (made out of angle in 40x40x6mm) and MS steel cover 3.15 mm thick with handle and locking arrangement with hinges angle iron flat as required at site.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth strip 25x4 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 32 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM and frame of suitable size with handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No.3 of SSR 2009 Part-I and connecting to pump motores, MCB DB’s earth test point all as specified or indicated including testing on completion.
Supply, installation, testing and commissioning, in replacement, of Feeder Pillar box , cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, and mild steel angle iron frame complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC. Feeder Pillar box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings. (a) MCCB 32 Amp three pole 10 KA 415 Volt = 01 Nos (I/C)
M&L for PVC insulated and sheathed multi strandard 3 core 25 sqmm flat 1100 volts grade electric copper submersible cable complete connection of motor all as specied and directed by Engineer-in-Charge.
SECTION 2 : PROVISION OF HARD STANDING AT KIARI
Surface dressing n. exc 15cm deep in hard/dense soil.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as spd & directed.
M&L for cement concrete 100mm thick type D-2 using 40mm graded stone aggregate over rammed earth as in sub base to receive floor finish etc complete all as specified.
M&L for sand filling under floors or in foundation including watering and consolidation.
M&L for Machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and pigment.
M & L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges type B1 1:2:4 (20mm graded aggregate)
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m depth and n.exc 10 Sqm on plan and getting out in any kind of soil complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (Nominal mix) using 40mm graded stone aggregate as in foundation filling and similar work complete.
M&L Precast cement concrete block masonry type C1 1:3:6 (20mm graded aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified.
Returning filling in incl spreading, watering and well ramming in layer n.exc 25 cm in layers complete all as specified.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.50 m above the starting point.
M&L for rendering 15mm thick, in cement mortar 1:4 on PCC block walling or concrete surfaces and finished even and fair without using extra cement complete.
M&L for two coats of cement base paint over a coat of white wash on walls after preparation of new-plastered surface complete, all as specified and directed.
THINLES OTZER
osho traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .