Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.2 CrAccepted-Finance 00 MEERANPUR SADARALI FAREEDPUR KALAN TANDA AMBEDKAR NAGAR UTTAR PRADESH 224145 UDYAM UP 04 0001727 | AMBEDKAR NAGAR | UTTAR PRADESH | 224145 | ₹8.2 Cr | 1 | Accepted-Finance Lowest Amount Quoted |
| 2 | 2₹8.6 CrRejected-Finance | ₹8.6 Cr | 2 | Rejected-Finance higher Amount Quoted |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected by Tender committee |
Tender Value
₹9.5 Cr
EMD Value
₹19 L
Closing Date
29 Apr 2026, 12:00 pmClosed
S.E.PMGSY Circle PWD Prayagraj
Office of the S.E.PMGSY Circle PWD Prayagraj
Construction work of residential and non-residential building of 02 unit fire station in Block Holagarh of Phaphamau Assembly Constituency of Prayagraj district. including electrical work
2026_CEPMP_1137497_1
516/Nivida(Bhavan)pmgsy/26 Date- 07.04.2026
Open Tender
Civil Works - Buildings
365 days
Holagarh Prayagraj
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,714
₹19 L
Office of the S.E.PMGSY Circle PWD Prayagraj
16 May 2026
16 Apr 2026
29 Apr 2026
16 Apr 2026
29 Apr 2026
16 Apr 2026
23 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work in excavation by mechanical means {Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil. As per DSR No.2.6.1 | - | Cum | - | - |
| 2 | Excavating trenches by mechinical I manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m All kinds of soil. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. As per DSR No.2.10.1.2 | - | Cum | - | - |
| 3 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides offoundation etc. complete for all lift. As per DSR No. 2.25(a) | - | Cum | - | - |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. As per DSR No2.25 | - | Cum | - | - |
| 5 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. As per DSR No.2.27 | - | Cum | - | - |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). As per DSR No.4.1.8 | - | Cum | - | - |
| 7 | Cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement sluny, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate. As per DSR No.11.3.1 | - | Sqm | - | - |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level . Concrete of M25 grade with minimum cement content of 330 kg /cum. As per DSR No.5.33.1.1 | - | Cum | - | - |
| 9 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level . Concrete of M30 grade with minimum cement content of 350 kg /cum. As per DSR No.5.33.1.2 | - | Cum | - | - |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana I Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M25 grade with minimum cementcontent of 330 kg /cum. As per DSR No.5.33.2.1 | - | Cum | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
CBD.pdf
Tender Documents • 2.78 MB
BOQ_2124131.xls
BOQ • 0.77 MB
Download all tender documents and submit your bid