Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.5 LAccepted-AOC | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹17.7 L+₹78,121 (4.61%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | 2 | Rejected-Finance Other than L1 | |
| 3 | 3₹20.7 L+₹3.8 L (22.4%)Rejected-Finance | 3 | Rejected-Finance Other than L1 | |
| 4 | 4₹22.6 L+₹5.7 L (33.5%)Rejected-Finance A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | 4 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Sept 2024, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/MAINT OF INTERNAL WIRING ALONGWITH ACCESSORIES, LED FITTING, MCBs, DBs INCLUDING REPAIR TO ACs/DESERT COOLERS AT DGQA BADARPUR UNDER GE (AF) TUGHLAKABAD
2024_MES_655568_1
GE/TKD-33/2024-25
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹0
₹50,000
Yes
11 Nov 2024
9 Jul 2024
6 Sept 2024
9 Jul 2024
4 Sept 2024
23 Jul 2024
Amount
Taking down carefully copper /Aluminium point wiring (light, fan, socket or power) complete, Fittingssuch as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed by Engr-in-charge.
M&L for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and include PVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 1.5 sq mm as earth wire, connected to common earth dolly suitable for mounting modular switches incl modular metal flush boxes and modular face platecomplete all as specified and as directed by Engr-in-charge. Note: The works includes cutting of chases and making good disturbed surfaces and rate deemed to included in quoted rate.
One Light point controlled by one way switch
One fan point controlled by one way switch and fan regulator on same switch board
One 3 pin socket outlet point 5 Amp on same board
One 3 pin socket outlet point 5 Amps on independent board
M&L for bell/buzzer point controlled by one push button on the same board with other swithces or independent with cables 1.5sq. mm size
All as per item no 2.00 above but One 3 pin socket out let 15 Amps on independent board, with cables 4.0 Sq mm size and earth wire 4.0 sqmm.
One light point controled by two way switches with cable of size 2.5 sqmm nominal area and 2.5 Sqmm earth wire
Taking out old U/S submain wiring of any size and type complete all as specified and as directed by Engr-in-charge.
M&L sub main wiring with multistranded FRLS copper conductor cable PVC sheathed in and including concealed in brick wall/RCC as per the site sondition, providing suitable PVC conduit with two runs of 10.0 Sqmm and 10.0 Sqmm FRLS copper conductor as earth wire and connected to earth dolly complete all as specified and as directed by Engr-in-charge. Note: The work includes cutting of Chasis and making good the disturbed surfaces.
All as per sl item No 7 but for two runs of 6.0 Sqmm FRLS copper conductor as earth wire.
All as per sl item No 7 but for two runs of 4.0 Sqmm FRLS copper conductor as earth wire.
M&L in replacement for modular socket outlet 6A, 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular socket outlet 6A/16A, 2/3 pin combined 2 module complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular switch 1 way 6 Amps 1 module, suitable for 230 Volts Ac supply complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular switch 2 way 6 Amps 1 module, suitable for 230 Volts AC supply complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular switch 1 way 15/16 Amps 1 module, suitable for 230 Volts Ac supply complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular white cover plate with frame 2 module complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular white cover plate with frame 3 module complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular white cover plate with frame 6 module complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular white cover plate with frame 8 module complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular metal/PVC flush box 2/3 module complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular metal/PVC flush box 6 module complete all as specified and as directed by Engr-in-charge.
M&L in replacement of modular metal/PVC flush box 8 module complete all as specified and as directed by Engr-in-charge.
M&L in replacement of ceiling rose 3 phase/PVC/ polycarbonate isolated body complete all as specified and as directed by Engr-in-charge.
S&F in replacement of step type elctronic fan regulator Modular type, single phase 220 V , 2 module type complete all as specified and as directed by Engr-in-charge.
S&F in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Ding Dong Bell,single phase, 230 volt AC,50 Hz complete all as specified and as directed by Engr-in-charge.
M&L in replacement, Batten holder bakelite, AC, 220 Volts, complete all as specified and as directed by Engr-in-charge.
M&L in replacement of Bell push, Modular type, one module suitable for 230 Volts AC supply complete all as specified and as directed by Engr-in-charge.
M&L in replacement of for switch piano flush type single pole one way 5 amps complete all as specified and as directed by Engr-in-charge.
M&L fin replacement of or switch piano flush type single pole one way 15 amps complete all as specified and as directed by Engr-in-charge.
M&L in replacement of Socket outlet, 3 pin 2 in 1 of 5 amps capacity complete all as specified and as directed by Engr-in-charge.
M&L in replacement of Socket outlet, 3 pin 2 in 1 of 15 amps capacity complete all as specified and as directed by Engr-in-charge.
M&L in replacement of Switch socket combination box type 2 in 1 3 pin 5 and 15 amps flush type complete all as specified and as directed by Engr-in-charge.
M&L in replacement of Switch socket combination box type 2 in 1 3 pin 5 amps flush type complete all as specified and as directed by Engr-in-charge.
M&L in replacement of distribution boards in sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps complete all as specified and as directed by Engr-in-charge.
M&L in replacement of distribution boards in sheet metal enclosure for MCB's (D.B) 8 way (SPN) 200 Amps rated bus bar complete all as specified and as directed by Engr-in-charge.
M&L in replacement of distribution boards in sheet metal enclosure triple pole and neutral 415 Volts 4 way (TPN) Double door type complete fixed with concealed on walls/on surface and matching with existing surface complete all as specified and as directed by Engr-in-charge.
M&L in replacement of distribution boards in sheet metal enclosure triple pole and neutral vertical Loadline 415 Volts 8 way, IP 43 of metal door type complete with 100 Amps MCCB, Double door type complete all as specified and as directed by Engr-in-charge. Note- MCCB will be measured in quoted rate by the contractor.
M&L in replacement of MCB 240 volts SPN 06- 40 amp 10KA breaking capacity, ISI marked complete all as specified and as directed by Engr-in-charge.
M&L in replacement of MCB 240 volts SP 6- 32 amp 10KA breaking, capacity, ISI marked, complete all as specified and as directed by Engr-in-charge.
M&L in replacement of MCB 415 volts TPN 63 amp 10KA breaking, capacity, ISI marked, complete all as specified and as directed by Engr-in-charge.
S&F in replacement of wall mounted LED batten 20 watt 6500K, extruded polycarbonate for efficent heat dissipation & integrated electronic driver 230 Volt, AC, single phase, 50 Hz, white/warm white in colour incl all accessories prewired including making necessary electrical connection with 3 core copper coductor and testing complete all as specified and as directed by Engr-in-charge.
S&F in replacement wall mounted LED batten 10 watt 6500K, extruded aluminium heat sink provided for efficent heat dissipation & integrated electronic driver ,230 Volt, white/warm white in colour incl all accessories prewired including and making necessary electrical connection with 3 core copper coductor and testing complete all as specified and as directed by Engr-in-charge.
S&F in replacement 2'x2' size LED panel lighting luminaire glare free illumination suitable fr false ceiling (armstrong/Grid) fitting size 600x600x70 mm (LXWXH) of 42 watts capacity recess mounting with high brightness SMD LEDs completee incl taking down old UNSV fittings complete all as specified and as directed by Engr-in-charge.
S&F in replacement 1'x1' size LED panel lighting luminaire glare free illumination suitable fr false ceiling (armstrong/Grid) fitting size 284x284x23 mm (LXWXH) of 12 watts capacity recess mounting with high brightness SMD LEDs completee incl taking down old UNSV fittings complete all as specified and as directed by Engr-in-charge.
S&F in replacement of LED bulb 9 watt white/warm white in colour and pin/thread typesuitable for B22 base complete all as specified and as directed by Engr-in-charge.
S&F in replacement of LED bulb 12 watt white/warm white in colour and pin/thread type suitable for B22 base complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement copper wire in wiring circuits as per site requirements PVC insulated single core 1.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement copper wire in wiring circuits as per site requirements PVC insulated single core 2.5 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement copper wire in wiring circuits as per site requirements PVC insulated single core 4 Sqmm 1100 volts grade multi stranded conductor complete all as specified and directed by Engr-in-charge.
M&L for replacement of polycarbonate Plug top of 5 Amps, 3 pin 240 Volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement decorative wall light fixture suitable for 15 watt LED lamp B22 base City 3 complete all as specified and as directed by Engr-in-charge.
S&F in replacement Ultra slim COB Downlighter light of 10 watt in round shape 78 mm dia with durable aluminium housing, reflector for anti-glare and smooth light distribution, contolled beam angle and adustable focus, energy saving, environmental friendly complete all as specified and as directed by Engr-in-charge.
S&F in replacement Ultra Slim Downlighter light of 15 watt in round shape 185 mm dia with durable thermally conductive plastic housing & in-built driver, eye protection provided by acrylic diffuser , energy saving, environmental friendly complete all as specified and as directed by Engr-in-charge.
M&L for replacement of polycarbonate Plug top of 15 Amps, 3 pin 240 Volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED bay lights high efficiency downlighter light of 150 watt in round shape 185 mm dia with durable aluminium housing, reflector for anti-glare and high lumen efficiency of >130lm/w , energy saving, environmental friendly complete all as specified and as directed by Engr-in-charge.
S&F in replacement Ultra Slim surface mounting round LED of 6 watt downlighter designed with excellent thermally managed aluminium pressure round shape 185 mm dia with durable thermally conductive plastic housing & in-built driver, eye protection provided by acrylic diffuser, energy saving, environmental friendly complete all as specified and as directed by Engr-in-charge.
Taking down carefully storage type water heater (Geyser) after disconnecting of electric/water connections, removing all scale & dirt by descaling of depositing inner, outer tank & heating elements by HCL or aquat clear pidlite solution, stoppage of minor leaking by soldering/brazing of inner CU tank & replacement of defective/wornout/unserviceable nuts, washers(New components/parts shall be measured & paid separately as supply only herein after) & refixing geyser in its original location including hoisting connecting to water, electrical connection & testing proper functioning of geyser including earthing to the entire satisfaction of Engr-in-Charge for various makes of geysers of following capacity:- Note: Necessary spare parts like Non return valve, stop valve, bib tap/ PVC connection /Copper connections cable, glass wool, element, thermostat, storage tank, geyser assembly, indicator etc shall be measured and paid separately.
25 litres capacity
35/50 litres capacity
Supply and replace the heating element with ISI marked element of capacity 1.5/2.0 KW, suitable for 230 volts, AC, 50 Hz single phase power supply of storage type water heaters of compatible type duly making all connections by replacing inter connecting copper conductor cables and removal of the old unserviceable element complete all as specified and directed by Engr-in-Charge.
S&F thermostat suitable for 25/35/50 litres capacity storage type water heaters of size 9/11 inch long with temperature range of 0-90 degree centigrade including removal of old unserviceable one complete all as specified and directed by Engr-in-Charge.
S&F check/non return valve gun metal of size 15mm bore with necessary GI fittings required at site including removal of old one complete all as specified and directed by Engr-in-Charge.
S&F in replacement of stainless steel assembly for housing the Heating element, 6/8/9 Holes type for 50/35/25 litres for storage type Geyser complete all as specified and directed by Engr-in-Charge.
S&F in replacement of stainless steel tank for 25 litres storage type Geyser with MS collar with rated pressure not less than 7 kg/Sq cm as per existing pattern complete all as specified and directed by Engr-in-Charge.
S&F in replacement of stainless steel tank for 35/50 litres storage type Geyser with MS collar with rated pressure not less than 7 kg/Sq cm as per existing pattern complete all as specified and directed by Engr-in-Charge.
S&F in replacement of glass wool for 50/35/25 litres storage type Geyser, as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement of safety valve ISI marked suitable for storage type Geyser of capacity 50/35/25 litres, as per sample complete all as specified and directed by Engr-in-Charge.
S&F PVC insulated 3 core copper conductor wire of size 2.5 Sqmm overall PVC sheathed for Geyser connection including taking down old one complete all as specified and directed by Engr-in-Charge.
M&L for PVC insulated 3 core copper conductor wire of size 1.5 Sqmm overall PVC sheathed including taking down old one complete all as specified and directed by Engr-in-Charge.
M&L for indicator lamp suitable for 25/35/50 litres geysers as per the existing sample in green and red colour including taking down old one complete all as specified and as directed by Engr-in-Charge.
M&L for after scrapping, cleaning incl preparation of surface of geyser and painting of Geysers and applying two coats of synthetic enamel paint with machine spray paint including writing the MES number on body of the Geyser duly taking down and refixing the connections, testing and commissioning after painting complete all as specified and as directed by Engr-in-Charge.
S&F of rubber ring gasket made out of superior rubber having holes to suit the hole of bar plate complete all as specified and directed by Engr-in-Charge.
S&F Bib tap of size 15 mm, PVC body with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-charge.
S&F PVC braided connection of size 15 mm dia , 18"/24" length with nuts suitable for Hot & Cold water connections of geysers complete all as specified and directed by Engr-in-charge.
Supply only teflon tape PTFE 12 metres long and 19 mm wide complete all as specified and directed by Engr-in-Charge.
Supply only bituminous self adhesive flashing tape of size 10 cm x 5 cm x 1000 cm long Heavy duty, silver or black in colour as per sample complete all as specified and directed by Engr-in-Charge.
M&L for dash fastener and screws suitable for fixing/hanging electric geysers of capacity upto 50 ltrs fabricated with bronze and having 10 mm bore and 150 mm long with internal nails all as per sample kept at AGE E/M office complete all as specified and directed by Engr-in-Charge.
Disconnecting , taking down & removing carefully the ceiling fan, exhaust fans, wall bracket fans, Pedestal Fans and air circulating fans etc, from existing position, from any height, of any description, any sweep and from any position / locations, sealing cable end, for repairs / servicing / overhauling / painting / numbering etc and hanging / fixing the repaired fans in same position or at position as directed by Engr-in-Charge after, dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing, fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades,connecting to existing electric sources with using new 1.5 Sqmm 3 core multistrandd PVC insulated copperwire (FRLS) to required length and testing at site to the entire satisfaction of Engineer-in-Charge. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation of fans to & from workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Remetaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under appropriate item of Sch ‘A’ (v) Writing of fan No. and painting of fans shall be measured and paid for separately.
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire(Gauge/weight of copper coils shall be as per exisitng fans) as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction including painting of fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White/grey) by spray machine including preparation of existing decorated surfaces of fans including engraving / painting MES No. on fan in capital letters of height not less than 20 mm on fan body complete as directed Engineer-in-charge for the following Fans:-
Rewinding of motor of ceiling fans 1200/1400 mm sweep complete all as specified and directed by Engr-in-Charge.
Ditto but rewinding of motor of exhaust fans of 225 mm sweep complete all as specified and directed by Engr-in-Charge.
Ditto but rewinding of motor of exhaust fans of 300 mm sweep complete all as specified and directed by Engr-in-Charge.
Ditto but rewinding of motor of exhaust fans of 350 mm sweep complete all as specified and directed by Engr-in-Charge.
Ditto but rewinding of motor of exhaust fans of 400 mm sweep complete all as specified and directed by Engr-in-Charge.
Ditto but rewinding of motor of exhaust fans of 600 mm sweep complete all as specified and directed by Engr-in-Charge.
Ditto but rewinding of motor of air circulating fan/wall mounting fans of 400 mm sweep complete all as specified and directed by Engr-in-Charge.
Ditto but rewinding of motor of air circulating fan of 600 mm sweep complete all as specified and directed by Engr-in-Charge.
Supplying only ball bearing No 6201 complete all as specified and directed by Engr-in-Charge.
Supplying only ball bearing No 6202 complete all as specified and directed by Engr-in-Charge.
Supply only gun metal bushes of any description and size to suit existing motor shaft including remetaling grinding & polishing of fan motor shaft to required shape/size complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in repairs capacitor of capacity 2.5 mfd (PVC body) in fans of any description and in any position complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in repair capacitor of capacity 3.15 mfd (PVC body) in fans of any description and in any position complete all as specified and directed by Engr-in-Charge.
M&L in replacement of the exhaust fan motor for 225 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge.
M&L in replacement of the exhaust fan motor for 300 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge.
M&L in replacement of the exhaust fan motor for 350 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge.
M&L in replacement of the exhaust fan motor for 400 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge.
M&L in replacement of the exhaust fan motor for 600 mm sweep complete with all accessories and depositing into AGE E/M Store yard of old one complete all as specified and directed by Engr-in-Charge.
Taking out the old unserviceable louvers of any type upto G+1 storey and S&F the exhaust fan louvers to suit 300 mm sweep exhaust fan made out of MS sheet heavy duty of 22 gauge as per sample kept at AGE E/M (AF) Tughlakabad duly applying two coats of paint over one coat of red oxide primer with all necessary fixing materials and making good the disturbed surface of wall both inner and outer side and match with the existing surfaces complete all as specified and directed by Engr-in-Charge. NOTE- Contractor will make all arrangements of safety devices and safety of their workmen and govt property while carying out the work.
All as per sl item No 87 but to carry out the work at G+2 & G+3 of approximate height upto 10 metres complete all as specified and directed by Engr-in-Charge.
All as per sl item No 87 but for 450 mm sweep exhaust fan complete all as specified and directed by Engr-in-Charge.
Taking down the old unserviceable exhaust fan from the existing position and M&L in replacement of exhaust fan of 230/250 mm sweep ventilating fan(Plastic/Steel body) speed 1350 rpm and power 60 watts suitable for 230 volts, 50 Hz and deposit the old fan into AGE E/M store yard at Vayusenabad complete all as specified and directed by Engr-in-Charge.
Taking down the old unserviceable exhaust fan from the existing position and Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers with all connected accessories and depositing old fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge.
Taking down the old unserviceable exhaust fan from the existing position and Supply and fix exhaust fan, plastic body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers with all connected accessories and depositing old fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, min air delivery 210 CFM with service value 5.00 BEE and taking down and depositing the old ceiling fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge.
S&F in replacement of new ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 900mm sweep, min air delivery 210 CFM with service value 5.00 BEE and taking down and depositing the old ceiling fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge.
M&L in replacement of wall fan of 450 mm sweep, 3 blade type, 1440 rpm, 80 watts with 3 speed rating suitable for AC supply, 230 volts, 50 Hz and deposit the old fan into AGE E/M store yard at Vayusenabad complete all as specified and directed by Engr-in-Charge.
Taking out the old unserviceable geyser from the existing position and S&F installation and testing of new Geyser of 25 litres capacity with copper inner tank, 5 star rating suitable for 230 Volts, AC supply, 50 HZ complete with all standard accessories depositing the old geysers at AGE E/M store yard at Vayusena bad complete all as specified and directed by Engr-in-Charge.
M&L in replacement for Earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) reinforced with 6 mm dia MS bars with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe connected to earthing list point complete all as specified and directed by Engr-in-Charge.
S&F in replacement of canopy for ceiling fan of size 1200/1400mm sweep of any make complete all as specified and directed by Engr-in-Charge.
S&F in replacement of down rod for ceiling fan 1200/1400mm sweep of size 15 mm dia upto 1 .5 mtr long duly painted with approved synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Hanging clamp suitable for the ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as specified and directed by Engr-in-Charge.
S&F in replacement Ball valve brass 20mm dia with iron handle screwed both ends for iron pipe and fixed including taking down old unsv valve complete all as specified and directed by Engr-in-charge.
S&F in replacement Ball valve brass 25mm dia with iron handle screwed both ends for iron pipe and fixed including taking down old unsv valve complete all as specified and directed by Engr-in-charge.
Attending complaint and taking down existing ceiiling/wall /exhaust fan/ tube light fittings/panel light/switch socket/batten holder and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator/desert cooler by highly skilled tradesman and carryout minor repair carefully (any capacity, any type) from building carrying out necessary repairing at E/M yard and refixing into the existing location including replacement of unserviceable/ defective spare parts i.e.(tube light fittings/panel light/switch socket/batten holder) and making good disturbed surfaces of walls, floors complete all as specified and directed by Engr-in-Charge.
Disconnecting U/S burnt out rotary/reciprocating compressor from existing electric and pipe line connections of Refrigerator of 165 ltr to 270 ltr capacity of any make / location, transporting and replacing with new compressor including connecting suction and discharge lines by copper brazing, refixing capillary filter, pressure testing with the help of nitrogen gas and flushing out the oil in condensor cooling coil , establishing vaccumed for dehydration complete all as specified and as directed by engr-in-charge.
All as per item no. 102 above but Water cooler of capacity 40 / 80 litres complete all as specified and directed by Engr-in-Charge.
All as per item no. 102 above but Window / Split type AC of capacity 1.5 TR complete all as specified and directed by Engr-in-Charge.
All as per item no. 102 above but Window / Split type AC of capacity 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement fan motor / condensor motor 230 Volts, 50 Hz, SP suitable RPM for water cooler of capacity 40 / 80, 60 / 120 and 60 / 150 litres including connecting / mounting brackets to base frame and testing complete all as specified and as directed by Engr-in-charge.
All as per item no. 103 above but of 230 Volts, 50 Hz, SP suitable for frost free refrigerator of capacity 165 to 270 litres complete all as specified and directed by Engr-in-Charge.
All as per item no. 103 above but suitable for window type AC of capacity 1.5 / 2 TR complete all as specified and directed by Engr-in-Charge.
All as per item no. 103 above but suitable for split type AC out door unit of capacity 1.5 / 2 TR complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement blower motor 230 Volts, 50 Hz, single phase 1.5/2 TR capacity complete all as specified and directed by Engr-in-Charge.
Supply and charging only refrigerent gas of required HD i.e hydrocarbon, R-134a, R-22 or R-12 or any latest version suitable for Refrigerators of capacity 165 to 270 ltr capacity including cutting copper pipe and sealing by brazing etc after charging gas as required and leak testing complete all as specified and as directed by Engr-in-charge.
All as per item no. 105 above but for Water coolers 40/80,60/120/150 ltr capacity complete all as specified and directed
All as per item no. 105 above but for Window / Split type AC of capacity 1.5 TR capacity complete all as specified and directed
All as per item no. 105 above but for Window / Split type AC of capacity 2 TR capacity complete all as specified and directed
Supply and fixing in replacement Condensor unit for refrigerator of capacity 165 to 270 litres of any model, type, size and capacity including testing including making all connections complete all as specified and as directed. NOTE: Gas charging shall be measured and paid separately
All as per item no. 106 above but for Water coolers 40/80,60/120/150 ltr capacity complete all as specified and directed by Engr-in-Charge.
All as per item no. 106 above but for Window AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-Charge.
All as per item no. 106 above but for Split type AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Cooling unit for refrigerator of capacity 165 to 270 litres of any model, type, size and capacity including making all connections complete all as specified and directed by Engr-in-Charge. NOTE: Gas charging shall be measured and paid separately
All as per item no. 107 above but for Water coolers 40/80,60/120/150 ltr capacity complete all as specified and directed by Engr-in-Charge.
All as per item no. 107 above but for Window AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-Charge.
All as per item no. 107 above but for Split type AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-Charge.
M & L for Detecting gas leakage of refrigerators, water coolers, window/split/ piller type AC's and creating vaccum , rectifying /arresting the leakages,testing for pressure drop , charging refrigrant gas in the unit to the required pressure complete all as specified and as directed by Engr-in-charge.
Supply & fixing in replacement running/starter capacitor 2.5/3.15/4.0/6.0 mfd, ,250 volts , AC, from cooling appliances complete all as specified and as directed by Engr-in-charge.
All as per item no. 109 above but of 45 mfd 6 pin complete all as specified and directed by Engr-in-Charge.
All as per item no. 109 above but of 50.0/6 mfd complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement thermostat suitable for window / Split type AC's, Water coolers, Refrigerators of any make, capacity and model and testing complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of capillary & filter suitable for AC , water cooler, Deep freezer, refrigerator complete all as specified and directed as specified by Engr-in-Charge
Supply and fixing in replacement over load protector suitable for window / Split type AC's, Water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement PVC pipe 32 mm dia for draining out waste water complete all as specified and as directed by Engr-in-charge
Supply and fixing in replacement Timer for refrigerator of existing specifications of any model, type, size and capacity complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Copper tube 1/4"/1/2"/3/8'/5/8' size , thickness greater than 0.7 mm complete for cooling appliances , of any model, type, size and capacity to suit the existing including connecting complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Heater of any size to refrigerator of any capacity from 165 to 270 litres of any model, type, size complete all as specified and as directed.
Supply and fixing in replacement Fan blade of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make complete all as specified and as directed.
Supply and fixing in replacement with new display assembly of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of front grill with air filter of window AC 1.5/2 TR of any make complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement with new Electronic card/ PCB of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing complete all as specified and directed by Engr-in-Charge.
S&F complete indoor unit of split type AC 1.5 TR in replacement of worn out unit Comprises of cooling coil, blower, blower motor, swing motor, swing blade filter, PCB, Thermostat etc complete all as specified and directed by Engr-in-Charge.
S&F complete outdoor unit of split type ac 1.5 TR in replacement of existing worn out indoor unit complete with outdoor fan motor, outdoor fan, condenser unit with cooling coil, copper/aluminium fins, wiring etc as per existing with connection for indoor and outdoor with copper tubing complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of old rusted desert cooler capacity 4000/5000 cum/hr made out of GI sheet 22 SWG complete with front panel and replacement of complete cooler body , U/S fan motor and U/S water Pump of approved make all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of fan blade made of GI sheet of heavy duty for desert cooler for any capacity complete all as specified and as directed.
Supply and fixing in replacement PVC flexible rubber pipe 15 mm dia for desert coolers complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement wood wool pad (set of 3 ) of suitable size to dessert cooler of capacity 3000 to 6000 CFM complete all as specified and directed by Engr-in-Charge.
S&F in replacement of exhaust fan motor size 18" (450 mm sweep)copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Water pump, 18/20 watt , 230 Volts, 50 Hz, SP with discharge head of 1.87 m for desert cooler of any capacity complete all as specified and directed by Engr-in-Charge.
M&L for preparing the surfaces by scrapping out the old paint and painting with two coat of painting of synthetic enamel paint (nerolac) inside & outside surface and applying two coats of rubber seal paint inside water tank to desert cooler capacity upto 5000 cum/hr by spray painting including rewriting MES/SM NO. complete all as specified and directed by Engr-in-Charge.
M&L for Replacement of complete rusted body of voltage stabilizer including U/S transformer , U/S buck & boost relay , U/S electronic control PCB , U/S timer circuit and trigger transformer for automatic opration single phase naturally air cooled indoor type and desinged for input variation b/t 170 v to 280 v with output voltage stabilized at 230 v with accuracy of + 2.5 % and of capacity 4 / 5 KVA complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MS stand factory made suitable for condensing unit of split type AC duly powder coated complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of water cooler electric driven (single phase), having approx storage capacity of 150 litre and nominal cooling capacity of 60 Litres per hour complete all as specified and directed by Engr-in-Charge.
ANAND ENTERPRISES (BID ID -3078351)
M/S Delhi Engineering Co. (BID ID -3073617)
Deepak Electricals (BID ID -3071562)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .