| 1 | L1₹26.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest and Reasonable | |
| 2 | L2₹29.9 L+₹2.3 L (8.24%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹30.0 L+₹2.4 L (8.52%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹33.1 L+₹5.4 L (19.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹33.6 L+₹6.0 L (21.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SRINAGAR
GE AF SRINAGAR AF STN SRINAGAR 190007
DAY TO DAY E/M MAINTENANCE AT SMQ AREA AT AF STN SRINAGAR
2023_MES_600241_1
GE(AF)SGR-47 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AF SRINAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) SRINAGAR
₹60,000
Yes
21 Aug 2023
2 Jun 2023
24 Jun 2023
2 Jun 2023
23 Jun 2023
16 Jun 2023
Amount
Repairing of unserviceable light point, Fan point, socket point 5A / 15A, switches, sockets or regulator, light fixtures any type any type MCBs, replacement of connected wire from ceiling rose to fitting etc in day to day / door to door maintenance and making it serviceable in all respect with provision of adhesive tape and screws & washers etc. Work shall also include to check & removal of breakages in service connection / sub main of houses as and when directed. All items such as switch / socket / switch socket combination / light fitting / regulator / MCBs, connection wire etc required to be replaced for this job will be measured and paid under BOQ Item No 2 to 42 as supply only
Note : (a) Contractors representative / electrician will report to JE E/M / Engr-in-charge daily at forenoon and afternoon to collect routine / urgent works related to internal electric supply till completion of contract. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job including every type of requisite T&P items to his trades man. All routine / urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M within 24hrs. In case of any delay in attending the complaint the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(b) The penalty shall be applicable to the contractor if the delay is noticed by the EIC more than 12 hrs after handing over works of urgent nature to the contractor. The Engr-In-Charge / JE E/M shall handover the slip containing specification of work to the contractor. The contractor shall attend the job immediately and report to Engr-In-Charge within 12hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12 hrs then the facts shall be brought to the notice of the GE / Engr-in-charge and the period for the working to the complaint shall be decided by the GE / EIC.
If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50.00 (Rs fifty only) per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW –2249 and shall be treated as interim condition of the contract and shall enforceable as and delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regard shall be final and binding.
(c) One Complaints slip to be treated as One Complaint irrespective of No. of Repairs mentioned in the same.
(d) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours ( 0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs ) Other than the Regular complaints during working Hrs ( 0900 Hrs to 1700 Hrs )
(e) Procurement of Security gate passes of the Electrician , will be sole responsibility of the Contractor
(f) If the work is repeated due to poor workmanship, contractor will be liable to repair the same without any extra expenditure to the govt.
Supply only Switch piano flush type SP, one way 5 Amps 230 Volt.
Supply only Switch piano flush type SP, one way 15 Amps, 230 Volt.
Supply only Switch socket combination 2 in1, 5 Amps, flush type, 230 Volt.
Supply only Switch socket combination 2 in1, 5 Amps / 15 Amps, flush type, 230 Volt.
Supply only Socket outlet 2 in 1, 5 pin, 5 Amps
Supply only Socket outlet, 2-in-1, 5 pin, 5 and 15 Amps flush
Supply only Switch piano flush type SP, two way 5 Amps 230 Volt.
Supply only Ceiling rose, surface type, 3 terminals.
Supply only Fan electronic dimmers 230 V flush type.
Supply only Angle lamp holder Polycarbonate with back plate.
Supply only Bell push 230 volts, AC
Supply only Call bell ding-dong 230 volts.
Supply only Switch modular type, 1 module, 6 Amps one way.
Supply only Switch modular type, 1 module, 16 Amps one way.
Supply only Socket outlet modular type, 2 module, 3 pin, 6 Amps.
Supply only Socket outlet, modular type, 2 module, 2-in-1, 6 / 16 Amps combined.
Supply only Two way switch modular type, 1 module, 6 Amps.
Supply only Bell push with indicator modular type, 1 module, 6A.
Supply only Fan regulator modular type, 2 module, step type,120 watts.
Supply only MCB Single Pole, 230 Volt, B-Series, Raiting 6 to 32 Amps.
Supply only MCB Single Pole and Neutral , 230 Volt, B-Series, Rating 40 A.
Supply only MCB Single Pole and Neutral, 230 Volt, B-Series, Rating 63A.
Supply only MCB Three Pole and Neutral, 230 Volt, Rating 63 A.
Supply only LED tube light fitting 20 W Batten LED (Warm white / white), Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt.
Supply only LED tube light fitting 10 W Batten LED (Warm white / white), Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt.
Supply only LED 10 watt Bulk Head Light energy saving with IP65 with opal diffuser, pressure die cast aluminium housing.
Supply only Driver for 36 watt LED 600 x 600 Panel light.
Supply only Fan Capacitor 2.5 / 3.15 mfd AC, 230 volt.
Supply only Modular plate 1 module
Supply only Modular plate 2 module
Supply only Modular plate 3 module
Supply only Modular plate 4 module
Supply only Modular plate 6 module
Supply only Modular plate 8 module
Supply only PVC flexible cable twisted two core wire of size 14/76 complete
Supply only 0.50 watt LED lamp retrofit Green / Red colour.
Supply only LED Bulb capacity 10 Watt Warn white.
Supply only LED 06 Watt Recess Mounting, light fitting round / squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt including electronic driver.
Supply only LED 12 Watt Recess Mounting, light fitting round / squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt including electronic driver.
Supply only LED 15 Watt Recess Mounting, light fitting round / squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt including electronic driver.
Supply only LED 15 Watt Surface Mounting light fitting round / squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lum / watt including electronic driver.
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6/10 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed.
Taking down Old/ Unserviceable MCCB/MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including pressed steel sunken box thickness not less than 1.8 mm with 3 mm thick laminated cover for mounting of piano / flush type switches, switch sockets, fan regulator etc, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate, complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
All as per Item No.46 above but for one light point control by two nos, two way switches on independent Board.
All as per Item No.46 above but for 3 pin 5 Amp Socket outlets point controlled by one switch on Same board.
All as per Item No.46 above but for 3 pin 5 Amp Socket outlets point controlled by one switch on Independent board.
All as per item No 46 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
Material & Labour for concealed type point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25 mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for modular type switch with cover plate & frame, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green)
All as per Item No.51 above but for one light point control by two nos, two way switches on independent Board.
All as per Item No. 51 above but for 3 pin 5 Amp Socket outlets point controlled by one switch on Same board.
All as per Item No. 51 above but for 3 pin 5 Amp Socket outlets point controlled by one switch on Independent board.
All as per item No 51 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
S&F modular one way switch 6 Amp 240 volts suitable for one module complete all as specified and directed.
S&F modular two way switch 6 Amp 240 volts suitable for one module complete all as specified and directed.
S&F modular one way switch 16 Amp 240 volts suitable for one module complete all as specified and directed.
S&F modular 6 Amp socket suitable for two module 240 volts complete all as specified and directed.
S&F modular 16 Amp socket suitable for two module 240 volts complete all as specified and directed.
S&F modular step type fan regulator suitable for 120 watt 250 volts complete all as specified and directed.
S&F piano type one way switch 6 Amp 240 volts suitable complete all as specified and directed.
S&F piano type two way switch 6 Amp 240 volts suitable complete all as specified and directed.
S&F piano type one way switch 16 Amp 240 volts suitable complete all as specified and directed.
S&F piano type 6 Amp socket suitable for 240 volts complete all as specified and directed.
S&F piano type 16 Amp suitable for 240 volts complete all as specified and directed.
S&F piano type step type fan regulator suitable for 120 watt 250 volts complete all as specified and directed.
S&F ceiling rose with three terminal as per relevant IS complete all as specified and directed.
M&L for submain wiring with two run of single core multistranded copper conductor cable, of size 10.0 sqmm PVC insulated, unsheathed, drawing through existing surface / recessed steel / PVC conduit of any type and size and including one run single core multistranded copper conductor cable, of size 10.0 sqmm PVC insulated, unsheathed as earth wire, complete. Note:- 2 Runs of main cable and one run earth wire will be measured as one unit for payment purose.
M&L for submain wiring with two run of single core multistranded copper conductor cable, of size 6.0 sqmm PVC insulated, unsheathed, drawing through existing surface / recessed steel / PVC conduit of any type and size and including one run single core multistranded copper conductor cable, of size 6.0 sqmm PVC insulated, unsheathed as earth wire, complete. Note:- 2 Runs of main cable and one run earth wire will be measured as one unit for payment purose.
M&L for submain wiring with two run of single core multistranded copper conductor cable, of size 4.0 sqmm PVC insulated, unsheathed, drawing through existing surface / recessed steel / PVC conduit of any type and size and including one run single core multistranded copper conductor cable, of size 4.0 sqmm PVC insulated, unsheathed as earth wire, complete. Note:- 2 Runs of main cable and one run earth wire will be measured as one unit for payment purose.
S&F Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification (Note-MCBs will be measured separately.).
S&F Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification (Note-MCBs will be measured separately.)
S&F Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification (Note-MCBs will be measured separately.)
S&F Sheet metal enclousers ,TPN Distribution board 4 way, double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification (Note-MCBs will be measured separately.)
S&F VTPN, MCCB DB Double Door, 4 way double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, including 01 No Incommer MCCB 63 Amp, 16 kA complete all as specified and directed. (Note-MCBs will be measured separately.)
S&F MCB Single Pole, 230 Volt, B-Series, Raiting 6 to 32 Amps complete all as specified and directed by Engr-in-charge.
S&F MCB Single Pole and Neutral , 230 Volt, B-Series, Rating 40 A as Incoming MCB complete all as specified and directed by Engr-in-charge.
S&F MCB Single Pole and Neutral , 230 Volt, B-Series, Rating 63A as Incoming in MCB complete all as specified and directed by Engr-in-charge.
S&F MCB Three Pole and Neutral , 415 Volt, Rating 63A as Incoming MCB complete all as specified and directed by Engr-in-charge.
S&F MCB Three Pole and neutral capacity 100 Amp as incoming MCB complete all as specified and directed by Engr-in-charge.
M & L for renewal Earthing complete with galvanised steel earth plate electrode of size 600x600x6 thick as earth electrode burried directly in ground earth plate not less than 2.25m deep below normal groung level with top edge of earth plate not less than 1.5 m below ground level connected to and including galvnised steel earth lead wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed inculding providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board / panal , watering pipe 20mm dia with mesh and funnel at top , earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of characoal dust and salt all around the earth plate , earth work in any type of soil, remaning surplus excavated material all as required at site and specified in EP no 3 of SSR part I 1991 or directed by Engineer-in-Charge.
Note : Earth strip and protection pipe upto 7.5m is included in the unit rate of this item. Contractor shall quote his rate accordingly.
Supply and Laying or Fixing or passing through pipe 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 2 core 6 sqmm nomial cross section in service connection including taking down of old u/s service connection from pole to DB complete all as directed by Engr-in-charge.
Supply and fix in repair GI tubing light grade 25 mm dia fixed to wall / in trenches / in duct / in culvert / road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles all as specified and directed.
Supply and fix in repair building security light LED 25 W, lumen not less than 100lmn/watt with driver with rated voltage 240 V, 50Hz, including mounting on existing bracket complete all as specified and directed.
Supply and fix in repair LED decorative wall light fixture made up of polycarbonate and including LED 15 W Lamp and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one. Make - Havells (City 3) Cat No LHDL06160099 or equivalent make mention in Appx A.
Supply and fix in repair decorative wall mounting light fitting, SS finish fixture with opal glass diffuser including 12 W retrofit LED bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one. Make - Havells (Venza) Cat No LHJCO2108499 or equivalent make mention in Appx A.
Supply and fix in repair decorative wall light made up of high grade engineering plastic material including retrofit LED Bulb 10 watt and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one. Make - Havells (SANA) Cat No LH0GB1TZW035 or equivalent make mention in Appx A.
Supply and fix in repair decorative wall light fitting, Champagne gold finish fixture with plastic body including 12 Watt retrofit LED Bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one. Make - Havells (STYLO) Cat No LHFOCE1TZ10014 or equivalent make mention in Appx A.
Supply and fix in repair decorative wall light fiiting, fixture made up of polycarbonate, including 12 Watt retrofit LED Bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one. Make - Havells (APPLE) Cat No LHFOFTE1TZ1W012 or equivalent make mention in Appx A.
S & F in replacement Sheet metal enclosure single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 / 32 Amps INCLUDING taking down of old one comlete all as directed by Engr-in-cahrge.
Supply and fixing LED light fitting 1x18 Watt flame proof, CMRI certified recommended for gas / vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. complete all as specified and directed by Engineer-in-Charge.
M/S ABDUL REHMAN WANI
M/s PARVAZ CONSTRUCTION COMPANY
M/S TARIQ AHMAD SHEIKH
M/S BASHIR AND SONS
M/S M.R. Construction
M/S LUCKY BUILDERS
M/S A.R.TANTARY
M/S MAQBOOL BHAT & SONS
M/s GHULAM NABI HAJAM
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .