Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.6 L+₹2.0 L (7.30%)Rejected-AOC | L2 | Rejected-AOC BIDDER NOT LOWEST | |
| 3 | L3₹30.0 L+₹2.4 L (8.72%)Rejected-AOC C 204 NANGLI EXTN NEW DELHI | WEST | DELHI | 110043 | L3 | Rejected-AOC BIDDER NOT LOWEST | |
| 4 | L4₹30.1 L+₹2.5 L (9.11%)Rejected-AOC | L4 | Rejected-AOC BIDDER NOT LOWEST | |
| 5 | L5₹32.6 L+₹5.0 L (18.2%)Rejected-AOC | L5 | Rejected-AOC BIDDER NOT LOWEST |
Tender Value
₹40.5 L
EMD Value
₹80,900
Closing Date
18 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
PERIODICAL SERVICES AND CONNECTED WORKS AT STN WKSP EME MT LINE AND FAFA OFFRS MD ACCN AT CARIAPPA VIHAR IN THE AREA OF AGE BR II UNDER GE WEST DELHI CANTT 10
2020_MES_336549_1
GE/DW-36/2020-21
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹80,900
3 Dec 2020
23 May 2020
20 Jun 2020
23 May 2020
18 Jun 2020
6 Jun 2020
60 days
Amount
M&L for preparation of old decoreated internal wall surface by complete removal of existing treatment by mechanised sander of Berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying two coats of Oil Bound Distemper over a coat of wall care putty to uniform smooth surface not more than 1mm thick over a coat of primer complete all as specified and directed.
(a) Preparing old painted surface Surface shall be prepared by scrapping and removing existing paint with Tru Care Wall Sander : L-01/H-01 (mechanical vacuum mechanism, not less than 1500 RPM, sanding pad of 80 Grit dia 7”- 9”) surface shall be even, free from dust, loose paint etc (b) Apply one coat of wall care putty (i) Waterproof cement based Putty shall be prepared (as per manufacturer's instructions mixed with water) with Asian Paints Trucare Putty mixer (min capacity 2.5 kg putty per minute). Putty shall be provided @ 1Kg (undiluted/powder) per Sqm with Asian Paints Trucare Graco spray Machine (Model: EH 230 DI) or equivalent (DC electric motor of 3.3 KW, flow speed of max 6 ltrs per minutes with a maximum pressure 230 bar, maximum tip size 0.041). After puttied surface shall be allowed 6-8 hrs time to dry the putty surface. (ii) Preparation of puttied wall surface Puttied wall surface shall be prepared by sanding with Asian Paints TruCare wall sander: L-01/H-01 or equivalent (mechanical vacuum mechanism not less than 1500 RPM with sanding pad of 240 Grit or above, dia 7”-9” to make the surface smooth, free from dust etc. (c) Apply one coat of acrylic waterbased interior grade primer @ 0.8 ltr (undiluted)/10Sqm diluted as per manufacturer's instructions with fully automatic airless spray machine of paint application of Asian Paints Trucare Graco (Electric motor min 1 HP with a flow speed of min 1 ltr per minute with a pressure of 3300 PSI). Allow 6-8 hrs to dry the surface. (d) Apply two coats of Oil Bound Distemper ( rich matt finish) with fully automatic airless spray machine of paint application of Asian Paints Trucare Graco or equivalant having an electric motor of min 1 HP with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Time interval between two successive coats shall be minimum one day to let the preceding coat dry properly. Second coat shall be applied in the same way as the first coat.
NOTEs (Applicable to Srl items No. 1:- A. At the time of uploading bids each tenderer shall upload a copy of MOU towards tri-party Agreement (for execution of work with material from any of the said manufacturers through their authorised applicator) between "Tenderer", "Manufacturer" of paint and their "Applicators". Manufacturer shall be any of the Asian Paints/Berger Paints/Goodlass Nerolac Paints. Financial Bids of only those bidders shall be admitted whosoever shall upload a legitimate MOU.
B. (Applicable to Srl items other than covered under Note 1 here-in-before). The necessary steel scaffolding upto eight storeyed wherever required to exevcute the work shall be provided by the contractor with all safety equipments and the cost of providing scaffolding & safety equipments, cleaning of paint stains on floor/window/joinery surfaces shall deemed to be included in the tenderer's quoted rates and nothing extra shall be admissible on this account.
M&L for preparation of old decoreated external wall surface by complete removal of existing treatment with manual scrapping tools and applying two coats of weather proofing exterior acrylic emulsion paint over a coat of wall care putty to uniform smooth surface not more than 1mm thick over a coat of primer complete all as specified and directed.
M&L for preparation of old decoreated external wall surface and applying two coats of weather proofing exterior acrylic emulsion paint over a coat of primer complete all as specified and all as directed .
M&L for preparation of old surface of ceiling and applying one coat coat of Oil bound distemper on ceiling surface with brushes (two horizontal strokes immediately followed by two vertical stroke constitute one coat) complete all as specified and as directed.
M & L for preaparation of old surfaces of walls including cornices/Pillars etc by brooming down and applying one coat of cement based paint complete all as specified and directed.
M & L for preparation of old painted surfaces including removal of pasted papers and filling deppressions of wood and wood based materials of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed .
M&L for preparation of old steel surface of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down cement plaster including racking out joints hacking for key scrubbing down with water etc on walls and ceiling and including removal of demolished material beyound MOD land complete all as specified and directed .
M&L 15 mm thick rendering in CM 1:4 external face of walls finished fair even and smooth without using extra cement complete all as specificed and directed.
All as per ser item No 9 here-in-before but 10 mm thick in CM 1:6 on internal face.
All as per ser item No 9 here-in-before but 5 mm thick in CM 1:3 on ceiling
Taking down cement plaster /duster bed PCC of Column, chajja, Parpapets of roof, facia, drops etc and making good with cemnet plaster 10mm thick in CM 1:3 with PCC 1:2:4 type B1 (average thickness of PCC 25mm) as required, brushing with neat cement slurry @ 3.0 Kg of cement per Sqm including necessary form work and scaffolding upto 7th floor including fixing of wire netting where required to match the existing surface complete all as specified and directed
M&L for preparation of new surfaces (plastered or unplastered) of walls including cornices/pillars etc. by brooming down and applying two coats of Oil Bound Distemper paint over a coat of wall care putty to uniform smooth surface not more than 1mm thick over a coat of primer complete all as specified and directed
M&L for preparation of new surfaces (plastered or unplastered) of walls including cornices/pillars etc. by brooming down and applying two coats of cement base paint over a coat of primer complete all as specified and directed
M&L for preparation of new surfaces of ceiling and applying two coats of Oill bound distemper over a coat of wall care putty to uniform smooth surface not more than 1mm thick over a coat of primer complete all as specified and directed
S&F in repair 100mm dia cast iron water socketed pipe with or without ears with lead joint laid in trenches/floors or fixed to walls complete all as specified and directed.
All as per item No 16 above but 75mm bore.
S&F in repair cast iron bends, elbows, Tee with or without door plate, etc of 100mm dia or diminishing pieces or tapers (larger bore measured) in lead joints complete all as specified and directed.
All as per item No 18 above but 75mm bore.
M&L brick work built in cement mortar 1:6 using sub class 'B' bricks(using old size brick) straight or curved on plan exc 6 mtr mean radius using old size bricks including demolition of brick work built in Cement mortar and all quins arches pillars etc including rubbish off the premises beyond MOD land complete all as specified and directed.
S&F in repair stack clamps 100mm bore out of 25mm by 3mm flat iron and 16mm dia (confim as per sample) round iron stay including bolts and nuts and securing ends of stays to wall or roof with concrete/cement mortar complete all as specifie and directed.
All as per item No 21 above but 75mm bore.
S&F in repair 110mm bore PVC (SWR) pipes single socketed, in any length including mild steel stack clamps fixed in cement concrete 1:2:4 blocks with rubber ring joints fixed to walls complete all as specified and directed.
All as per item No 23 above but 75mm bore.
S&F in repair 110mm bore PVC (SWR) bends with rubber ring joints fixed to walls complete all as specified and directed.
All as per item No 25 above but 75mm bore.
S & F in repair 15 mm bore GI tubing medium grade galvanised with all fittings and fixed to walls, ceiling or laid in fllors complete all as specified and directed.
All as per item No 27 above but 20mm bore.
Cutting and taking out grass shrubs, plants,tree roots from Md Accn bldgs in any position and height and treated with necessary chemical/acid to avoid for this growth and making good the disturbed portion with PCC 1:2:4 type BO including finishing etc and rubbish off the premises beyond MOD land complete all as specified and directed. (Note: The cost of scaffolding required for repair is deemed to be in the quoted rate by the Contractor).
Removal of Vegetation from unapproachable roof of block having plinth area not exc 400 sqm and surrounding walls by cutting shrubs, wild growth/tree not exc 30cm girth and removing complete vegetation growth from walls including taking out roots from roof/brick walls and making good the disturbed surface with PCC 1:2:4 type B-0 or CM 1:3 as directed by Engr-in-charge and rubbish off the premises beyond MOD land complete all as specified and directed.
M&L preparation of old cast iron pipe surfaces of any description and applying one coat of black japan paint, over 10cm in width or girth,not otherwise described complete all as specified and directed.
Note : The work shall be carriedout in multistories bldgs upto 7th storeys. The quoted rates shall deemed to be included for necessary T&P, sacffolding/safety measures etc. The contractor shall quote his rates considering this fact in account and nothing extra shall be paid on this account.
Deduct Credit: for demolished/dismantled material of (-) Rs 39765.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
PRAHLAD NARAIN KOLI
S GOURAV PRAKASH ENTERPRISES
M/s M M BAHL
M/S Blues Developers Pvt. ltd
S.R. Constructions
B. S BUILDERS
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .