Tender Value
₹14.8 L
EMD Value
₹15,000
Closing Date
27 Sept 2023, 2:00 pmClosed
SE EUDC-VI
33/11KV S/S Puraniya Aliganj
For routine testing of power transformer, 33KV Panel 11 KV incoming and outgoing and replacement installation of 33 KV 11 KV outdoor CT PT Unit Repairing of 11 KV and 33 KV Pilfer roof metering cubical including replacement of CT PT testing Natural a
2023_MVVNL_813372_6
04/EUDC-VI/LESA T.G./2023-24
Open Tender
Electrical Works
Fixed-rate
365 days
EUTD-5
As per PQR of Document
2 documents required · 2 mandatory
₹3,540
EE EUDD Mahanagar
₹15,000
4 Oct 2023
20 Sept 2023
28 Sept 2023
20 Sept 2023
27 Sept 2023
20 Sept 2023
Amount
Testing of power T/F at 33/11 KV S/S’s under the area of EUTD-V including following tests:- a) Insulation test. b) Open circuit/Ratio test & sort circuit test. c) Magnetization current test. d) Magnetic Balance test. e) Other test including BDV & neutral and body resistance of T/F. The test should be carried out by bringing testing kit and all required instruments on site by the contractor, making all necessary connection for above tests and insuring healthiness of transformers. Complete testing shall be done.
Testing of 33 KV VCB by primary injection set. Testing of winding temperature indicator, oil temperature indicator, oil level indicator & buchholz relay, by operation of individual alarm/trip circuits of above. Testing of annunciation/indication circuits displaying on panel. The work includes cleaning, adjustment of relay contacts & springs by manual and protection trip command generated by relays through primary injection set and Overhauling, annual maintenance of 33 KV VCB with one year guarantee petty items & consumerable item will be provided by contractor and major item will be provided by department.
Testing for 11 KV incoming/outgoing panels including testing of CT ratio by primary injection set. Testing of relays, and its setting as per requirement. The work includes cleaning of relay contacts and adjustment of springs. Checking and operation of VCB/OCB by remote/local and manual/protection command generated through primary injection set with operation of relays and overhauling, annual maintenance of 11 KV VCB with one year guarantee petty items & consumerable item will be provided by contractor and major item will be provided by department.
Replacement/Installation of 33 KV outdoor CT/PT unit.
Replacement/Installation of 11 KV outdoor CT/PT unit.
Repairing of 11 KV & 33 KV pilfer roof metering cubical including replacement of CT/PT, testing
Neutral and body earth resistance measurement of 33/11 KV Transformer.
Earth resistance measurement.
K MAA ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .