Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹32.3 L+₹3.4 L (11.8%)Rejected-Finance WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹34.7 L+₹5.8 L (20.1%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance Not Being Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Jun 2022, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
CLEANING AND REPAIR OF SEWAGE LINES AND MANHOLES IN DK-I DK-II AND RR COLONY AND PETTY REPAIR AND MISC E/M WORKS INCLUDING DAILY MAINTS COMPLAINTS AT RRRC GREEN MEADOWS CC HUT ARTRAC HUT TRAINING AREA UNDER GE CENTRAL DELHI CANTT-10
2022_MES_523061_1
GE/C-17/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
CLEANING AND REPAIR OF SEWAGE LINES AND MANHOLES IN DK-I DK-II AND RR COLONY AND PETTY REPAIR AND MISC E/M WORKS INCLUDING DAILY MAINTS COMPLAINTS AT RRRC GREEN MEADOWS CC HUT ARTRAC HUT TRAINING AREA UNDER GE CENTRAL DELHI CANTT-10
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹90,000
Yes
14 Jun 2022
10 May 2022
8 Jun 2022
10 May 2022
6 Jun 2022
24 May 2022
10 May 2022 - 24 May 2022
Amount
Taking down Cement plaster on brick walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc omplete all as specified and as directed. Engr-in-Charge .
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for omplete all as specified and as directed. Engr-in-Charge .
Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc omplete all as specified and as directed.Engr-in-Charge .
M&L for cement concrete 1:2:4 type B-I, using 20 mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes complete all as specified and as directed.
M&L for brick work with sub class 'B' brick using old size bricks straight or curved on plan exc 6m mean radius built in CM 1:4 omplete all as specified and as directed.
All As per item no 5 here in before but except bricks
Excavation any type of soil in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in in hard dense soil omplete all as specified and as directed.
All as per item No 07 here-in-before but exc 1.50m and n exc 3.00m in depth.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil omplete all as specified and as directed.
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil complete all as specified and as directed.
M&L PCC 1:4:8 type D2 using 40mm graded stone aggregates as in foundation of manholes omplete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregates as in surfaces channels and drains complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stoped ends etc omplete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates incl packing under and haunching against the sides for 150mm internal dia SGSW pipes after they are laid and tested including demolition of old bed and pipes omplete all as specified and as directed. (thickness of concrete bed 100mm).
All as per ser item No 14 here-in-before but for 200mm internal dia Salt glazed stoneware pipes (thickness of concrete bed 150mm).
Supply and laying, jointing 150mm internal dia of salt glazed stoneware pipes grade 'A' incl testing and laid in trenches to a level on concrete bed complete all as specified.
All as per item No.16 here-in-before but 200mm internal dia of salt glazed stoneware pipes grade 'A' .
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 mixed with water proofing compound finished even and smooth without using extra cement complete all as specified. Note - Water proofing compound shll be measure and paid separatelly.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed. .
Supply only intergral water proofing compound complete all as specified and as directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150/200mm dia pipes omplete all as specified and as directed.
S & F for precast fibre reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mmx80mm omplete all as specified and as directed. Make : M/s Polycrete or equivalent make as approved.
S & F for precast plastic fibre reinforced cement concrete Manhole covers with frame medium duty of overall size 450mmx450mmx50mm factory made (make-polycrete) all as specified and directed by Engineer-in-Charge. Make : M/s Polycrete or equivalent make as approved.
Removal of blockage including Cleaning of EWCs, IWCs, bottle traps, Nahani Traps, Gully traps and Floor traps etc and CI/PVC Pipes all types top to bottom including junctions etc, Cleaning of sewage line upto GT in the area of DK-II,DK I Ring Road Colony , (Md accn and all types of Accn including multistory bldg ).including removal of waste out side MOD Land complete all as specified and as directed.
Cleaning of Manhole of up to depth of 1.2mtr and any size of MH in the area of DK- II, Ring Road Colony ,(Md accn and all types of Accn) and taking out sludge inclosed vehicle and depositing them to notified area by Municipal Corp of Delhi for dumping or out side defence land omplete all as specified and as directed.
Cleaning of Manhole of up to depth exc 1.2 mtr and above of any size of MH in the area of DK-II, DK-I, Ring Road Colony , (Md accn and all types of Accn) omplete all as specified and as directed.
Removal of blockage including Cleaning of Sewage line from GT to Ist Manhole in the area of DK-II, DK-I, Ring Road Colony , (Md accn and all types of Accn) omplete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to 150mm all as specified and as directed.
Removal of blockage including Cleaning of sewage line n.exc 10mtr in length in the area of DK-II, Ring Road Colony (Md accn and all types of Accn). complete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to 200mm all as specified and as directed.
Removal of blockage including Cleaning of Sewage line 0.00mtr to 20.00mtr in length in the area of DK-II, Ring Road Colony (Md accn and all types of Accn) omplete all as specified and as directed. (Note :- This item will be measured if length exceed from 10.00mtr.and cleaning of sewage line daimeter upto 100mm to 200mm all as specified and as directed.
Removal of blockage including Cleaning of Sewage line 0.00mtr to 30.00mtr in length in the area of DK-II, Ring Road COlony (Md accn and all types of Accn) complete all as directed and as specified. Note :- This item will be measured if length exceed from 20.00mtr.and cleaning of sewage line daimeter upto 100mm to 200mm all as specified and as directed.
Removal of blockage including Cleaning of Sewage line 0.00mtr to 50.00mtr and onwards in length in the area of DK-II, Ring Road Colony , (Md accn and all types of Accn) complete all as directed and as specified. (Note :- This item will be measured if length exceed from 30.00mtr.and cleaning of sewage line daimeter upto 100mm to 200mm all as specified and as directed.
Dewatering/desludging of septic tanks, soakage wells etc of any depth, cleaning of all sludge, silt residue of both organic and inorganic nature by manual labour or by mechanical etc and disposal off the same inclosed vehicle out side the defence area in a close area notified by Municipal Corporation of Delhi all as directed by Engr-in-Charge.
Mechanically used water fitting Hydraulic pressure machine and water sucking hydraulic pressure machine jet press for cleaning of sewage line shall be used by the contractor as per direction of Engineer-in-Charge as on required basis for the whole day i.e 8.00 Hrs and shall be completed to the entire satisfaction of GE. (For Dhaula Kuan Part -II ) all as specified and as directed. Note :- Rate quated and deemed to be for the whole day.
All as per item No. 33 above but in the area of DK I
All as per item No. 33 above but in the area of RRColony.
All as per item No. 33 above but in the area of MES Civilian Accn.
Taking down CI/PVC/AC soil pipe from wall, treches of any description including fittings.
S&F in repair for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc including taking out/dismentling of old pipe complete all as specified.
All as per item No. 38 above but bore of pipe in 110 mm.
S&F in repair PVC (SWR) bends any radius bore 75 mm
All as per item No. 39 above but bore of pipe in 110 mm.
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 75mm complete all as specified and directed. Make : NECO (Jayaswal)/HEPCO (Binay Udyog)/Jindal Saw/Hindustan Engineering products.
Demolition of existing sewage line pipe of 150 mm in internal dia complete incl removal of rubbish out side from MOD land complete all as specified and directed.
All as per Sel item No 43 here in before but 200mm internal dia
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 100mm complete all as specified and directed. Make : NECO (Jayaswal)/HEPCO (Binay Udyog)/Jindal Saw/Hindustan Engineering products.
Supply and fix cast iron Bends (sand cast) (any radius), diminishing pieces or tapers soil/waste pipes 75mm in any length (larger bore measured) complete all as specified and directed.
All as per item No.46 above but 100mm dia
S & F for precast fibre reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 900mmx900mmx80mm omplete all as specified and as directed.
M&L for Cement Concrete 1:3:6 type C-2 Using 40mm graded aggregates for bedding layers of laid Complete all as specified (thickness of concrete bed 150mm)
S & F DWCPE (SN8) 180 (OD) /163 (ID) mm dia pipes Snap fit/Push fit Coupler with rubber ring/gasket for joining incl testing and laid and properly jointed laid in trenches to a level on concrete bed Complete all as specified
S & F DWCPE (SN8) 200 (OD) /175 (ID) mm dia pipes Snap fit/Push fit Coupler with rubber ring/gasket for joining incl testing and laid and properly jointed laid in trenches to a level on concrete bed Complete all as specified
Cutting through brick wall in cement mortar for holes and making good disturbed portion in CM (1:3) or cement concrete (1:2:4) type B-1 as required.
S & F in repair 110mm dia PVC bends of any radius with acces door
S & F in repair 110mm dia PVC SWR junction single T equal or unequal with acess door
S & F in repair 110mm dia PVC SWR branch piece double (double Y) equal or unequal with acess door.
S & F in repair 110mm PVC (SWR) vent cowl
M & L 100mm dia PVC floor trap with grating incl jointing to waste pipe fixed in cement conc type B 1 (1:2:4)
S & F in repair grating doom 125mm dia with waste hole of PTMT (min wt 40 gms)
S&F in repair 32mm dia PVC waste pipe for urinal/kitchen sink/WHB including CP waste coupling 32mm dia including taking down old existing pipe complete all as specified and as directed.
Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge at RRRC, Green Meadows, CC Hut, Artract Hut, Training Area.
Attending to complaint of unsv switch ,socket ,fan regulator and making of light / power point in casing caping upto 2 mtr of length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at RRRC, Green Meadows, CC Hut, Artract Hut, Training Area.
Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed. Notes for Item No. 1,2 and 3 (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician and 01 helper at Pratap Chowk Complaint cell from 0900Hrs to 1700 Hrs from Monday to Sunday. Electrician and helper shall report to complaint cell at 0900 hrs daily and get the job card for carry out the work and same will be retrun to concered JE at 1700 hrs as token of completion of job. In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) All ser numbered complaint docket will be provided by contractor and amount of docket included in this. (h) Daily attendance register will be maintained by conserned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Attending to electrical complaint of no light / short circuit in light or power circuit / MCCB tripping or any other emergency nature complaint during night hours (from 09 pm to 05 am). Notes for Item No. 4 (a) fixtures / fittings shall be paid under relevant item against supply only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician at Pratap Chowk Complaint cell from 2100 Hrs to 0500 Hrs from Monday to Sunday to carryout emergent nature of complaint . Electrician shall report to complaint cell at 2100 hrs daily . In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account. Note: whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 4 hours. (g) Daily attendance register will be maintained by converned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor.
Supply only switch piano flush button type single pole one way 6 Amps all as specified.
Supply only switch piano 6 amp SP two way, ISI marked Make:Havells Reo or equivalent in legrand/Schneider.
Supply only socket piano outlet 6 Amp flush button type all as specified Make:- Havells Reo or equivalent in legrand/Schneider/.
Supply only bell push single pole 6 Amps all as specified Make:- Havells Reo or equivalent in legrand/Schneider.
Supply only switch piano flush button type single pole 16 Amps. Make:- Havells Reo or equivalent in legrand/Schneider.
Supply only socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole . Make:- Havells Reo or equivalent in legrand/Schneider.
Supply only Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete. Make : Anchor/ Havells/ cona
Supply only switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells.
Supply only switch Modular type 6 Amps two way 230V AC complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells.
Supply only replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.Make:- Legrand/Schneider/ ABB
Supply only Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells.
Supply only switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells.
Supply only Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge. Make:-IndoAsian, Legrand or Havells.
Supply only Modular five stepped type electronic fan regulator 1/2 module 230V AC complete all as specified and directed by Engineer in charge. Make:- IndoAsian, Legrand or Havells..
Supply only ceiling rose surface PVC type with three terminals.Make:- Havells/Polycab/Anchor.
Supply only Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed. Legrand/Havells Reo/ Anchor
Supply only insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed. Make : Havells / Crompton Greaves/ Anchor
Supply only industrial metal clad plug top, 3 pin, 10amp / 20 amp (ISI marked) as directed.
Supply only industrial metal clad socket 3 pin 10 amp / 20 amp (ISI marked) as directed.
Supply only relacement plug top 16 Amps 3 pin 230- volts Make:- Crabtree/Havells Reo.
Supply only LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed
Supply only LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply only LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. (Make-Wipro / Crompton Greaves / eqivalent in Phillips).
Supply only in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base. Make:- Philips/Wipro/Jaquar
Supply only 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz
Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz,
Supply only MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/Indoasian /Havels.
Supply only MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/ Indoasian/ Havlls.
Supply only MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/Indoasian/ Havells.
Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete. Make:- Legrand/Indoasian/ Havells.
Supply only MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .Make:- Legrand/SEIMENS/ABB.
Supply only MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting .Make:- Legrand/SEIMENS/ABB.
Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 20 Amp complete all as specified and directed.
Supply only PVC Gang box surface type heavy duty suitable for single switch 5 Amps (ISI Marked) . Make- Legrand /Havells/Crabtree/Polycab.
Supply only Gang box surface type heavy duty suitasble for 15 Amps switch and socket (ISI Marked)
Supply only replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
Supply only replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :- Make :-As per sample.
(a) Sheet 4" x 4" single cutting suitable for one piano switch
(b) Sheet 4" x 4" two cuttings suitable for two piano switches
(c) Sheet 4" x 7" three cuttings suitable for three piano switches
(d) Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
(e) Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
(f) Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.Make:as per sample
supply only hole fastner madeup of MS 4" long with complete nut bolt all as specified.Make:as per sample
Supply only heating element of 2 KW any type with nut bolt washer complete all as directed. Make-THEETA/BAJAJ/USHA
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed. Make-THEETA/BAJAJ/USHA
Supply only non return valve 15mm dia (ISI Marked) for geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
Supply only for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
Supply only thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed. Make - Havells / Jaquar / Bajaj.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm with approved colour code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code completed all as specified.Make:-Finolex ,Polycab, RR Kable
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 4 sqmm with approved coloured code completed all as specified. Make:- Finolex ,Polycab, RR Kable
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 6 sqmm with approved coloured code completed all as specified. Make:- Finolex ,Polycab, RR Kable
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 10 sqmm with approved coloured code completed all as specified. Make:- Finolex ,Polycab, RR Kable
Supply only replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge
Taking down sub main wiring off sizes etc complete all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 4.00 sqmm (Main Cable and neutral) and one run of 4.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 6.00 sqmm (Main Cable and neutral) and one run of 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of 10 sqmm (Main Cable and neutral) and one run of 10 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed.
Schedule of Credit
M/S Sunil Steel Works
imran construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .