Tender Value
₹38.2 L
EMD Value
₹76,400
Closing Date
3 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
POWER
12 conditions · 1 needing a document upload
The contractor should have valid Electrical Contractor License issued by Govt. and submit along with tender document. If valid Electrical Contractor License is not submitted along with tender document, then offer will be summarily rejected. The OEM or his authorized dealer will be exempted from license, in case of authorized dealer; tender specific authorization certificate form OEM must be attached along with tender documents. Standard technical Criteria, Standard Financial Criteria and other special terms & conditions of technical specification will be remains same.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
5 conditions · 2 needing a document upload
The tenderer shall submit all relevant documents as detailed in para 14 & 18.10 of Tender Form (Second Sheet) of Part I of GCC work-2022.
The tenderer shall submit copy regarding status of firm i.e. sole proprietorship, partnership, Company, Society/Trust etc. and also submit a power of attorney and other relevant documents as detailed in Para no. 15 of Tender Form (Second Sheet) of Part I of attached GCC-2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should quote only the above/below percentage on estimated value, in the space provided at web portal for the purpose & nowhere else. Financial & Technical conditions quoted at any place other than prescribed space shall not be entertained while evaluating the offer.
Tenderer are required to go through the documents attached along with the tender and submit their bids accordingly.
Electrical work in connection with - Up-gradation of infrastructure and Augmentation of maintenance facilities in C&W Workshop Bikaner and Provision of construction of new weigh bridge ( Capacity 100 MT) in store depot and Construction of double storey space for storage of non-ferrous material including staff room, parking and toilets etc.
04-Ele-WS-BKN-2025-26R~NWR
04-Ele-WS-BKN-2025-26R
Open
Works - General
10 Months
Bikaner, Rajasthan
₹0
₹76,400
11 Aug 2026
11 Aug 2026
20 Aug 2026
186 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 33,82,646.22 | ||
| — | 210.00 | — | — | ||
| Recessed/Surface conduit wiring system-Supply of material and wiring of LP/TP/FP/Exhaust fan/ Bell point with single core multistrend copper conductor size 1.5 Sq.mm with earth wire in PVC conduit pipe with 5/6 Amp modular type switch/ceiling rose/batten holder etc. | — | — | — | 82,236 | |
| — | 30.00 | — | — | ||
| Supply of material & fixing of flush metal box of 2-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 2,016 | |
| — | 30.00 | — | — | ||
| Supply of material & fixing of plate Inner & Outer 2-Module used for concealed modular wiring. | — | — | — | 4,032 | |
| — | 10.00 | — | — | ||
| Supply of material & fixing of flush metal box of 4-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 1,228.5 | |
| — | 10.00 | — | — | ||
| Supply of material & fixing of plate Inner & Outer 4-Module used for concealed modular wiring. | — | — | — | 2,299.5 | |
| — | 32.00 | — | — | ||
| Supply of material & fixing of flush metal box of 6-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 6,081.6 | |
| — | 32.00 | — | — | ||
| Supply of material & fixing of plate Inner & Outer 6-Module used for concealed modular wiring | — | — | — | 11,188.8 | |
| — | 40.00 | — | — | ||
| Supply of material & fixing of flush metal box of 12-Module with connection used for concealed modular flush metal box wiring | — | — | — | 13,104 | |
| — | 40.00 | — | — | ||
| Supply of material & fixing of plate Inner & Outer 12-Module used for concealed modular wiring. | — | — | — | 13,398 | |
| — | 40.00 | — | — | ||
| Supply & fixing of blank plates (1- Module) used for concealed modular wiring. | — | — | — | 1,134 | |
| — | 30.00 | — | — | ||
| Supply of material & fixing of 6/16 Amp. 6-pin/3pin combined shuttered socket with switch (2-Module) with switch used for concealed modular wiring. | — | — | — | 7,749 | |
| — | 80.00 | — | — | ||
| Supply of material & fixing of 6 Amp. 5-pin/3pin socket with switch (2-Module) used for concealed modular wiring. | — | — | — | 13,776 | |
| — | 30.00 | — | — | ||
| Supply, fixing & connection of moduler type Ceiling rose 3plate 6 Amp., 240 Volt, ISI marked | — | — | — | 1,575 | |
| — | 220.00 | — | — | ||
| Supply, fixing & connection of Ceiling rose 3plate 6 Amp., 240 Volt, ISI marked, As per specification. | — | — | — | 5,931.2 | |
| — | 60.00 | — | — | ||
| Supply & fixing of 5/6 amp. 5 pin socket with switch on existing MS board.(Non modular type) | — | — | — | 2,898 | |
| — | 20.00 | — | — | ||
| Supply & fixing of 15 amp. 6 pin socket with switch on existing MS board. .(Non modular type) | — | — | — | 3,280.4 | |
| — | 30.00 | — | — | ||
| Supply and fixing of MS board 300x200x50mm manufactured by 1.6mm MS sheet duly finished with two coats of red oxide , earth terminal, 3mm sunmica sheet, zinc plated/ brass screw, cup washer etc in recessed | — | — | — | 7,380.6 | |
| — | 40.00 | — | — | ||
| Supply and fixing of MS board 175x100x50mm manufactured by 1.6mm MS sheet duly finished with two coats of red oxide , earth terminal, 3mm sunmica sheet, zinc plated/ brass screw, cup washer etc in recessed | — | — | — | 3,594.8 | |
| — | 200.00 | — | — | ||
| Supply and fixing of MS board 100 X100 X50 manufactured by 1.6mm MS sheet duly finished with two coats of red oxide , earth terminal, 3mm sunmica sheet, zinc plated/ brass screw, cup washer etc in recessed | — | — | — | 12,356 | |
| — | 60.00 | — | — | ||
| Supply, installation, testing & commissioning of Piano type one way switch 6 Amp. ISI marked. As per specification. | — | — | — | 1,078.8 | |
| — | 50.00 | — | — | ||
| Supply & fixing of 32 A 5 Pin Panel Mounted Industrial Plug & Socket, with MCB 3 Phase AC, 230/415 Volt. with enclosure. | — | — | — | 2,41,978 | |
| — | 1500.00 | — | — | ||
| Supply and fixing of PVC conduit/casing capping (as per instruction of site supervisor) and its accessories, size 25 mm, thickness 1.6 mm As per IS 9537 part I. | — | — | — | 60,675 | |
| — | 3000.00 | — | — | ||
| Supplying and drawing 4.0 sq. mm PVC insulated multi-strand copper conductor cable as sub-main and 1.5 sq. mm PVC insulated multi- strand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing capping. Wire should be of reputed make and as per tech. spec. | — | — | — | 1,24,710 | |
| — | 700.00 | — | — | ||
| Supplying and drawing 6.0 sq. mm PVC insulated multistrand copper conductor cable as submain and 1.5 sq. mm PVC insulated multistrand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing caping. Wire should be of reputed make and as per tech. spec. | — | — | — | 40,285 | |
| — | 2500.00 | — | — | ||
| Supplying and drawing 2.5 sq. mm PVC insulated multistrand copper conductor cable as submain and 1.5 sq. mm PVC insulated multistrand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing caping. Wire should be of reputed make and as per tech. spec. | — | — | — | 76,125 | |
| — | 250.00 | — | — | ||
| Fixing of LED four feet fitting complete with tube /LED Panel light 36 Watt in 2feet x 2feet | — | — | — | 7,865 | |
| — | 200.00 | — | — | ||
| Fixing and commissioning of ceiling fan/ wall fan/ exhaust fan with nut bolt ensuring all safety aspects. Contractor is responsible for falling of fan within a period of 12 month. | — | — | — | 5,040 | |
| — | 10.00 | — | — | ||
| Supply and fixing of junction box size 390/388x 305/304 x170mm comprising of SMP/ FRP material with rubber gasket, padlock arrangement, zinc passivated earth bolt, etc. Make Sintex or similar with 4 no. aluminum busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole/ wall as per requirement. All the material should be of good quality. | — | — | — | 18,971.3 | |
| — | 12.00 | — | — | ||
| Supply and fixing of Double Door MCB DB SP 12 way (10+2 module), neutral and earth link, with one no DP MCB 40 amp, one no DP RCCB 40 amp 30 mA and eight no SP MCB 32/25/16/10/6 amp. 'C' series. Breaking capacity not less than 10 kA. MCB, RCCB and DB should be as per tech spec. and of same make. | — | — | — | 66,565.8 | |
| — | 1.00 | — | — | ||
| Supply, fixing and commissioning of Electronic bell, operating voltage 230 V AC. Bell should be of reputed make. | — | — | — | 223.61 | |
| — | 1.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of LT panel made by 2 mm CRCA sheet with 1 no. Incomer 250A MCCB and Outgoing - 2 no. 4 pole MCCB 125 amps.,2 nos. 4 pole MCCB 63 amps. and 2 nos. 4 pole MCCB 40 amps. with meter & indication LED, copper bus bar etc as per spec. | — | — | — | 1,09,318.17 | |
| — | 1000.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec. ( trench work may be on kuchha/ pucca land and all type of soil as per site requirement and without protective layer of brick ) Surface of trench shall be made good in all respect and satisfaction of site engineer. | — | — | — | 37,000 | |
| — | 400.00 | — | — | ||
| Supply of HDPE pipe, 160 mm dia, conforming to IS 4984: 2016 as per site requirement. | — | — | — | 2,25,812 | |
| — | 400.00 | — | — | ||
| Laying of Spun/MS/GI/DWC / HDPE pipe 100mm to 200 mm by drilling of Horizontal bore by machine in Railway yard/ below track /Road. | — | — | — | 4,67,380 | |
| — | 500.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, wall thickness minimum 3 mm, under the road. | — | — | — | 42,050 | |
| — | 500.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 75/80mm dia, wall thickness minimum 3 mm, under the road. The work involves laying of HDPE pipe. | — | — | — | 5,605 | |
| — | 2000.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness minimum 3 mm, under the road. | — | — | — | 1,12,140 | |
| — | 2000.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness minimum 3 mm, under the road. The work involves laying of HDPE pipe. | — | — | — | 15,700 | |
| — | 25.00 | — | — | ||
| Supply of unit maintenance free earth material as per RDSO Specs. No RDSO/PE/SPEC/PS/0/0109 (REV.0 ) 2008 or Latest | — | — | — | 2,26,504.5 | |
| — | 25.00 | — | — | ||
| Installation of unit maintenance free earth as per RDSO Specs. No RDSO/PE/ SPEC/PS/0/0109 ( REV.0) 2008 or Latest | — | — | — | 95,413.5 | |
| — | 10.00 | — | — | ||
| Supply and fixing of occupancy sensor | — | — | — | 20,558.4 | |
| — | 3000.00 | — | — | ||
| Supply of 3 core 1.5 sqmm XLPE multistrand FR Flexible cable copper cable unarmoured as per IS : 7098(Part 1)(Q2) | — | — | — | 1,10,250 | |
| — | 1500.00 | — | — | ||
| Supply of 4 core 2.5 sqmm multicore FR Flexible copper cable as per IS : 694(Q3) | — | — | — | 1,57,500 | |
| — | 8.00 | — | — | ||
| Supply and fixing of TPN MCCB double door DB12+2 way with 4P100A (25 kA)MCCB- 1 no., 2P63A, 100 mA RCCB-3 nos. and2P 25A 'C' series10 kA MCB-18nos. MCCB, MCB,RCCB and DB should be as per tech spec. and of same make. | — | — | — | 2,35,380.32 | |
| — | 6.00 | — | — | ||
| — | 100.00 | — | — | ||
| — | 8.00 | — | — | ||
| — | 32.00 | — | — | ||
| — | — | — | 8,731.2 | ||
| — | 32.00 | — | — | ||
| — | — | — | 3,461.12 | ||
| — | 60.00 | — | — | ||
| — | — | — | 4,056 | ||
| — | 30.00 | — | — | ||
| — | — | — | 76,616.4 | ||
| — | 3000.00 | — | — | ||
| — | — | — | 69,360 | ||
| — | 220.00 | — | — | ||
| — | — | — | 24,950.2 | ||
| — | 210.00 | — | — | ||
| Supply, fixing and commissioning of street light/Flood light fitting accessories e.g. GI pipe of bore 25 mm, clamps, nuts, bolts, cable etc as per instruction of site engineer | — | — | — | 32,428.2 | |
| — | 40.00 | — | — | ||
| Supply and fixing of MCB DP 32 amp with box . Breaking capacity not less than 10 KA. | — | — | — | 57,512.8 | |
| — | 220.00 | — | — | ||
| Supply and providing of cable marker - for underground cable (Other than PLTC) The cable marker shall be made of MS sheet 1.5 mm thick size 150 x 200 mm welded with 12 mm dia MS rod 01.50 Mtrs long. The lower end of rod should be turned in hooks shape and attached with the cable at the laying. | — | — | — | 34,999.8 | |
| — | 200.00 | — | — | ||
| SITC of pole junction box of size 250x 250 x100 mm made by powder coated ms sheet of 1.6mm including 4 pole connector and SP mcb 6 Amp. | — | — | — | 2,63,976 | |
| — | — | — | 4,37,454.38 | ||
| — | 130.00 | — | — | ||
| Recessed/Surface conduit wiring system-Supply of material and wiring of LP/TP/FP/Exhaust fan/ Bell point with single core multi strend copper conductor size 1.5 Sq.mm with earth wire in PVC conduit pipe with 5/6 Amp modular type switch/ceiling rose/batten holder etc. | — | — | — | 50,908 | |
| — | 40.00 | — | — | ||
| Supply of material & fixing of flush metal box of 2-Module with connection used for concealed modular flush metal box wiring. | — | — | — | 2,688 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCwithcorrectionslip1to10.pdf GCC with correction slip 1 to 10
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
AnnexureVandVA_1_1.pdf
ATTACHMENT
TechnicalSpec..pdf
ATTACHMENT
GCCwithcorrectionslip1to10.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].