| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹69,829.41Accepted-AOC AT MOHAN NAGAR PO DAKRA PS KHALARI DISTT RANCHI JHARKHAND 829201 | CHATRA | JHARKHAND | 829201 | L-1 | Accepted-AOC As per Recommendation of TC and Approval of Competent Authority | |
| 2 | L-2₹70,276.63+₹447.22 (0.64%)Rejected-Finance AT BACHRA P O BACHRA P S PIPARWAR BACHRA 829201 | BACHRA | CHATRA | JHARKHAND | 829201 | L-2 | Rejected-Finance AS per recommendation of TC and approval of Competent Authority | |
| 3 | L-3₹72,193.26+₹2,363.85 (3.39%)Rejected-Finance AT POST RAY DIST RANCHI 829209 | RAY | RANCHI | JHARKHAND | 829209 | L-3 | Rejected-Finance AS per recommendation of TC and approval of Competent Authority |
Tender Value
₹63,888
Closing Date
3 Apr 2023, 5:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area, Bachra. 829201
Work of Fresh Electrical Wiring of Qtr.No. MQ-274, Bishujhappa Colony, Bachra under Magadh Sanghmitra Area
2023_CCL_276442_1
GM(MS)/SO(EnM)/e-NIT/22-23/106
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Office of the general manager M-S Area, Bachra
Please Refer NIT
4 documents required · 4 mandatory
26 Oct 2023
24 Mar 2023
4 Apr 2023
24 Mar 2023
3 Apr 2023
24 Mar 2023
24 Mar 2023 - 31 Mar 2023
Amount
Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. Mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. Mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit including dismantling as required (Group A)
Supplying and fixing of metal box of 180mmX100mmX60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 15/16 amps socket outlet and 15/16 amps piano type switch connection , painting etc. as required.
Wiring for light/power plug with 2x4sqmm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1No. 4 sqmmFR PVC insulated copper conductor single core for loop earthing as required.
(1)Supplying and fixing of 5amps to 32amps rating, 240/415volts "c" curve, miniature breaker suitable for induction load of following poles in the existing MCB DB complete with connections testing and commissioning etc.as required. (1) single pole.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply of 2+2 way, SPN single door, MCB distribution box.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 60 mm
Supplying and fixing two modular stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and drawing of 2x6sq.mm of FR PVC insulated copper conductor single core in the existing surface recessed steel/PVC conduit as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required Group A
Total impact of GST for the purpose of CTC
M/S ASHOK ENTERPRISES
M/S DEVNANDAN SHARMA
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_286184.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .