Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹10.0 L+₹1.8 L (22.3%)Rejected-Finance G 86 DATA RAM SECTOR 18 ROHINI NEW DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹12.9 L+₹4.8 L (58.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹15.7 L+₹7.5 L (92.1%)Rejected-Finance BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L4 | Rejected-Finance Other than lowest tender | |
| 5 | L5₹16.1 L+₹8.0 L (97.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tender |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
22 Oct 2020, 6:00 pmClosed
GE (N) DELHI CANTT -10
GE (N) DELHI CANTT -10
REPAIR MAINT OF INTERNAL ELECTRICATION WORK INCL REPLACEMENT OF UNSV VARIOUS TYPE OF LIGHT FITTINGS FIXTURES SUBMAIN WIRING DISTRIBUTION BOARDS MCCBs MCBs ETC OF JCOs ORs MD ACCN OUTSIDE CENTRAL ORDNANCE DEPOT AREA UNDER GE NORTH DELHI CANTT
2020_MES_380986_1
GE/NORTH-52/2020-21
Open Tender
Civil Works
Works
180 days
GE (N) DELHI CANTT -10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT -10
₹30,000
Yes
7 Dec 2020
25 Sept 2020
24 Oct 2020
25 Sept 2020
22 Oct 2020
9 Oct 2020
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps (Make of wiring cable & PVC conduit - Finolex/Plaza/Polycab/Anchor)
All as per srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 amps
All as per srl item No 02 here-in-before but one 3 pin, 06 amps socket outlet point on independent board controlled by one, one way 06 amps switch.
All as per srl item No 02 here-in-before but one 3 pin, 06 amps socket outlet point on same board controlled by one, one way 06 amps switch.
All as per Serial Item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F switch piano flush type, 06 Amps, single pole, one way, 250 volts complete
S&F bell push, flush type, 06 Amps, 250 volts with switch frame complete
S&F switch piano flush type, 16 Amps, single pole, one way, 250 volts with switch frame complete
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 250 volts with socket frame complete
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 250 volts with socket frame complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, socket size, humfree, AC, 230 volts, 100 watts complete
S&F ceiling rose, 6 Amps, 250 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 7W LED bulb (Make of Bulb : Wipro/Havells/Philips) complete
S&F in repair 5W LED T5 TL fitting (1 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete,
S&F in repair 10/12W LED T5 TL fitting (2 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flexible copper conductor cable of suitable size complete
S&F in repair on wall / ceiling LED batten lighting fixture 20 watts LED 5700K (4'), with extruded aluminium heat sink, integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
S&F in repair 12 Watt round LED panel recess mounting downlight in 4000K with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 145mm mm dia hight max 35mm recess luuminaries all as specified and directed.
S&F in repair ultra modern recess mounting 36 Watts, 5700K, 2x2 LED flat panel complete with integrated electronic driver, soft-light and glare free symmetrical illumination, suitable for POP ceilings high brightness SMD LEDs, etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
S&F in repair energy saving security light fitting of 45 watts LED environmental friendly pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 25 mm bore light grade GI tube mounting bracket of 1.5 meter in length, bend to shape as directed and fixed to wall by means of 02 nos. of 25 x 5 mm flat iron clamps, nuts, bolts and washers etc complete
S&F Ventilating fan wall mounted type of 250 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed
M&L for sub main wiring with 10 Sqmm nominal cross sectional area, four single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 32/40 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete
M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete
S&F in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete
S&F in repair sheet metal enclosure distribution board, single pole and neutral, double door AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete
Supply and fixing in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:- (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No. (b) MCB, SP, AC, 240 volts of 06 to 32 Amps, "C" curve, 10 KA breaking capacity - 12 Nos.
S&F in repair MCB, AC, 240 volts,"C" curve, 10 KA breaking capacity and making connections by using copper lugs complete of following rating
MCB SP 10 to 40 Amps
MCB DP 40 Amps
MCB DP 63 Amps
S&F in repair MCCB 4 pole, AC, 415 Volts incl connection complete of following rating/ capacity
(a) 63 Amps, 16 KA
(b) 100 Amps, 16 KA
(c) 125 Amps, 16 KA
(d) 200 Amps, 36 KA
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, angle iron frame for pit cover including testing on completion complete
S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete
Schdule of Credit - 53590.00
NEETU TRADERS (INDIA)
Surjit and Sons
m/s VK construction company
JM enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .