Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.6 LAccepted-AOC DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹56.2 L+₹61,800.61 (1.11%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹64.4 L+₹8.8 L (15.8%)Rejected-Finance | L3 | Rejected-Finance NOT L1 |
| Sl No | Description | Qty | Unit | KDR CONSTRUCTION L1 | Srisrinivasaenterprises L2 | VACON INFRASTRUCTURES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc. and nexc 10 sqm on plan and getting out in soft/loose soil and disposal of surplus soil upto n.exc. 50m distance complete all as specified and as directed.(Note: Earthwork required for Electrical items also measured and paid under this item) | 514.88 | Cum | 333 ₹1,71,455.04 Lowest | 333 ₹1,71,455.04 Lowest | 900 ₹4,63,392 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed.(Note: Earthwork required for Electrical items also measured and paid under this item) | 336.02 | Cum | 111 ₹37,298.22 | 99 ₹33,265.98 Lowest | 100 ₹33,602 |
| 3.00 | Spreading and levelling in layers not exceeding 25 cm thick and well ramming including watering as required complete all as specified and as directed. | 28 | Cum | 212 ₹5,936 | 225 ₹6,300 | 200 ₹5,600 Lowest |
| 4.00 | M & L Plain Cement Concrete 1:4:8 Type D-2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete complete all as specified and as directed. | 9.85 | Cum | 5,999 ₹59,090.15 | 4,230 ₹41,665.5 Lowest | 8,000 ₹78,800 |
| 5.00 | M & L Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate in foundations including rafts, footings and mass concrete complete all as specified and as directed. | 36 | Cum | 8,888 ₹3,19,968 | 8,100 ₹2,91,600 Lowest | 10,000 ₹3,60,000 |
| 6.00 | M & L Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate) in columns complete all as specified and as directed. | 12 | Cum | 8,888 ₹1,06,656 | 8,100 ₹97,200 Lowest | 10,000 ₹1,20,000 |
| 7.00 | M & L Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. | 15 | Cum | 8,888 ₹1,33,320 | 8,100 ₹1,21,500 Lowest | 10,000 ₹1,50,000 |
| 8.00 | Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate) in slab supported on walls and beams and shelves like complete all as specified and as directed. | 11 | Cum | 8,888 ₹97,768 | 8,100 ₹89,100 Lowest | 10,000 ₹1,10,000 |
| 9.00 | M&L for Providing precast cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate solid building blocks exc. 10 cm in width and setting in cement mortar 1:6 in walls complete all as specified and as directed. | 80.5 | Cum | 7,999 ₹6,43,919.5 | 6,930 ₹5,57,865 Lowest | 10,000 ₹8,05,000 |
| 10.00 | M&L for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate) in chajjas complete all as specified and as directed. | 1.2 | Cum | 8,888 ₹10,665.6 | 8,820 ₹10,584 Lowest | 10,000 ₹12,000 |
Tender Value
₹58.5 L
EMD Value
₹1.1 L
Closing Date
5 Aug 2025, 6:00 pmClosed
GE(S)BANGALORE
GE(S)BANGALORE
PROVISION OF TOILET BLOCKS FOR AGNIVEERS AT CMP C AND S BANGALORE
2025_MES_710739_2
8914/E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
AS PER NIT
6 documents required · 6 mandatory
₹1,000
GE(S)BANGALORE
₹1.1 L
Yes
30 Sept 2025
16 Jul 2025
7 Aug 2025
16 Jul 2025
5 Aug 2025
17 Jul 2025
Amount
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc. and nexc 10 sqm on plan and getting out in soft/loose soil and disposal of surplus soil upto n.exc. 50m distance complete all as specified and as directed.(Note: Earthwork required for Electrical items also measured and paid under this item)
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed.(Note: Earthwork required for Electrical items also measured and paid under this item)
Spreading and levelling in layers not exceeding 25 cm thick and well ramming including watering as required complete all as specified and as directed.
M & L Plain Cement Concrete 1:4:8 Type D-2 using 40 mm graded crushed stone aggregate in foundations, filling and mass concrete complete all as specified and as directed.
M & L Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate in foundations including rafts, footings and mass concrete complete all as specified and as directed.
M & L Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate) in columns complete all as specified and as directed.
M & L Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate) in slab supported on walls and beams and shelves like complete all as specified and as directed.
M&L for Providing precast cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate solid building blocks exc. 10 cm in width and setting in cement mortar 1:6 in walls complete all as specified and as directed.
M&L for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded crushed stone aggregate) in chajjas complete all as specified and as directed.
M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed.
All as per item no.11 above but 6 to 8mm dia complete all as specified and as directed.
M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed.
S & F framed work such as grills, gratings etc. with ends of bars shouldered or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165.
Form work to sides of fdn and PB for rough finished surfaces of concrete complete all as specified and as directed.
Form work to columns for fair finished surfaces of concrete complete all as specified and as directed.
Form work to sides and soffits of beams (roof beam) for fair finished surfaces of concrete complete all as specified and as directed.
Form work to sides and soffits of suspended slab for fair finished surfaces of concrete complete all as specified and as directed.
S&F Powder coated anodised aluminium frame, for door, windows, ventilators runner & packing with rubber gasket etc, with one or more rebates including joinning cleat for rebates including joining cleats for fixing etc, complete all as specified & directed by Engineer-in-Charge.
S&F 4.0 mm thick figured glass, pin head type and glazing with aluminium beading & rubber gasket in each panes in square n.exc 0.5 sqm in each pane in louvers complete all as specified and as directed.
S&F Factory Made single extruded WPC (Wood polymer composite) solid door/windows and other frames / chowkats of size 45mm x 70mm single rebated comprising of virgin PVC polymer of K value 58-60 (SuspensionGrade) calcium carbonate and natural fibres (Wood powder/rice husk/wheat husk) and Non-toxic additives (Maximum toxicity index of 12 for 100 gms) fabricated with mitred joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws withdrawal strength of 2200 N (Face) and 1100 N (Edge) minimum compressive strength of 58 N/Sq mm, modulas of elasticity 900 N/Sq mm and resistance to spread flame of Class A category with property of being termite / borer proof, water/moisture proof and fire retardant and fixed in position with MS holdfast/lugs/SS dash fasteners of required dia and length complete as per direction of Engr-in-Charge. (MS holdfast/lugs or SS dash fastener shall be paid for separately)
S&F Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F 150 mm long aluminium anodised barrel tower bolts and extruded section and fixed complete all as specified and as directed.
S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed .
S&F stainless steel butt hinges 75 mm and fixed complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished smooth and even without using extra cement.
Material and labour for rendering 15mm thick in CM 1:4 mixed with water proofing compound as per manufacturers instructions on external fair faces of brick work or concrete surface finished even and smooth without using extra cement. Note:Water proofing compount shall be measured separately.
M&L for rendering 5 mm thick in ceiling on fair faces of concrete surfaces in cement mortar 1:3 and finished smooth and even without using extra cement.
M&L for 25mm thick PCC (1:2:4) Type B-0 using 12.5mm graded stone aggregate as in sub-base of floor
Supply only liquid water proofing compound complete all as specified and as directed.
M&L 75 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded crushed stone aggregate) in sub base of flooring/ hard standing complete all as specified and as directed.
M & L 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) in floorings/plinth protection including finishing the surface even and smooth without using extra cement complete all as specified and as directed.
S&F non-skid coloured ceramic joint free rectified tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed of 15 mm thick in CM 1:6 etc complete all as specified and as directed.
M&L for glazed coloured ceramic tiles 300x450 mm thick on vertical surfaces such as dados set and jointed in neat cement slurry and pointed in coloured cement to match including 10 mm thick rendering in cement mortar 1:4 etc complete all as specified and as directed.
M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
M&L for newly plaster surfaces of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm incl all necessary safety norms to the workers complete all as specified and as directed.
M & L two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer over 10cm in width or girth not otherwise described after preparation of new or previously untreated steel surface
S&F vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specifed and as directed.
S&F plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specifed and as directed.
S&F 15mm dia quarter turn angle valve chromium plated screwed both ends for iron pipe or unions and fixed for 15mm bore pipe type complete all as directed.
S & F 15mm dia push cock chromium plated screwed both ends for iron pipe or unions and fixed for 15mm bore pipe
S&F PVC low level flushing cistern 10 ltr capacity, valveless, syphonic action type with inlet, ball valve float and handle incl brakcet and flush pipe 32 mm dia complete all as specifed and as directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.. (Cat Part No of Cera F8030105 AB or equivalent in parryware/hindware/prayag)
S&F vitreous china wash hand basin table type, white, size 540 x 360mm including all necessary fittings all as specified and directed.
S & F 15mm dia quaretr turn pillar taps cast copper alloy chromium plated, screwed down high pressure without lettered 'HOT' or 'Cold" with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
S&F brass CP 15 mm bore two way bib cock, quarter turn with wall flange and aerator, complete all as specified and as directed.
S&F 75mm dia PVC (SWR) floor/Nahani trap, plain with CP grating including solvent cement complete all as specified and as directed.
S&F 110mm dia PVC (SWR) 'P' trap complete all as specified and as directed.
S & F 100mm dia PVC (SWR) bends with oval access door
S & F 100mm dia PVC (SWR) bends
S & F 75mm dia PVC (SWR) bends with oval access door
S & F 75mm dia PVC (SWR) bends
S & F 110mm dia PVC (SWR) reducers
S & F 75mm dia PVC (SWR) vent cowls
M&L for 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
M&L for 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls
M&L for 100 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position complete all as specified
S & F 20 mm dia CPVC ball valves complete all as specified.
S&F 20 mm bore Ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete, fixed in repairs, all as specified.
S&F CPVC pipes SDR 11 & plain CPVC SDR 11 fittings of 25mm dia laid on walls / ceiling or laying in floors complete all as specified.
S&F CPVC pipes SDR 11 & plain CPVC SDR 11 fittings of 20mm dia laid on walls / ceiling or laying in floors complete all as specified.
S & F 25mm brass elbow
S & F 25mm brass Tee
S & F 25mm brass male threaded adaptor
S & F 25mm brass female threaded adaptor
S & F 25mm brass tank adaptor
S & F 20mm brass elbow
S & F 20mm brass Tee
S & F 20mm brass male threaded adaptor
S & F 20mm brass female threaded adaptor
S & F PVC liquid soap dispenser fixed with screws on walls complete.
PVC connections 15mm size with PTMT nuts of length 450mm all as specified.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
S & F 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
S & F 18mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work
S & F 1mm thick sunmica laid over plywood fixed with glue complete all as specified and as directed.
S&F large size frameless mirror N45 with beveled edges including all necessary fittings all as specified and directed.
S&F towel rail 600mm long brass CP fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed.
S & F Soap dish, any type, fixed to plugs with chromium plated brass screws
M&L for cleaning the plastered/concrete surfaces with wire brushes and applying water proofing treatment as under: (a) Apply bitumen primer at the rate of 0.27 litre per Sqm as per IS 3384-1986 and bonding bitumen of VG-10 @1.20 Kg per Sqm. (b) APP modified water proofing memebrane as per IS 16540/16532-2017, 3mm thick and weighing not less than 3.80 kg per Sqm reinforce polyster/HMHDPE matt black finish over compatible primer/bonding bitumen and finish the top surface with bituminus aluminium paint @0.10 Ltr per Sqm complete all as specified.
Surface dressing n.exc 0.15 m deep and site clearance getting out in soft/loose soil and site clearance complete all as specified and directed.
Rough Excavation not exceeding 1.5m deep and getting out in soft/loose soil complete, all as specied.
Removing excavated material (soils) to a distance not exceeding 50M and depositing where directed at a level not exceeding 1.5 M above the starting point complete, all as specified and as directed.(Note: Earthwork required for Electrical items also measured and paid under this item)
M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cem ent (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified
M&L Surface excavation of soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out out complete.
M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base or sub floors finishing the surfaces even and rough to receive the topping layer complete all as specified and directed.
M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand;complete all as specified and directed
M&L for providing, cement concrete type C-1 1:3:6 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed plates, kerbs not provided, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Material and labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate in forming channel, benching inside manholes (1/2 or 3/4 section) in manholes and as in coping including necessary form work.
Material and labour for Precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in cover slab for manholes set in CM 1:4 including necessary form work.
Extra for forming fair finished channel or drain of 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred stopped ends etc
Material and labour for PCC 1:3:6 type D2 using 40mm graded stone agrregate for concrete bed to 200mm dia pipe incl packng under and haunching against the sides of pipe after they are laid and tested
Supply and laying 200mm internal dia DWCPE SN-8 pipes confirming to IS-14930 part-2/IS 16025 Part-24,laying including all necessary specials, cutting and jointing as specified and directed
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching
Removing excavated soil material exceeding 1.50 KM but not exc 5 KM and deposited where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed.
M & L for point wiring with 1100 Volts grade 1.5 sqmm PVC insulated FRLSH unsheated cable with multistandred copper conductor conforming to IS: 694:1990 (for phase, Neutral and and Earth) concealed in wall in PVC Conduit all accessories, with cast iron / pressed steel terminal box of sutaible size duly painted inner & outside by anticorrosive paint, including plastic laminated sheet 1.6 mm thick for mounting switches, socket cover with fitting screw washer, including cutting chasses in wall/floor/roof for fixing of PVC Conduit and making good the distributed surfaces matching with existing complete all as specified and as directed by Engr-In-Charge.
One light point controlled by one switch complete all as specified and as directed by Engr-In-Charge.
One fan point controlled by one switch complete all as specified and as directed by Engr-In-Charge.
One switch / 5 Amp socket outlet point as same board with other switches complete all as specified and directed by Engr-In-Charge
One 3 pin 5 Amps socket outlet point on independent board complete all as specified and as directed by Engr-In-Charge.
M&L switch socket outlet 2in1, 3pin,5A complete all as specified and as directed by Engr-In-Charge.
M & L switch piano, flush type single pole, 5 Amps complete all as specified and as directed by Engr-In-Charge.
M&L ceiling rose surface bakelite 65x50 mm two to three terminals.complete all as specified and as directed by Engr-In-Charge.
M&L sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi standard copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through concealed/ casing caping/ PVC conduit as required complete all as specified and as directed by Engr-In-Charge. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
S&F MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, SPN 4 way with 200 Amps rated bus bar , 240 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including complete all as specified and as directed complete all as specified and as directed by Engr-In-Charge.
Supply and fixing MCB SPN 06-40 Amps, 240 Volts complete all as specified and as directed by Engr-In-Charge.
Supply & fixing MCB SP 06-40 Amp, AC, 240 volts, complete all as specified and as directed by Engr-In-Charge.
Supply and fixing surface & wall mounted LED batten 4feet with extruded aluminium housing and robust construction 20 W system lumen including flexible copper 2 core wire from tube light fitting to ceiling rose required length with all accessories all as specified and directed by Engr-in-Charge.
Supply and fixing surface & wall mounted LED batten 2 feet 10 W with luminious efficacy not less than 100 lumen/watt including flexible copper 2/3 core wire from tube light fitting to ceiling rose with mounting provisions and all accessories with color of light warm white/cool day light as reqd at site complete all as specified and directed by Engr-in-Charge.
S&F LED weather proof bulk head light fitting of shape and size as per site requirment of wattage upto 10 watt light fitting with mounting clamp, LED driver holder, LED lamps etc including connecting up to in celling rose complete all as specified and as directed by Engr-in-Charge.
Supply and PVC Body sound proof Exhuast fan 250 mm size with single phase 230 Volt 1200 RPM with louvers Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed by Engr-in - Charge (Make- Havells/ Crompton/ Bajaj)
M & L earthing complete with GI earth plate Electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC chamber and RCC cover slab, connecting lead wire from test point to DB complete all as specified & as directed by Engr-In-Charge.
Supplying and laying of 25 MM CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings complete laid in trenches Complete all as specified and as directed by Engr-In-Charge.
Supplying and laying of 20 MM CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings complete laid in trenches Complete all as specified and as directed by Engr-In-Charge.
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed Complete all as specified and as directed by Engr-in-in Charge.
S & F gun metal gate valve with inner wheel head, screwed both ends in iron pipe and fixed of Size 25 mm Complete all as specifed and as directed by Engr-In-Charge.
Cutting of existing upto 100 mm bore cast iron pipe in position for including insertion of new tees, branches, Bends, Tapers, Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged etc.complete all as specifired and as directed.
S & F gun metal gate valve with inner wheel head, screwed both ends in iron pipe and fixed of Size 20 mm Complete all as specifed and as directed by Engr-In-Charge.
M&L for construction of valve chamber 450x450x450 mm depth with PCC foundation in the ratio 1:4:8 brick work cement mortar in the ratio 1:6 using of class B bricks , PCC 1:2:4 type B0 using 12.5 mm aggregate at the top , plastering 15 mm thick in the ratio 1:4 including MS sheet cover 3mm thick with angle iron frame 50x50x6mm locking arrengement complete with painting on steel surface with two coatsof synthetic enameeled paint over one coat of red oxide paint all as specified and directed . (Earth work shall be measured and paid seperetely in the respective items)
Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm x 2 core including taking down unserviceable UG cable complete all as specified and directed by Engr-In-Charge.
M&L for sand cushioning in trenches for bricks of u/g cable with coarse sand laid dry in trenches with uniform thickness complete all as specified and as directed by Engr-In-Charge.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection all as specified and directed Complete all as specified and as directed by Engr - In - Charge.
S&F MCB, DB double door outdoor type, made out of CRCA mild steel sheet flushed in wall, SPN 2 way with 100 Amps rated bus bar , 240 volts, with PVC MCB blanking plates, dust and vermin proof suitable for incorporation of MCB's and etc including complete all as specified and as directed.
Supply and fixing MCB SPN 6 - 40 Amps, 240 Volts Complete aal as specified and as directed by Engr-In-Charge.
Srisrinivasaenterprises (BID ID -3383270)
VACON INFRASTRUCTURES (BID ID -3383114)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .