SIGNAL
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less ; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. : Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any Signalling work involving trenching, cable laying, termination and outdoor wiring. Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/ 40 / 60% (as the case may be) criteria of similar nature of work.
22 conditions · 13 needing a document upload
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Firm has to submit authorization letter for uploading documents on IREPS in case he/she is not an authorized person.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
Reliability Improvement of Signalling Installation i.c.w improving Signal visibility & minimizing the rectification time of Signal failure & in the section of Sr.DSTE/Co./LKO of Lucknow Division of Northern Railways.
106-Sig-Tender-02-2026-27
106-Sig-Tender-02-2026-27
Open
Works - General
210 Days
Lucknow, Uttar Pradesh
₹0
₹6.1 L
27 Apr 2026
6 Apr 2026
13 Apr 2026
190 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,05,68,602.33 | ||
| — | 3500.00 | — | — | ||
| Excavating and refilling of trench to the level of ground with rammed earth asper Drg. No.(NR/S&T/Con/1.1/97A) so as not to form a drain 0.3 Mtrs wide & 1mtr deep on both side of the station along side the track. It shall confirm to the safe distance as per signalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes. | — | — | — | 1,54,910 | |
| — | 200.00 | — | — | ||
| Excavating and refilling of trench 0.3 Mtrs wide & 0.8 mtr deep on pitced/stone/bricks paved surface, road/crossing/platform etc. and restoration of surafce to original condition. | — | — | — | 28,270 | |
| — | 2000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per attached guidelines (Drg. No.(NR/S&T/Con/1.1/97A) or latest on signalling cable laying and as per cable route plan approved by Railways through trenches, RCC pipe, DWC pipe, GI pipe etc and meggering of cable before and after its laying of all type of outdoor cables. Contractor have to transport cable from any store of LKO division to site carefully. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways, as per instructions by Consignee. | — | — | — | 10,880 | |
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/Con./1.1/97A) or latest and as per instruction of the site Engineer. | — | — | — | 1,63,240 | |
| — | 200.00 | — | — | ||
| Boring and trenchless cabling along with supply and insertion of HDPE/DWC self lubricated pipes as per RDSO Spec no. RDSO/SPN/204/2011 Ver 1.1 or latest of 120mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by Engineer Incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. Inspection-Consignee for Supply of DWC/HDPE pipe. The following required coupling arrangement should also be supplied: 1. Suitable snap fit couplers withrubber O ring, 2. Spacers, 3. Tees. 4. Bend. 5. End Cap(1 no. =6mtr ,Straigh tpipe). (A) The cost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (B) The rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. Nothing extra shall be admissible on any account than the rate quoted above. (C) The Pipeis to be laid underrailway track/road /culvert. All necessary arrangement are to be provideand all precautions are to be end is not deviated from the horizontal level line by more than 250mm in horizontal and vertical direction. (D) The rate shall be inclusive of direction and protection of underground utilities encountered during boring. (E) The payment for boring shall be made only when DWC/HDPE pipe are laid in the bore. | — | — | — | 2,61,298 | |
| — | 50.00 | — | — | ||
| Concreting unschduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement sand ratio. It also includes the excavation of earth as required at site and as per instruction of site incharge. The volume in cubic metres shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. Cement coarse sand and aggregate 25mm are to be supplied by the contractor. | — | — | — | 1,85,817.5 | |
| — | 500.00 | — | — | ||
| Earth work for excavation and refilling around location boxes and signals etc. where necessary including 50M lead and 1.5M lift. The lead is to be measured from centre of gravity of location to the centre of filling and lift from main ground level. The earth work should be well rammed including breaking of clods, levelling and dressing etc. as per instruction of Engineer at site. | — | — | — | 81,815 | |
| — | 100.00 | — | — | ||
| Brick work with well burnt bricks in foundations and plinths with cement and sand (ordinary) mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection: Engg representative.) | — | — | — | 2,64,444 | |
| — | 7.00 | — | — | ||
| Supply of wiring materials as per IS Spec. No. 2465/1984 with latest Amend. and IS694/2010 or latest Copper wire, PVC insulated sizes as under. (a) Power wire 1*6 Sq. mm (No ofstrand-85 & diameter of strand-0.30 mm + - 0.00, insulation thickness 0.80 mm Normal conductor Resistance 3.30Ohm/Km (RED & BLACK colour 50% each) Material to be procured from RDSO approved firm. Test parameters are as per(IRS) /76/89 (Amdnt.3). Inspection : Consignee | — | — | — | 3,91,235.25 | |
| — | 10.00 | — | — | ||
| Supply of cable/wire indoor copper conductor single/multi core plain annealed high conductivity PVC insulated unarmored as per Spec.no. IRS-S/76/89(Amdt. 3) or latestamendment of the following sizes:-(i) Wire 1*1mm/16*0.2mm. Inspection by Consignee (to be procurred From RDSO Approved Source only) | — | — | — | 78,979.7 | |
| — | 2070.00 | — | — | ||
| Supply of round head type non-deteriorating type low voltage cartridge fuse as per RDSO Specn.No.IRS:S-78/92 or latest and Capacity - 2/4/6/10A/16A/20A Amp. (material will be supplied only from approved vendors of RDSO). Inspection- RDSO | — | — | — | 1,10,765.7 | |
| — | 690.00 | — | — | ||
| Supply of round head type non-deteriorating type low voltage cartridge fuse as per RDSO Specn.No.IRS:S-78/92 or latest and Capacity - 630 mili Amp. (material will be supplied only from approved vendors of RDSO). Inspection - Consignee | — | — | — | 37,991.4 | |
| — | 2760.00 | — | — | ||
| Supply of glass fuse 0.63A/1A/2A/4A/6A/10A/16A each. Inspection - Consignee | — | — | — | 81,199.2 | |
| — | 4950.00 | — | — | ||
| Loading, Leading & unloading of materials from store to another store as per instruction of consignee. All the material to be transported carefully without damage. Contractor have to do proper stacking of material and prepare list of material. | — | — | — | 25,938 | |
| — | 38.00 | — | — | ||
| Engaging mechanical excavators like JCB or other machineries for regarding and leveling the formation, Dismantling any infringing structures, clearing and removing debris etc., with all lead and lifts etc., complete and as per the instruction of railway representative at site. | — | — | — | 40,707.12 | |
| — | 120.00 | — | — | ||
| Supply of Relays - Miniature, Plug in Type, M to C, Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact, 24 V DC, Code BCEJK Spec: BRS:943 ; IRS S 34 ; IRS S 23 ;IRS S 60-78, STR: SIQ 0420 Ver.1 or latest. Inspection:- RDSO | — | — | — | 8,93,212.8 | |
| — | 80.00 | — | — | ||
| Supply of RELAYS - Miniature, Plug-in type, M to C, DC Neutral Line Relay, 24V DC 1000 Ohm , ACI Style- QNA1K, 6F-6B/4F-4B Contact, Code CDEKY/CDEKY Spec: BRS:931A & STs/E/Relays/UEA/PI dtd 30.05.97 Annex II & IRS:S-23, 34 & 60, STR: SIQ 0420 Ver.1 or latest. Inspection : RDSO | — | — | — | 5,12,108.8 | |
| — | 100.00 | — | — | ||
| Supply of Relays -RELAYS -Miniature, Plug-in Type, M to C, DC Neutral Line Magnetically Latched Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRS S 34 ; IRS S 23, STR: SIQ 0420 Ver.1 or latest. Inspection:- RDSO | — | — | — | 5,99,412 | |
| — | 250.00 | — | — | ||
| Preparation of Panel Diagram, location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad. The drawings shall be prepared in A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print . The drawings shall be checked and returned by Railways indicating corrections if any. The correction shave to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in Pendrive. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways. c. For preparation of soft copy from U size hard copy. (The Rate is for per Sheet) | — | — | — | 2,11,962.5 | |
| — | 250.00 | — | — | ||
| Supply of Original Tracings of A-3 Size. NOTE:- For Drawings larger than A-3 Size, payment shall be made in multiples of A-3 Size. Inspection- Consignee | — | — | — | 19,660 | |
| — | 12.00 | — | — | ||
| Supply, Transportation, Installation & Commissioning with OEM certification of SMPS- based Modular Power Supply Arrangement for VDU (42"- 85") and Industrial PC (Embedded PC) with input and output redundancy arrangement and hot-pluggable modules as per RDSO latest TAN for VDU/Embedded PC Power Supply Arrangement. Each set consisting of: - 1) Input O-Ring diode module with digital volt/ammeter, potential-free contact for two sources of 110V DC from IPS and one output 110VDC Bus - 1 Nos. 2) SMPS-based Isolated Inverters- 2 nos., with digital volt/ammeter, Input: 110VDC, Output: 110VAC/500VA pure sine, and Active Current Sharing at 50% - 100% load. 3)SMPS-based Isolated DC-DC converters - 2 nos., with digital volt/ammeter, Input: 110VDC, Output: 24VDC/10A, and Active Current Sharing at 50% - 100% load. 4)3U Stainless Steel rack with back panel motherboard and front panel power connectors, and all required protection circuits. Inspection- RDSO | — | — | — | 26,51,516.64 | |
| — | 4.00 | — | — | ||
| Supply, Transport, Loading, Leading, Unloading & Installation of used marine container with the following details: size 40 ft x 8 ft x 9.5 ft (l x b x h). material: corten steel (minimum 1.6 mm thickness of wall & minimum 2 mm thickness of roof panel). usage: storage application. floor: made up of water proof ply of thickness of minimum 28mm. container type: dry container. capacity: 30-40 ton. inside coating: enamel paint white. required fittings: to be supplied and installed along with container. requirement of shelf: 2 layer of wooden shelf fitted on suitable hs angle along 40 ft wall both sides. size of shelf: depth- 2ft, length 40 ft. layer 1 to be installed at a height of 2.5 ft from ground & layer 2 to be installed at a height of 4.5 ft from ground. number of doors: 01 nos of size minimum 4ft x 6ft (wxh). number of windows: 04 nos of size 3 ft x 3 ft (wxh). suitable arrangement for closing the window with grill should be provided. number of exhaust fan to be supply and installed - 02 nos. number of tube lights to be supply and installed 04 nos. wiring & provision of switch for exhaust and tube light to be done inside the container. Inspection- RITES | — | — | — | 18,40,000 | |
| — | 40.00 | — | — | ||
| Glued Joint Sealant as per below specification: 1. Excellent ageing and weathering resistance 2. Excellent UV resistance . 3. High Temperature resistance up to 300 Degree centigrade or better 4. Non flammable , Non toxic . 5. Dielectric Constant @ 1 MHz to be 2.0 TO 3.5 . 6. Each CAN must have at least 250 ml paste. 7. Tensile Strength @ 1.30 N/mm2 or better 8. Hardness @ 54 shore A or better 9. Elongation @ 200% .approx or better 10. Density @ 1.5 gm/cm2 or better 11. Thermal conductivity @ 0.30 w/Mk or better. Inspection- Consignee | — | — | — | 1,63,076 | |
| — | 15.00 | — | — | ||
| Supply of Limit switch,Timing belt and Push button as spares for ELB as per RDSO specification RDSO/SPN/208/2012 or latest as mentioned.- (a) Limit switch 2 No 2 NC =50 Nos. (b) Limit switch 1No 1 NC=50 Nos.(c) Limit Switch (1 Lever Type, 2 Top Roller type)=50 Nos. (d) Timing belt big for padestal =50 Nos. (e) Timing Belt for locking (L 98)=50 Nos.(f) Push Button Complete with Element =20 Nos. Inspection-RDSO/RITES | — | — | — | 51,81,030.9 | |
| — | 4.00 | — | — | ||
| Supply, installation & commissioning of system rack 2kVA for Input 110V DC & output 110V AC with double isolation comprising of 1 nos module of Inverter of 2kVA, 110V DC/230 V AC & 1 nos module of step down T/F 2kVA 230 V AC/110V AC 2 kVA system shall have surge arrestors at the output. Meter- Digital type, Input DC voltmeter, output AC voltmeter The above modules shall confirm to RDSO spec. no. RDSO/SPN/165/2023 ver- 4.0 with Amendmend 1 or latest. Inspection- RDSO for supply portion. | — | — | — | 6,15,177.92 | |
| — | 70.00 | — | — | ||
| Supply of Water Distiller (UD-WD2), Inner and outside Stainless Steel 304 Grade Body, capacity 4 litre. Inspection- Consignee | — | — | — | 6,65,000 | |
| — | 19.00 | — | — | ||
| Supply, Installation of motorized locking complete 110V AC suitable for Global make POLB as per RDSO Specification No. RDSO/SPN/208/2012 ver. 2.0 with Amendment-1 or latest. Make/Brand-GLOBAL DEVICES, 2 Nos of Motorized Locking Per SET. Inspection-RDSO | — | — | — | 17,99,205 | |
| — | 100.00 | — | — | ||
| Supply of Switch Plate lubricant- Cenolube 100 or better NLGI 00 GRADE Black colored which should be non asphaltic Non bituminous blend of very heavy oils, inert thickeners and lubricating solids coupled with molybdenum disulfide and graphite with no traces of chlorinated solvent such as 1,1,1 trichloroethane which are flammable and harmful to the environment. Should have a blend of select high viscosity index solvent refined severely hydrofinished paraffin base oils and synthetic base fluids. It should incorporate solid lubricants & organo molybdenum disulphide to fill & lubricate micronized asperities to provide & form many films on the contact surfaces to prevent metal-to-metal contact. It shall be designed to be hand applied providing a tough adherent Lubricant film with Tacky semi-dry finish reducing contaminant adhesion. The grease Should Not form a difficult to remove thick DRY film which requires scrapping & solvent cleaning of Switch Plate specially before reapplication The grease should Not need Cleaning or scrapping before Reapplication. The Grease should be formulated for tropical climates and should not contain pour point depressants and should Not be too thin. The grease shall be Resistant to water wash off & dilution, water insoluble, non-melt and chemically resistant to exposed environment. The grease shall be formulated with Extreme Pressure additives, rust and corrosion inhibitors, anti wear additives to protect external surfaces against the harsh elements in severe climates, thus reducing rust binding and adhesive wear on switch plates Four Ball Weld LOAD (ASTM- D2596) >600 Kg, Copper corrosion 24 hrs @ 100c (ASTM D 4048) 1a-2e packing Size 20 kg /25kg Drum. Inspection- Consignee | — | — | — | 4,57,230 | |
| — | 98.00 | — | — | ||
| Supply of electric fuse complete with fuse block (base) for Railway signalling non deteriorating type lowvoltage fuse assembly 2Amp/4Amp/16Amp. to suit Specn. No. IRS: S-78/92 or latest and fuse block made of PBT/Polycarbonate as per IRS:S-75/2006 (Rev.2 & Amd.2) and drg no. 23748 (IRS), Alt-4 or latest. Fuse block shall besuitable for round head type fuses. Inspection : RDSO for both Fuse and Fuse block | — | — | — | 19,121.76 | |
| — | 20.00 | — | — | ||
| Supply of 24-40V/5A DC-DC convertor Statcon make IPS as per RDSO specification No. RDSO/SPN/165/2012 ver 3.0 or latest suitable for existing IPS to be supplied by OEM or its authorised dealer. Inspection - RDSO | — | — | — | 4,59,464.4 | |
| — | 2.00 | — | — | ||
| Supply of Spare Cards of WEBFIL make Universal Fail Safe Block Interface (UFSBI) equipment as per IRS:S-105/2012 ver 0, and be compatible with existing system. PSU CARD. Inspection- Consignee | — | — | — | 1,02,979.38 | |
| — | 2.00 | — | — | ||
| Supply of Spare Cards WEBFILL SYSTEM CARD of WEBFIL make Universal Fail Safe Block Interface (UFSBI) equipment as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 68,445.5 | |
| — | 2.00 | — | — | ||
| Supply of Spare Cards of WEBFIL make Universal Fail Safe Block Interface (UFSBI) equipment as per IRS:S-105/2012 ver 0, and be compatible with existing system. Communication Card. Inspection- Consignee | — | — | — | 80,151.1 | |
| — | 2.00 | — | — | ||
| Supply of Spare Cards of WEBFIL make Universal Fail Safe Block Interface (UFSBI) equipment as per IRS:S-105/2012 ver 0, and be compatible with existing system. INPUT CARD. Inspection- Consignee | — | — | — | 36,502.12 | |
| — | 2.00 | — | — | ||
| Supply of Spare Cards of WEBFIL make Universal Fail Safe Block Interface (UFSBI) equipment as per IRS:S-105/2012 ver 0, and be compatible with existing system OUTPUT CARD. Inspection- Consignee | — | — | — | 68,610.7 | |
| — | 2.00 | — | — | ||
| Supply of Spare Cards of WEBFIL make Universal Fail Safe Block Interface (UFSBI) equipment as per IRS:S-105/2012 ver 0, and be compatible with existing system. FEEDBACK CARD. Inspection- Consignee | — | — | — | 35,894.82 | |
| — | 2.00 | — | — | ||
| Supply of Display Card with reset box suitable and compatible with existing Webfil make Universal Fail Safe Block Interface (UFSBI) equipment as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 56,142.04 | |
| — | 2.00 | — | — | ||
| Supply of Block Telephone with Block Alarm Panel PCB suitable to work with block panel & UFSBI of WEBFIL Make as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 23,600 | |
| — | 4.00 | — | — | ||
| Supply of Input Card suitable for DELTRON make Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 50,927.24 | |
| — | 4.00 | — | — | ||
| Supply of Output card suitable for DELTRON make Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 1,05,070.36 | |
| — | 4.00 | — | — | ||
| Supply of CC Card suitable for DELTRON make Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 1,07,773.32 | |
| — | 4.00 | — | — | ||
| Supply of Modem compatible with DELTRON make Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 1,19,101.32 | |
| — | 4.00 | — | — | ||
| Supply of CPU Card suitable for DELTRON make Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 1,25,080 | |
| — | 4.00 | — | — | ||
| Supply of Mother Board suitable for DELTRON make Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 1,64,240.28 | |
| — | 4.00 | — | — | ||
| Supply of 4-wire Modem suitable for DELTRON make Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 1,87,270.72 | |
| — | 4.00 | — | — | ||
| Supply of Reset Box suitable for DELTRON make Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 85,262.08 | |
| — | 4.00 | — | — | ||
| Supply of Flat cable set suitable for Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 13,058.68 | |
| — | 4.00 | — | — | ||
| Supply of DC-DC Converter (No 1 stand by type) Compatible with DELTRON Make Universal Fail Safe Block Interface (UFSBI) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Inspection- Consignee | — | — | — | 1,64,098.68 | |
| — | 16.00 | — | — | ||
| Supply of Block Telephone (Complete with PTT Handset) as per IRS:S-105/2012 ver 0, and be compatible with existing system. Suitable to work with Block Panel & UFSBI of DELTRON Make. Inspection- Consignee | — | — | — | 2,80,053.28 | |
| — | 4.00 | — | — | ||
| Supply of PD-1 (21KHz) Card suitable for G.G. Tronics make HASSDAC as per specification no. RDSO/SPN/177/2012, (Ver.3) and be compatible with existing system. Inspection- Consignee | — | — | — | 1,62,469.48 | |
| — | 4.00 | — | — | ||
| Supply of PD-2 (25KHz) CARD suitable for G.G. Tronics make HASSDAC as per specification no. RDSO/SPN/177/2012 (Ver.3) and be compatible with existing system. Inspection- Consignee | — | — | — | 1,66,387.08 | |
| — | 4.00 | — | — | ||
| Supply of COM CARD suitable for G.G. Tronics make HASSDAC as per specification no. RDSO/SPN/177/2012 (Ver.3) and be compatible with existing system. Inspection- Consignee | — | — | — | 1,15,545.6 | |
| — | 4.00 | — | — | ||
| Supply of CPU 2 card suitable for G.G. Tronics make HASSDAC as per specification no. RDSO/SPN/177/2012 (Ver.3) and be compatible with existing system. Inspection- Consignee | — | — | — | 2,59,431.64 | |
| — | 4.00 | — | — | ||
| Supply of CPU 1 card suitable for G.G. Tronics make HASSDAC as per specification no. RDSO/SPN/177/2012 (Ver.3) and be compatible with existing system. Inspection- Consignee | — | — | — | 2,63,926.68 | |
| — | 4.00 | — | — | ||
| Supply of 24V-48V PS Card suitable for GG Tronics make HASSDAC as per RDSO specification No: RDSO/SPN/177/2012 version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 20,768 | |
| — | 4.00 | — | — | ||
| Supply of DC-DC converter suitable for GG Tronics make HASSDAC as per RDSO specification No: RDSO/SPN/177/2012 version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 1,21,461.32 | |
| — | 4.00 | — | — | ||
| Supply of RD-1 CARD suitable for GG Tronics make HASSDAC as per RDSO specification No: RDSO/SPN/177/2012 version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 1,01,037.52 | |
| — | 4.00 | — | — | ||
| Supply of Event Logger suitable for GG Tronics make HASSDAC as per RDSO specification No: RDSO/SPN/177/2012 version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 2,22,049.24 | |
| — | 6.00 | — | — | ||
| Supply of Signal Conditioner Card No.1 (SCC1) suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 2,38,360.02 | |
| — | 6.00 | — | — | ||
| Supply of Signal Conditioner Card No.2 (SCC2) suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 2,36,236.02 | |
| — | 6.00 | — | — | ||
| Supply of Dual MLB Card No.4 suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- RDSO/RITES | — | — | — | 5,73,244.02 | |
| — | 6.00 | — | — | ||
| Supply of Modem Card suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 2,32,435.98 | |
| — | 6.00 | — | — | ||
| Supply of Relay Drive Card suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 2,33,875.98 | |
| — | 6.00 | — | — | ||
| Supply of DC-DC Converter suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 1,37,587.98 | |
| — | 4.00 | — | — | ||
| Supply of New Reset Box RB 259A suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 2,14,760 | |
| — | 4.00 | — | — | ||
| Supply of Reset card of Reset Box suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 75,362.68 | |
| — | 4.00 | — | — | ||
| Supply of Auto Reset Card suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 75,677.32 | |
| — | 4.00 | — | — | ||
| Supply of Interface card suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 1,17,213.32 | |
| — | 6.00 | — | — | ||
| Supply of LCD display for reset box suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 12,036 | |
| — | 4.00 | — | — | ||
| Supply of Event Logger Card suitable for CEL Make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3.0 and be compatible with existing system. Inspection- Consignee | — | — | — | 1,89,083.2 | |
| — | 8.00 | — | — | ||
| Supply of Axle Detector (AD-711 FS) each set consist of Clamp Type 02 No. of TX Coil and 02 No. of RX Coil including mounting accesseries for 60 KG rail with 10 mtr cable length for CEL make SSDAC/HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 (ver.3.0) and be compatible with existing system. Inspection- RDSO/RITES | — | — | — | 7,05,168 | |
| — | 2.00 | — | — | ||
| Supply of Relay Drive Card for central Evaluator Unit of Multi Section Digital Axle Counter Systems CEL make as per RDSO spec.No. RDSO/SPN/176/2013 ver.3 and be compatible with existing system. Inspection-Consignee | — | — | — | 2,36,000 | |
| — | 2.00 | — | — | ||
| Supply of Configuration card for central Evaluator unit of Multi Secton Digital Axle Counter systems CEL make as per RDSO Specn. No.RDSO/SPN/176/2013 ver.3 and be compatible with existing system. Inspection- Consignee | — | — | — | 70,800 | |
| — | 2.00 | — | — | ||
| Supply of Event Logger Card for Central Evaluator of Multi Secton Digital Axle Counter systems CEL make as per RDSO Specn. No.RDSO/SPN/176/2013 ver.3 and be compatible with existing system. Inspection- Consignee | — | — | — | 1,18,000 | |
| — | 2.00 | — | — | ||
| Supply of Evaluator Card (EMO8) for Central Evaluator Unit of Multi Section Digital Axle Counter system CEL make as per RDSO Specn. No.RDSO/SPN/176/2013 ver. 3 and be compatible with existing system. Inspection- RDSO/RITES | — | — | — | 7,59,935.74 | |
| — | 2.00 | — | — | ||
| Supply of High Voltage DC-DC Converter Module DC 210 for converting 24V DC to 96 V DC of Multi Secton Digital Axle Counter systems CEL make as per RDSO Specn. No.RDSO/SPN/176/2013 ver.3 and be compatible with existing system. Inspection- Consignee | — | — | — | 1,18,000 | |
| — | 2.00 | — | — | ||
| Supply of Power & Data coupling unit (PDCU) for Multi Secton Digital Axle Counter systems CEL make as per RDSO Specn. No.RDSO/SPN/176/2013 ver.3 and be compatible with existing system. Inspecion- Consignee | — | — | — | 37,760 | |
| — | 2.00 | — | — | ||
| Supply of Surge Arrestor for Multi Secton Digital Axle Counter systems CEL make as per RDSO Specn. No.RDSO/SPN/176/2013 ver. 3 and be compatible with existing system. Inspecion- Consignee | — | — | — | 37,760 | |
| — | 2.00 | — | — | ||
| Supply of SM Panel Card (Supply) for Multi Section Digital Axle Counter Systems CEL make as per RDSO spec.No.RDSO/SPN/176/2013 ver. 3 and be compatible with existing system. Inspection-Consignee | — | — | — | 59,000 | |
| — | 2.00 | — | — | ||
| Supply of SM Panel Card (8 Ch. Reset) for Multi Section Digital Axle Counter Systems CEL make as per RDSO spec.No.RDSO/SPN/176/2013 ver.3 and be compatible with existing system. Inspection-Consignee | — | — | — | 1,29,800 | |
| — | 2.00 | — | — | ||
| Supply of Dual Micro Controller Logic card for Field Unit of Multi Section Digital Axle Counter Systems CEL make as per RDSO spec.No.RDSO/SPN/176/2013 ver.3 and be compatible with existing system. Inspection- Consignee | — | — | — | 1,83,293.34 | |
| — | 2.00 | — | — | ||
| Supply Auto Reset Module (ARM-271-V01) Track Section compatible with existing CEL Make MSDAC as per RDSO Specification No. RDSO/SPN/176/2013 with version 3 and be compatible with existing system. Inspection- Consignee | — | — | — | 96,760 | |
| — | 6.00 | — | — | ||
| Supply of Vital Relay Box Model VR-722 duly wired with following relays for CEL make HASSDAC as per RDSO Specification No.RDSO/SPN/177/2012 with version 3 and be compatible with existing system: (a) Vital Relays QN1K, 24V, 6F-6B -2Nos. (b) Reset Relay QN1K, 24V, 6F-6B -1Nos. (c) PR Relay QNN1, 24V, 6F-2B (Dual) - 1No. Inspection-Consignee | — | — | — | 2,83,200 | |
| — | 4.00 | — | — | ||
| Supply of Wheel sensor ZK24-2 with 10 mtr cable & cable protection tube, Part No. AP215595 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- RDSO/RITES | — | — | — | 5,48,784.96 | |
| — | 4.00 | — | — | ||
| Supply of Power Supply Protection Module (ZANAP), Part No. AP215625 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 1,59,328.32 | |
| — | 4.00 | — | — | ||
| Supply of Input Amplifier Module (UP), Part No. AP215629 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 2,60,827.2 | |
| — | 4.00 | — | — | ||
| Supply of Relay Output Module (RE), Part No. AP215613 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 3,13,672.32 | |
| — | 4.00 | — | — | ||
| Supply of Micro Processor unit, Part No. AP215623 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- RDSO/RITES | — | — | — | 13,09,516.8 | |
| — | 4.00 | — | — | ||
| Supply of Lightning Protection Board (ZAG2Z), Part No. AP215633 as per RDSO specification No.RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 1,35,312.96 | |
| — | 4.00 | — | — | ||
| Supply of Power Supply Module (DC12), Part No. AP215624 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 4,20,212.16 | |
| — | 4.00 | — | — | ||
| Supply of Main Board, Part No. AP215630 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 1,73,544.96 | |
| — | 4.00 | — | — | ||
| Supply of Tool kit for MSDAC as per RDSO specification No. RDSO/SPN/176/2013 Ver.- 3 suitable with existing installations of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 4,67,280 | |
| — | 5.00 | — | — | ||
| Supply of Reset Box, part no AP215650 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 89,349.6 | |
| — | 4.00 | — | — | ||
| Supply of BO 23 rack, part no. AP 215621 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of MSDAC M/s.Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 1,03,707.84 | |
| — | 4.00 | — | — | ||
| Supply of CONNECTOR BOARD (Module KP) Part no. AP 215640 as per RDSO specification No. RDSO/SPN/176/2013 Ver.-3 suitable with existing installations of Sigma Rail Systems Pvt. Ltd. Inspection- Consignee | — | — | — | 1,03,707.84 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Doc
ATTACHMENT
GCCAdvanceCorrectionSlipno7-10.pdf
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
ACSGCC22-231to6.pdf
ATTACHMENT
TD-02-2026-27ReliabilityImprovementSrDSTECLKO_3.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .