Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.0 L+₹88,679.16 (2.68%)Rejected-AOC VILL BUNGDAL DADHANI P O BADHANI DISTT PATHANKOT PIN 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹35.8 L+₹2.7 L (8.24%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹36.0 L+₹2.9 L (8.63%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹36.5 L+₹3.4 L (10.4%)Rejected-AOC 137 MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC Rejected |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
19 Feb 2022, 6:00 pmClosed
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun PIN-145001
SPL REPAIR TO BLDG NO NP-03 OF SIG CENTRE, ROOF TREATMENT AND ALLIED WORKS TO BLDG NO P-72, P-75, SEWEAGE LINE AT CANDETH ENCLAVE AND PROVN OF INDUSTRIAL TILE TO KITCHEN OF BLDG NO P-14 (CK HOUSE) UNDER AGE BR-I OF GE (N) MAMUN
2022_MES_501934_1
GE(N)/M-65/2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹86,000
21 Mar 2022
17 Jan 2022
21 Feb 2022
17 Jan 2022
19 Feb 2022
2 Feb 2022
Amount
Demolition of brickwork built in cement mortar including all quions ,arches,pillars etc but excluding ashlar facings dressed stonework and precast concrete articles, rubbish off the premises complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:4) complete all as specified and directed.
Demolition and breaking up drain pipes 200mm dia (salt glazed ware, AC ,PVC or reinforced concrete) set in cement mortar rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc rubbish off the premises complete all as specified and directed.
M&L for rendering 15mm thick in two layers (base layer 10mm & finishing layer mixed with WPC, 5mm thick) in cement mortar (1:4) using liquid water proofing compound on brick work or concrete surfaces of wall, surfaces finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches or floors, if required S&F 100 mm bore sand cast iron soil waste and vent pipes ISI marked in any length with or without ears laid in floor with cement joints complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches or on walls, if required S&F 100mm bore sand cast iron soil waste and vent pipes ISI marked in any length with or without ears fixed to walls with clamps and cement joints acomplete all as specified and directed.
S&F in repair 100 mm dia CI bends (any radius) diminishing pieces or tapers (larger bore measured)complete all as specified and directed.
S&F PVC(SWR) pipes 110mm bore, single socketd , in any length with rubber ring joints , in any length laid in trenches or in floors complete all as specified and directed.
S&F PVC(SWR) pipes 75mm bore, single socketd , in any length with rubber ring joints , in any length laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) bend any radius 75mm dia bore complete all as specified and directed.
S&F PVC (SWR) bend any radius 110mm dia bore complete all as specified and directed.
S&F in repair Cast Iron Branch peices, single(equal or unequal) ordinary or inverted (spigot or socket type), or with parrallel branches fitted with oval access doors of 100 mm bore dia complete , ISI Marked, complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out on walls, if required, rubbish off the premises S&F 50mm bore cast iron soil waste and vent pipes, sand cast, ISI marked in any length with or without ears fixed to walls with clamps and cement joints complete all as specified and directed.
S&F in repair 75 mm dia CI bends (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F in repair Cast Iron Branch peices, Double (equal or unequal) ordinary or inverted (spigot or socket type), or with parrallel branches fitted with oval access doors of 75 mm bore dia complete , ISI Marked, complete all as specified and directed.
S&F in repair cast iron cowl for 50 mm dia complete all as specified and directed.
Excavation and trenches n. exc 1.5 m wide and n.exc 1.5m in depth for foundation of manhole etc and getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point and disposal complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC type B-1 (using 20 mm graded crushed stone aggregate) as in kerb stones , coping, bed plates and the like including weathering, slightly roundered or chamfered angles and throating as directed including necessary form work and finishing complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in surface channels & drains complete all as specified and directed.
M&L for Extra for forming fair finished drain or channel 60cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc. complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia secruing with clips complete all as specified and directed.
M&L for Precast cement concrete type B1 1:2:4 (using 20 mm graded crushed stone aggregate) in landings, cover slab, manhole cover etc, water troughs, shelves and similar articles with plain faces set in cement mortar 1:4 omplete all as specified and directed.
M&L for concrete bed to drain pipes including forming cradles in cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) for 200 mm dia pipe complete all as specified and directed.
M&L for 200mm bore, reinforced cement concrete pipes class NP2 with one collar per length of pipe complete all as specified and directed.
M&L for Construction of Brick masonry Septic tank for 150 Users including inlet and outlet chamber complete all as shown in Drg No CEPZ/C-TD/013/13 sheet Nos 1/5 to 5/5 using bricks (non modular) complete all as specified and directed.
M&L for Construction of Brick masonry Soakage well 3.00 metre dia and 3.00 metre deep below inlet pipe complete all as shown in Drg No CEPZ/C-TD/013/13 sheet Nos 1/5 to 5/5 using bricks (non modular) etc complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, rubbish off the premises complete all as specified and directed
M&L for 75 mm thk PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in subbase to flooring complete all as specified and as diretcted.
M&L for 25 mm thick sand cushion under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for 60mm thick precast interlocking paver blocks factory made confirming to IS-15658-2006, grade of concrete M-35 with cement and coloured pigment (topping thickness shall be not less than 5 mm thick with white cement and colour pigment non fadable with epoxy coating) complete all as specified and as directed.
M&L for rendering or plastering work 10mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas, roof projections etc, including taking out peeled off plaster / concrete and making the line in true shape, finishing the surface without using extra cement using liquid water proofing compound . (Note : WPC shall be measured and paid separately)
M&L for preparation of new plastered surface of external wall and chajjas, making the surface smooth with sand paper, priming the surface with alkali resistance primer paint and applying two coats of cement base paint including curing complete all as specified & directed.
M&L for preparing old wall surface including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and applying two coats of acrylic, antifungal emulsion exterior weather proof paint on external surfaces, complete all as specified & directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 15mm bore pipe complete all as specified & directed.
All as per item 38 but 20mm bore pipe.
S&F 15mm bore tubes medium grade, galvanized, ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc complete all as specified & directed.
All as per item 40 but 20mm bore pipe.
Refixing of old steel tubing 15 mm medium grade galvanized ISI marked with new fittings short pieces and fixed complete to walls, floor etc complete all as specified & directed.
All as per item 42 but 20mm bore pipe.
M&L for cutting chases pinning in brick mass, making good to facing where required, pointed in cement and making good in CM 1:3, cutting n.exc. 10 cm in girth complete all as specified & directed.
Dismantling of existing PVC tank of any capacity, S&F Rotational moulded polyethlene water storage tanks of capacity 1000 litres, three layered (cylindrical vertical with closed top, as per sample) hoisted and fixed in position all as specified in SSR Part I, including 20mm dia ball brass valve high pressure with polythene float, complete all as specified & directed.
S&F in repair 20 mm bore dia gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed, cast copper alloy, chromium plated fancy type, ISI marked with crutch or butter fly handles, screwed down, screwed for iron pipe complete all as specified & directed.
Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for, rubbish off the premises complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 using crushed graded stone aggregate in padding as roof , surface finished even and smooth without using extra cement complete all as specified and as directed.
S&F plain aluminium sheet of 0.71 mm thick over expansion joints fixed to walls complete all as specified and as directed.
Dismantling of brick tiles, terracing tiles, single layer from roof laid, bedded and pointed in any mortar rubbish off the premises complete all as specified and as directed.
M&L for 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction or @ 0.200 ltr in 50 Kg of cement complete all as specified and as directed.
M&L for APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet walls, to be executed through approved applicator of the membrane manufacturer with following specification complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. (d) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
Supply only liquid water proofing compound
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Rendering 5 mm thick cement plaster in cement mortar (1:3) as in ceiling finished even and fair without using extra cement all as specified and directed.
M&L for Preparation of new plastered surface of walls, applying wall care putty in one or more coat of any thickness to obtain the surface level and smooth and applying two coats of oil emulsion distemper complete all as specified & directed.
M&L for three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified & directed.
M&L for two coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified & directed.
M&L for complete removal of existing treatment, rubbish off the premises, applying wall care putty in one or more coat of any thickness to obtain the surface level and smooth and applying two coats of oil emulsion distemper complete all as specified & directed.
M&L for preparation of old plastered surface of walls and applying two coats of white wash complete all as specified & directed.
M&L for for preparation of old plastered surface of ceiling and applying two coats of white wash complete all as specified & directed.
M&L for complete removal of existing treatment, rubbish off the premises, applying wall care putty in one or more coat of any thickness to obtain the surface level and smooth applying two coats of cement base paint over a coat of alkali-resistant priming paint all as specified & directed.
S&F GI wire netting 0.90mm dia & 12mm mesh lathing to wood or metal studding, joists, etc., in walls, ceilings, stanchions, beams, etc. including all laps, cutting & waste complete all as specified and directed
Dismantling old floor tile including cement mortar bedding rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including screed bed or bedding layers of mortars 15 mm thick in CM 1:4 complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in skirting/dado/risers of steps etc set and jointed in neat cement slurry to match and pointed in coloured cement over and including bedding layer of mortar 10mm thick in CM (1:4), finished rough, taking down cement plaster on walls etc, rubbish off the premises complete all as specified and directed.
All as per item 66 but glazed ceramic coloured tiles in vertical surface 450x300x7mm thick.
S&F in repair stop valve/ Angle valve cast copper alloy (ISI Marked) chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15mm bore dia, complete all as specified and directed.
S&F in repair stop valve, concealed, cast copper alloy (ISI Marked) fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with capstan head screwed both ends for iron pipe 15mm bore dia, complete all as specified and directed.
S&F in repair Bib taps, 15 mm bore dia, cast copper alloy fancy type chromium plated fixed in repairs complete all as specified and directed.
S&F in repairs Vitreous china wash basin, white flat back, size 550 x 400 mm including waste pipe , brackets, cutting for and pinning in ends of brackets or errecting stand and 32 mm dia PVC waste pipe fixed in repair including CP waste copling 32mm size full thread complete all as specified and directed.
S&F 15mm bore dia pillar cock fancy type, screwed down high pressure with or without letters hot or cold with long screwed shank and fly nuts screwed for iron pipe ISI marked, fixed in repairs complete all as specified & directed.
S&F in repair towel rail CP 600 mm long complete all as specified and directed.
S&F in repair 125mm CP Shower rose with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass of 12cm wide with chromium plated brackets guard & railing 60cm long, complete all as specified & directed.
S&F Liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 105 gms), complete all as specified & directed.
S&F in repair Vitreous China squatting pan of orissa pattern, size 580x440mm white with CI ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern (including fixing of flush pipe) including provision of cement concrete bedding, in repair complete all as specified and as directed.
S&F in repair Vitreous China wash down water closet pan (pedestal patters), white complete including fixing to trap, including supply and fixing of PVC seat cover for pedestal pan complete all as specified & directed.
M&L for PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation filling and mass concrete (sunken floors etc.) complete all as specified & directed.
S&F in repair PVC flushing cistern 10 ltr capacity including PVC connection inlet and and outlet connections, brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC complete all as specified & directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. Make:Paryag/Polytech
S&F in repair CI floor trap 75 mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with or without hole for waste pipe complete all as specified & directed.
Extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc. all as specified.
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove all loose dust, dirt etc complete all as specified and directed.
M&L for Industrial grade matt finish type-V, thickness 10mm floor tile of size area exc 0.18 Sqm but not exc 0.36 Sqm, set and jointed in neat cement slurry and pointed in clolured epoxy grout to match, laid over and including 15mm thick bedding layer of mortar in 1:4 (surface finished even and rough to receive tile) complete all as specified and directed.
All as per item 86 but as in skirting and like over and including 10mm thick bedding layer of mortar in 1:3.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, Bracke sketch fitting, ceiling roses, lamp holders, brackets, pendants, regulators, sockets, light fitting etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L Point wiring with 3x1.5 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multistranded copper conductor cable (Phase, neutral and earth) 1100 Volts grade drawn through and incl PVC rigid concealed conduit (ISI Marked) of suitable size with all accessories having thickness not less than 1.8mm incl sheet steel/ GI terminal box of adequate size having thickness not less than 2mm including 3mm thick hylem/masonite sheet. Earth conductor shall be connected to common earth dolly complete all as specified and directed for one light/fan point controlled by 5 Amp one switch 5 Amp. Note: 1. Connections of cable with MCBs/Switch Sockets shall be done through proper size copper/brass thimbles. 2. Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible. 3. Proper colour code will be used for wiring as per the electrical rule and as directed.
All as per Srl item No 89 here-in-before but for one 5 pin 5 Amp socket outlet point on same board
All as per Srl item No 89 here-in-before but for one 5 pin 5 Amp socket outlet point on inependent board
All as per Srl item No 89 here-in-before but using 3x2.5 Sqmm (nominal area) multistranded copper conductor cable for one 6 pin socket outlet 15 Amps
S & F switch piano flush button single pole one way 5 amp 240 volts complete all as specified and as directed.
S & F Socket outlet 2 in 1, 3 pin, 5 amps, flush type, 240 volts complete all as specified and as directed.
S & F switch 15 Amps, flush type with shutters, 240 volts all as specified and as directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type, 240 volts complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type Socket type on the existing phenolic laminated sheet etc. not less than 100 W flush typecomplete all as specified and as directed.
S&F ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals complete all as specified and as directed.
S&F Lamp holder jumbo type, PVC/Polycarbonate type with back plate incl 15W LED lamp complete all as specified and as directed.
Taking down carefully unsv copper/aluminium sub main wiring of any size including old broken steel/PVC conduit and removing materials to store for keeping in safe custody for taking credit complete all as specified and as directed.
S&F in replacement sub Main Wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit complete and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface all as specified and directed.
Supply and fixing LED tube lights fitting 1x20W, 220V,AC white poder coated CRCA box type channel with decorative end cap alongwith LED T8 tubular lamp 20W linear with extruded aluminium/pc body and PC diffuser and inbuilt drive incl connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make - Crompton Cat Pt No DMLN1LT8-16(Channel) and Cat Pt No LTT8-20(Rod) or Wipro product code P08120 or equivalent in Havells, philips, Bajaj
Supply and fixing 5 star rated BLDC ceiling fan 230 volts, single phase of 1200mm sweep double bearing type including down rod, canopy cover etc and connecting with 3 core FRLS flexible copper conductor cable of 0.50 sq mm including writing of MES No with black enamelled paint complete all as specified and directed.
S & F in replacement SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC having copper bus bar of rating 200Amps complete all as specified and directed.
S&F MCB SP 240V, 50Hz, 10 KA,of rating 6 to 32 Amp all as specified and directed.
S&F in replacement MCB SPN 240V, 50Hz, 10 KA,of rating 32Amp all as specified and directed.
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 83,784.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
M/S CANTILEVER ENGINEERS
dadwal engineers
v k engineers and builders
M/S DUGGAL CONSTRUCTION CO
M/S NARESH KUMAR SHARMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .