Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94.1 LAccepted-AOC C141 SUN CITY SECTOR 35 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹1.1 Cr+₹17.5 L (18.4%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
15 Apr 2021, 4:00 pmClosed
BP Sharma
PHED No 2 Rohtak
Construction of raw water sump well, Pump chamber, boundary wall, CC roads, laying the rising main internal distribution lines, Providing Household tap connections. Supply, erection, testing commissioning of Raw water and clear water pumping machin
2021_HRY_167342_1
Water supply scheme Bharan and Sekhpur under JJM
Open Tender
Civil Works
Works
270 days
Rohtak
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹1.6 L
17 May 2021
3 Apr 2021
15 Apr 2021
3 Apr 2021
15 Apr 2021
3 Apr 2021
Amount
RAW WATER PUMPING MACHINERY Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame RAW WATER PUMPING STATION2900 LPM X 20 M. Head
WATER WORKS 1500 LPM X 12.5 M. Head
CLEAR WATER PUMPING MACHINERY Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame WATER WORKS1500 LPM X 45 M. Head
B/STN.SHEKHPUR TITRI 800 LPM X 45 M. Head
PANEL BOARDS FOR MOTORS Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items For 2 no Pumping Sets of 2900 LPM x 20 m Head a) Main switch 63 amp. 1 No. (L&T Siemens, ABB) b) CT 100/3 = 3 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No.d) SPP = 1 No. of approved make e) Motor starter, Star delta for 2900 LPM x 20 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 3 Nos. of approved make.g)Capacitor KVAR as per site requirement = 1 No.h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
For 2 no Pumping Sets of 1500 LPM x 12.5 m Head a) Main switch 63 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T)c) Digital Multi function meter = 1 No.d) SPP = 1 No. of approved make e) Motor starter, Star delta for 900 LPM x 12.5 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
For 2 no Pumping Sets of 1500 LPM x 45 m Head a) Main switch 63 amp. 1 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 1500 LPM x 45 m Head = 2 Nos (L&T Siemens, BB)f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
For 1 no Pumping Sets of 800 LPM x 45 m Head a) Main switch 63 amp. 1 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 800 LPM x 45 m Head = 1 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each)
Supply, erection, fixing & testing of DI Double flanged pipe complete with all jointing materials 100 mm i/d
Supply, erection, testing & commissioning of IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respevts with accessories like thimble etc.10mm2 3core
25mm2 3core
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete in all respect.
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect.
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification.
Supply erection testing of reputed make LED light 100 wats with fittings and accessories complete in all repects. ( 2 at P/Stns)
Supply erection, testing & commissioning of light fittings including complete wiring alon with all material upto 10 points including switch, button, plug, PVC conduict pipe & copper wire etc. as per approved specifications. ( 1 no. pump chambers of P/Station)
Design, Supply & Erection of copper wound outdoor type Transformers of required KVA as mentioned below on load tap changer of suitable capacity on higher side of standard make outdoor type, G.O. Switch, H.T. Metering Panels, entire cable network from G.O. Switch to H.T. Metering equipment and from H.T. Metering to Transformer Main to L.T. Panel, Earthing, safety equipment and any other contingent thereto complete in all respect as per DNIT and getting it passed from Chief Electrical Officer.At raw water pumpimg pumping station = 63 KVA
Design, Supply & Erection of silent DG Sets of required KVA as mentioned below suitable capacity on higher side capacity with Acoustic Canopy, AMF Panel and Copper Earthing of suitable rate with change over switch & synchronizing panel complete as per DNIT including operation & Maintenance of 5 Years.At raw water pumping station = 30 KVA
Providing & fixing in position GI elbow ISI marked complete in all respect 15 mm i/d
Providing & fixing in position GI Nipple ISI marked complete in all respect 15mm x150mm /100 mm
Providing & fixing in position GI Socket ISI marked complete in all respect 15 mm i/d
Operation & maintenance for the complete scope of work mentioned in the DNIT (Disinfection material will be supplied by the PHED) as per schedule-IV during Defect liability period of 12 months after trial run period of 3 months & 5 years thereafter. (Will be charged to A/mtc estimate)."Defect liability period (Operation only)
Operation & maintenance during 1st year
Operation and maintenance during 2nd year
Operation and maintenance during 3rd year
Operation and maintenance during 4th year
Operation and maintenance during 5th year
Bidder Name
Amount
Lalit Kumar(GSTN-06ALGPB5309Q1ZY)
SAT NARIAN(GSTN-NA)
SAT NARIAN
SAT NARIAN
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .