Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | ₹35.5 L Quoted ₹36.3 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹44.1 L+₹7.8 L (21.6%)Rejected-Finance | ₹44.1 L+₹7.8 L (21.6%) | L2 | Rejected-Finance NOT THE LOWEST BIDDER |
| 3 | L3₹45.9 L+₹9.6 L (26.4%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | ₹45.9 L+₹9.6 L (26.4%) | L3 | Rejected-Finance NOT THE LOWEST BIDDER |
| 4 | L4₹46.6 L+₹10.3 L (28.4%)Rejected-Finance AT ROAD TINSUKIA HIJUGURI BASH BARI P O HIJUGURI DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | ₹46.6 L+₹10.3 L (28.4%) | L4 | Rejected-Finance NOT THE LOWEST BIDDER |
| 5 | L5₹47.1 L+₹10.8 L (29.8%)Rejected-Finance | ₹47.1 L+₹10.8 L (29.8%) | L5 | Rejected-Finance NOT THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | STANDARD ELECTRIC WINDERS L3 | M/S R D CONSTRUCTION L4 | FREEZCON L6 | BHABANANDA DOLEY L1 | boruah construction L2 | M H KHAN L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed. | 325 | Sqm | 33 ₹10,725 | 44 ₹14,300 | 52 ₹16,900 | 24 ₹7,800 Lowest | 35 ₹11,375 | 45 ₹14,625 |
| 2.00 | S&F for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed | 300 | Sqm | 1,064 ₹3,19,200 | 1,077 ₹3,23,100 | 1,120 ₹3,36,000 | 680 ₹2,04,000 Lowest | 1,030 ₹3,09,000 | 1,090 ₹3,27,000 |
| 3.00 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed | 25 | Sqm | 1,015 ₹25,375 | 1,072 ₹26,800 | 1,100 ₹27,500 | 680 ₹17,000 Lowest | 1,020 ₹25,500 | 1,090 ₹27,250 |
| 4.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed | 15 | Qtl | 708 ₹10,620 | 718 ₹10,770 | 733 ₹10,995 | 4,000 ₹60,000 | 700 ₹10,500 Lowest | 726 ₹10,890 |
| 5.00 | S&F for Joist, channel, angle, or tee sections of Fe 290 (Gde E-165) fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed. | 600 | Kgs | 140 ₹84,000 | 144 ₹86,400 | 155 ₹93,000 | 96 ₹57,600 Lowest | 130 ₹78,000 | 145 ₹87,000 |
| 6.00 | M&L for Rolled sections of Fe-410- W(Gde- E-250) quality- B as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed. | 400 | Kg | 162 ₹64,800 | 165 ₹66,000 | 172 ₹68,800 | 96 ₹38,400 Lowest | 150 ₹60,000 | 165 ₹66,000 |
| 7.00 | M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (gde-E-250) quality -A complete all as specified and as directed. | 500 | Kg | 162 ₹81,000 | 165 ₹82,500 | 172 ₹86,000 | 96 ₹48,000 Lowest | 150 ₹75,000 | 165 ₹82,500 |
| 8.00 | S&F for Joist, channel, angle, or tee sections of Fe 290 (Gde E-165) fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed. | 400 | Kg | 140 ₹56,000 | 144 ₹57,600 | 155 ₹62,000 | 96 ₹38,400 Lowest | 130 ₹52,000 | 145 ₹58,000 |
| 9.00 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed. | 385 | Sqm | 47 ₹18,095 | 50 ₹19,250 | 55 ₹21,175 | 40 ₹15,400 Lowest | 40 ₹15,400 Lowest | 50 ₹19,250 |
| 10.00 | M&L for Anodised aluminium snap grid size 605 X 605 mm frame work for false ceiling complete all as specified and as directed | 300 | Sqm | 622 ₹1,86,600 | 631 ₹1,89,300 | 645 ₹1,93,500 | 280 ₹84,000 Lowest | 600 ₹1,80,000 | 638 ₹1,91,400 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
11 Oct 2025, 6:00 pmClosed
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
SPL REPAIR TO BLDG NO T 01 AND SPL REPAIR REPLACEMENT OF ROOM NO 10 12 13 14 AND 15 OF OLD SIGNAL CENTRE AT DINJAN MIL STN UNDER GE DINJAN
2025_MES_730941_1
84507/E8
Open Tender
Civil Works
Item Rate
180 days
GE DINJAN
AAS PER TENDER DETAIL
8 documents required · 8 mandatory
₹500
GE DINJAN
₹87,000
Yes
3 Jan 2026
15 Sept 2025
17 Oct 2025
15 Sept 2025
11 Oct 2025
29 Sept 2025
Amount
Dismantling of Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
S&F for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
S&F for Joist, channel, angle, or tee sections of Fe 290 (Gde E-165) fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed.
M&L for Rolled sections of Fe-410- W(Gde- E-250) quality- B as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed.
M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (gde-E-250) quality -A complete all as specified and as directed.
S&F for Joist, channel, angle, or tee sections of Fe 290 (Gde E-165) fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
M&L for Anodised aluminium snap grid size 605 X 605 mm frame work for false ceiling complete all as specified and as directed
S&F for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed
M&L for 6 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation and acoustic purpose fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and as directed
M&L for 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work and fixed with wooden beading complete all as specified and as directed.
Taking down the Chowkhats or frames not exc. 1.5 sqm each (without taking off shutters from the frames) complete all as specified and as directed
Taking down the Chowkhats or frames exc 1.5 sqm but n exc 4 sqm each (without taking off shutters from the frames) complete all as specified and as directed
S&F for Pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and as directed.
S&F for Pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and as directed.
M&L for 35 mm thick IInd Class Hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete as specified and directed.
S&F 35mm thick, glazed/skelton shutters with second class hard wood,open rebated and prepared to receive glass, gauge, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, sizes of members of shutter as specified in SSR Part I Section 8, clause 8.24 (a) complete as specified and directed.
S&F 30mm thick, glazed/skelton shutters with second class hard wood,open rebated and prepared to receive glass, gauge, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, sizes of members of shutter as specified in SSR Part I Section 8, clause 8.24 (a) complete as specified and directed.
S&F for Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F for 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed.
S&F for Factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing in SSR Part II 2010 complete all as specified and as directed
S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing in SSR Part II 2020 complete all as specified and as directed
M&L for Preparation of new or untreated surfaces of wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over pink primer complete all as specified and as directed.
M&L for Preparation of old painted surfaces of wooden surface of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for painting steel and iron surfaces of steel surfaces of any description, over 10cm in width or girth, not otherwise described, applying two coats of synthetic enamel paint over coat of red oxide primer including preparation of new surface complete all as specified and directed
M&L for Preparation of old painted surfaces of steel and iron surfaces of steel surfaces of any description, over 10cm in width or girth, not otherwise described, applying one coat of synthetic enamel paint complete all as specified and directed
S&F for mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Dismantling of unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and as directed.
Dismantling of framed timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed.
M&L for Second class hard-wood in scantlings wrought timber fixed complete all as specified and as directed
M&L for 2nd class hardwood exc 6 n.exc. 13 Sqcm Plain fillets of square, rectangular or triangular in section, clean sawn, se-cured with nails or brads complete all as specified and as directed.
M&L for taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement Mortar in 1:4 using water proofing compound in top layer (Water Proofing Compound measured separately) and finished even and smooth (without using extra lime or cement) complete all as specified and directed.
M&L for rendering 10 mm thick internal wall on fair faces of brick work or concrete surfaces in cement Mortar in 1:6 and finished even and smooth (without using extra lime or cement)complete all as specified and directed.
Supply only Liquid water proofing compound for external wall plastering (for 5 mm thick plastering) complete all as specified and directed
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and as directed.
M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and as directed.
M&L for rendering 10 mm thick on one side of lathing in cement Mortar in 1:6 and finished even and smooth (without using extra lime or cement) complete all as specified and directed
M&L for rendering 15 mm thick on other side of lathing in cement Mortar in 1:4 using water proofing compound in top layer (Water Proofing Compound measured separately) complete all as specified and directed
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of walls by brooming down or steel wire brushing, scraping down with steel scraper, smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper-oil-emulsion over a coat of primer including two coat wall care putty complete all as specified and as directed.
M&L for preparing old plastered surfaces of walls by washing, rubbing down and scraping of existing distempering/painted surfaces etc and applying one coat of distemper oil emulsion complete all as specified and as directed.
M&L for preparation of new plastered surface of walls etc and applying two coats of cement base paint over alkali resistant priming paint complete all as specified and directed
M&L for preparation of old decorated plastered or unplastered surfaces of wall cornices etc by brooming down or steel wire brushing, scraping down, the surfaces covered by smoke soot, growth of moulds and moos, efflorescent, having oil and gresase spots and applying one coat of cement base paint (white or tinted) complete all as specified and as directed
M&L PCC 1:2:4 type B0 (using 12.5 mm graded aggregate) as in hold fast and filling of steel chowkhat etc. complete all as specified and directed
S&F for mild steel flat iron as in hold fast 25x6 mm confirming to Fe290 Gde E-165 complete all as specified and directed
Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in sub base of floor or plinth protection, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed
M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified and as directed
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed
M&L for 40 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) in sub base finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed
M&L for light shade vitrified Ceramic tiles 10 mm thick (Square/rectangular) polished, area of each tiles exc 0.36 sqm but n exc 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed in CM 1:6 complete all as specified and directed.
M&L for light shade vitrified Ceramic tiles 10 mm thick (Square.rectangular) polished, area of each tiles exc 0.36 sqm but n exc 0.42 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick backcoat in CM 1:4 complete all as specified and directed.
M&L for Coloured Glazed ceramic tiles in vertical surface of size 450X 300X 7 mm thick over 10 mm thick back coat of cement mortar in 1:4 set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
S&F 100 mm long Butt hinges, medium weight, cold rolled mild steel fixed to Chowkats complete all as specified and directed
S&F Aluminium Handle 150 mm long cast type, anodised extruded fabricated type complete all as specified and as directed.
S&F Aluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F for 375 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
S&F in repairs110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed
S&F for 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed
S&F for 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed
S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed
S&F GI steel water tubing 15mm bore medium grade with all fittings and fixed complete to walls ceiling or laid in floors complete all as specified and as directed.
S&F GI steel water tubing 20mm bore medium grade with all fittings and fixed complete to walls ceiling or laid in floors complete all as specified and as directed.
Dismantling of water tank Capacity exc 500 not exc 1000 Ltrs and removing to store complete all as specified and as directed
Hoisting and Fixing of rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position specified in SSR Part I complete all as specified and as directed.
S&F for 20 mm bore, Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S&F for 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed
S&F for Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S&F in repairs PVC low level flushing cistern 10 litre capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC conection pipe and flush pipe of polyethylene of low or high density or PVC. 32 mm dia complete all as specified and directed
S&F in repairs vitreous china wash hand basin white flat back size 550x400mm excluding taps, waste chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed.
S&F in repairs for PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and as directed
M&L PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement including disconnection of old existing trap, and connected with existing water pipe complete all as specified and directed.
S&F for Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed
Demolition of brickwork or stone/ boulder masonry, built in Cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar in 1:4 complete all as specified and as directed
S&F for Tubular towel rail, 20mm dia, D type, 60cm long Brass Chromium plated between flanges complete all as specified and as directed
S&F in repairs soap dish vitreous china coloured approximate size (160mmx160mmx90mm) complete all as specified and as directed.
S&F in repair pillar taps of size 15mm, chromium plated fancy type cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed.
S&F for Brass chromium plated shower rose 125 mm size fixing to steel pipe or union complete all as specified and as directed
S&F in repairs for bib taps fancy type CP with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule and fixed of size 15mm bore in repair complete all as specified and as directed.
S&F in repairs 15 mm bore dia cast copper alloy fancy type, chromium plated stop valves, crewed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs 15mm stop valves (concealed type), cast copper alloy fancy type chromium plated, long sunk and cup, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F for Anodised aluminium ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including frosted glass pane, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed
S&F 15mm dia Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) complete all as specified and as directed.
M&L for 32 mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed.
S&F in repair 15 mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and as directed.
M&L for 20 mm thick Granite (of any type) work (table rubbled and polished) in steps, Jambs, Pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm screed complete all as specified and directed
M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick back coat of cement mortar in 1:4 complete all as specified and as directed
M&L for chequered cement concrete tiles 20cmX20cmX25mm thick, set, joined and pointed in neat cement slurry in floors with grey cement and pigment over 15 mm thick screed bed CM 1:4 complete all as specified and directed.
M&L for 25 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) in sub base finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed
S&F 5mm thick printed colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site. Complete all as specified and as directed.
M&L for taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for preparing old decorated surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of primer including two coat wall care putty complete all as specified and as directed.
M&L for preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed.
Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets,sunken type box etc.and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification complete all as specified and as directed.
Taking down carefully MCB DBs any type and size by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and keeping it in MES store for safe custody complete all as specified and as directed.
Material and labour for point wiring for the followings with 1.5 Sqmm single core, PVC FRLSH insulated unsheathed, multistranded copper conductor drawn through and including PVC casing caping including necessary accessories like bends, tees, PVC square and elbow etc fixed on wall/ceiling with 1.5 Sqmm PVC FRLSH insulated unsheathed multi stranded copper conductor cable as earth conitinuity (green in colour) connected to common earth dolly including modular PVC flush box and modular face plates for One light/fan point controlled by one,one way switch complete all as specified and as directed. (Note:-(1) Rate for fixing and making good the existing surface for complete casing caping wiring is deemed to be included in quoted rate).
Description all as per Ser item No. 115 here-in-before but One 3 Pin 5 Amps socket out let point on independent board.
Description all as per Ser item No. 115 here-in-before but One 3 Pin 5 Amps socket out let point on same board alongwith other suitable switchs.
Description all as per Ser item No. 115 here-in-before but using 2.5 sqmm PVC FRLSH insulated copper condutor wire for connecting 15A socket on independent board.
Description all as per Ser item No. 115 here-in-before but using 4 sqmm PVC FRLSH insulated copper condutor wire for connecting 15A socket on independent board.
Description all as per Ser item No. 115 here-in-before but using 6 sqmm PVC FRLSH insulated copper condutor wire for connecting 15A socket on independent board.
Supply and fixing of modular switch one way 6 amps 1 module 240 Volts complete all as specified and as directed.
Supply and fixing of modular socket outlet 2/3 pin 6 Amps 240 volts 2 module complete all as specified and as directed.
Supply and fixing of modular socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and as directed.
Supply & fixing of modular switch one way 16 Amps 1 module 240 Volts complete all as specified and as directed.
S & F Switch socket combination 2 in 1, 5 Amps, flush type 240 volts complete all as specified and directed.
S & F Switch socket combination 5A/16A, 5 in 1, 240 volts, flush type complete all as specified and directed.
S & F Lamp holder, insulated body with back plate suitable for batten fittings all as specified and directed.
S&F modular bell push switch 6A 1 module all complete complete all as specified and as directed.
Supply & Fixing of ceiling fan step modular step regulator, 120W, 2 module all as specified and as directed.
Supply and fixing of bell electric, ding dong type 240 Volts, single pole complete all as specified and directed.
Supply and fixing angular/batten holder PVC/Polycarbonate suitable for batten fittings including one inverter LED Lamp of 9W complete all as specified and as directed.
Supply and fixing of ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals complete all as specified and as directed.
Supply and fixing LED batten intverter type(1.2m) made of aluminium sheet housing with PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumen at a minimumsystem efficiency of 115 lumen per watt and total power consumption not more than 18/20 W iincluding driver. It has a rated system life time of 40000 burning hour at L70 and should have a colour temperature of 6500K, CR>80 , THD < 10 % and PF>0.95 complete all as specified and as directed.
Supply and fixing LED batten inverter type(2 ft) made of aluminium sheet housing with PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumen at a minimumsystem efficiency of 115 lumen per watt and total power consumption not more than 8/10 W iincluding driver. It has a rated system life time of 40000 burning hour at L70 and should have a colour temperature of 6500K, CR>80 , THD < 10 % and PF>0.95 complete all as specified and as directed.
Supply and fixing LED Bldg light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete as specified/directed.
S&F Bldg light bracket fabricated out of GI Tubing light grade 32 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron size 40X5mm of suitable length 02 pairs incl nut bolts etc of suitable size, including taking down old corroded one all as specified and directed.
Supply and fixing of recess mounted 40 watt LED flat panel 2 x 2 made of CRCA sheet steel housing duly powdercoated with high efficient LEDs & glare free full opal diffuser, including all other accessories ,IP-20 including testing and commissioning of including testing complete all as specified and as directed.
Supply and fixing in repair of MCB Distribution board TPN 4 Way for mounting SPN/ SP/TPN/TP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and as directed.
Supply and fixing in repair of MCB Distribution board SPN 8 Way for mounting SPN/ SP MCBs as Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet , fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement. The DBs shall be of IP 43 - IK 09 with metal door complete all as specified and as directed.
Supply & fixing in repair 415 Volts 10KA 'C' curve miniature circuit breaker(MCB) TPN 63 AMP in the DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, DP in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.
Supply & fixing in repair of MCB SP 6-32 Amps 'C' Series 10 KA, 240 volts complete all as specified and as directed.
Supply & fixing in repair of MCB SPN 6-32 Amps 'C' Series 10 KA, 240 volts complete all as specified and as directed.
Supply and fixing ceiling fan with blades, down rods, electric regulator and accessories 230V, 1200mm sweep, Min air delivery 210 CFM with service value 6.00 BEE five star star rated with brushless direct corrent mortar inlcuding taking down old ceiling fan and returned to store complete all as specified and directed.
Supply & fixing Exhaust fan, steel body AC single phase 230V of size 300mm sweep with blades and frame and louvers complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised wire of dia 4 mm as earthing lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execuation and eath works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking out the old earthing material complete all as specified and directed. Note : No extra payment will be for the earthing GI wire of size 4 mm dia.
Material & labour for Sub main wiring with two runs of single core 6 Sqmm (Nominal Area) FRLSH PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh and including PVC casing caping of adequate size fixed on surface of wall/ceiling with all necessary fittings and accessaries and 1 run of FRLSH PVC insulated and unsheathed insulated single core cable with multi standered copper conductor of size 6 Sqmm as earth wire (green in colour) run through PVC Conduit and connected common earth dolly including taking out the old sub main wiring for connection to DBs/dolly shall be deemed to be included in this item and Two runs of 6 Sq mm as current carrying conductor and one run of 6 Sq mm as earth conductor PVC conduit shall be measured as one run for measurement, complete all as specified and directed.
Taking down and Supply and laying and testing cable, XLPE insulated,screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed.
Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.
S&F of concrete cable cover, class EHV,Class LV, Type I, flat, size 250 mm x 150mm x 40mm ® laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
Supply & fixing of Tubes, 'light grade' galvanised 50mm bore, with all fitting and fixed complete to walls and ceilings or laid in floors to run cables through them for its protection including all the accessories required, complete all as specified and as directed.
Boring under without disturbing the top surface of the road for passing through GI protection pipe 50mm bore, not exceeding 10m in single length complete all as specified and as directed. Note: Necessary infrastructure required for boring shall be arranged by the contractor at his own cost.
boruah construction (BID ID -3442154)
STANDARD ELECTRIC WINDERS (BID ID -3448405)
M/S R D CONSTRUCTION (BID ID -3448444)
M H KHAN (BID ID -3448157)
FREEZCON (BID ID -3448532)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .