Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹28.9 L+₹89,396 (3.19%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹36.9 L+₹8.9 L (31.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹27.1 L
EMD Value
₹54,300
Closing Date
23 Dec 2022, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
as per tender documents
2022_MES_555391_3
CWE/MTR/BPR/ OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
as per NIT
7 documents required · 7 mandatory
₹500
GE Bharatpur
₹54,300
Yes
16 Jan 2023
2 Dec 2022
26 Dec 2022
2 Dec 2022
23 Dec 2022
9 Dec 2022
Amount
Excavating over areas n.exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas, exc 1.5m to 3.0 m in depth; for foundation etc,or for shafts, wells, ceasspits, manholes, pier holes, etc.n.exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft / losse soil complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC, M-15 type B-2 (using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
M&L for cement concrete (1:3:6) types C-2 (40mm graded crushed stone aggregates) as in surface channels and drains complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soft/ loose soil complete all as specified and directed.
Removing excavated soil / material to a distance not.exc. 50m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed.
M&L for reinforced cement concrete M-30 (design mix) (20mm graded aggregate) as in foundations including rafts, footings, beams, plinth beams, bases for columns etc, basement slabs under reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete M-30 (design mix) (20mm graded aggregate) as in walls of water tnak etc complete all as specified and directed.
M&L for reinforced cement concrete M-30 (design mix) (20mm graded aggregate) as in Beams, cantilevers, bressummers lintel over 1.5m span & similar RCC works complete all as specified and directed.
M&L for reinforced cement concrete M-30 (design mix) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work etc not exc 200 mm thick (horizontal or slopping) for fair finished surfaces of concrete complete all as specified and directed.
M&L for formwork to sides of pillars, post, columns and similar items square, rectangular or polygonal surface of concrete with rough finished surfaces complete all as specified and directed.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc vertical or to batter fair finished surfaces of concrete flat complete all as specified and directed.
M&L for formwork to side and soffits of floor or roof beams, lintels, cantilevers shelves including supports, overhangs, etc also splays between floors and beams, etc for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for Formwork to edges of concrete flats, treads breaks in floors, window cill concrete railling, opening in concrete walls floor and roof n.exc 20 cm wide and sides RCC / PCC band in walls horizontal and sloping and similar work with fair finished surface exc 10cm but not exc 20cm wide complete all as specified and directed.
M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L mild steel TMT steel bars as in reinforcement 5mm dia and over upto and including 10mm dia as in stirrups cut to length bent to shape required including cranking, bending spirally for columns, hooking ends and binding with and including mild steel (wire) annealed not less than 0.9mm dia complete all as specified and directed.
M&L for 10mm thick rendering in cement mortar (1:3) on roof / concrete surfaces reinforced with chicken wiremesh of galvanised steel wire of 1.2mm dia and mesh size 12mm mixed with WPC @ 3% by the weight of cement used and finished even and smooth without using extra cement with leak proof testing complete all as specified and directed. Note : WPC will be measured and paid separately item No 23.00.
M&L 10mm thick rendering in CM (1:3) on concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of exterior emulsion paint, Apex ultima of Asian Paints or equivalent as approved over a coat of alkali resistant primer complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-2 (Using 40mm graded crushed stone aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 40mm average thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in floor / padding finished the surface even and smooth without using extra cement complete all as specified and directed.
S&F for anodised aluminium frame for ladder with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
M&L precast cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in manholes cover including placing and set in cement mortar (1:6) complete all as specified and directed.
M&L for 100mm bore cast iron pipes with spigot and socket ends centrifugallycast class B in any length laid in trenches complete all as specified and directed.
M&L for nitobond (Forsoc) coating over concrete surface complete all as specified and directed.
S&F PVC coated rung size 265x165x25 mm complete all as specified and directed.
M&L for applying waterbar as in joint of RCC concrete surface complete all as specified and directed.
S&F 100 mm bore cast iron vent pipe minimum 1.80 mtr long with CI bend with one end fixed mosquitoproof wire mesh fitted with 40x3 FI clamp complete all as specified and directed.
Cleaning the surface thoroughly to make it free from dirt, dust etc and remove loose damaged concrete from the surface complete all as specified and directed.
M&L for skim coat to maintain profile of structural members by using latex B2 modified air cured mortar system prior to fiber wrapping cement 1:3 part graded cleaned repacked river sand 5 to 10% latex mortar by weight of cement 0.5 without ratio upto 10mm thickness including leveling profiling etc complete all as specified and directed.
M&L for carrying out water proofing treatment on underground water tank as per standard practice and details given below ensuring safety in all respect. Supply and application of two coats of SE EC/UV two compound cementations coating of entire prepared surface (consumption will be 1.5 to 2 Kg/M2) using soft bristle brushes and rollers and as per OEM recommendations carrying out suitable treatment for existing adjoin structures as per standard practice (as mentioned in SLA) carrying out all related works without any damage to the existing installations etc. complete all as per site requirement and to the satisfaction of Engineer-in-Charge.
Supply, install, testing & commissioning open well submersible mono block pump set 3 phase, 415V, 50 Hz copper wound of capacity 10 HP with cast iron impeller and stainless steel shaft with 36 to 40 mtr head with discharge in LPM from 400 to 800 complete all as specified and directed. KOEL Model No OWH-21,Cat part No-OW1.7540.10.31 or equivalent item of other specified make.
Supply, install, testing & commissioning submersible mono block pump set 3 phase, 415V, 50 Hz copper wound of capacity 05HP with cast iron impeller and stainless steel shaft with 120 to 180 mtr head with discharge in LPM from 50 to 130 complete all as specified and directed. KOEL Model No- H4112, Cat part No-KEP.3427.05.3.01 or equivalent item of other specified make.
S&F of open well submersible starter box suitable for 10 HP capacity, 415V, 50Hz, complete fixed in wall complete all as specified and directed
S&F of submersible starter box suitable for 05 HP capacity, 415V, 50Hz, complete fixed in wall complete all as specified and directed.
S&F of Nylon rope of 20 mm dia with first quality suitable for hanging of submersible pump with MS stand complete bind with GI wire all as specified and directed.
Material and labour submersible flat cable of 6 sqmm, 3 core copper conductor cable suitable for 10 HP pump motor complete connection from starter panel to motor all as specified and directed.
Supplying, laying, jointing, testing and commissioning of LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade of following sizes 25 Sqmm, 4 core and laid in trenches/pipe or fixed on wall/pole complete all as specified and directed.
Supply and laying 150mm bore ductile iron pipe single socketed with tyton joints Class K-7 confirming to IS-8329/2000 Centrally cast spun ductile iron pressure with spigot ends in any length including jointing and testing complete all as specified and directed. Note : DI fittings and joints shall be measured and paid for separately under respective item of BOQ.
M&L for Ductile iron fitting such as bends (any type radius and angle) taper any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces, single branch "Y" Junction, double branch cross (all socketed or socket and spigot) collars caps and plugs upto 150mm dia complete all as specified and directed.
S&F in replacement of CI Sluice valve 150mm dia both end flanged with CI wheel high tensile brass spindle including fixing arrangement class PN-1.6 suitable for 150mm bore MS Pipe with all fittings such as rubber, gasket sheet, washer, nut & bolt etc complete all as specified and directed.
S&F in replacement of CI Sluice valve 80mm dia both end flanged with CI wheel high tensile brass spindle including fixing arrangement class PN-1.6 suitable for 800mm bore MS Pipe with all fittings such as rubber, gasket sheet, washer, nut & bolt etc complete all as specified and directed.
S&F in replacement of non return valve 80mm dia both end flanged with CI wheel high tensile brass spindle including fixing arrangement class PN-1.6 suitable for 800mm bore MS Pipe with all fittings such as rubber, gasket sheet, washer, nut & bolt etc complete all as specified and directed.
S&F GI tubing medium grade ISI marked including all fittings laid in trenches / fixed on wall of size 80 mm bore including scaffolding upto 25 meter staging for pipe line erection for Over Head Reservoir and saddling for pipe line with necessary arrangements complete all as specified and directed.
Cutting CI/DI pipe of size 150 mm dia and reducing to required length in position for insertion of new tees, branches, etc complete all as specified and directed
Cutting CI/DI pipe of size 100 mm dia and reducing to required length in position for insertion of new tees, branches, etc complete all as specified and directed
Cutting CI/DI pipe of size 80 mm dia and reducing to required length in position for insertion of new tees, branches, etc complete all as specified and directed
Excavation in trenches in any type soil n.exc 1.5m wide and n.exc 1.5m in depth for taking out / laying of pipe lines and getting out forming bottom surfaces to required gradients complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n.exc 25cm in any type soil complete all as specified and directed.
Removing excavated soil/material to a distance not.exc. 50m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and directed.
M&L for RCC design mix M-30 grade,(using 20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts & similar works complete all as specified and directed.
PD GUPTA AND COMPANY
M/S MAMTA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .