Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹83.7 LAdmitted-Finance SAKETPURI PO SANT KOLAMBA COLLEGE HAZARIBAG | HAZARIBAGH | JHARKHAND | 825301 | -0.10% | ₹83.7 L | L1 | Admitted-Finance |
| 2 | L2₹84.2 L+₹50,245.16 (0.60%)Admitted-Finance RAGHUKUL NEW AREA MORABADI RANCHI | +0.50% | ₹84.2 L+₹50,245.16 (0.60%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | - | Rejected-Technical Bidder substantially not responsive due to non compliance of Detailed NIT Sl. No. 12 of F2 bid document |
Tender Value
₹83.7 L
EMD Value
₹1.7 L
Closing Date
13 Apr 2026, 5:00 pmClosed
Chief Engineer
Jharkhand Police Housing Corporation Limited Line Tank Road Ranchi 834001
Construction of Toilet for 03 Nos. Barrack Part 1 at J.A.P.T.C., Padma in the district of Hazaribagh.
2026_JPHCL_111459_1
JPHCL/GR 14/NIT 09/2025-26
Open Tender
Civil Works - Buildings
Percentage
210 days
Hazaribag
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.7 L
Yes
9 Jun 2026
13 Mar 2026
15 Apr 2026
13 Mar 2026
13 Apr 2026
13 Mar 2026
Section- I Building Works
5.1.1 Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m including all lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.
5.1.2 Extra for earth work in hard soil as per specification and direction of E/I.( vide classification of soil item B)
5.1.10 Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
5.6.1 Providing designation 75 A one brick flat soling joints filles with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
5.3.1.2 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size)
5.2.3 Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
5.3.5 Providing and laying damp proof course 50mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand (zone III) : 4 graded stone aggregate 20mm nominal size).
5.1.7 Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all comp
5.2.14 Providing designation 75A brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
5.2.52 Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in CM (1:6) in super structure with approved quality of Clean coarse sand of F.M 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials raking our joints to 15 mm depth curing, taxes and royalty all complete as per building specification and direction of E/I
5.2.23 Providing designation 125mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse & of F.M. 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
5.3.1.1 Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone -III ) : 3 graded stone aggregate 20mm nominal Size)
5.3.17.1 Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete
5.3.10 R.C.C. Work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, column, pillars, piers, abutments, posts and stru etc. Above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.6 Centering and Shuttering including strutting, propping etc. And removal of form for Column, Pillars, Piers, Abutments, posts and Struts
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.19 Centering and Shuttering including strutting, propping etc. And removal of form for Weather shade, Chajja, corbels etc. Including edges
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete
5.5.5 Providing Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio
(a) 10 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )
5.5.5b 12mm dia - 20mm dia TMT Fe 500 (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel)
5.7.15 Provding 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M 1.5 with 5% cico or any other approved water proofing compound including screening curing withall leads andlifts of water scaffolding taxes and royalty all complete
5.7.3 Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
5.7.6 Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I.
DSR 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
5.7.11 Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
DSR 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
DSR 11.37A Providing and laying of 1st quality conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make, in all colours, shades, except burgundy, bottle green, black of any size.. In skirting..dado.over 12mm thick bed of cement morter 1:3(1 cement : 3 coarse sand)
DSR 9.119 Providing and fixing factory made PVC door frame of size 50x47 mm with a wall thickness of 5 mm made out of extuded 5 mm rigid PVC foam sheet mitred at corners and joined with 2 nos ofm long brackets of 15x15 mm MS squre tube the vertical
5.5.18 Supplying , fitting and fixing fully glazed steel door, windows or ventilators of standard rolled 'Z' and mullion steel sections and size as per IS - 1038 joints met and wleded with 100 x 16 x 3mm M.S. lugs fixed in cement concrete (1:2:4) blocks
DSR 9.120.2 Providing and fixing 30 mm thick factory made PVC rigid foam panelled door shutters manufactured by M/s Rajshri or equivalent made from M.S. tube of 19 gauge thickness, size 19 x 19 mm for styles and 15 x 15 mm for top and bottom rails, covered with heat moulded PVC "C" channel of 5 mm thick and 75 mm wide PVC sheets for top rail, lock rail and bottom rail on either side and 5 mm thick, 20 mm wide cross PVC sheet as gap insert for top rail and bottom rial, panelling of 5 mm thick PVC sheet fitted in the M.S. frame welded/ sealed to the styles and rails with 5 x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineer-in-Charge fixed to frames with 4 Nos. M.S. powder coated butt hinges (For W.C. and bathroom shutters).
5.8.41 Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxe
5.8.45 Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
5.8.18 Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface inluding preparing the plastered surface by rubbing wmooth with pumice stone or fine sand paper applying putty wherever required sca
DSR 13.46.1 Finishing Wall with acrylic smooth exterior paint of required shade : 13:46:1 New work ( Two or more coat applied @1.67 lit./ 10 sq.m over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm)
DSR 4.17 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand incl
5.10.34 Providing 150 mm wide brick drain in cement mortar (1: 6) with av. 150 mm. clean depth and 125 mm apron including cost of earthwork involved with 75 mm, cement concrete (1: 4: 3) over one brick designation 75A, flat soling in proper grade and slop
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
(a) Bricks (1K + 16P = 17 KM.)
(b) Local sand = 3 KM.)
(c) Coarse Sand (12 KM.)
(d) Stone Chips (30KM.)
(e) Cement (5 KM.)
(f) Steel (5KM.)
Sanitary Installation Work
DSR 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I.(Approved Brand - ASTRAL/ SUPREME)
(a) 18.8.1 15mm dia
(b) 18.8.2 20mm dia
(c)18.8.3 25mm dia
3.1.5.2 Providing and fixing 15 mm dia male ended C.I.Body brassspindle valve and seat bib cock of approved quality ( wt not less than 400gms) with extra socket all complete as per specification and direction of E/I.
DSR 18.49.1 Providing C.P brass bib cock of approved quality confirming to IS:8931
DSR 17.32.1 providing and fixing mirror of superior quality and of required shape and size. Circular shape 450 mm dia
DSR 18.65 providing and fixing PTMT dish holder having length 138mm, breadth 102mm, height of 75mm..
DSR 17.7.2 providing and fixing wash basin with CI bracket 15 mm C.P brass pillar taps , 32 mm C.P brass waste..
DSR 18.64 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
3.1.12 Providing and fixing G. M. fullway valve of approved quality as per specificiaton and direction of E/I.
(c) 15 mm dia and (wt. not less than 300gm)
(c) 20 mm dia and (wt. not less than 400gm)
(c) 25 mm dia and (wt. not less than 500gm)
D.S.R 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
3.2.1 Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'P' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, comple (c) With 10lit. low level PVC cistern
3.2.3 Suppling, Fitting and Fixing Flat Back or angular, liped front viterous wide glazed earthen were urinal of Hindustan / Parrywere or any other approved ISI marked with 5 litres capacity C.I. automatic flushing cistern of reliance for any other ISI approved make with all fittings with CI or RS Brackets, Standard Size G.I. flush pipe with fitting clams 15mm CI buddy brass spindle stop cock of approved quality weight not less than 400 grms, 15 mm PVC / alkthene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with two coats of approved paint over a primer coat of red oxide cutting wall and floor, making good the same etc. all complete as per specification and direction of E/I. (a) Flat back or standing corner (600mm x 350mm)
DSR 12.41.2 Providing and fixing on wall face unplasticised Rigid pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
DSR 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expa
12.42.3.2 Single tee with door 110x110x110 mm
12.42.4.2 Single tee without door 110x110x110 mm
12.42.5.2 110 mm bend with door
DSR 12.42.1.2 Coupler 110 mm
3.2.11 Making holes in walls for laying H.C.I./ P.V.C Pipes and restoring the same after pipe laying as per specification and direction of E/I.
(a) 125mm thick
(b) 250mm thick
DSR 19.6 Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete.
DSR 19.6.2 150 mm dia R.C.C. pipe
D.S.R. 19.30 Constructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 19.30.1.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
D.S. R. 18.75.1 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour
SEPTIC TANK & SOAK PIT
5.1.1 Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing ro
5.1.2 Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classification of soil iten _B)
5.1.10 Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as pe
5.3.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 5.3.1.3 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
5.6.1 Providing designation 75 A one brick flat soling joints files with local sand including cost of watering taxes royalty all complete as per building specefication and direction of E/I
5.2.2 Providing designation 75A brick work in C.M (1:4) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curri
5.2.23 Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.20 Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick
5.3.11 R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size)
5.3.17.21 Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
5.7.2 Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
5.7.11 Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Basic Rate of SOR 2022 M-198 (page no 55) Providing and laying brick bats in soakpit with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I.
5.5.4 Providing Tor steel reinforcement of 8 mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complet
5.5.5 Providing Tor steel reinforcement of 10mm , 12mm & 16mm dia rods as per approved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in positio
(a) 10 mm TMT bar FE 500 ( Only Valid for SAIL & TATA Steel )
DSR 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.2 110 mm diameter
Basic Rate of DW & SD SL NO 31(b) M 947 Supplying, fitting and fixing C.I. cover with frame for mane hole and inspection chamber with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I. (a) Size 600 x 450 mm (Wt. 25 Kg).
Carriage of materials by truck or by any mechenical means loading,unloading & stacking etc. all complete job as per direction of E/I.
(b) Bricks (1K + 16P = 17KM.)
(c) Coarse Sand (12KM.)
(d) Stone Chips (30 KM.)
(e) Cement (5 KM.)
(f) Steel (5 KM.)
Section III 200x150xmm dia Deep bore Well With Pump set & electrification etc works.
WD & SD Basic rate item no. 119 M 1035 Suppling all materisls labour and tools and cost of drilling 200mm x 165mm bore well in all kinds of soil and rock in rural area for installation of pump set with hydrolic DTH rig machine, all complete including suplying all materials tools, drilling rig, Air compressor and equipments, as well as fuel, lubricants and cost of transprtation of Rig machine and other vehicles up to the site.
From 0.0M to 50.0 M belew G.L
From 51.0 M to200.00 M belew G.L
DW& SD Basic rate item no. 120 M 1036 supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe itc including all taxes, VAT, Excise duty, freight charges with inspection charges etc as applicable, etc all complete job.
DW& SD Basic rate item no. 126 M 1042 Cleaning Flushing and devloping of drilled hole for testing the discharge of water development of bore well by continueous flow of water bu using heavy compresser upto satisfaction of E/I. To get uniterrupted flow of water free from sand and soil etc.
DW& SD Basic rate item no. 120 M 1036 Supplying and fitting M.S cap over 200mm dia casing pipe as per direction of E/I .
WD & SD Basic rate item no. 139 M 1055 Supplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump.
Submersible Pump 150 mm dia ( with Bronze impeller) up to 8 stages 2.0 HP
WD & SD Basic rate item no. 149 M 1065 Supplying Fully Automatic Starter to operate induction motor working on 415v, 3 phase ,50 hz with no volt coil , Over load element , ON-OFF push buttons with necessary materials and connected to supply etc complete starter with original sheet steel encloser as per IS: 3914. F.A.S.D. Starter 10 HP
ED Basic rate M1627 PG-36 FR PVC insulated 3 core 4 sq.mm. copper wire.
Rate Analiysed and Approved 2no heavy duty clamp 40mm dia duitable for pipe with all complet job.
WD & SD Basic rate item no. 14(K) (v) Supplying & lowering 40mm da column G. I. pipe with all complete job.
EXTERNAL ELECTRIFICATION WORK
Note:- OF MAKE (1)PVC insuleted copper conductor wire of make:-Havell's/Polycab/Finolex/Anchor (2)PVC conduit of thiknss 1.5mm/2mm for wiring:-Polycab/ANCHOR/AKG (3) GI modular box of make -: Anchor/ Havells/Legrand/ABB (4)Switches/soket outlet for modular type:- Anchor(roma) / Havells(cabtree) / C&S/ Legrand (5)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB:Havell's/L&T/Legrand/Schneider/C&S (6)XLPE/PVC aramoured cable:-Havell's/Polycab/V-guard/Finolex (7) LED FTTING FIXTURE -: Havells/Bajaj/Crompton/C&S (Model/as per E/I ) (8) CEILING / WALL / EXHAUST FAN -: Havells / Bajaj / Usha / Polar (Model/as per E/I)
1.3 Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc.
1.3.1 Group A
1.5 Power plug wiring in PVC conduit (2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required.
1.7 Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required
1.7.2 2x2.5 sq mm+1x2.5 sq mm earth wire
1.7.4 2x6 sq mm+1x6 sq mm earth wire
1.21 S/F PVC conduit :- supplying and fixing of following sizes PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case recessed conduit as required .
1.24 S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required
1.24.1 5/6 amps, one way switch
1.24.3 15/16 amps, one way switch
1.24.4 5/6 amps, 3 pin socket outlet
1.24.5 15/16 amp 6 pin socket outlet
1.27 S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required.
1.27.1 1 or 2 module(78mm x 78mm x 45mm)
1.27.3 6 module(78mm x 205mm x 50mm)
1.27.4 8/9 module(78mm x 230mm x 60mm)
1.32 S/F power plug point with modular type accessories:- Supplying and fixing suitable size G.I.box with modular plate and cover in front on recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch conection painting etc, as required.
1.33 S/F ceiling rose:- Supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box/wooden block including connection etc as required.
1.34 S/F Batten holder:- Supplying and fixing batten/angle holder including connection etc, as required.
1.48 ITC exhaust fan up to 450 mm, sweep:- Installation of exhaust fan up to 450 mm. sweep in the exiting opening, including making the hole to suit the size of above fan, making good the damage, connection testing commissioning etc as required.
2.8 S/F S.P. MCB DB:- Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR)
2.8.3 6 Way,Single door
2.11S/F 'B' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'B' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2.11.1 6/32 amps,single pole, "B" SERIES
2.12 S/F 'C' series. S.P.MCB:- Supplying and fixing 6 amps to 32 amps rating,240 volts, 'C' series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required.
2.12.6 40 amps ,DP
2.19 P/F M.V. danger notice plate:- Providing and fixing M.V danger notice plate of 200mm x150mm made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red coiour on front side as required.
3.7 S/L 8 SWG copper wire ground :- Supplying and laying 8 SWG copper wire 0.50 metre bellow ground level for conductor earth electrode, including soldring etc. as required.
5.1 MV cable laying upto 35 sq.mm. in ground:- Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required.
S/L PVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:1554, part-1)
M- 737 10sq.mm , 2 core
DSR9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
DSR9.1.2 2 X 10 sq. mm (19mm)
FIXTURE AND CHEMICAL EARTHING
M-775 Providing of 12'' (300 mm)exhaust fan of make bajaj/havells/usha/crompton
M-856 Supplying and fixing of LED 15/16 W of make bajaj/havells/crompton
9.1 SITC of following rating LED street lighting luminarie with pressure dia cast housingh and toughned glass cover ,IP 66 Protection , LUMINOUSEFFICARY >_110 LM/W with lens in existing pole /pipe for supply voltage 100-270V AC ,50 Hz, luminarie shall be confirm to IS 10322 part -5 /section -3 and shall be complete with all neccssary accessosries as required.
9.1.7 SITC of LED street light (90/100 watt) of make bajaj/havells/crompton
M-869 Providing of Bulkhead fitting with 9/10 watt LED/ CFL of make bajaj/havells/crompton
9.5 S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230 volt 50 Hz single phase supply etc complet as required of make Havells,Bajaj,Crompton, C & S 9.5.2 20/22 watt Tube light
3.6 Earthing with copper earth plate 600x600x3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc (with charcoal or coke and salt) as required…..
Add 18% GST
Add 1% Lebour Cess
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Techbid14.pdf
Tender Documents • 7.11 MB
BOQ_150515.xls
BOQ • 0.43 MB
Datecorrigendum2nit9.pdf
PDF • 0.82 MB
Datecorrigendumnit9.pdf
PDF • 0.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .