Loading…
Loading…
Tender Value
₹18 L
EMD Value
₹50,000
Closing Date
16 Jul 2026, 12:30 pm6d left
CIVIL SURGEON BHOPAL
Office of the civil surgeon cum chief hospital suprintendent of JP Hospital 1250 Tulsi Nagar Bhopal
RFP for Major OT VRV and VRF Installation at DH Bhopal
2026_DHS_517261_1
T-21644- VRV and VRF AC Installation
Open Tender
Air Compressor
365 days
GOVT JP HOSPITAL BHOPAL
as per Tender
2 documents required · 2 mandatory
₹2,000
Yes
₹50,000
Yes
ROOM NO -21 B BLOCK CS OFFICE
27 Jun 2026
27 Jun 2026
20 Jul 2026
27 Jun 2026
16 Jul 2026
27 Jun 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Laying and Jointing PVC Pipe. Heading | |||||
| 1.01 | Double Skin AHU- SITC of double skin construction AHU with mixing box with FA,RA,SA dampers fitted with 2 stage filtration arrangement completed with 10 micron filters 5micron filters after fan section, suitable for outdoor installation with 45 mm thick panels with inner skin .6mm thick aluminium sheet, thermal break and weather proof motor efficiency factor IE-2. Mixing Box with manually operated fresh & return air AL dampers. Filter section with 50 mm thick box type pre filter(MERV-8)& 305 mm thick rigid media type fine filter (MERV-10), mounted on a common filter frame & Viscous/was able synthetic type air pre-filter Coil section with 8 row deep DX coil Fin. Material. Plain Aluminium Fin Spacing 11-13 FPL. Condensing Tray 22 G SS 304.Test Pressure -38 Kg/Sq. Cm Insulation. Heater section with suitable provision for heater(without heater but with mounting & holding arrangement). Fan section with imported DIDW centrifugal backward curved fan , motor, V belt& Orive set spring isolator. Exhaust air manually operated AI. Damper. Supply air manually operated AL. damper.Weather Proof GI canopy, with spring type vibration isolators, belt drive package with VFD enabled motor, suitable for 415+5% volts,50 Hz AC supply. 5.5 -11 TR cooling capacity with static pressure of 120mm & row deep cooling coil of direct expansion type.CONDENSING UNIT *5.5 TR capacity DX type Outdoor unit complete with Hermetically sealed scroll compressor, Filter dryer expansion valves, shut off valves, corded remote control with electrical panel , Required capacity of AHU integration.Kit from OEM connecting copper pipe of suitable size and required length etc. complete in all respect with first full charge of R 410 A Gas & Oil required for complete system. The rate including sandwich type insulated drain pan made of SS 304, VCD at outlet and inlet and exhaust with arrangements of fumigation, pressure differential, indicators (Manholic Gauge)across fine filter and electric tubular heater for humidity control, and wiring with 2.5 sqmm copper conductor armoured multicore cable for interconnections and for various controls interlocking's etc.
AHU should be design on operations. Capacity - 1200 cfm, Total static pressure 120 mm WG . Condensing Unit Make :- Daikin ,Voltas, O-General, Mistshubhisi Heavy, | - | Each | 1 | - |
| 1.02 | Internal duct acoustic insulation :
Internal duct acoustic insulation: - Supply,
installation, testing and commissioning of
internal duct acoustic insulation with open cell structured class "O" fire retardant nitrile rubber with density 140 - 180 kg/m³ and specs as per RISAC chart specification sheet inside of the AHU supply air ducting up to 4 mtr. length from AHU mouth as per the specifications, it should have antimicrobial properties. 10 mm thick | - | Sq.M | 1 | - |
| 1.03 | External duct insulation :
External duct insulation :- Supplying & fixing of following thickness of mat finish closed cell nitrile rubber (class "O") insulation along with company fitted weather proof UV protected glass wool cloth for protection of weather conditions and mechanical damages to insulation on existing duct after applying two coats of cold setting adhesive complete as per the specifications as required. 19 mm thick | - | Sq.M | 1 | - |
| 1.04 | Grills and Diffusers : | - | - | 1 | - |
| 1.05 | Collar damper :
Supplying & fixing of collar damper complete as required. | - | Sq.M | 1 | - |
| 1.06 | Laminar Air Flow System HEPA FILTERS:
Supplying, Installation, and Commissioning of H-14 type HEPA filters. System should comprise of thick extruded aluminium profile sheet of reputed make and sealed gasket of 1.5mm thickness. DOP tested point scanned HEPA Filters of size – 610 x 610 x 75 mm having efficiency better than 99.97% down to 0.3 micron particle size. Capacity of each filter 500 CFM. Total capacity of each Plenum 2000CFM . Air should diffuse into the theatre uniformly over the total area. | - | Nos | 1 | - |
| 1.07 | The range of ventilated ceiling should provide the sterility and cleanliness required for OT environment. Perfect tightness should be guaranteed by an epoxy seal between filters and holding structure disabling “by pass” of HEPA filters. Two nos. pressure measurement ports shall be provided in each Housing Airflow: 50 +-10% FPM Class 100/ISO class 5 as per international standard & meets DIN 1946-4. D.O.P. tested point to point scanned MINIPLEAT HEPA FILTERS having following technical specifications to be fixed in above Housings | - | Nos | 1 | - |
| 1.08 | STRIP HEATERS :Supplying, installation, testing and commissioning of the following capacities heating kit comprising strip heaters, thermostat, humidistat, contactors etc. complete in existing AHU's including required controls and wiring etc. as req. | - | Nos | 1 | - |
| 1.09 | 2.5 KW | - | Nos | 1 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
Tendernotice_2.pdf
PDF • 0.88 MB
BOQ_623047.xls
BOQ • 0.35 MB
Tenderrules202627.pdf
Tender Documents • 8.72 MB
Download all tender documents and submit your bid