Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | L1 | Accepted-AOC work Awarded due to L1 | |
| 2 | L2₹8.3 L+₹97,707 (13.3%)Rejected-AOC | L2 | Rejected-AOC work Not Awarded due to not a L1 | |
| 3 | L3₹8.4 L+₹1.1 L (14.8%)Rejected-AOC | L3 | Rejected-AOC work Not Awarded due to not a L1 | |
| 4 | L4₹9.2 L+₹1.9 L (25.3%)Rejected-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L4 | Rejected-AOC work Not Awarded due to not a L1 | |
| 5 | L5₹9.5 L+₹2.1 L (28.9%)Rejected-AOC G 11 PLOT NO 48 A GURUKRIPA COMPLEX ZONE II M P NAGAR BHOPAL MADHYA PRADESH 462011 | BHOPAL | MADHYA PRADESH | 462011 | L5 | Rejected-AOC work Not Awarded due to not a L1 |
Tender Value
₹10.8 L
EMD Value
₹22,000
Closing Date
2 Aug 2021, 3:00 pmClosed
Director AMPRI,Bhopal
Near Habibganj Naka, hoshangabad Road , Bhopal
Electrical Panel Work
2021_CSIR_82885_1
1(472)2021 Works
Open Tender
Electrical Works
Item Rate
60 days
CSIR-AMPRI
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
Director AMPRI
₹22,000
Yes
5 Apr 2022
23 Jul 2021
3 Aug 2021
24 Jul 2021
2 Aug 2021
24 Jul 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box/celling rose and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group 'C'.
Wiring for circuit / submain wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed PVC conduit as required
2 X 1.5 Sq.mm + 1 X 1.5 Sq.mm earth wire.
2 X 2.5 Sq.mm + 1 X 2.5 Sq.mm earth wire.
2 X 4 Sq.mm + 1 X 4 Sq.mm earth wire.
4 X 6 Sq.mm + 2 X 6 Sq.mm earth wire..
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6pin 15 / 16 & 5 / 6 amps modular socket outlet and 15 / 16 amps modular switch, connection, painting etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240 volts 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Tripal pole
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required
3 1/2 x 70 sq.mm
3 1/2 x 95 sq.mm
3 1/2 x 120 sq.mm
3 1/2 x 240 sq.mm
Supplying and fixing of following ways surface/ recessmounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
4 Way (4+12), double door,
Providing & installation of maintainance free chemical earthing with the help of GI eath electrode 3 Mtrs. Long fabricated by encapsulating 2 nos. 65 X 6 mm GI strip primary earth electrode in B class GI pipe of 88 mm outer dia. As secondary electrode, sealed at bottom with solid conical GI base seal. The earth electrode has to be vertically driven into the rocky soil earth in 7 inches dia. hole of 3.7 mtrs. depth. The entire earthing is to be enclosed at the top with massonary chamber of size 450 mm X 450 mm made up of modular bricks of class designation 35 & also provided with square shape 300 mm cover of 6 mm thick MS sheet with frame. The vertically driven electrode to be filled with high ultra chemical 2 bags of 25 Kgs each advanced Heavy grade earthing compound mixed with black cotton soil complete as required.
Supplying, installation, testing & commissioning and Replacement of old outdoor panel with Outdoor type double door MV feeder pillar, having in-built locking arrangment, suitable for 415 V, 3 Phase, 50 Hz AC supply system having front surface area not less than 2 sq.mtr. fabricated from CRCA sheet steel of 2 mm thick for frame work, covers & doors, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bar supports, with short circuit with stand capacity of 31 MVA for 1 Sec, bottom base a size of MS section not less than 50mm x 50mm x 5 mm thick, alongwith 1.0 Mtr. long legs of same size entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, having solid connections from main bus bar to switch gears with required size of Aluminium Bus bar and control wiring with suitable size FRLS PVC insulated copper conductor Single core cable for votlage & current respectively, cable alleys, cable gland plates i/c providing following switch gears : (The depth of LT Panel shall not be less than 300 mm.), complete as per CPWD specification. (The board shall be dust & vermin proof free standing type Mounted on base channel of MS section.Installation with brick foundation pedestal of suitable size)main components makes are (L&T/ legrand/Schneider)
A) (Incoming)-a) 630 Amp, 4 Pole, MCCB, having breaking capacity 36 kA, thermal and Magnetic release, with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle. - 1 No. b) 3 Nos.(R-Y-B) Phase indication LED lamps with protection MCB/fuses - 1 Set, c) Multi-function metre (MFM) with to read V, I, Hz, PF, KW & KWH complete with 3 Nos. resin cast CTs of 400/5 Amp, class 1.0 accuracy and 15 VA burden, with control wiring - 1 Set. (d) Danger Plate shall be 150 mm X 100 mm of mild steel - 1 No. B) Bus Bar - Electrolytic high conductivity TPN aluminium bus bars of minimum of 400 Amps capacity suitable for 415 V, 3Phase, 50 Hz AC supply-100% neutral with heat shrinkable coloured sleeves and i/c DMC/SMC bus bare cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. C) Out going - a) 400 Amp, 4 Pole, MCCB, having breaking capacity 36 kA, Thermal and magnetic release with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle.- 1 Nos. b) 250 Amp, 4 Pole, MCCB, having breaking capacity 36 kA, Thermal and magnetic release with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle.- 2 Nos. c) 160 Amp, 4 Pole, MCCB, having breaking capacity 36 kA, Thermal and magnetic release with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle.- 2 Nos. d) 125 Amp, 4 Pole, MCCB, having breaking capacity 25 kA, Thermal and magnetic release with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle.- 2 Nos. e) 100 Amp, 4 Pole, MCCB, having breaking capacity 25 kA, Thermal and magnetic release with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle.- 2 Nos.
Supplying, installation, testing & commissioning and Replacement of old outdoor panel with Outdoor type double door MV feeder pillar, having in-built locking arrangment, suitable for 415 V, 3 Phase, 50 Hz AC supply system having front surface area not less than 2.0 sq.mtr. fabricated from CRCA sheet steel of 2 mm thick for frame work, covers & doors, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bar supports, with short circuit with stand capacity of 31 MVA for 1 Sec, bottom base a size of MS section not less than 50mm x 50mm x 5 mm thick, alongwith 1.0 Mtr. long legs of same size entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, having solid connections from main bus bar to switch gears with required size of Aluminium Bus bar and control wiring with suitable size FRLS PVC insulated copper conductor Single core cable for votlage & current respectively, cable alleys, cable gland plates i/c providing following switch gears : (The depth of LT Panel shall not be less than 300 mm.), complete as per CPWD specification. (The board shall be dust & vermin proof free standing type Mounted on base channel of MS section.Installation with brick foundation pedestal of suitable size)main components makes are (L&T, legrand/Schneider)
A (Incoming)-a) 400 Amp, 4 Pole, MCCB, having breaking capacity 36 kA, thermal and Magnetic release, with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle. - 1 No. b) 3 Nos.(R-Y-B) Phase indication LED lamps with protection MCB/fuses - 1 Set, c) Multi-function metre (MFM) with to read V, I, Hz, PF, KW & KWH complete with 3 Nos. resin cast CTs of 400/5 Amp, class 1.0 accuracy and 15 VA burden, with control wiring - 1 Set. (d) Danger Plate shall be 150 mm X 100 mm of mild steel - 1 No. B) Bus Bar - Electrolytic high conductivity TPN aluminium bus bars of minimum of 400 Amps capacity suitable for 415 V, 3Phase, 50 Hz AC supply-100% neutral with heat shrinkable coloured sleeves and i/c DMC/SMC bus bare cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. C) Out going - a) 250 Amp, 4 Pole, MCCB, having breaking capacity 36 kA, Thermal and magnetic release with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle.- 3 Nos. b) 160 Amp, 4 Pole, MCCB, having breaking capacity 25 kA, Thermal and magnetic release with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle.- 3 Nos. c) 125 Amp, 4 Pole, MCCB, having breaking capacity 25 kA, Thermal and magnetic release with over load and short circuit setting (Ics = 100% Icu) With spreader links and extended rotary handle.- 4 Nos.
Supplying,installation,testing and commissioning and replacement of old AMF control panel with new AMF control panel for auto starting of the 320 KVA Greaves make DG set shall be fabricated from the MS sheet steel , 14m gauge and compartmental design with suitable MS stand. this panel has content of AMF Controller ,battery charger (SMPS),Relay card and automatic changeover of 630 A for current limit with digital display and password protected setting of currentand voltage protection details ,copper bus-bar of 630 Amp .The AMP panel shall have facility to operate the set under test,auto and manual mode. main components makes are (L&T, Elmesaaure/Schneider)
Supplying,installation,testing and commissioning of prewired LED compact light fitting of following type complete with all accessories etc. recess/surface/panel/flase ceiling i/c connection with 3 x 1.5 sq. mm FRLS PVC insulated copper conductor wire earthing etc. as reqd.
a) LED BETTEN fittings surface/wall mounted in 4 feet length, 20 W ,6500K , decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, envoirmental friendly energy efficient suitable i/c connection with 1.5 sq. mm FRLS PVC insulated, copper conductor , single core cable & earthing complete etc. as reqd.
Supplying installation testing & commissioning of 60-80 watt integral LED flood light fitting with driver inside a PDC Housing, IP 66 based energy saving envoirmetal friendy highly efficient, reliable with Driver & all accessories i/c connection complete etc. as required.
Providing and fixing following rating and breaking capacity MCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
63 Amps ,10 KA
Labour for Shiffting of electrical item ,Cleaning and removeing thr grass of Substaion yard in etc work
SSC ENGINEERS
SOLUTION SYSTEM
PRAGATI ELECTRICALS AND ELECTRONICS
VIPIN KUMAR SINGH INFRATECH PVT LTD
TECHNOSWIFT ENGINEERING SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .