Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹17.7 L+₹2.2 L (14.1%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹17.7 L+₹2.2 L (14.3%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher quoting | |
| 4 | L4₹19.7 L+₹4.2 L (26.9%)Rejected-AOC | L4 | Rejected-AOC Rejected being higher quoting | |
| 5 | L5₹26.5 L+₹11.0 L (70.6%)Rejected-AOC | L5 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
12 May 2020, 6:00 pmClosed
GE Hisar
Garrison Engineer Hisar Military Station Hisar - 125006
GE(H)-51/2019-20
2020_MES_336515_1
GE(H)-51/2019-20
Open Tender
Miscellaneous Works
Item Rate
330 days
Hisar Mil Stn
As per Tender documents
6 documents required · 6 mandatory
₹500
GE Hisar
₹70,000
Yes
23 May 2020
27 Mar 2020
14 May 2020
27 Mar 2020
12 May 2020
23 Apr 2020
Amount
Taking down existing street light fittings any type any capacity fixed in any position i.e. on wall / pole / watch tower / High mast for repairing, disconnecting electrically, opening & checking the fitting in presence of Engineer-in-charge or his rep to ascertain defective parts of the fitting and preparing list of defective parts to be repalced for making the fitting fully functional testing and refixxing the fitting in its original position after repairs complete all as specified & directed. Notes for Item No 1.00 :- (a) Items required for repair / replacement work will be measured and paid for separately as "S&F in replacement". (b) Scope of work includes for minor stores e.g. PVC insulation tapes, screws, insulation sleeves, nuts, bolts, washers and flexible cable 23/0.0076 (for internal wiring) etc as required at site.
S&F in replacement LED drivers suitable for any cap & make street light complete all as specified & directed.
S&F in replacement surge protection device 10 KV for LED light fitting complete all as specified & directed.
S&F in replacement cable FRLS, PVC insulated and PVC sheathed size 2.5 sqmm single core multistranded aluminium conductor cable complete all as specified & directed.
Repair work of LED display including soldering etc and making the display functional with all LED lenses in full capacity complete all as specified & directed.
S&F in replacement of electronic ignitor suitable for existing HPSV/MH light fitting 70/150/250 watt all as ordered complete. Make - Crompton Greaves/Bajaj/Philips/Havells
S&F in replacement open construction ballast/choke, copper wound 70 watt for HPSV/MH fittings complete. Make - Crompton Greaves/Bajaj/Philips/Havells
All as per item No 7.00 (here-in-before) but 150 watt.
All as per item No 7.00 (here-in-before) but 250 watt.
S&F in replacement Energy efficient T-5 tube 24 watt 230 volts complete. Make - Crompton Greaves/Bajaj/Philips/Havells
S&F in replacement regular electronic ballast suitable for 2 x 24 watt T-5 lamps etc complete all as specified and directed by Engineer-in-Charge. Make - Crompton Greaves/Bajaj/Philips/Havells
S&F in replacement side holders suitable for 24 watt T-5 tube complete.
S&F in replacement 70 watt sodium vapour lamp tubular in the street light fitting mounted on pole /pillars /walls /High mast light complete all as specified and directed. Make - Crompton Greaves/Bajaj/Philips/Havells
All as per item No 13.00 (here-in-before) but 150 watt.
All as per item No 13.00 (here-in-before) but 250 watt.
S&F in replacement high mast light fitting of any type with LED flood light fitting of cap 120 Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed. Make: Cat Part No JETAIRISFLS120WLED757SYMLTG of of Havells or Cat Part No LFLN-120-CDL/60-M or Cat Part No LTEF120WHPLED of C&S equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F in replacement LED flood light fitting of cap 240 Watt (or nearest higher Cap), energy saving, environmental friendly, long life, exclusive innovative, die-cast aluminium IP65 protection with high power LEDs as light source, suitable for high mast including all accessories for fixing or mounting complete all as specified and directed. Make: Cat Part No LSFO-250-CDL/60-M of Crompton or Cat Part No JETAVALOURFL240WLED757MODWBLT of Havells or Cat Part No LTEF240WHPLED of C&S or equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F in replacement of street light LED light fitting 60 Watt, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device , connected with and including 0.5 sqmm flexible copper multistranded conductor cable including fixed on wall / pole all as specified and directed. Make : Cat Part No ENDURAPEARLPLUSSL60WLED757SASYTOPC of Endura Peral Plus series of Havells or LSTP-60-CDL-M of Crompton or LTESSI60WLED of C&S equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F in replacement of street light LED light fitting 45 Watt, new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover with IP66 protection and impact resistance of IK07 connected with and including 0.5 sqmm flexible copper multistranded conductor cable including fixed on wall / pole all as specified and directed. Make : Cat Part No ENDURACITYLINERNEXGENSL45WLED757SASYBOPC of Endura Cityliner Net Gen series of Havells or LSTP-45-CDL-M of Crompton or LTESSI45WLED of C&S equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F in replacement post top LED lantern of capacity 35 Watt complete, all as specified & as directed. Make :- Cat Part No CORALPT35WLED757PSYMTOPC of Havells or equivalent of make mentioned in Appx 'C' here-in-after.
S&F in replacement twin core flat 10 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum solid conductor over all PVC sheathed complete all as specified and directed.
S&F in replacement MCB TPN of capacity 40A to 63A,10 KA, type 'C',240 volts complete all as specified and directed.
S&F in replacement MCB SPN of capacity 6A to 32A , 10 KA, type 'C', 240 volts complete all as specified and directed.
S&F in replacement street light bracket made to shape out of GI pipe 40 mm bore light grade, 1.5 meter length fixed with & including necessary MS Calmps of size 40x5mm including nuts, bolts and washers on pole etc complete all as specified and directed.
S&F in replacement main switch iron clad rewirable type SPN 32 Amps 240 Volt fixed on pole/ panel/ wall including making connections with and including suitable size cable of existing type, size and of length as existing at site complete all as specified and directed.
All as per item No 25.00 (here-in-before) but TPN 63 Amps 415 Volt.
Labour only for disconnecting, taking out defective under ground LT cable of length not more than 3 meter and of size 10 sqmm to 25 sqmm including excavation, taking out bricks cover and relaying the old cable in loop and making connection with proper new thimbles with cut out boxes,Feeder pillar box, MCBs etc including refilling of sand, relaying old bricks and returning, filling in soil etc complete all as specified and directed.
Excavation in trenches in soft/loose soil n exc 1.50 meter wide and n exc 1.50 meter in depth for foundation of pole, laying cable etc and getting out etc complete all as specified and directed.
All as per Serial item No 28.00 (here-in-before) but depth exceeding 1.5 mtr and not exceeding 3.00 mtr.
Excavation in trenches in hard/dense soil n exc 1.50 meter wide and n exc 1.50 meter in depth for foundation of pole, laying cable etc and getting out etc complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick etc complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point etc complete all as specified and directe.
Taking up bricks laid as cable covers and stacking serviceable brick for reuse at site etc complete all as specified and directed.
Laying only old bricks retrieved from item srl No. 33.00 as cable covers in trenches etc complete all as specified and directed.
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed.
Taking out the old unserviceable LT underground cable upto 16 Sqmm 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed. Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ.
Supply , laying , jointing, testing and commissioning of size 06 sqmm 2 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed. Note : Excavation, earth work, sand cushion & brick protection shall be paid separately.
All as per item No 37.00 (here-in-before) but 10 Sqmm 2 core.
All as per item No 37.00 (here-in-before) but 16 Sqmm 2 core.
All as per item No 37.00 (here-in-before) but 16 Sqmm 4 core.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
S&F in replacement Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in mass concrete including necessary form work etc complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm crushed graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles etc complete all as specified and directed.
Dismantling unserviceable concrete pole/struts of any size removing from site etc complete all as specified and directed.
Supply, erecting & fixing true vertical position pre-stressed concrete pole conforming to IS-1678 of 9 mtr long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 etc complete all as specified and directed. Note :- (i) The rates quoted shall deemed to include taking out conductors, earth wire from existing pole and refixing on new pole. (ii) Earth work & PCC shall be measured and paid separately in respective items.
Re-stringing / Re-stretching including jointing in situ of each span not more than 45 Mtrs between two electric poles having 3 to 5 Nos of ACSR conductors including GI earth continuity wire, with/ without guarding wires on electric poles of any size at different locations all as ordered manually or by telephonically means to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete as ordered.
Prunning / trimming the branches of trees if any along overhead line, 3 mtr on all side below/ above/ sides of overhead line and removing the same upto 150 mtr away each span not exceeding 70 mtr etc complete all as specified and directed. Note :- The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required.
Dismantling insulator any type/any size from LT poles etc complete all as specified and directed.
Supply and fixing pin type insulators LT 1100 Volts grade porcelain vitreous white or brown including one galvanized mild steel spindle, two galvanized iron washers, one galvanised iron nut, 100 mm height, 65 mm dia all as specified and directed.
Supply & fixing shackle type insulator LT 1100 volt grade porcelain vitreous white or brown including galvanised insulator bolts, nuts 12 mm dia and washer including 31x3mm galvanised mild steel straps, 75 mm height and 90 mm dia of insulator complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level) complete, all as directed.
M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm bore connected to main earth wire on pole or control board and GI pipe light grade 20mm dia bore for watering funnel with wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified or indicated including testing on completion including taking down existing u/s earthing complete. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
S&F in replacement street light junction box of size not less than 300x200x150mm, LT 415 V, 3 Phase, 4 wire supply, factory assembled, outdoor type, 2mm thick MS sheet CRCA sheet, single door system, lockable by keys, painted extenrally & internally with two coats of synthetic enamel paint over a coat of red oxide primer & comprising of following :- (a) Aluminium bus bar of cap not less than 60 Amp mounted on PVC insulators, lenght not less than 150mm (b) Aluminium bus bar should have multi holes for connection. (c) MCB SP 06 Amp, type 'C' - 01 No mounted on MCB channel. (d) Two nos cable glands suitable for cable 16 sqmm 4 core. (e) The cut out box should be fixed with pole by 02 x MS clamps of size not less than 25x5mm with suitable nut, bolts and washers. Cost is deemed included in quoted rates.
Rewinding of motor for high mast light of cap 2 HP including repair to winch to lift and lower the high mast light including arrangement for repair / replacement of pinion / gear box, chain, wire etc complete for making the motor and the movement of light carriage simultaneously all as specified & directed.
S&F in replacement 16 sqmm 2 core copper conductor, XLPE insulated PVC sheathed unarmoured cable 1100 Volts grade complete all as specified & directed.
S&F in replacement rigid non-metallic PVC conduit 25mm dia including fixing on pole/wall with fittings like Tees, bends, elbows, reducer, bell mouth etc and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete all as specified & directed.
unique power & control system
m/s Rajesh Kumar
M/s INDER CONSTRUCTION COMPANY
SAINI ELECTRIC STORE
fauji electric works
M/s Pioneer Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .