Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 CrAccepted-AOC | ₹4.3 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹5.0 Cr+₹64.6 L (14.9%)Rejected-AOC | ₹5.0 Cr+₹64.6 L (14.9%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹5.4 Cr+₹1.0 Cr (23.8%)Rejected-AOC | ₹5.4 Cr+₹1.0 Cr (23.8%) | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹5.6 Cr+₹1.3 Cr (29.3%)Rejected-AOC | ₹5.6 Cr+₹1.3 Cr (29.3%) | L4 | Rejected-AOC NOT BEING LOWEST |
| 5 | L5₹6.2 Cr+₹1.9 Cr (43.6%)Rejected-AOC | ₹6.2 Cr+₹1.9 Cr (43.6%) | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹4.3 Cr
EMD Value
₹5.0 L
Closing Date
7 Jan 2022, 6:00 pmClosed
CHIEF ENGINEER CHENNAI ZONE
CHIEF ENGINEER CHENNAI ZONE ISLAND GROUNDS CHENNAI 600 009
PROVISION OF MILITARY DENTAL CENTRE AT SECUNDERABAD
2021_MES_487673_1
89042/E8
Open Tender
Construction Works
Lump-sum
914 days
SECUNDERABAD
As per Appendix A of NIT
8 documents required · 8 mandatory
₹2,000
Garrison Engineer (South) Secunderabad
₹5.0 L
Yes
24 Feb 2022
11 Nov 2021
10 Jan 2022
11 Nov 2021
7 Jan 2022
27 Dec 2021
12 Nov 2021 - 20 Nov 2021
Amount
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XII are under Ser No. 2.00 to 13.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for ROADS /FOOTPATH /CULVERTS as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for SECURITY WALL , FENCING AND GATE as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part- IX
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part- X
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part- XI
Lumpsum price worked out by the tenderer for FIRE FIGHTING SYSTEM as listed in Schedule ‘A’ Part- XII
SCHEDULE `A' PART - XIII is not prepriced by MES and prepriced rates indicating 0.0 under column 5 signifies this fact only. Bidders shall insert their rates in Green field under Col-6.
SCHEDULE 'A' PART XIII - : FITTINGS & FIXTURES AND MISCELLANEOUS ITEMS
System Controller : (m) Designing , supply ,installation , testing and commissioning of system controller as such: (i) The starting of terrace pump shall be automatic i.e., with the opening of any hydrant valve or hose reel on any floor , the pump will start automatically with fall in line pressure. (ii) In addition start /stop push buttons shall be provided at ground floors near internal hydrant for starting the pump manually. (iii) Option to operate terrace pump with remote in place of internal hydrant. NOTE : The control panel for terrace pump shall be provided as per the direction of Engineer in charge in suitable enclosure to avoid unauthorised operation.
Fabrication, supply, installation, testing and commissioning of wall mounted remote indication panel for fire fighting system, IEC-61439, fabricated from not less than 1.6mm thick CRCA sheet, powder coated of approved shade, complete internal wiring,indicating lamps, relays, accessories, numbering, lettering complete in all respect and consisting of the following as required (a) ON/OFF indication of Terrace pump (b) Audio/Visual indication of operation of Terrace pump with reset push button (c) Pressure indication in Fire fighting system (pressure transducer to be installed under seperate system) all as specified and directed.
Supply and fix cable tray of different sizes with thickness, including horizontal and vertical bends, reducers, tees, cross-members and other accessories as required duly suspended from wall/fixed to wall with MS suspenders and including painting with post office red enamel paint as specified and directed. (a) size of cable tray proportional to carry above cables and its specification to be specified as per required Make : Legrand/L&T/ABB
Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured UG cable between various sensors and system controller/starter etc., near terrace pump and outside on surface with connections at both end glands etc all as specified and directed.
4 core x 1.5 sqmm
4 Core x 2.5 sqmm
S&F orifice plate made of 6mm thick stainless steel with orifice of required size in between flange and landing valve of internal hydrant to reduce pressure to working pressure of 3.5kg/cm2 complete all as specified and directed. (a) 80mm dia .
Providing, installation testing and commissioning of dual plate non-return valve of following sizes confirming to IS-5312 complete with rubber gaskets, GI bolts, nuts, washers etc., complete all as specified and directed.
150mm dia
100mm dia
Supplying and fixing 63mm dia 30m long RRL hose pipe with 63mm dia Male and Female Gun metal couplings duly binded with GI sire, rivets, etc., confirming to IS-636 (type-A) all as specified and directed.
Supplying and fixing First-aid Hose reel with MS construction spray painted in Post office Red confirming to IS-884 with upto date amendments, complete with the following all as specified and directed.
20mm nominal internal dia, 30m long hose of thermoplastic (textile reinforced) Type-2 as per IS:12585 all as specified and directed.
20mm nominal internal dia, gun metal globe valve and nozzle all as specified and directed.
Connections from downcomer with 40mm dia stopvalve (gun metal) & MS pipe all as specified and directed.
S&F fire hose cabinet box of size 2100x900x718mm, made out of 16 gauge CRCA sheet with double leafed glazed shutters (glazed with 4mm thick glass) including provision of two length of canvas hose (30m each) , branch pipe, fir hose and nozzle, fireman axe, first aid hose and single outlet landing valve, including applying 2 coat of primer as per seven tank process & powder coated finally in post office red etc., complete all as specified and directed
S&F fire hose cabinet box for hose reel of size 20mm of 30m length made out of 18 gauge CRCA sheet with double leafed glazed shutters (Glazed with 4mm thick glass) complete with coupling branch pipe and nozzles, including allying 2 coat of primer as per seven tank process & powder coated finally in post office red etc., complete all as specified and directed
Material and labour for fire points made out of MS angle iron 40x40x6mm cutting to size, welding etc., including rain protection canopy made out of 2.0mm thcik CRCA sheet painting with two coats of red post office colour all as directed complete with necessary fixing arrangement on wall complete all specified and directed by Engr-in-Charge
S&F fire extinguisher CO2 (light weight squeeze grip type) 3kg capacity (IS:15683) all as specified and directed
S&F fire extinguisher Dry chemical powder (ABC) type, 6kg cpacity (IS-15683) all as specified and directed
S&F fire extinguisher water (Stored pressure type) 9 ltrs capacity (IS:15683) all as specified and directed
Supply,install,comprising & testing of horizontal mounted monoblock pumpset of capacity 3 Hp,1-ph,50Hz,230 volts, 2900 rpm comprising of motor & pump capacity 2900rpm (minimum),discharge capacity of 2.0 to 5.7 liters per second at 36-12 meters head(minimum) with inbuilt strainer, suction & delivery pipe size is 50mmx40mm with necessary base plate for Pump set using angle iron of suitable size for base and frame complete as required at site including foundation bolts of suitable dia and suitable length including electrical connections from starter to motor necessary civil works & PCC works complete to withstand the vibrations and following features all as per manufacturer instructions and complete all as specified and directed (a) Motor shall be energy efficent motor conforming to IS-12615 (b) Body & pre filter made of cast iron. (c)prefilter basket made of stainless steel grade 304 (d) Shaft made of Stainless steel. (e) Sealing arrangement - Gland packing. (f) Impeller made of Stainless steel. (g) Casing made of cast iron. (h) IP-55, F-class insulation. (i) Motor body made of Cast iron (j) Suction Delivery = 50 mm X40 mm
Design Fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system indoor double door front and back opening type,flat roof top extended 100mm all arround ,separate compartment for each control gear,cable alley, provision of knock out type plates for various sizes of cable up to 185 Sqmm 3.5 core in and out , incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Anle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 45 CM below ground level and 15 Cm above ground level and consisting the folowing:- (for Pump House)
Construction of valve chamber of size 900 x 900 mm (Internal size) 900 mm deep with 200mm thick PCC block masonary walls built in CM 1:6 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys(Godrej/Shell), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 450 x 450 mm complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL.
S&F, connecting and testing in repair of Cast Iron non return (Reflux) valves flanged ends, gunmetal seat in swing type design IS-5312 part-I, K517, PN-1.6 both ends flanged etc including jointing materials of size 50mm dia complete all as specified and directed.
S&F in replacement of Cast Iron sluice valves of size 50mm flanged ends stem of SS (AISI410) & Bronze (Gun Metal) working parts IS : 14846 both ends flanged with clamps and check nuts, operating wheel etc, non rising type K504, class PN 1.6 including jointing materials connecting and testing complete all as specified and directed.
Supply and laying steel water tubing heavy grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the 50mm dia all as specified and directed.
Core cutting of existing UG Sump for creating opening of pipes to fit through suitable for 80mm dia GI/DI/CI pipe including necessary packing with binding agents after fixing of pipe into UG sumpcomplete all as specified and directed.
S&F, connecting and testing in repair of Cast Iron foot Valves of size 50mm flanged ends swing type operation with rubber seat as per IS : 4038 single disc with all standard accessories and tested including replacement of nuts, bolts, washers, gaskets, packings etc complete all as specified and directed.
Supply, Installation, testing and commissioning APFC Power panel of 55 KVAR outdoor type,Double Door, factory made, CPRI approved, cubical feeder pillar box panel board IP 54 free standing sutable for working on 440 volts 3 phase 50HzAC supply, floor mounted made out of 3.15mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangement, wather and vermin proof with proper ventilation slots complete of suitable size comprising of Following items:- (a) MCCB, 3 pole, 100 Amps with ultimate breaking capacity Icu - 36kA at 415 Volts and microprocessor release conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 36kA, overload setting 70% to 100%, short circuit setting 5 to 10 times - 01 Nos ( As Incomer) (b) MCCB, 3 pole, 40 Amps with ultimate breaking capacity Icu - 16kA at 415 Volts and thermal magnetic release conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 16kA,thermal overload setting 70% to 100%, short circuit setting 5 to 10 times - 02 Nos (c) MCB, 3 pole, 6-32 Amps with ultimate breaking capacity Icu - 10kA at 415 Volts and thermal magnetic release conforming to IEC 60947 Part -I/IS-13947 Part-I with breaking capacity Ics = Icu at 415 Volts of 16kA,thermal overload setting 70% to 100%, short circuit setting 5 to 10 times - 03 Nos
(d) Capacitor Banks, 20KVAR (1X20KVAR) each, 3 Phase 440V Delta Connected, APP type - 01 Nos (e) Capacitor Banks, 15KVAR (1X15KVAR) each, 3 Phase 440V Delta Connected, APP type - 01 Nos (f) Capacitor Banks, 10KVAR (1X10KVAR) each, 3 Phase 440V Delta Connected, APP type - 01 Nos (g) Capacitor Banks, 05KVAR (2X5KVAR) each, 3 Phase 440V Delta Connected, APP type - 01 Nos (h) Capacitor Duty Contactor 40 A TP 415V - 01 Nos (j) Capacitor Duty Contactor 32A TP 415V - 01 Nos (k) Capacitor Duty Contactor 20 A TP 415V - 03 Nos (l) APFC Relay, Microprocessor based eight stages. (m) Auto / Manual control for each capacitor bank. (n) 200Amps TPN Copper busbar eith colour coded heat shrinkable sleeve. (o) Internal wiring with suitabnle size of PVC insulated stranded copper conductor cable duy crimped with copper lugs & ferruled.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, HDPE pipe havy duty of size 100 mm in any length including jointing materials to carry LT UG cables of size upto 150 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
Design Fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100mm all arround ,separate compartment for each control gear,cable alley, provision of knock out type plates for various sizes of cable up to 120 Sqmm 3.5 core in and out , incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Anle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 45 CM below ground level and 15 Cm above ground level and consisting the folowing.
Design Fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor double door front and back opening type, sloped canopy (Hood) on top extended 100mm all arround ,separate compartment for each control gear,cable alley, provision of knock out type plates for various sizes of cable up to 120 Sqmm 3.5 core in and out , incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Anle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 45 CM below ground level and 15 Cm above ground level and consisting the folowing.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification. GI Electrode Shall be tested from CPRI. The earting pit should be cover with PCC 1:2:4, type B0 using 12.5mm stone aggregate, cover of 300 x 300 mm complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL.
S & F hot press moulded SMC junction / terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixied on pole by means of clamps made out of MS flat iron of size 25 mm x 3 mm including dismantling of old unserviceable all as specified and as directed.Make: Hensel/Syntex/C&S
S&F new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 1.5 Sqmm copper conductor PVC insulated three core weather proof cable etc, from junction box to street light through inside the pole including necessary arrangement and complete all as specified and directed. Make : Havells cat No : ENDURAPEARLPLUSSL90WLED757SASYTOPC/ Bajaj Cat No BRTFG 90 W LEDIV2/ SURYA CAT NO : SLEUL 90W IP66(LXN) or as equivalent.
Supply fixing connecting and testing LED Post top lantern of 36/35 watt capacity with diffuser and painted aluminium deflector including nut, bolts, washers, clamps etc complete all as specified and directed by Engr -in-charge Make PHILIPS Cat Part No BGP161 LED2500/NW PSU 220-240V 7043 IN or CG MODEL NO LPTO 40 CDL/ WIPRO model LP07 501-XXX-57-CL/avells model RUBYPT35WLED830PSYMTOPC/ SURYA MODEL NO : SLE PT 36WETPP or as equivalent.
S&F coloured LED Adore Lamps (two nos) 0.5 W, B22 base complete with two lamp holders, fixed on fabricated branded modular metal flush box 1.22 mm thick duly make embossed, concealed in walls with suitable modular outer cover plate complete with necessary fixing screws etc., all as specified and as directed by Engr-in-Charge
S&F wall mounted fan of size 400mm sweep complete set connecting up including provn of three core flexible copper wire of size 23/0.0076 from ceiling rose to fan all as directed.
S&F 20W (1X2') LED Astra surface & wall mounted LED batten with extruded aluminium housing and robust construction with electronic driver complete with all fixing arrangement suitable for operating voltage 100 to 270 Volts. Make: Philips cat part no. BN150W LED20S-6500 PSE OD GR or equivelent model in WIPRO
&F LED Adore 9 W B22 CDL Ball Lamp with suitable lamp holder complete with all attachment & fixing arrangement. Make: 9W lamp Havells cat No.LHLDEUEBML8R009 (light at mirror )
S&F 10W (1X4') LED smart bright surface and wall mounted LED batten, a reliable and affordable system that delivers up to 40% energy savings. complete with all attachment & fixing arrangement. Make: Philips Cat part No.BN021 LED 10S-6500 PSU GRS1 or equivelent model in WIPRO (at washroom room)
S&F 34W / 36 W (2X2') Full glow high efficiency LED luminaire which provides pure form and glare-free lighting suitable for surface mounting with electronic driver complete with all fixing arrangement. Make: Surya SLE DS 40 22S or equivelent model in Philips
S&F 34W (2X2') Full glow high efficiency LED luminaire which provides pure form and glare-free lighting suitable for recess mounting with electronic driver complete with all fixing arrangement. Make: Philips RC380B LED34S-6500 L60W60 PSU OD S1 or equivelent model in WIPRO (at Special, Dental Hygenist & Gen surgery)
Supply and Fix Telephone socket modular type RJ11 with shutter all as directed by Engineer-in-Charge. Make Legrand Cat No.573426 or equivalent in ABB/SIEMENS
Supply and Fix TV CO-Axial socket outlet modular type complete all as directed by Engineer-in-Charge. Make:LEGRAND/ABB/SIEMENS
S&F MCB DB TPN 8 way, having degree of protection as per IP 43 with metal door (double door) 415 Volts complete with 200 Amps rated copper bus bar with neutral link with provision for MCB TPN as incomer and SP MCBs as outgoing and total number of modules equal to 8 + 24 with blanking plates etc, all as directed as per L&T cat part No.DBTPN008DD
S&F MCB DB SPN 8 way, having degree of protection as per IP 43 with metal door (double door), 240 Volts, complete with 200 Amps rated copper bus bar and neutral link with provision for MCB SPN as incomer and SP MCBs as outgoing and total number of modules equal to 6 with all as specified and directed. L&T cat part No.DBSPN006DD(For Security light )
S&F DB VTPN MCCB incomer, 8 way, 415 Volts, powder coated double door CRCA sheet metal door, complete with 200 Amps rated copper bus bar and neutral link with provision for MCCB as incomer and MCB TP, SP MCBs as outgoing with blanking plates etc, all as directed as per L&T cat part No.DBVTL008DD
S&F sheet metal enclosure with a two pin and earth plug and socket enclosure complete with double pole RCBO of 20/25 Amp for AC and geyser control
S&F MCCB, 4 pole, 160 Amp with ultimate breaking capacty Icu-36kA at 415 Volts and adjustable over load setting Ics = 100% Icu as per IEC 60947-II, class II front face, suitable for isolation with adjustable short circuit setting all as directed. Indo Asian Cat part No.830335
S&F MCCB, 4 pole, 100 Amp with ultimate breaking capacty Icu-16kA at 415 Volts and adjustable thermal magnetic release conforming to IEC 60947 Part-I/IS-13947-Part-I with breaking capacity Ics=100%Icu at 415 Volts of 16 KA, overload setting 70% to 100%, short circuit setting 5 to 10 times all as directed.
Suppy and fix MCB TPN 63 Amps,415 Volts,10 KA, "B" series all as directed. L&T cat No.AU10S4063B
Supply and Fix MCB single pole 6 Amp to 32 Amps, 230 Volts, 10 KA, 'B' series.all as directed. L&T Cat No.AU10S10323B
Supply and fix MCB SPN 63 Amps, 10 KA 'C' series. Indo Asian Cat No.811154
Supply and fixing batten type lamp holder with provision of 9 W LED bulb complete all as directed.
Design Fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor type double door front and back opening type, sloped canopy (Hood) on top extended 100mm all arround, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders duly marked on riveted plates etc complete CPRI approved factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour with dust/vermin proof, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 45 CM below ground level and 15 CM above ground level and consisting the following (Main Incoming Panel Board)
(a) Bus bar copper duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic,non combustible,track resistant high strength FRP insulators 400 Amps for phases and neural set of 4 for RYB &N set of 04 - 01 set (b) MCCB Four Pole 415 Volts 50 Hz 630 Amps adjustable Thermal and Fixed Magnetic type with repturing capacity of 36 KA - 01 Indo Asian Cat No.830413 (As Incomer) (c) On load change over switch 200A 4 pole cat part No.ICAS0320 of Indo Asian - 01 No. (d) MCCB Four Pole 415 Volts 50 Hz 250 Amps adjustable Thermal and Fixed Magnetic type with repturing capacity of 36 KA - 01 No .Indo Asian Cat No.830336 (Incoming)
kb technologies
Sukhdevraj Sharma Engineers & Contractors Pvt Ltd
R. Wadhumal and Sons
Dwarka Pershad Radhey Ramanlal
B.N.S Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .