Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | ₹32.1 L | L1 | Accepted-AOC The lowest e-tenderer |
| 2 | L2₹33.3 L+₹1.2 L (3.62%)Rejected-Finance PLOT NO 106 MIDC SATPUR SATPUR MIDC AREA SATPUR NASHIK MAHARASHTRA 422007 UDYAM MH 23 0018515 | NASHIK | MAHARASHTRA | 422007 | ₹33.3 L+₹1.2 L (3.62%) | L2 | Rejected-Finance Not the lowest e-tenderer |
| 3 | L3₹33.7 L+₹1.5 L (4.81%)Rejected-Finance B 17 SHRIRAM INDUSTRIAL ESTATE G D AMBEKAR ROAD WADALA MUMBAI CITY MAHARASHTRA 400031 | MUMBAI | MAHARASHTRA | 400031 | ₹33.7 L+₹1.5 L (4.81%) | L3 | Rejected-Finance Not the lowest e-tenderer |
| 4 | L4₹35.3 L+₹3.2 L (9.93%)Rejected-Finance | ₹35.3 L+₹3.2 L (9.93%) | L4 | Rejected-Finance Not the lowest e-tenderer |
| 5 | L5₹38.7 L+₹6.6 L (20.4%)Rejected-Finance | ₹38.7 L+₹6.6 L (20.4%) | L5 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
₹42.0 L
EMD Value
₹84,000
Closing Date
23 Jan 2020, 6:00 pmClosed
Commander Works Engineer (Army) Mumbai
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
REPAIRS REPLACEMENT AND IMPROVEMENT TO HT OVERHEAD LINE UNDERGROUND CABLE GOD TRANSFORMERS VCBS RMU AND ALLIED WORKS IN EAST AREA UNDER GE DEHU ROAD
2020_MES_311662_1
83899/DR/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE DEHU ROAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE DEHU ROAD
₹84,000
31 Jan 2020
3 Jan 2020
24 Jan 2020
3 Jan 2020
23 Jan 2020
18 Jan 2020
3 Jan 2020 - 23 Jan 2020
Amount
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in hard/dense soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in soft/dis integrated soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in hard rock soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed by Engineer-in-Charge.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified.
Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 flat, size 300mm x 180mm x 40mm
M&L for sand coushioning with dry and clean over and under the cable for protection of cable , 8.0 cm belove cable 15 cm above the cable complete all as directed(Punned thickness shall be measured for payment)
Dismantling /disconnecting HT cables of any size with accessories. broken unserviceable of any type broken or damaged fitting on poles / laid in trenches and keeping aside for further disposal.
Supply, laying and testing three core power cable, 6.35 kV/ 11 kV (earthed), 95 sqmm, aluminium conductor, XLPE Insulated, PVC sheathed, armoured as per IS 7098 (Part-II): 2011 fixed to wall pole or laid in trenches making all connections with necessary glands lugs bushing complete all as specified and as directed.
Supply, laying and testing three core power cable, 6.35 kV/ 11 kV (earthed), 120 sqmm, aluminium conductor, XLPE Insulated, PVC sheathed, armoured as per IS 7098 (Part-II): 2011 fixed to wall pole or laid in trenches making all connections with necessary glands lugs bushing complete all as specified and as directed.
Supply and fix in repair cable route indicator made out of 25X25X3mm angle iron 150mm clear hight with 100 mm long embedded in PCC 1:3:6 type C-1 ( using 20mm stone aggregate ) block of size 200mm x 200 mm x 200 mm with Letter "MES HT CABLE" suitable inscribed on one CI circular plate 100mm dia 5mm thick welded with angle iron including necessary earth work and two coat of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed
M/L for GI tubing 80 mm dia light grade with all necessary fittings on wall/poles and etc all as specified and directed.
M/L for GI tubing 100 mm dia light grade with all necessary fittings on wall/poles and etc all as specified and directed.
Dismantling cross-arms of M.S channel or angle sections etc. complete and setting aside for re-use within 50 m
M & L for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections incl nut & bolts , washers welding, bending cold or hot drilling holes for bolts, washers in any shape of size as indicated or directed .
Refixing cross-arms of M.S channel or angle sections after repair and painting retrived from item No-14.
Dismantling old unsv over head aluminium conductor steel reinforced any size from HT line
Supply & fixing in repair over head aluminium conductor steel reinforced Ferret 6/1x3.010 on existing HT pole using new aluminium binding wire and binding on insulators by means of 22 gauge aluminium binding wire all as required and specified to permissible sag.
Refixing in repair over head aluminium conductor steel reinforced on existing HT pole using new aluminium binding wire and binding on insulators by means of 22 gauge aluminium binding wire all as required and specified to permissible sag retrived from item No-17.
Supply and fixing cradle, hexagonal/rectangular, fabricated with galvanised steel wire 3.15/ 4 mm dia including stringing, tightning, binding etc complete all as specified an
Dismantling of stay assembly complete with accessories, insulator, clamp etc all as specified and directed.
M & L for stay assembly complete with accessories as shown in electrical plate No 1 including loop type insulator stay clamp (excavation and concrete measured separately) by using stay rod 20 mm dia insulator size 65 mm X 90 mm clearance of 16 mm hole white brown colour complete all as specified and as directed.
M & L for galvanized stay stranded 7/3.15 mm size complete all as specified and as directed.
Dismantling of steel pole/PCC Poles of any size
S & F in repair steel tubular swaged pole 410 SP-55 (11 mtr long) including CI base plate finial taper plug bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.(Note :- Excavation PCC work measured and paid separetaly at appropriate items.
Supply and fixing switches air break, gang operated Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 400 amps 11000 volts complete all as directed at site.
M&L for lightning arresters high tension expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp 11000 volts set of three
M & L for pin type porcelain / polymers vitreous, white brown or green insulator including one galvanized iron washers and one galvanized iron nut 150 mm height 150 mm dia 11000 Volts grade complete all as specified and as directed.
S & F shackle type porcelain / polymers vitreous white brown or green insulator for working pressure 11000 volts of 150 mm dia and 150 mm height including galvanised steel straps of 38 mm X 5 mm size insulator bolt,20mm dia washer & nuts complete all as specified and as directed.
S & F disc type insulator , porcelain / polymers vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green single disc assembly for tension with tension clamps for conductors , working pressure 11000 volts complete all as specified and as directed.
S & F post insulator porcelain / polymers vitreous suitable for 11000 Volts with connected hardware as required for fixing on two/ four pole structure for DO unit or at AB switch working pressure 11000 volts complete all as specified and as directed.
Restringing of HT over head conductor of any type including binding of conductor wire with insulators by means of suitable aluminium binding wire and clearing over head conductors from tree branches around 3 mtrs of distance all as required/ directed at site to ensure permissible sag
M & L for PCC M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate for pole foundation and mass concrete all as specified and as directed.
M & L for PCC M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate for pole coping including necessary formwork fair finished, complete all as specified and as directed.
Supply and fixing Drop Out fuse assembly 11 KV
Supply only HT Tinned Copper fuse wire of capacity 40 to 50 Amp
Supply only HT Tinned Copper fuse wire element of capacity 20 to 30 Amp
Supply only HT Tinned Copper fuse wire element of capacity 05 to 10 Amp
M & L for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 25 cm X 20 cm size
S & F XLPE cable end termination, heat shrink, outdoor type, suitable for voltage 11 KV (Earthed), 3 core 50 to 95 sqmm complete all as specified and as directed.
S & F XLPE cable end termination, heat shrink, outdoor type, suitable for voltage 11 KV (Earthed), 3 core 120-185 sqmm complete all as specified and as directed.
S & F XLPE cable straight through joint, heat shrink, suitable for voltage 11 KV (Earthed), 3 core 50 to 95 sqmm complete all as specified and as directed.
S & F XLPE cable straight through joint,heat shrink ,suitable for voltage 11 kV (Earthed), 3 core 120 to 185 sqmm complete all as specified and as directed.
M&L in repair for Cable jointing kit for 22 KV grade cable for cable end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium onductor cable of size 120 sqmm
M&L in repair for Cable jointing kit for 22 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium onductor cable of size 120 sqmm
Disconnecting / taking out transformer connection in comming and out going any capacity and temporary arrangement to continue supply to existing feeder for supply (Note: Required T&P for lifting and re installation of transformer included in rate quoted by tenderer)
Disconnections of out door type transformer 2500 KVA after taking shut down from the deptt. opening the top cover, taking out the top cover carrying out joint inspection with Engr-in-Charge for identifying the reason of leakage of transformer oil reconnections, re-filling oil upto required level and re-assembling the transformer and complete overhauling including testing including painting transformer with dark grey colour two coat if synthetic enameled paint over existing paint complete. Note :-i) cost of material and labour for various parts will be paid separately under respective items of Sch A. However cost of labour towards dismantling, assembling, joint inspection and identifying the fault is deemed to be included in this item. Cost of sundry items viz cover bolt, plug cap, screws, washer, air release plug etc are deemed to be included in quoted rate. (ii) Filtration / centrifuging of old transformer oil to be measured and paid separately. (iii)Addition/replacement of transformer oil if required will be measured and paid separately.
Rubberized gasket for top cover, LT terminal box, LV/HV bushing, washer, job spindle etc suitable for transformer 2500 KVA complete.
All as per item No 49 but transformer 400 KVA
Rubberized gasket for top cover, LT terminal box, LV/HV bushing, washer, job spindle etc suitable for transformer 400 KVA complete.
All as per item No 49 but transformer 150 to 315 KVA.
Rubberized gasket for top cover, LT terminal box, LV/HV bushing, washer, job spindle etc suitable for transformer 150 to 315 KVA complete.
All as per item No 49 but transformer 25 to 100 KVA.
Rubberized gasket for top cover, LT terminal box, LV/HV bushing, washer, job spindle etc suitable for transformer 25 to 100 KVA complete.
Silica gel assembly / breather each having threaded bore of size 15/20/25mm with new silica gel crystal clear for transformer of capacity upto 500 KVA complete.
M&L for on load filtration/configuration/desludging (in situ) of old carbonized insulating oil (Transformer oil) filled in transformers under service (both power and distribution type) of various capacities and rating outdoor type (22/11KV, 22/0.44KV,11/.44KV ) located and installed at different places under GE Dehu Road area by means of filtration plant (Machine) electric motor driven to improve the dielectric strength up to to 50 KV complete all as directed including filling / topping up insulating oil all as directed. ( Note : Testing of di-electric strength of insulating oil before & after filtration shall be carried out in presence of Engr in Charge / GE . The T&P/Labours required for filtration testing shall be arranged by the contractor at his own risk & cost.(Note : Date of filtration shall be stick on transformer rate are included in qouted rate.)
Supply and filling transformer oil at different location under GE Dehu Road area having dielectric strength not less than 50 KV of approved make.
M & L for spray painting of transformers (in situ)out type of various capacities/ rating installed and located at different sites scattered area under the jurisdiction of GE Dehu Road including control panels incuding 25 to 100 KVA (Transformer): (i) preparation of old surfaces by cleaning, scrapping,rubbing/ polishing etc complete. (ii) Spray painting with two coats of synthetic of approved make / quality all as directed at site. Note : T&P and transport will be arranged by the contractor
All as per Item No 59 above but 150 to 315 KVA ( Transformer )
All as per Item No 59 above but 400 KVA & above ( Transformer )
Dismantling existing HT bushing with copper rod including disconnection of electrical connection and replacement of porcelain bushing vitreous, brown colour,11KV grade along with a set of oil seals& copper alloy stud,nuts,washers etc of suitable size for primary side (HT side ) of outdoor type 11KV for 25 to 75 KVA distribution transformer of any make .
Dismantling existing HT bushing with copper rod including disconnection of electrical connection and replacement of porcelain bushing vitreous, brown colour,11KV grade along with a set of oil seals& copper alloy stud,nuts,washers etc of suitable size for primary side (HT side ) of outdoor type 11KV for above 75 to 100 KVA distribution transformer of any make .
Dismantling existing HT bushing with copper rod including disconnection of electrical connection and replacement of porcelain bushing vitreous, brown colour,11KV grade along with a set of oil seals& copper alloy stud,nuts,washers etc of suitable size for primary side (HT side ) of outdoor type 11KV for 150 to 200 KVA distribution transformer of any make .
Dismantling existing HT bushing with copper rod including disconnection of electrical connection and replacement of porcelain bushing vitreous, brown colour,11KV grade along with a set of oil seals& copper alloy stud,nuts,washers etc of suitable size for primary side (HT side ) of outdoor type 11KV for 315 to 500 KVA distribution transformer of any make .
Dismantling existing LT bushing with copper rod including disconnection of electrical connection and replacement of porcelain bushing vitreous, brown colour, 440 V0lts grade along with a set of oil seals& copper alloy stud,nuts,washers etc of suitable size for primary side (LV side ) of outdoor type 440 V for 25 to 75 KVA distribution transformer of any make .
Dismantling existing LT bushing with copper rod including disconnection of electrical connection and replacement of porcelain bushing vitreous, brown colour, 440 V0lts grade along with a set of oil seals& copper alloy stud,nuts,washers etc of suitable size for primary side (LV side ) of outdoor type 440 V for above 75 to 100 KVA distribution transformer of any make .
Dismantling existing LT bushing with copper rod including disconnection of electrical connection and replacement of porcelain bushing vitreous, brown colour, 440 V0lts grade along with a set of oil seals& copper alloy stud,nuts,washers etc of suitable size for primary side (LV side ) of outdoor type 440 V for 150 to 200 KVA distribution transformer of any make .
Dismantling existing LT bushing with copper rod including disconnection of electrical connection and replacement of porcelain bushing vitreous, brown colour, 440 V0lts grade along with a set of oil seals& copper alloy stud,nuts,washers etc of suitable size for primary side (LV side ) of outdoor type 440 V for 315 to 500 KVA distribution transformer of any make .
M&L for cleaning around two / four pole structure / sub station by surface excavation up to 10cm pole depth incl removing shrubs grass mini plants & other unwanted material / stones & leveling complete all as directed by Engr in Charge
M&L silica gel for transformer indoor/out door type
Disconnecting electric supply and disassemble dismantling the existing 22 kV (VCBs) Vacuum circuit breakers and segregating serviceable and unserviceable spare parts after testing and setting aside for re-use including servicing, overhauling, calibration and testing of the HT panel comprising of protection and control wiring test of CTs, PTs measuring and indicating instrument, earthing, over current, short circuit, insulation replacement of worn out wiring resistance etc. including bus bar insulation applying protective kits entire system up to the entire satisfaction of Engineer-in-Charge. of any Make Note (i) The quoted rate shall be inclusive of required T & P for including servicing, overhauling, calibration and testing etc. (ii) The new spare parts required for replacement shall be paid and measured separately as Supply only. (iii) Servicing, overhauling, calibration and testing etc. shall be carried out as per the Manufacturer’s instructions/ guideline and the necessary literature shall be made available to the department. The quoted rate shall be inclusive of these aspects.directed.
S&F spring charging motor and gear assembly voltage 220 V AC Make : Wolf or equivalent
S&F shunt trip coil 24 V, DC Make : Crompton / Siemence / L&T / or equivalent
S&F segmented gear assembly. Make : Crompton / Siemence / L&T / or equivalent
S&F control fuses rating 3 A to 8 Amps HRC type Make : Crompton / Siemence / L&T / or equivalent
S&F analogue relay with numerical operating voltage 24 V, DC digital type relay Make : Crompton / Siemence / L&T / or equivalent
S&F motor charging mechanism assembly with / trip coils and charging handle voltage rating suitable for 24 V DC.Make : Crompton / Siemence / L&T / or equivalent
S&F trip catch handle Make : Crompton / Siemence / L&T / or equivalent
Indicators 22 mm
S&F Power pack 220 AC Convert to 110V DC 20 Amp
S&F Power pack 220 AC Convert to 30V DC 20 Amp
S&F Space heater 150 Watt
S&F support insulator
S&F HT Tape
S&F HT Sleeve
S&F Spring charging Mechanism
S&F Spring Moter with gear
S&F Numerical relay for transformer protection
M & L for earthing complete with galvanised steel earth plate electrode 60cm ×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected togalvanised strip of size 32 mm x 6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel,earth wire protected by GI pipe 15 mm dia 'light grade' including charcoal dust, common salt, excavation & earth work, PCC Pit with 1:3:6 type C-1, 40 mm thick RCC cover in 1:2:4 type B-1 reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handles 12 mm dia, PGI funnel & GI watering pipe 'light grade' 20 mm bore all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
S & F in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases of bonded in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, 32 mm X 6 mm galvanised iron strip.
Supply and fixing in repairs aluminium conductor bus with tubes of outer dia 32 mm, Inner dia 20 mm thickness 12 mm with colour code RYB radium sticker including fixing aluminium ferrules, lugs of suitable size for connection of bus / DO / GOD / end jumpers with chromium plated nuts bolts arrangements and connections with HG clamps all complete and as directed by Engineer-in-Charge.
Hiring Only sophisticated cable fault locator consisting of microprocessor based prelocator system, HV surge generator, fault pint point surge wave receiver, cable identification instrument, cable tracer for exact location of under ground cable routes for detecting HT/LT UG cable faults located in any stretch/depth. Note : The rate quoted shall deemed to be inclusive of rental charges for T&P like entire cable fault locating instrument, charges for operator, and transportation etc complete.
Supply and fixing boards for displaying 'safety precautions', 'shock treatment chart', 'maintenance chart', 'HT cable layout chart', 'Water supply pipeline route' and alike charts printed on acrylic sheet and mounted on heavy duty board made up of fibre glass (Transparent Acrylic ) sheet 6 mm thick of size not less than 2 sqm, duly digital printing of computer cut lettering or single line diagram with different colour coding including mounting arrangement on wall using SS fastener, nuts, bolts and spacers all complete and as directed by Engineer-in-Charge.
Trimming tree branches upto 10 cm dia around HT /LT overhead conductor , clearance shall be required 1 mtr from all side of the HT/LT over head conductor and depositing a distance not exceeding 50 mtr from working site all as directed by Engr-in-Charge. (Note : T&P such as ladder, cutting tools electrically/manually will be provided by the Contractor. 2/3/4/6 wire span measured in one lenght as RM .Quoted rates shall be deemed as included.)
Testing of out door type transformer up to 2500 KVA incl 11 KV and or 22 KV rating after taking shut down from the deptt and directed by engr-in charge. Following routine testing given below :- (a) Winding Resistance test (b) Ratio test (c) Megger Test (d) Magnetic balance test (e) Open circuit test (f) short circuit test Note :-i) Testing should be carried out by authorised firm of state electric board. (ii) All T&P should be provided by contractor with out any extra cost. (iii) Test report should be submitted by contractor with duly singed by authorised agency.
Testing of transformer protection eqpt WTI, OTI, B-Relay, PRV, MOG and Winding CT testing of 2500 KVA transformer after taking shut down from the deptt and directed by engr-in charge.
Overhauling of existing 22 KV outdoor type Gas cricuit brecker of 33/22 KV rating mmodel no 30SFGP25A of Crompton greaves including calibrating of testing of HT panel comprising of protection of cantrol wiring test of CT's, PT's measuring of indication instrument testing upto entire satisfaction of Engr-in Charge Note:- Only Rep autorised by manufacturer shall be employed by the contractor for overhauling of breacker.
Disconnecting electric supply and disassemble dismantling the existing RMU and segregating serviceable and unserviceable spare parts after testing and setting aside for re-use including servicing, calibration and testing of the RMU comprising of protection and control wiring test measuring and indicating instrument, earthing, over current, short circuit, insulation replacement of worn out wiring resistance etc. including bus bar insulation applying protective kits entire system up to the entire satisfaction of Engineer-in-Charge.
Moter Actuator
Complete breaker mechanism for MCR without tripper assly
PCB for breaker function and ring function
Wiring harness for ring, Breaker and push button.
KOYNA ENGINEERS PVT LTD
Urja Techniques India Pvt. Ltd.
KSP ENTERPRISES
Preeti Enterprises
metro electrical services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .