Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.8 LAccepted-Finance 301 VARDHAMAN CHAMBER II VIKASPURI NEW DELHI 110018 | WEST | DELHI | 110018 | L-1 | Accepted-Finance Tender awarded to L1 bidder | |
| 2 | L-2₹11.6 L+₹82,500 (7.63%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-2 | Rejected-Finance Tender awarded to L1 bidder | |
| 3 | L-3₹11.8 L+₹99,564 (9.20%)Rejected-Finance 1109 11TH FLOOR SPAZE I TECH PARK SECTOR 49 SOHNA ROAD GURGAON HARYANA 122002 | GURUGRAM | HARYANA | 122002 | L-3 | Rejected-Finance Tender awarded to L1 bidder | |
| 4 | L-4₹11.8 L+₹1.0 L (9.53%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L-4 | Rejected-Finance Tender awarded to L1 bidder |
| Sl No | Description | Qty | Unit | Manish Electricals L2 | VOLKS ENERGIE PVT LTD L4 | Arctic Engineering Services L1 | Three D Integrated Solutions Ltd L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | SITC of 4 Way Cassette Unit 3TR Air Conditioning unit at Bukaka Make Passenger Boarding Bridge at aircraft side under ceiling with auto restart operation with copper refrigerant gas pipeline (approximate length of 5 mtr) insulated with nitrile rubber i/c electrical cable of suitable size copper conductor from indoor to outdoor unit and drain pipe ( both length of approx 10 mtr) suitable for operation on 415V , 50 Hz three phase AC supply etc complete as required.
The AC unit shall be fully compatible with the existing Aerobridge system.
Make: Carrier ,Model-40GKX036EA+51MSG036ER3A or Toshiba,Model-RAV-GV3602UD-IN+RAVGV3602A8D-IN or equivqlent as per AAI approved make list. | 1 | No. | 1,35,000 ₹1,35,000 | 1,04,705.44 ₹1,04,705.44 Lowest | 1,45,500 ₹1,45,500 | 1,73,060 ₹1,73,060 |
| 2.00 | SITC of Ceiling mounted Hideway 3 TR Air Conditioning unit at Bukaka Make Passenger Boarding Bridge at routanda side under ceiling with auto restart operation with copper refrigerant gas pipeline (approximate length of 5 mtr) insulated with nitrile rubber i/c electrical cable of suitable size copper conductor from indoor to outdoor unit and drain pipe ( both length of approx 10 mtr) suitable for operation on 415V , 50 Hz three phase AC supply etc complete as required.
The AC unit shall be fully compatible with the existing Aerobridge system.
Make: Toshiba , Model : RAV-SM802AT-E or equivqlent as per AAI approved make list. | 2 | Nos. | 1,45,000 ₹2,90,000 | 1,04,705.88 ₹2,09,411.76 Lowest | 1,39,500 ₹2,79,000 | 1,58,774 ₹3,17,548 |
| 3.00 | SITC of ceiling mounted Hideway 3 TR Air Conditioning unit at Adelte Make Passenger Boarding Bridge under ceiling with auto restart operation with copper refrigerant gas pipeline (approximate length of 5 mtr) insulated with nitrile rubber i/c electrical cable of suitable size copper conductor from indoor to outdoor unit and drain pipe ( both length of approx 10 mtr) suitable for operation on 415V , 50 Hz three phase AC supply etc complete as required.
The AC unit shall be fully compatible with the existing Aerobridge system.
Make: Daikin , Model : FHQ125BVV1B or equivqlent as per AAI approved make list. | 4 | Nos. | 1,65,000 ₹6,60,000 | 1,04,705.88 ₹4,18,823.52 Lowest | 1,39,500 ₹5,58,000 | 1,58,774 ₹6,35,096 |
| 4.00 | Providing of extra refrigerant piping, cabling (More than standard length) , insulating with foam between indoor and outdoor units etc. as required. | 20 | Mtr | 2,500 ₹50,000 | 15,705.88 ₹3,14,117.6 | 1,995 ₹39,900 | 1,913 ₹38,260 Lowest |
| 5.00 | Dismantling of existing all above BOQ item no. 1, BOQ item no. 2 & BOQ item no. 3 Air Conditioning unit at Passenger Boarding Bridge including handover the same to AAI store complete as required. | 7 | Job | 4,200 ₹29,400 | 19,705.88 ₹1,37,941.16 | 8,500 ₹59,500 | 2,500 ₹17,500 Lowest |
| 35.00Note: 1. Rate quoted shall be inclusive of any taxes, duties, Cess, fee, royalty charges etc. levied under any statute but exclusive of GST. Goods & Services Tax (GST) shall be paid to the contractor for any taxable supply/ services/works against a valid tax invoice as per terms and conditions of the contract. | |||||||
Tender Value
₹12.8 L
EMD Value
₹38,300
Closing Date
4 Nov 2025, 11:00 amClosed
AGM EE
SGRDJI Airport Amritsar
Replacement of Air Conditioning Unit at Passenger Boarding Bridge at SGRDJI Amritsar Airport
2025_AAI_250001_1
AAI/ASR/Engg-E/P/eNIT-11
Open Tender
Electrical Works
Works
75 days
Amritsar Airport
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,180
₹38,300
23 Feb 2026
23 Sept 2025
5 Nov 2025
23 Sept 2025
4 Nov 2025
23 Sept 2025
23 Sept 2025 - 29 Sept 2025
SITC of 4 Way Cassette Unit 3TR Air Conditioning unit at Bukaka Make Passenger Boarding Bridge at aircraft side under ceiling with auto restart operation with copper refrigerant gas pipeline (approximate length of 5 mtr) insulated with nitrile rubber i/c electrical cable of suitable size copper conductor from indoor to outdoor unit and drain pipe ( both length of approx 10 mtr) suitable for operation on 415V , 50 Hz three phase AC supply etc complete as required. The AC unit shall be fully compatible with the existing Aerobridge system. Make: Carrier ,Model-40GKX036EA+51MSG036ER3A or Toshiba,Model-RAV-GV3602UD-IN+RAVGV3602A8D-IN or equivqlent as per AAI approved make list.
SITC of Ceiling mounted Hideway 3 TR Air Conditioning unit at Bukaka Make Passenger Boarding Bridge at routanda side under ceiling with auto restart operation with copper refrigerant gas pipeline (approximate length of 5 mtr) insulated with nitrile rubber i/c electrical cable of suitable size copper conductor from indoor to outdoor unit and drain pipe ( both length of approx 10 mtr) suitable for operation on 415V , 50 Hz three phase AC supply etc complete as required. The AC unit shall be fully compatible with the existing Aerobridge system. Make: Toshiba , Model : RAV-SM802AT-E or equivqlent as per AAI approved make list.
SITC of ceiling mounted Hideway 3 TR Air Conditioning unit at Adelte Make Passenger Boarding Bridge under ceiling with auto restart operation with copper refrigerant gas pipeline (approximate length of 5 mtr) insulated with nitrile rubber i/c electrical cable of suitable size copper conductor from indoor to outdoor unit and drain pipe ( both length of approx 10 mtr) suitable for operation on 415V , 50 Hz three phase AC supply etc complete as required. The AC unit shall be fully compatible with the existing Aerobridge system. Make: Daikin , Model : FHQ125BVV1B or equivqlent as per AAI approved make list.
Providing of extra refrigerant piping, cabling (More than standard length) , insulating with foam between indoor and outdoor units etc. as required.
Dismantling of existing all above BOQ item no. 1, BOQ item no. 2 & BOQ item no. 3 Air Conditioning unit at Passenger Boarding Bridge including handover the same to AAI store complete as required.
Note: 1. Rate quoted shall be inclusive of any taxes, duties, Cess, fee, royalty charges etc. levied under any statute but exclusive of GST. Goods & Services Tax (GST) shall be paid to the contractor for any taxable supply/ services/works against a valid tax invoice as per terms and conditions of the contract.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.54 MB
Tender.pdf
Tender Documents • 10.13 MB
BOQ_286618.xls
BOQ • 0.32 MB
CorrigendumIII.pdf
PDF • 0.30 MB
CorrigendumII.pdf
PDF • 0.04 MB
Corrigendum.pdf
PDF • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .