Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 |
Tender Value
Refer Docs
EMD Value
₹15,800
Closing Date
22 Dec 2023, 3:00 pmClosed
Executive Engineer
Executive Engineer PWD Buildings C and M Division Thiruvallur
Construction of Additional Class Room Building in GHS at Samyreddy Kandigai in Thiruvallur District. (Under MPLADS-Scheme-2023-24)
2023_PWD_398921_1
13/DB/2023-24
Open Tender
Civil Works - Buildings
Item Rate
120 days
Samyreddy Kandigai
Please refer tender document
6 documents required · 6 mandatory
₹0
₹15,800
28 Dec 2023
13 Dec 2023
22 Dec 2023
13 Dec 2023
22 Dec 2023
13 Dec 2023
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with Stone Dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification s.
Cement concrete 1:5:10 (one cement five sand and ten hard broken stone) using 40mm size / ISS hard granite broken stone jelly for foundation and floooring including dewatering if found necessary and laid in layers of notmore than 15cm thick complete complying with standard specification and as directed by the departmental officers.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering for sides and soffits including supports and strutting upto 3.29m height for plane surfaces such as RCC floor slab, roof slab, rectangular, square tee or ell beams, lintels, staircase, waist slab, landing slab, landing beam, portico slab, portico beams in all floors with all cross bracings using mild steel sheets of size 90cmX60cm and 10 gauge stiffened with welded mild steel angles of sizes 25mmX25mmX3mm for boarding laid over silver oak joists of size 10x6.5cm spaced at about 90cm centre to centre suppported by casurina props 10cm to 13cm dia spaced at 75cm centre to centre etc. complete complying with standard specification and as directed by the departmental officers.
For Plane surface such as RCC floor slabs, roof slabs, rectangular beams, Tee beams, Ell beams, lintels, landing slabs, waist slabs, canopy slabs etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance with IS 456-2000, using 20mm and down graded hard broken granite store jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ration of 0.55, including admixture (plasticiser/Super plasticiser) in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improveworkability without impairing strength and durability with about (5 cu.m.) 7730 kg of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing etc., and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of mateials).
For Foundation and Basement
S.S. in Ground Floor.
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc., complete complying with standard specification. and as directed by the departmental officers. (Contractor has to make his own arrangements for the supply of steel and binding wire).
Construction of Brick work in cement mortar 1:5 (one cement and five sand) using best quality II class Ground moulded chamber burnt bricks of size 9" x 43/8"x 2 3/4" in for foundation andbasement and super structure, complying withstandard specification including curingetc complete as directed by the departmental officers.
For Foundation and Basement
Construction of Brick work in cement mortar 1:6 (One cement and six sand) using using best quality II class Ground moulded chamber burnt bricks of size 9" x 43/8"x 2 3/4" in for foundation andbasement and super structure, complying withstandard specification including curingetc complete as directed by the departmental officers.
For Foundation and Basement
S.S. in Ground Floor.
Construction of brick partition walls of following thickness using best quality II class ground moulded chamber burnt bricks of size 9" x 4-3/8" x 2 3/4" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately).
S.S. in Ground floor (11.50cm)
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and applying of Two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the departmental officers. (The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet) cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc., complete). The putty should be got approved by the Executive Engineer before use on work.
Providing Wall Black Board in two layers of cement mortar plaster in cement mortar 1:5 (one cement and five sand), 20mm thick and second layer of combination mortar 1:1:6 (cement, lime and sand), 20mm thick and providing border all-round the black board in cement mortar 1:5 (one cement and five sand), 20mm thick and making the surface smooth including painting with best approved quality of black oxide paint for black board etc., complete complying with standard specifications.
Supplying and fixing PVC rain water down fall pipes with new best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.
110mm dia
Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct. 38/40mm thick.
Manufacturing, supplying and fixing of Steel doors with following specification. MS angle of size 40x40x6mm at 3.5 kg/m used for outer frame and MS Angle of size 35x35x5mm at 2.6 Kg/m for the shutter frame. Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18 G CR Sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50kg/m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg/m MS flats are provided diagonally on the rear side of the shutter. 300mm length of highes 4 Nos. for shutters is provided. 6 Nos. of hold fasts 200mm length spliced at the ends are welded to the outer frame of the door. 250mm lenght of Tower bolt 2 Nos., one at the top and the other at bottom are provided. 250x16mm size of One aldrop is provided in case of double leaf door at lock rail section in the door. Additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate placeand 2 Nos. MS Handles of Heavy duty. MS flat 32x4mm at 1.10 Kg/m is provided on the edge of the one shutter to conceal the gap between the two shutters. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete.
Double Leaf
Manufacturing and supplying in position of steel window with new steel window with the following specifications: The outer frame of windows made out of 'Z' section(F7D) of size 33 x 25 x 3mm @ 1.419kg/m and conforming to IS7452-1990. andmullions are made of (f4B) 'J" section of size 46 x 25x 3mm confirming to IS 7452/1990. The shutters are openable shutter should not be exceed a width of 600mm horizontal stiffneers made out of MS flats 18x 5mm is to be provided at equal intervals. The shutter panels shall be covered with 18 gauge MS sheet two numbers of sterdy hinges and onenumber of handle cum latch of special type shall befixed for each openable shutter and suitable openingshall be left for its easy operation one number of adjustable window stay width locking bracket of sufficient length shall be provided for each shutter 4 Nos.of 40 x 40 x 3mm hold fast of 230mm length shall be welded to the outer frames at appropriate point MS square guard bars of 12mm size shall bewelded to the outer frames at appropriate point. MSsquare guard bars of 12mm size shall be welded tothe inner face of the window at equal intervals not exceeding 10cm spacing. The shutter shall be open out side and all members shalls be painted with one coat of red oxide primer. The rate shall be inclusive of cost of all materials, labour charges for fixing,transportation to the site of work, loading andunloading charges and all other incidential charges etc., complete as directed by the departmental officer.
Three Leaves
White washing one coat with freshly burnt white shell lime in all floors including cost of lime, blue powder, fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the departmental officers.
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the departmental officers.
Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a primer coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers). 20mm thick
B JOTHEESWARAN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_475002.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .