servicing and maintenance of Air conditioning, water cooler installed at community center, union offices at reids line, University of Delhi
2026_DU_911294_1
CEET-117
Open Tender
Electrical Works
15 days
North Campus
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Registrar, University of Delhi
Exempted
3 Jun 2026
3 Jun 2026
16 Jun 2026
3 Jun 2026
15 Jun 2026
3 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required | ||||||
| 1.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 15 | metre | 256 | ₹3,840 | BI01010001010000000000000515BI0100001113 |
| 1.02 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 15 | metre | 487 | ₹7,305 | BI01010001010000000000000515BI0100001114 |
| 2Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class 'O' applied by suitable adhesive , as per specifications and as required complete in all respect | ||||||
| 2.01 | 19mm | 10 | sqmm | 724 | ₹7,240 | BI01010001010000000000000515BI0100001116 |
| 3 | Servicing of split/window AC unit of capacity 1.0 TR to 3 TR with the help of pressure washer which includes cleaning of the indoor & outdoor unit, cleaning and flushing of drain tray , drain pipe, checking the refridgerent leakage, electrical power & control connections etc complete as required | 14 | nos | 821 | ₹11,494 | BI01010001010000000000000515BI0100001117 |
| 4 | Supplying and charging of gas completely in 1.5/2.00 split/water cooler i/c checking all the leakage through nitrogen gas and refilling the gas as reqd | 10 | nos | 4,386 | ₹43,860 | BI01010001010000000000000515BI0100001118 |
| 5 | Dismantling ,shifting of existing outdoor unit of split AC (Capacity 1 TR to 3 TR) from one location to another location and reinstallation of same including connection of refrigrant pipe, power/control cable on wall/Terrace with fixing accessories like screw, fastner etc. complete as required. Shifting shall be done within same building | 1 | nos | 1,095 | ₹1,095 | BI01010001010000000000000515BI0100001119 |
| 6 | Dismantling ,shifting of existing indoor unit of split AC (Capacity 1 TR to 3 TR) from one location to another location and reinstallation of same including connection of refrigrant pipe, drain pipe, power/control cable on wall with fixing accessories like screw, fastner etc. complete as required. Shifting shall be done within same building | 1 | nos | 958 | ₹958 | BI01010001010000000000000515BI0100001120 |
| 7 | Replacement of defective fan motor (single phase, 50 Hz) of split AC unit including connection etc. complete as required | 5 | nos | 3,151 | ₹15,755 | BI01010001010000000000000515BI0100001121 |