| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹7.3 L+₹83,191 (12.9%)Rejected-Finance 00 A N SINHA ROAD KADAM KUAN PATNA BIHAR 800003 | PATNA | BIHAR | 800003 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹7.3 L+₹87,043.50 (13.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹8.2 L+₹1.7 L (27.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹8.3 L
EMD Value
₹16,600
Closing Date
13 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
PROVN OF 48V DC SMPS AT 21 CGSR LBW03 PROVN OF AVIATION LIGHT ON OH TANK AT VARIOUS PLACES IN BAIRAGARH REV16 AND CERTAIN OTHER SANCITONED WORKS AT SI LINES AND BAIRAGARH UNDER GE BHOPAL
2020_MES_343267_2
8625/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
BHOPAL
CLASS E CAT b i
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹16,600
Yes
4 Sept 2020
26 Jun 2020
15 Jul 2020
26 Jun 2020
13 Jul 2020
30 Jun 2020
60 days
Amount
COMMON ITEMS FOR JOB 'B', 'D' & 'E'
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells as approved by GE] Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Rate includes chase cutting for concealed wiring.
All as per BOQ item No.1.10 above, but for 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
All as per BOQ item No.1.10 above, one 5 Amps socket outlet point controlled by one switch on same board with other switches complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Socket outlet multipurpose having provision for 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F switch socket combination outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, piano flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T/Havells as approved by GE]
S&F MCB SP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 40 to 63 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T/Havells as approved by GE]
Excavating in trenches, nott exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply, laying, fixing or passing through pipe, 1100 volt grade heavy duty cable with PVC insulated multi stranded alunimium conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 10 Sqmm x 2 core nominal cross section in service connections complete all as specified and directed. [MAKE:- POLYCAB /HAVELLS INDIA LTD/ KEI/V-MARC as approved by GE]
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. [Note:-Compacted/punned thickness shall be measured & paid]
Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed
S&F MCB SPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 5 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T/Havells as approved by GE]
OTHER THAN COMMON ITEMS FOR JOB 'A'
Supply and installation of Float Cum Boost battery charger AC Input with wide operational Range 415V, AC (3 phase)/240V (1 phase) +/- 20% / 10%, 50 Hz +/- 3 Hz, DC output with an adjustable Range:30V, 48V, 110V and 220V, DC capacity 125 Amps with digital meters and all standard protection/indication devices complete all as specified and as directed. [MAKE:- Microtek/ Dyna / APLAB / DELTA / STATCON as approved by GE.]
S&F 12V, 200AH battery with rack complete all as specified and as directed. [MAKE:-EXIDE (Brand: Powersafe) or equivalent in AMRON/PWER PATROL as approved by GE]
s&f 3 core copper conductor not than 16 sqmm size suitable for connection of batteries complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 2.5 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells as approved by GE] Note :- (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 2.5 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells as approved by GE] Note :- (i) Wiring to be done as per approved colour code in IE rule. (ii) Three runs of 6.0 sqmm cable, one run of 6.00 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
S&F single pole and neutral enclosure with two pin and earth, plug and socket, single phase, 240 V with & including 1 No single pole MCB, capacity 20 amps, `C` charactristic, breaking cap 10 KA and industial plug top complete all as specified and directed. [MAKE:-Legrand (Cat no. 607841)/ Siemens/ Schinder/L&T/HAVELLS] as approved by GE]
S&F triple pole and neutral enclosure with two pin and earth, plug and socket, single phase, 240 V with & including 1 No Triple pole MCB, capacity 32 amps, `C` charactristic, breaking cap 10 KA and industial plug top complete all as specified and directed. [MAKE:-Legrand/ Siemens/ Schinder/L&T/HAVELLS] as approved by GE]
S&F MCB TPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 40 to 63 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T /HAVELLS] as approved by GE]
S&F MCB TP, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 40 to 63 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T /HAVELLS] as approved by GE]
OTHER THAN COMMON ITEMS FOR JOB 'B'
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete all as specified and directed.
All as per BOQ item No.1.00 above, but wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination on or 3 pin socket out let 15 amp independent board and provision of 1.5 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete all as specified and directed.
S&F Bell push, flush type, 6 Amp piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and as directed. [MAKE:-ANCHOR (PENTA PC series) or equivalent in LEADER/ CRABTREE/ LEGRAND/ HAVELLS as approved by GE]
S&F switch socket combination outlet multipurpose having provision for 5 pin, 5/6 Amp, flush type, 230 volt AC complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
S&F Bell, Ding Dong type, electric, single phase, 240 volt, AC complete all as specified and as directed. [MAKE:-ANCHOR / LEADER/ LEGRAND /HAVELLS as approved by GE]
S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm, white powder coated CRCA housing with LEDs, seamless front frame with flat white high transmission acrlyic cover including making electric connection from source with PVC sheathed copper conductor wire complete all as specified and directed. [MAKE: Crompton {Cat part No.LCPL-36-CDL(2X2)} or equivalent in Wipro/Crompton/ Havells/ Philips/ SYSKA as approved by GE.]
S&F decorative surface mounting 20 W dome shaped pendant type light fitting including all accessories with and including 1 no.20W LED lamp and making electric connection from source with PVC sheathed copper conductor wire complete all as specified and directed. [MAKE: HAVELLS {Cat part No.LHFHDPE1TN1G020) or equivalent in Bajaj/Wipro/Crompton/ Philips/ SYSKA as approved by GE.]
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings with & including LED lamp white 9 watt B22 CDL, 230 volts complete all as specified and directed. [MAKE FOR HOLDER:-ANCHOR (PENTA PC series)/ LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE] & LAMP : BAJAJ/PHILIPS/SYSKA]
S&F ceiling fan regulator electronic steped type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed. [MAKE:-ANCHOR (PENTA series) or equivalent in LEADER/ CRABTREE/LEGRAND/HAVELLS as approved by GE]
M&L in replacement for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into and including rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 25mm external diameter and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells as approved by GE] Note :- (i) Wiring to be done as per approved colour code in IE rule. (ii) Three runs of 6.0 sqmm cable, one run of 6.00 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
S&F ceiling fan 1200 mm sweep single phase AC 220 Volts 50 HZ, 3 blades, double ball bearing with minimum BEE 5 star ratting including connection with 1.5sqmm, three core copper wire from ceilling rose to fan upto 1 mtr length complete all as specified and directed. [Make:- Crompton/ Havells/ Bajaj as approved by GE.]
S&F sheet metal enclosure for MCB, DB, TPN, 240 Volts, 200 amps rated busbar, 4 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 complete all as specified and as directed. [MAKE: Siemens/ Legrand/ Schinder/L&T/Havells as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
S&F MCB SPN, 240 volts, 10 KA breaking capacity, 'C' curve, of capacity 40 to 63 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed. [MAKE: Siemens/ Legrand/ Schinder/L&T /HAVELLS] as approved by GE]
OTHER THAN COMMON ITEMS FOR JOB 'C'
S&F GI pipe light grade of size 40mm bore for erection of lightening conductors complete all as specified and directed.
S&F GI pipe light grade of size 50mm bore for erection of lightening conductors complete all as specified and directed.
S&F single pointed Aluminium air termination rod 20 mm dia, 300mm long attached to structure with fixed base plate on roof with seasoned IInd class hard wood block block support 150 mm X 150 mm X 200 mm with nut bolts and washers / screw of proper size complete all as specified and directed.
S&F test point terminal block made of gun metal or phosphorus bronze; size 75 mm X 75 mm X 25 mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head brass nuts with washer for fixing of each down lead conductor mounted over seasoned IInd class hard wood block 150mmX150mmX 100mm including box of size 90mm x 90mm x90mm made of 1.6mm plain GI sheet for protection of test point and connection GI strip complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil/hard rock, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified and directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth lead and 32x6mm earh strip upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
S&F porcelain insulators of size not exceeding 10cm long with two nos holes each on both end for fixing properly with nuts & bolts on wall of buildings for seperating lightining conductor or earthing strip from building a;; as required at site complete all as specified and directed. NOTE:- The distance between two insulators fixed on the wall shall not be less than 1 mtr
S&F aluminium strip of size 25 X 3.15 mm on wall with seasoned IInd class hard wood block support of size 100 mm X 100m X 150mm fixed on wall by 200 mm long bolts grouted in wall & over roof with proper junction joint and bends fastened with nuts bolts and washers/screw of size as per site requirement including connecting one end to air termination rod and another end to test point terminal box complete all as specified and directed.
M&L for PCC by providing new PCC grouting plastic gulli on room and flange to be fixed with screw after dismentling complete PCC (!:3:6) type C-1 of size 150 x 600 x 600mm and above 150 x 300 x 300mm complete all as specified and directed.
OTHER THAN COMMON ITEMS FOR JOB 'D'
S&F LED 20 W/21Watt tube light fitting (T8 type) with and including LED retrofit tube 20/21 W, 240V, PV > 0.90, colour Temp 6500 K, system luminious efficancy > 100Lm/W complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. [Make :- Crompton (Batten Cat no. DMLN 1LT 8-16, Integrated LED tube cat no.LT8-20-865-2) or equivalent in Wipro/ Philips/ Bajaj/SYSKA/HAVELLS as approved by GE.]
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 8 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 complete all as specified and as directed. [MAKE: Siemens/ Legrand/ Schinder/L&T/Havells as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. NOTE :- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
OTHER THAN COMMON ITEMS FOR JOB 'E'
S&F LED Aviation light on top of OH tank 15/18/21 m staging with all fittings, fixtures and all accessories comprising of aluminium housing with polycarbonate enclosure including removal of honey bee (if found) complete all as specified and directed. [MAKE: BAJAJ / HOLONIX / HAVELLS as approved by GE]
S&F twin core flat PVC insulated PVC sheathed with multi stranded copper conductor cable of size 2.5 sqmm drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories on surface complete all as specified and directed. [Make : V-MARC/ Plaza/ Havells as approved by GE]
S&F sheet metal enclosure for MCB DB TPNL (Horizontal type), 4 way, 415 volts, 200 Amp rated bus bar having IP-43 protection and double metal door, RAL 9003 powder coated, with MCB as incomer and MCB SP/TP in outgoing including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. [MAKE: Siemens/ Legrand/ Schinder/L&T/Havells as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
S&F Superior quality red and white colour radium for marking on complete OH tank (walls and top dome) of 15/18/21m staging in zig-zag style or as any other pattern as directed by Engineer-in-charge for proper indication during nights complete all as specified and directed. NOTE:- Cost of scaffolding, protection equipments, etc required for exection of work is deemed to be includedin the quoted unit rate.
OTHER THAN COMMON ITEMS FOR JOB 'F'
M&L for point wiring for one light / fan / bell point/ one 3 pin 5 Amp socket outlet on independent board with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one one-way switch, drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. with 3mm thick laminated hylum sheet cover complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells as approved by GE] Note :(i) Wiring to be done as per approved colour code in IE rule. (ii) Rate includes chase cutting for concealed wiring.
Supply, fixing, connecting and testing of electric water heater (Geyser) stationary storage type, closed / vented type, vertical, including inner container of stainless steel, capacity 25 Ltrs, 240 volts, 2000 Watts heating element, 5 star ratting with two heavy duty PVC pipe Nylon braided connection (suitable for hot water) of suitable length, 15mm dfia CP fancy type stop cocks for inlet and out let purpose, anchor fastner, nuts, bolts and washer etc, with power cable 6 Sqmm copper conductors complete all as specified and directed. [Make:- Bajaj Shakti 25L GPV (Cat.150747) or equivalent in Racold (Model No.Altro 2 25 V/H)/ HAVELLS as approved by GE]
S&F Steel water tubes, medium grade, ISI marked, galvanised, 15mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. [MAKE: TATA/ SURYA/ JINDAL/ PRAKASH as approved by GE]
S&F Bib taps cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed. [MAKE:- Prayag (Cat No.8606) or equivalent in JAGUAR/MARC as approved by GE]
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawn in & including non metallic rigid PVC conduit (ISI marked) medium grade not less than 25mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. [Make of Cable : V-MARC/ Plaza/ Havells as approved by GE] Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated busbar, 2 way, single door enclosure, ISI marked complete all as specified and as directed.[MAKE: Siemens/ Legrand/ Schinder/L&T/Havells as approved by GE] NOTE:- MCB shall be measured and paid seperatly.
Deduct schedule of credit (calculation will be done off line) Rs.550.00
UMESH ENTERPRISES
M/S RAKESH TRADERS
M/s VIKAS TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .