| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹60.8 LAccepted-AOC | 1 | Accepted-AOC Awarded | |
| 2 | 2₹62.7 L+₹1.9 L (3.18%)Rejected-Finance HOUSE NO 444 KUMHARIA 5 SIRSA HARYANA 125047 | HISAR | HARYANA | 125047 | 2 | Rejected-Finance L 2 |
Tender Value
₹64.2 L
EMD Value
₹1.3 L
Closing Date
14 Jan 2022, 3:00 pmClosed
EE PHED-2 Sirsa
Sirsa
Estimate for Updation of water works and Boosting Station, repair of water works structures, Laying of distribution pipeline and FHT Connection at Village Randhawa, Distt. Sirsa (Under JJM)
2021_HRY_201680_1
SE PHEC, Sirsa memo No. 9068 dated 22.12.2021
Open Limited
Civil Works
Works
180 days
Randhawa
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹1.3 L
28 Feb 2022
29 Dec 2021
14 Jan 2022
29 Dec 2021
14 Jan 2022
29 Dec 2021
Amount
N.S. Item
Supply & erection of Horizontal spindle split casing type puming sets minimum Four (4) Star rating duties coupled to AC squrrel cage induction type motor with 1440 RPM, 3 phase 50 Hz and accessories as described in Schedule No.II complete in all respect with priming arrangement with complete base frame A) Raw Water Pump set 800 LPM with 12 Mtrs Head
(A) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm and 400mm deep having following items. (A) For Raw Water Pump set 800 LPM x 12 Mtrs Head = 2 Nos. a) Main switch as required - 2 Nos.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) c) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) d) CT 100/ 3 Nos. (AE/KAPPA/L&T) e) VSS 1 No.& ASS 2 No. each of approved make f) SPP 2 No. of approved make g) Motor starter, Star delta 2 No.for 800 LPM 12 Mtr h) Capcitor KVAR as per site requirement 2 Nos. i) Indicating Lamp One Set j) Change Over switch as required = 1 No.
(B) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm and 400mm deep having following items. (A) For Clear Water Pump set 800 LPM x 40 Mtrs Head = 2 Nos. a) Main switch as required - 2 Nos.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) c) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) d) CT 100/ 3 Nos. (AE/KAPPA/L&T) e) VSS 1 No.& ASS 2 No. each of approved make f) SPP 2 No. of approved make g) Motor starter, Star delta 2 No.for 800 LPM 40 Mtr h) Capcitor KVAR as per site requirement 2 Nos. i) Indicating Lamp One Set j) Change Over switch as required = 1 No.
Supplying, erection, testing of ISI marked copper wire for 6 Nos. motors with underground system in PVC and flexible pipes copper wire size 6 sqmm complete in respects with accessories like thimble etc. complete in a;; respects.
Supplying, erection, testing of ISI marked copper wire for 6 Nos. motors with underground system in PVC and flexible pipes copper wire size 10 sqmm complete in respects with accessories like thimble etc. complete in a;; respects.
Supply, erection, testing of light fittings including wire in the Pump Chamber with material upto 10 points including switch, button, plug, PVC Conduit pipe & copper wire etc. as per approved specifications
Providing, erection, testing of reputed make LED Light 100 watts with fitting and accessories complete in all respect
(A) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900 mm and 400mm deep having following items. (A) For Clear Water Pump set 500 LPM x 30 Mtrs Head = 2 Nos. a) Main switch as required - 2 Nos.(L&T Siemens, ABB) b) Volt meter 100x100 mm range 0 to 500 volt 1 No.(AE/KAPPA/L&T) c) Amp meter 100X100mm range 0 to 100 Amp 2 Nos. (AE/KAPPA/L&T) d) CT 100/ 3 Nos. (AE/KAPPA/L&T) e) VSS 1 No.& ASS 2 No. each of approved make f) SPP 2 No. of approved make g) Motor starter, Star delta 2 No.for 500 LPM 30 Mtr h) Capcitor KVAR as per site requirement 2 Nos. i) Indicating Lamp One Set j) Change Over switch as required = 1 No.
Supplying, erection, testing of ISI marked copper wire for 6 Nos. motors with underground system in PVC and flexible pipes copper wire size 6 sqmm complete in respects with accessories like thimble etc. complete in a;; respects.
Supplying, erection, testing of ISI marked copper wire for 6 Nos. motors with underground system in PVC and flexible pipes copper wire size 10 sqmm complete in respects with accessories like thimble etc. complete in a;; respects.
Supply, erection, testing of light fittings including wire in the Pump Chamber with material upto 10 points including switch, button, plug, PVC Conduit pipe & copper wire etc. as per approved specifications
Providing, erection, testing of reputed make LED Light 100 watts with fitting and accessories complete in all respect
Jointing of 300mm i/d RCC pipe channel complete in all respects
Pumping Machinery / Dismantling of Pumping Machinery / Credit of old Pumping Machinery complete job for 2 No. Raw Water & 2 No. Clear Water including cost of Panel Board, Wiring, S.V., NRV, Pipe & C.I. specials / Less Credit of Old Pumping Machinery.
C.I. Valves / C.I. D/F Sluice Valves/Less Old damaged Sluice Valve/ Less of D/F Sluice Valve.
Bidder Name
Amount
SALENDER SINGH(GSTN-NA)
AJIT KUMAR KAJLA AND COMPANY(GSTN-NA)
SALENDER SINGH
AJIT KUMAR KAJLA AND COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .