| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.8 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | 1 | Accepted-AOC Due to L1 | |
| 2 | 2₹17.3 L+₹1.4 L (9.18%)Rejected-Finance 37 A 19 3 B MADHU NAGAR AGRA UP | AGRA | AGRA | UTTAR PRADESH | 282001 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹17.5 L+₹1.7 L (10.5%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 |
Tender Value
₹14.6 L
EMD Value
₹29,200
Closing Date
15 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
PROVN OF 11 KV CAPACITOR BANK FOR MRS-II IN 4 AREA AT AF STN AGRA
2024_MES_638312_1
8000-2126/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE AF Adm Area Agra
₹29,200
Yes
18 Mar 2024
19 Jan 2024
17 Feb 2024
19 Jan 2024
15 Feb 2024
3 Feb 2024
Amount
Supplying, design, manufacturing, fixing and testing of 1608 kVAr, Indoor Panel mounted (Cubical type assembled in section) Auto switched type Capacitor bank, 11 /12KV ( highest working voltage 12 KV), 3 Ph, 50 Hz with ± 4% variation as perIS -13925-Part-I : 2012/IEC 60871-1 , rated current -84.40 Amps, Capacitance -21.15 Micro F, Power frequency withstands voltage between terminals, shorted and container 28 kV rms, Impulse with stand voltage kV peak 75 kVp, shall be enclosed in 2.0 mm and gland plates shall be 3 mm CRCA sheet enclosure included along with Post Insulator, Aluminium Bus Bar, Timer, Space heater, push button, On Off indication lamps, Hardware . Cutting of PCC/ Brick work , grouting the bolts in flour for fixing of APFC panel. The Capacitor bank consisting of following associate equipments. (a). 168 kVAr, 6.35 kV, 1Ph APP Capacitor unit. - 6 Nos.Make -ABB/ Amp Volt / RIE (b). 100 kVAr, 6.35 kV, 1Ph APP Capacitor unit. - 6 Nos. Make -ABB/ Amp Volt /RIE (c). 11 kV, 40 Amp HRC Fuse-12 Nos. Make:- PHOENIX/ANAND/ HAVELLS/ L&T (d) . 11 kV, 400 Amp Isolator WES -1 Nos. Make - PSPL/ Panikkar (e). 11/12 kV, 400 Amp Vacuum Contactor in 3Ph construcion indoor type suitable to switch capacitor in stage - 04 Nos. Make :- EPCOS / C &S / L&T / ABB (f) . 11 kV / (110-180) Volt three Phase Dry Type RVT ( Residual voltage transformer (R.V.T's ) for quick discharge -01 Nos. Make- STAR / KALPA / PRAGATI
(g) Provn of .Discharge device for discharge the capacitor to less than 75 Volt within 600 seconds after disconnection from supply. (h). APFC relay in 4 stage with Auto Manual switching n/off facility. Make :- EPCB/ C &S /L&T/ ABB (j) Maximum creepage of bushing - 25 mm/ KV (k) Rated tempreture 0 to 50 degree. (l) Provision of space only in the CRCA inclosure for reactor in future requirement. (m) NDR relay -01 Nos Make :- EPCOS/ C &S /L&T/ ABB (n) Foundation with PCC (1:3:6) as per manufacturer recommendation. (o) Earthing terminal clearly marked with earth symbol.-02 Nos (p) HT 11 KV danger notice board marked - 02 Nos Make :- Amp Volt / Subodhan / L&T/ ABB/ EPCOS
M & L for earthing with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earth lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40mm bore GI tubing light grade protection pipe upto test point, 20mm bore GI watering pipe light grade with funnel and wire mesh, complete all as per SSR with PCC chamber, 50mm thick RCC cover in (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way, adequate qty of charcoal dust and salt layers all around the earth plate, including earth work in any type of soil, removal of surplus soil and returning filling in as shown on electric plate No 03 of SSR -2009 Part I and earthing connection to HT capacitor bank using GI strip 32 X6 mm with GI protection pipe light grade 40mm bore and testing complete all as specified and directed. (Note: Excavation and earth work is deemed to be included in the unit rates quoted).
M &L for electrical connections using existing HT UG cable up to 240 Sqmm 3 core , 11 KV , HT VCB panel to HT capacitor bank including testing as under using HT magger complete all as specified and directed. Routine Test :- 1. Measurement of capacitance. 2. Voltage test between terminals. 3. Volltage test between terminal and body. 4. Test of internal discharge device. 5. Discharge test of internal fuse.
M/S J J ENTERPRISES
virendera singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .