Chief Engineer, CSD
Chief Engineer, CSD, BARC, Mumbai-85
Replacement of Precision air conditioners ( PAC) of HBNI Server room and other miscellaneous work , Anushaktinagar, Mumbai -94.
2026_BARC_913157_1
BARC/CSD/ET/7/2026-2027
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
365 days
HBNI, Anushaktinagar, Mumbai
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹3.3 L
PG Hostel, Anushaktinagar
15 Jul 2026
16 Jun 2026
15 Jul 2026
16 Jun 2026
9 Jul 2026
16 Jun 2026
16 Jun 2026 - 25 Jun 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling and shifting of existing Precision air conditioners (TSS-1). | 4 | Nos | - | - |
| 2 | Supply, installation, testing and commissioning of floor mounted, bottom discharge precision air conditioners of nominal cooling capacity greater than 20 TR as per technical specification ( TSS-2). | 4 | Nos | - | - |
| 3 | Supply and installation of initial charge of eco-friendly refrigerant gas as per technical specification ( TSS-3). | 250 | Kg | - | - |
| 4 | Supply, installation, testing and commissioning of interconnecting 18 SWG hard copper piping between indoor and outdoor unit as per technical specification ( TSS-4). | 350 | M | - | - |
| 5 | Supply, installation, testing and commissioning of thermal insulation of interconnecting copper piping between indoor and outdoor unit as per technical specification ( TSS-5). | 350 | M | - | - |
| 6 | Supply and installation of interconnecting flexible copper cabling between indoor and outdoor unit , 3 core x 2.5 sq. mm. as per technical specification ( TSS-6). | 180 | M | - | - |
| 7 | Supply and installation of insulated PVC drain piping of 40 mm dia. as per technical specification ( TSS-7). | 40 | M | - | - |
| 8 | Supply and installation of aluminium volume control , multi louvered dampers as per technical specification ( TSS-8). | 4 | Nos | - | - |
| 9 | Supply and installation of GI perforated tray of 300 mm width and 75 mm height as per technical specification ( TSS-9). | 90 | M | - | - |
| 10 | Supply, fabrication and installation of MS structure as per technical specification (TSS-10). | 3,000 | Kg | - | - |
stage.html
html • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 6.25 MB
Tendernotice_2.pdf
PDF • 7.46 MB
TenderDoc.pdf
Tender Documents • 1.89 MB
Technicalspecification.pdf
Additional Documents • 1.11 MB
Blankschedule.pdf
Additional Documents • 0.45 MB
Performa.pdf
Additional Documents • 3.19 MB
ScheduleA.pdf
Additional Documents • 0.77 MB
BOQ_959662.xls
BOQ • 0.20 MB
TECHNICAL_BID_BARC_CSD_ET_7_2026_2027.xls
Additional Documents • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .