Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC TAMIL NADU | PUDUKKOTTAI | TAMIL NADU | 613301 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.0 L+₹37,189 (5.60%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | MENAKA CONSTRUCTION ENGINEERS | SUSAND AGENCIES |
|---|---|---|---|---|---|
| 1.00 | Charges for loading and transporting the 250 NB Spray header pipe of length 12 mtrs total quantity 4 Nos from store to repair bay of Unit IV & V unloading and keeping 2 nos spray header pipe in each unit of air washer Unit IV & V floor as per the direction of Engineer in charge. (Approximate total weight of 4 Nos pipes including flanges coupling and dummy plate = 1 TON ) | 1 | Ton | 3,000 ₹3,540 Lowest | 3,100 ₹3,658 |
| 2.00 | Charges for dismantling the existing spray pipes with spray nozzles and end cap dia 40 mm, length 2750 mm, Total quantity 150 Nos. from the coup[lings of the water header pipes in water chamber of air washer Unit IV & V located at 10.5 Mtrs. floor by cutting / Unscrewing the pipes and retain in the air washer pump room as per the direction of Engineer in charge. (The Rates including the cutting gas , T& P hire charges , Scaffolding arrangements and all other consumables under contractor scope) | 300 | Nos | 90,000 ₹1,06,200 Lowest | 96,000 ₹1,13,280 |
| 3.00 | Charges for dismantling the existing damaged spray header pipes and existing corroded frame of Unit IV & V Air wash by cutting, removing and devoluating the damaged materials to scrap store.(The rates includes all consumables, scaffolding arrangements). | 48 | Mtrs | 38,400 ₹45,312 Lowest | 38,880 ₹45,878.4 |
| 4.00 | Charges for fabrication and erection of fixing frames of spray header pipes in air washer of unit IV & V at 10.5 mtr elevation with channel as per the direction of engineer- In- charge. | 1.88 | Ton | 75,360 ₹88,924.8 Lowest | 77,244 ₹91,147.92 |
| 4.10 | MS Channel (125x65) length 48 mtr | 1,314 | Kg | 85,410 ₹1,00,783.8 Lowest | 91,980 ₹1,08,536.4 |
| 4.20 | 75 x 75 mm thick 6 mm MS angle 50 mtr | 570 | Kg | 37,050 ₹43,719 Lowest | 39,900 ₹47,082 |
| 5.00 | Charges for lifting and shifting the 2 Nos spray header pipe in each unit on the newly fabricated structure in Unit IV & V Air washer located at 10.5 Mtrs. floor.(The Rates including the T& P hire charges , Scaffolding arrangements and all other consumables under contractor scope. ) | 48 | Mtrs | 96,000 ₹1,13,280 Lowest | 1,00,800 ₹1,18,944 |
| 6.00 | Cleaning of spray nozzles: Charges for removing the spray nozzles size 3/8” FPT X 3/16” FPT1500 Nos. and 3/8” FPT X 5/16” 152Nos. from the spray pipes inAir Washer cleaning the nozzles by air removing the end caps(Dummy) of 152Nos. Spray Pipes and cleaning the slurries, mugs, blocking material from the pipes by slightly hammering, cleaning sump refitting the spray nozzles after cleaning the spray and flooding nozzles and end caps in pipes as per direction of Engineer in charge. | 2 | Opn | 64,000 ₹75,520 Lowest | 65,000 ₹76,700 |
| 7.00 | Charge for fixing the G.I Spray Pipe With Spray Nozzles and end cap dia 40mm, length 2750mm total qty.150Nos.after cleaning the female thread and providing the thread in the couplings Size40mm dia X 50mm length by using die & tap set if required, tightening the spray pipe proper positioning of the spray nozzles, charging of water arresting of water leaks if any in the coupling and end cap of the spray pipe at air washer Unit IV & V located at 10.5mtr floor as per the direction of engineer in charge.[ the rates including all consumables like Teflon tape, T&P hire charge scaffolding arrangement etc, under contractor's Scope] | 300 | Nos | 1,38,000 ₹1,62,840 Lowest | 1,50,000 ₹1,77,000 |
| 8.00 | Charges for providing scaffolding arrangement up to the height of 5 to 6 mtr for cutting, removing the existing spray header pipe and replacing the new header pipe after completion of work dismantling the scaffolding arrangement including cost of scaffolding materials and hire charges for T&P's | 2 | Opn | 28,000 ₹33,040 Lowest | 29,200 ₹34,456 |
Tender Value
Refer Docs
EMD Value
₹6,800
Closing Date
9 Jul 2025, 2:00 pmClosed
CE/TTPS
O/o CE/TTPS
TTPS Operation Circle MPM-II AC Plant Renewing of 250 NB spray header pipe of length 12 mtrs in Unit IV and V Air Washer System
2025_EB_573204_1
CE/SE/O/TTPS/Spec.No.138/25-26
Open Tender
Maintenance Works
Item Rate
50 days
TTPS
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹6,800
Yes
30 Oct 2025
24 Jun 2025
10 Jul 2025
24 Jun 2025
9 Jul 2025
24 Jun 2025
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .