| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.8 LAccepted-AOC | 1 | Accepted-AOC BEING L1 | |
| 2 | 2₹11.3 L+₹19,031 (1.71%)Rejected-Finance | 2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | 3₹11.4 L+₹28,910 (2.60%)Rejected-Finance 41 A COLONELGANJ CANTT FATEHGARH DISTT FARRUKHABAD UP 209601 | FATEHGARH | FARRUKHABAD | UP | 209601 | 3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | 4₹12.1 L+₹98,085 (8.80%)Rejected-Finance A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | 5₹13.0 L+₹1.8 L (16.3%)Rejected-Finance | 5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
21 Oct 2020, 6:00 pmClosed
GE FATEHGARH
GE MES FATEHGARH
REPAIR TO PLUMBING , SANITARY AND ALLIED WORKS IN JCOs/ORs Md Accn OF SIKH LI RC AT GE FATEHGARH.
2020_MES_378929_1
GE/FAT/ET-10 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
GE MES FATEHGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE FATEHGARH
₹32,000
Yes
5 Jan 2021
23 Sept 2020
23 Oct 2020
23 Sept 2020
21 Oct 2020
7 Oct 2020
23 Sept 2020 - 6 Oct 2020
Amount
Taking down GI pipe 15mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking down GI pipe 20mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
S&F G.I. pipe 15mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling and laid in floors complete all as specified and directed.
…ditto as above but except pipe …..ditto…
S&F G.I. pipe 20mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling and laid in floors complete all as specified and directed
…ditto as above but except pipe …..ditto…
S&F in repair C.P. Bib taps(Fancy type) 15mm bore cast copper alloy,screwed down,screwed for iron pipe or brass ferrule complete all as specified and directed
S&F in repair C.P. Bib taps, long shank(Fancy type) 15mm bore cast copper alloy ,screwed down,screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair C.P. shower rose for 15 mm bore pipe complete all as specified and directed
S&F in repair 15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixe
S&F in repair 20mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete.
S & F in repairs 15 mm bore Bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&f in repair 15mm bore Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed.complete all as specified and directed.
S& F in repair15 mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed.
S& F in repair 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed.
S&F in repair C.P. Angle valve (fancy type) 15mm bore,cast copper alloy screwed down,high pressure, screwed both ends for iron pipe or unions complete all as specified and directed
S&F in repair C.P. pillar tap( fency type 15mm bore)cast copper alloy with capsten head CP screwed down high pressure with or without letter 'Hot' or 'Cold' with long screw shank and flt nuts screwed for iron pipe complete all as specified and directed
S&F in repair 15mm brass CP mixer (single hole) for mixing hot & cold water screwed down for iron pipes and fixed in repairs.
S&F in repair PVC connection 15mm dia, 450mm long with brass nut complete all as specified and directed
S & F in repair 32mm bore dia, Waste coupling of PTMT (half or full threaded)
S& F Swivel shower of PTMT , with arm any colour for fixing with 15mm pipe.
S&F in repair PVC valveless, 10 ltrs, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including fixing as per site complete all as specified and directed
S&F rotational moulded polyethylene triple layer wall construction, white , water storage tanks (cylindrical vertical with closed up, capacity in 500 Ltrs, hoisted and fixed in position with all fittings and fixtures including float valve 20 mm bore in position complete all as specified in SSR Part-I. include is dismantling of existing water tank etc complete all as specified and directed.
S& Fixing in repair Vitreous china ,Squatting pan 'Orissa' pattern size 580mm X 440mm white with integral foot rest including all joints and making good to the floor,etc complete all as specified and directed.
Dismantling of exisitng water proofing treatment of any type, Cleaning the surface by roughening, sweeping clean and washing down and applying cement slurry @ 3 kgs/sqm with and inlcuding M & L for water proofing treatment to roof slab with APP modified polymeric membrane with centre core 100 micron HMHDPE out film 20 micron each having thickness 3 mm, weight not less than 3.00 kg/sqm with 100 mm side overlap and 150 mm end lap and laid with following course of descriotion below :- (a) Applying evenly a coat of bituminous primer conforming to IS 3384 - 1965 @ 0.50 ltr /Sqm prepared surface till the surface is properly impregnated and solvent oil in primer shall be allowed to evaporate completely. Second coat of bonding material using hot blown grade bitumen 85/25 @ 1.2 Kg/Sqm conforming to IS 702 - 1988 over bituminous primer. (c) Third course i.e. laying of APP modified polymeric membrane describe hereinbefore with 100 mm over lap in longitudinal direction and 100 mm in transverse direction, all joints and changes in all diretion should be curred with cement mortar (1 : 3 ) mixted with SBT Latex @ 200 ml per bag of cement and curred well before laying themembrane. (d) Fourth course of bonding material using hot blown grade bitumen 85/25 confirming to IS 702- 1988 @ 1.2 kg/sqm over membrane. (e) Fifth course is sprinkling a layer of course sand dusting @ 1 Kg/Sqm as directed.
M&L for 40mm thick cement concrete 1:2:4 type B-0 (12.5mm graded stone aggregate) as in RCC roof surface with mixing of water proofing compound as per manufacturer instruction to horizontal or vertical surfaces finished cement concrete surface even and smooth using extra cement including necessary form work (Water proofing compound will be measured separately)
M&L Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer of cement (1:4) complete as all specified and directed. Note:- Dismantling included in item no 26
S&F in repair Vitreous china WHB size( 550mm x 400mm) including cutting or pinning and fixing of brackets , incl 32mm dia waste pipe and 32 CP waste coupling. Also providing PVC pillar Tap 15mm dia complete all as specified and directed
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
S&F in repair sink with drainage board made of stainless steel l mm thick kitchen or laboratory with plugs, washers and wastes; including provision and fixing to wall MS Bracket of angle 25mmX25mmX3mm ) overall size (915mm x 460mm) bowl size (410mm x 330mm x 160mm ) complete all as specified and directed.
S&F in repair PVC cabinet looking mirror of size (350mm x 450mm) with openable door as directed complete all as specified and directed.
Taking down eaves gutters and PVC rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
S& F PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends any radius complete all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius with access door complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends any radius with access door complete all as specified and directed.
S&F PVC (SWR) 110mm bore branch piece, single (single Y) equal or unequal complete all as specified and directed.
S&F PVC (SWR) 110mm bore branch piece, single (single Y) equal or unequal with access door complete all as specified and directed.
S&F PVC (SWR) 110mm bore junction single, (Single T) equal or unequal complete all as specified and directed.
S&F PVC (SWR) 75mm bore junction single, (Single T) equal or unequal complete all as specified and directed.
S&F PVC (SWR) 110mm bore junction single, (Single T) equal or unequal with access door complete all as specified and directed.
S&F PVC (SWR) 75mm bore junction single, (Single T) equal or unequal with access door complete all as specified and directed.
M&L for Cutting chases,pining in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landing steps, cills, sunshades ,shelves,lintels,etc.; and cutting chases for concealed water tubing or concealed conduit,wiring,etc,and making good cutting not exceeding 10 cm girth in brick walls complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
Disconnecting existing tanks, exc 250 ltrs but not exc 500 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required including cleaning and removing all scale and dirt etc. from tanks exc 250 ltrs but not exc 500 ltrs capacity, from mouths of circulating pipes, etc. and washing the tank with bleaching powder, fixing the tank in position & reconnecting the tank,fittings & testing on completion. Note-Rates quoted by the contractor includes the cost of writing DATE OF CLEANING : DD: MM:YYYY with white paint with minimum 75 mm high & 3 mm wide letters.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing dressed stone work and precast concrete articles, complete all as specified and directed.
M&L of brick work with sub class 'B' burnt bricks straight or curved on plan exc. 6 m mean radius built in cement mortar (1:6) complete all as specified and directed.
Rendering 15mm thick cement plaster in cement mortar (1:4) on on fair faces of brick work or concrete and mix with water proofing compound and finished even and smooth (without using extra cement) complete all as specified. Note:- ( Water Proofing Complete shall be measured and paid Separately )
M&L for coping/bed blocks, kerb at junction of parapet wall & roof etc. in PCC 1:2:4 Type B-1 ( using 20mm graded stone aggregate ) complete all as specified and directed.
M&L for two coats of cement based paints including preparation to newly plastered surfaces of walls etc completed all as specified and directed.
M/S SRI JAGDAMBE TRADERS
MS. BK BROTHERS AND CO
M/S WASEEM KHAN CONTRACTOR
M/s Moti Babu Agarwal
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .