| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹59.5 L+₹1.7 L (2.92%)Rejected-Finance H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹59.7 L+₹1.9 L (3.20%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹59.9 L+₹2.0 L (3.54%)Rejected-Finance H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L4 | Rejected-Finance Being not lowest |
Tender Value
₹63 L
EMD Value
₹1.3 L
Closing Date
23 Jun 2022, 6:00 pmClosed
Col Jiagar Trivedi, SM
HQ CWE (AF) GUrgaon Old Palam Road Delhi Cantt - 110010
RE-CONSTRUCTION OF BOUNDARY WALL and OTHER SERVICES DAMAGED BY STORM AT AF STN ARJANGARH UNDER GE (AF) GURGAON
2022_MES_529577_1
CWE/GGN/GT-05/2022-23
Open Tender
Civil Works
Item Rate
120 days
AF Stn Arjangarh
As per NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) Gurgaon
₹1.3 L
Yes
5 Jul 2022
8 Jun 2022
25 Jun 2022
8 Jun 2022
23 Jun 2022
11 Jun 2022
8 Jun 2022 - 10 Jun 2022
Amount
Dismantling of mild steel work of any description and in any position complete all as specified and directed.
Taking down concertina coil inner dia of coil not less than 600 mm dia and fixed on poles etc on wall complete all as specified and directed.
Taking down Barbed wire any description and in any position , complete all as specified and directed.
Refixing only mild steel works in post struts in fencing incl cutting top to shape as direted, drilling holes, notching for wire etc ,flat iron fillets for securing wire mess incl all necessary drilling, bolting etc and similar work confirming to Fe-290 complete all as specified and directed.
Demolition of brick masonry built in cement mortar as in wall, drain etc, and removal of debries outside MoD land complete all as specified and directed.
Removing mortar from and cleaning bricks, stacking for measurement including all extra handling for re-using of old bricks and removal , disposing off rubbish outside MoD land. Complete all specified and directed. Note : 455 Nos bricks shall be considered for reuse in one Cum brickwall
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc or for shafats wells cesspits manholes, pier holes etc hard / dense soil getting out, complete all as specified and directed.
M&L for Plain cement concrete (1:4:8), type D-2, using 40mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed.
M&L for Use and waste of form work to sides of concrete foundations, footing, bases of columns, raft beams, sides and soffits of plinth beams and similiar works etc complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, for square, rectangular or polygonal, rough finished surfaces of concrete etc complete all as specified and as directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in foundations including rafts, column footings, plinth beams, etc complete all as specified and as directed
M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts etc complete all as specified and as directed
M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in beams, cantilever, lintels over 1.5m span etc complete all as specified and directed.
M&L for MS TMT bars 10mm dia and over. Cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 5 mm dia and over, upto and including 10 mm dia as in stirrups, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed
M&L Brick work except bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:4 complete all as specified and directed. Note : Old retrived bricks shall be used
M & L Rendering 15mm thick on other than fair faces of brick work in CM 1:4 finished even & smooth without using extra cement complete all as specified and directed.
Preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth in soils, complete all as specified and directed.
Removal excavated material to distance not exceeding 100 metre and depositing where directed at level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed.
S&F mild steel work s in post struts in fencing incl cutting top to shape as direted, drilling holes, notching for wire etc ,flat iron fillets for securing wire mess incl all necessary drilling, bolting etc and similar work confirming to Fe-290 complete all as specified and directed.
M&L for mild steel bolts purpose made with hexagonal or sqare head one end and screwed the other or screwed both ends each screwed and to be fitted with washer and one hexagonal and square nut exc 12 but n exc 20 complete all as specified and directed.
M&L Prepration new steel surface of any description not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide complete all as specified and directed.
M&L Prepration for old steel surface by complete removal of old treatment/rust of any description not other wise described over 10 cm width or girth and applying Two coat of synthetic enamel paint over one coat of red oxide complete all as specified and directed.
S&F 0.50mm thick punching tape concertina coil 900 mm coil dia as per IS code each Roll having a weight of 14.00 to 15.00 kg and expanded upto 7.00 mtr in length including necessary securing/binding with binding wires on steel post complete. Concertina coil inner dia of coil not less than 900mm dia and fixed on poles etc on wall complete all as specified and directed.
Supply and fixing Galvanised 2 strand, steel barbed wire 2.24mm dia with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete all as specified and directed.
M&L for 110 mm dia PVC pipe in weep holes complete all as specified and directed.
Dismantling Steel pole/strut any size any description and removing from work site
Dismantling Concrete pole strut any size and transporting to store
Dismantling cross arms of MS cahnnel or angle sections etc complete and setting for reuse or tpt to store
Dismantling insulators any type any size
Dismantling of ACSR or AAC conductor
Dismantling of earth wire or copper conductor service feeder or distribution span
Supply & erecting steel tubular swaged type pole confirming to IS specification complete with base palte, welded top cap over all vertical length 9 mtr type 410-SP-31 including painted of two coats of red oxide primer out side and internally black bituminous paint through out and externally painting of one coat with aluminium painting, including provision of black and white strip width & height of strip as ordered by Engr-in-Charge on poles up to 1.5 m tr high above coping level and numbering of poles what size of numbers & colour all as specified.
Supply and fixing prestressed concrete pole 11 Mtr long 152 mm x 152 mm at top and 152 mm x 260 mm at bottom of class 9 complete, including disconnecting and taking out old damaged PCC pole all as directed.
S&F cross arms made out of mild steel channel or angle section of reqd size and shape including clamp back plate with bolts, nuts, washers drilled for insulator bolts, welding, binding cold or hot in any shape or size as directed and painted with two coats of aluminum paint over a coat of red oxide primer after necessary preparation of surfaces complete all as specified and directed.
Supply and lay and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 4 core layed in trenches, passing through floor/walls, passing through GI pipe under road cutting etc complete all as specified and directed by Engr-in-charge.
S & F pole box for street light dust and vermin proof make Sintex model GSJB 3020 complete with aluminum bus bar 04 nos. of capacity 200 amps on epoxy insulators incl one MCB SP C series 06 amps 10 KA capacity for Security light connection including suitable clamps & suitable size brass chrome plated glands-02 nos at bottom for cable entry and exit complete all as specified and as directed.
Supply and fixing in repair LED street light fittings 70 watts 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including therma; management in multiple optics complete with IP 65/66 protection complete with provision of twin core teisted copper wire 23/0.0076 upto security light from pole loop box. Complete all specified and directed.
Suuply and fixing street light brackets made out of GI tubing light grade, 40 mm bore 1200 mm long bent to sahpe at 120 degree, fixed on pole by providing MS clamp made up to flat iron 50 x 6 mm including nuts and washer of suitable size complete all specified and directed.
M & L for GI tubing (light grade) with all necessary fitting laid in trenches/under road crossing, or fixed on poles/walls/under floor etc complete all as specified and as directed for the following sizes:-
a) 40 mm dia bore
Material and labour for coping to street light poles with PCC Type B1, 1:2:4 (using 20mm graded aggregate) incl necessary form work complete all specified and directed.
Supply, stringing and fixing in repair of aluminium conductor steel reinforced (ACSR) of any type including binding with and including suitable size of binding wire complete . .Including dismantling and taking out warn out ACSR conductor from overhead electric line complete all specified and directed.
All as per item No. 44 but GI wire 4 mm dia complete all specified and directed.
M& L Pin type, porcelain, vitreous, white, brown or green insulator, 150 mm height, 150 mm dia for 11000 volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut andand taking out of unsv one complete all as specified and directed.
S&F in repair new Shackle type, porcelain, vitreous, white, brown or green insulators 150mm dia and 150 mm height for working pressure 11000 volts including galvanised mild steel strap 38 x 5 mm size, washers, 20mm dia insulator bolts, washers & nuts and and taking out of U/S one complete all as specified and directed.
M& L in repair for Disc type insulator, porcelain, vitreous, white, brown or green insulator ( Single disc assembly ) of size 145 mm height, 255 mm dia ball socket type for working pressure 11 kv volts grade including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut and taking out of U/S one complete all as specified and directed.
Excavation in trenches in hard/dense soil not exc. 1.5 metre wide and but exc. 1.50m deep and getting out in hard dense soil complete all as specified and directed.
Removing excavated material n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L for sand cushning to U/G cable in layers of 23 cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed.
Supply and lay well burnt brick class B as protection to cable in cable trenches all as specified and directed.
Net Contract Sum will be after deducting Sch of Credit of Rs 2,68,194.00
Ish Engineers and Contractors
M/S Rohit Enterprises
PAWAN KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .