Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹28.8 L+₹94,871.47 (3.41%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹30.0 L+₹2.2 L (7.99%)Rejected-Finance | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹30.4 L+₹2.5 L (9.12%)Rejected-Finance | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹34.9 L+₹7.0 L (25.3%)Rejected-Finance | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
7 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U) E/M Meerut
Roorkee road Meerut Cantt
REPAIR / MAINT OF LT DISTRIBUTION SYSTEM, STREET LIGHTS AND ALLIED WORK AT DABATHWA AREA UNDER AGE E/M (ES) AT GE (U) MEERUT CANTT.
2023_MES_602261_1
8516/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U) E/M Meerut
₹66,000
Yes
7 Aug 2023
9 Jun 2023
10 Jul 2023
9 Jun 2023
7 Jul 2023
23 Jun 2023
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Supplying and fixing 100mm nominal bore Galvanised mild steel pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified of the following bore (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately)
Supplying and fixing 40mm nominal bore Galvanised mild steel pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified of the following bore (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately)
M&L burnt clay fly ash old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Material and labour for river sand, unwashed and screened dry ) for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . (Note:Punned thickness shall be measured for the purpose of payment)
Site cleaning in soft/loose soil of surrounding areas of 2/4 poles plinth mounted transformer / E/M substation including removing of tree branches, plants, brushes etc. Complete all as specified.
S&F in repairs 3 core , stranded copper conductor cable 2.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade for making connections to street light fittings complete all as specified and directed.
Dismantling and taking down of LT U/G cable of any size/type
Supply & Laying jointing, testing and commissioning LT XLPE, PVC insulated, PVC sheathed armoured LT 1100 volt grades heavy duty with aluminium stranded conductor through pipes, induct, on poles, in trenches etc including taking down complete of following sizes
10 Sqmm, 4 core
16 Sqmm, 4 core.
35 Sqmm, 3.5 core.
240 Sqmm, 3.5 core.
300 Sqmm, 3.5 core.
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any dahage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
S&F in repairs 3 Mtr Clear height Decorative Ornamental Pole duly PU (Poly Urethane) Painted (RAL color code as per client choice), made of high tensile Steel Pipe, Galvanised before PU Painting. Pole shall be in minimum 2 Sections, where Bottom section dia-114mm minimum upto 1200mm height from base plate. Top section dia-60mm minimum. The Top section of pole must have Cast Aluminium Embleshments throughout the length. Base Plate size 200x200x10mm with PCD of 200mm. Foundation bolts set of M16x450mmx 4 Nos made of EN8 grade steel should be used only for erection. A lockable door of suitabe size should be provided at bottom section for termination and connection with provision of mounting backelite sheet and connector, MCB etc. . Similar to Bajaj Model No- BJPL ECO 3M PT Pole Note: Manufacturer should have their own manufacturing and galvanising plant ,the certificate for the same should be submitted by contractor prior to purchase. Poles and post top lights should be of same make Make: Bajaj,Havells,Phillips
S&F in repairs 45W 3000K Ring Type decorative Post Top Light, Pressure Cast aluminium PU Painted housing with casted aluminium heat sink, having Optical grade PC diffuser with Symmetrical arrangement of LED's. Suitable for upto Ø76mm OD pole. Light fixture should be protected by In-Built Surge protection of 4kV and External Surge protection of 10kV. Light should be rated with IP65 and IK08. Operating temperature range of light should be -10°C to +50°C. Make: BAJAJ (BGCPNP 45W LED WW- ARCHNER PLUS POST TOP),Havells,Phillips
Supply of Decorative Laser Cut designed 15W Bollard Light of minimum Dimentions of 150mm x 150mm and of height 900mm having colour temp. of 3000K. Light should be made up of Graphite Grey Powder Coated MS Body in Rectangular design shaped emitting light through multiple number of designes cut using Laser technology. Logo / Name of MES to be engraved at the top of all 4 sides of light fixture using Laser cut Technology. Make: BAJAJ (MUSTER BOLLARD), Havells,Phillips
M&L for preparation of old painted surfaces of erected steel tubular swaged poles / Rails/Girder poles of LT over head line ( Except embedded portion) , 9 M long including all MS work mounted on pole , earth protection & water pipe ( if exists) and providing one coat of aluminium paint and providing 04 Nos bands/ straps with two coats of Retro Reflective paint ( black and red 30 cm wide each) from top of plinth block and numbering of poles with white Retro Reflective paint on yellow Retro Reflective piant ground (50mm wide and 100mm high letters) including encircling the letters or figures complete all as specified
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store and compleate all as directed by engr-in-charge.
S&F FRP pole mounting type junction box factory made of size 300x200x105mm with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps, 10 kA, suitable for domestic loading -01 no. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.(MCB shall not be measured and paid separately and shall deemed included in the unit rate)
Taking down of existing unserviceable MCB and S & F Miniature circuit breakers SP, 10 amps, 240 Volts , 10 KA, 'C' curve rating and to be housed in exixting sheet metal enclosures ( distribution boxes) complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
Taking down of existing unserviceable MCB and S & F Miniature circuit breakers TPN, 32/40 Amps, 415 Volts , 10 KA, 'C' curve rating and to be housed in existing sheet metal enclosures ( distribution boxes) complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe medium grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:3:6 type C1 earth pit and Precast RCC cover 40 mm thick in plain cement concrete 1:2:4 type B1 duly reinforced with 8mm dia TMT bars @ 150mm c/c with 10mm dia MS round bar as in lifting handles, mild steel angle iron frame for pit cover made out of 40x40x5mm thick duly painted with two coats of ssynthetic enamel paint over a coat of priner , excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 03 of SSR Part I
Lowering of high mast light assembly from upto 16/12 Mtr high mast,any type,make and wattage, dismantling, checking and taking out of unserviceable/defective parts and components for replacement, and making the light fittings operational to give rated illumination incl cleaning the acrylic/ glass cover and refixing the same after repair/replacement of defective components complete with necessary electrical connection with by providing two single/twin core 2.5 Sqmm PVC sheathed multi stranded aluminium conductor cable of required length and testing complete all as specified and directed.
Note :-Spare parts/components to be replaced shall be measured and paid for separately under respective item of sch 'A'. The cost of greasing of pully, roller, bearing and gear including refixing of rope clamps, adjustment of lock, leaver etc shall be deemed to include the quoted rate.
Supply and fixing post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirtect light IP 65 protection with impact and corrosiion resistant made in cast aluminium with decorative opal poly carbonate diffusercomplete with driver and lamp complete all as specified and directed.
Supply and fixing LED flood light 150 watt 230 volt AC pressure dia cast housing outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver lamp necessary bracket, clamps and nuts & bolts etc required for fixing light fittings on ploe/ wall etc. complete all as directed.
Supply and fix in repaires LT Distribution Panel Feeder Pillar (CPRI approved) Cubicle type, IP-56, outdoor type confirming to IS: 61439 Part I & II factory fabricated made out of outer cover with 3 mm thick CRCA sheet & inner cover with 2mm thick CRCA sheet of suitable size to accommodate all accessories / fittings, compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing MCCBs feeders. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator at an interval of not more than 500 mm throughout the length of the TPN bus bar. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/Epoxy insulators having provision for termination of incoming and outgoing cables. The cubicle shall have a bottom and four legs (400mm long) of size 50x 50x6 mm, The panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphate treatment, front & back opening type, and fixing 2 Nos. Danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and air vent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test assembly certificates for (a) Design verification as per IS/IEC: 61439-1:2011 (b) Tested Carried out from CPRI/ERDA (c)Strength of materials and parts (d)Degree of Protection IP-56/65/66 (e)Clearances and creepage distance (f)Protection against Electric shock and integrity of protective circuits (g) Incorporation of switching devices and components (h)Internal Electrical Circuits and connections (i) Terminals for external conductors (j)Dielectric Properties (k)Verification of Temperature Rise (l) Short-Circuits withstand Strength (m)Mechanical Operation (n)Internal Arc containment test,Contractor should submit all Certificates before executing the job.) Note Panel should have proper wiring for neutral CT
(II) Outgoing :- (i) MCCB 400A, 4P, 50KA, Microprocessor base and neutral CT with ICS=100% ICU - 02 Nos. (ii) MCCB 320A, 4P, 36KA, Microprocessor base and neutral CT with ICS=100% ICU - 01 No. (iii) MCCB 250A, 4P, 36KA, Microprocessor base and neutral CT with ICS=100% ICU - 01 No. (iv) MCCB 200A, 4P, 36KA, Microprocessor base and neutral CT with ICS=100% ICU - 01 No. (v) MCCB 160A, 4P, 36KA, Microprocessor base and neutral CT with ICS=100% ICU - 02 Nos. (vi) MCCB 63A, 4P, 36KA, Microprocessor base and neutral CT with ICS=100% ICU - 01 No.
NOTE:- Make for All Incoming and outgoing switchgear and other LED lamps,meters should be of Make:ABB,SEIMENS,SCHEINDER Drawings of LT panel shall be got approved from GE before placing order for procuring.
M/S Ex Soldiers Mechanical Works
NITHYA INFRATECH
Ramesh Traders Govt Contractors & General OrderSuppliers
Narender Construction
Shikha Enterprises
D S Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .