Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 CrAccepted-AOC | ₹4.9 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹5.0 Cr+₹4.9 L (0.98%)Rejected-Finance | ₹5.0 Cr+₹4.9 L (0.98%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹5.8 Cr+₹89.5 L (18.1%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹5.8 Cr+₹89.5 L (18.1%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹5.9 Cr+₹1.0 Cr (20.4%)Rejected-Finance | ₹5.9 Cr+₹1.0 Cr (20.4%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹6.0 Cr+₹1.0 Cr (20.6%)Rejected-Finance | ₹6.0 Cr+₹1.0 Cr (20.6%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹5.0 Cr
EMD Value
₹5.7 L
Closing Date
15 Jun 2020, 6:00 pmClosed
CE AF BANGALORE
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
CONSTRUCTION OF STATION HQ BUILDING INCLUDING EDUCATION AND ACCOUNTS SECTION AT AFS BEGUMPET
2020_MES_330850_1
801454/E8
Open Tender
Civil Works
Lump-sum
365 days
GE (AF) HAKIMPET
As per NIT
8 documents required · 8 mandatory
₹2,000
Yes
GE (AF) HAKIMPET
₹5.7 L
Yes
CE AF BANGALORE
6 Aug 2020
3 Mar 2020
17 Jun 2020
3 Mar 2020
15 Jun 2020
26 May 2020
3 Mar 2020 - 13 Mar 2020
16 Mar 2020
Amount
REVISED BOQ UPLOADED ON 18 May2020
NOTE: Schedule ‘A’ Part-I to XI are under Ser No. 3.00 to 12.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “Building Works” as listed in Schedule ‘A’ Part–I
Lumpsum price worked out by the contractor for “Internal water supply” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Road/Path/Culvert” as listed in Schedule ‘A’ Part–IV
Lumpsum price worked out by the contractor for “Fencing and Gate" as listed in Schedule ‘A’ Part–V
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part–VI
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part–VII
Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part–VIII
Lumpsum price worked out by the contractor for “External water supply” as listed in Schedule ‘A’ Part–IX
Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part–X
Lumpsum price worked out by the contractor for “Demolition/Dismantling” as listed in Schedule ‘A’ Part–XI
SCHEDULE `A' PART - XIII -Fittings, fixtures and Miscellaneous items is not prepriced by MES. Bidder shall insert their rates in Green filed under Col-6.
INTERNAL WATER SUPPLY S&F 15mm bore health faucet cast copper alloy chromium plated including necessary fittings complete all as specified and as directed.
INTERNAL ELECTRIFICATION Supply and fix and connecting up ceiling fan of size 1400mm sweep complete including with,modular type fan step regulator 120W 2 module, cable 3 core of size 0.5 sqmm from ceiling rose to fan, including writing MES No 2cm height with synthetic enamel black paint complete all as specified and as directed
Note:- Make shall be of Havells ES 50 Premium (5 star rated) or equivalent of makes as listed here-in-after.
Supply and fix and connecting up Heavy duty Exhaust fan of size 300mm sweep 1400 rpm complete,with cable 3 core of size 0.5 sqmm from ceiling rose to fan, provision of 3mm thick bakelite sheet cover including writing MES No 2cm height with synthetic enamel black paint all as specified.Make shall be of Havells Turbo Force /Crompton/Orient heavy duty or equivalent of makes as listed here-in-after.
M&Lfor sub main wiring complete with two runs of 4.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20mm dia rigid non metallic PVC and conduit accessories concealed/ roof/wall all as specified and as directed. Note: Two runs of FRLS cable,1 run of earth continuity conductor cable and one run of non metalic PVC conduit shall be measured as one length/running metre.
M&Lfor sub main wiring complete with four runs of 6.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one runs of 6.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia rigid non metallic PVC conduit and conduit accessories concealed/ roof/wall all as specified and as directed.. Note: Four runs of FRLS cable,1 run of earth continuity conductor cable and one run of non metalic PVC conduit shall be measured as one length/running metre.
M&Lfor sub main wiring complete with four runs of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with two runs of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 50 mm dia rigid non metallic PVC conduit and conduit accessories concealed/ roof/wall all as specified and as directed. Note: Four runs of FRLS cable,1 run of earth continuity conductor cable and one run of non metalic PVC conduit shall be measured as one length/running metre.
Supply, fixing and testing of 4ft LED surface & wall mounted batten LED luminaires , 20 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integral electronic driver fixed complete including all accessories and provision of PVC sheathed 3 core 1.5 Sqmm copper conductor for connection complete all as specified and directed.(a) Make : Havells as per cat No ENDURALINEARNEOBS20WLED830SPCWH/ Wipro cat No LM34-251XXX-2765/ Philips cat No BN150WLED20S-6500 PSEOD GR or equivalent of makes as listed here-in-after.(b) For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.178
Supply, fixing and testing of 2ft LED surface & wall mounted batten LED luminaires , 10 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integral electronic driver fixed complete including all accessories and provision of PVC sheathed 3 core 1.5 Sqmm copper conductor for connection complete all as specified and directed. (a) Make : Havells as per cat No ENDURALINEARNEOBS10WLED830SPCWH/ Wipro cat No LL20-III-XXX-65NE3/ Philips cat No BN021 LED 10S-6500 PSU GRS1 or equivalent of makes as listed here-in-after. (b) For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.178
Supply,fixing and testing 20W High efficient LED Streetlight, pressure Die cast housing alongwith prismatic polycarbonate diffuser and LEDs with secondary optics and IP-65 protection including fixing arrangement and connecting with twin twisted flexible copper conductor cable of size 0.75 sq mm complete all as directed.(a) Make-Bajaj as per cat No- BCLST 20W LED1 V2/ Havells cat No ENDURAPEARLSL 20WLED757SASYTOPC/ Philips cat No BRPO22 LED 20 CW MR S1PSUGR or equivalent of makes as listed here-in-after (b) For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.178
Supply and fixing ceiling surface mounted 2x2 LED down light fitting 33 to 34 watts with 6500 CCT white powder coated CRCA housing with LEDs, seamless front frame with flat white high transmission acrylic cover and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.(a) Make- Bajaj as per cat No BZRSQL GX 34W CW/ Philips cat No RC365B LED33-6500 PSU OD WH/ Havells cat No PLUTOSURFACE 2X2PLS 34WLED840S or equivalent of makes as listed here-in-after (b) For all other mandatory requirements of LED fittings, please refer PS Clause No.43.6 on Sl Page No.178
Supply and fixing fully diffused recessed/mounted 2x2 LED down light fitting 33 to 36 watts with white powder coated and CRCA front cover, HET diffuser provides uniform illumination, CCT (K) 5700, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. (a) Make- Wipro cat No CRCO10R036HP57G1/ Havells cat No ENDURASLIM PRO PLUS-2x2 PLR 28/36W LED-857 MOD/ Philips cat No CRCO-23R036H P65G3 or equivalent of makes as listed here-in-after (b) For all other mandatory requirements of LED fittings, please refer PS Clause No43.6 on Sl Page No.178
S&F telephone socket 2 pin modular complete all as specified and as directed.
S&F TV socket modular complete all as specified and as directed.
S&F MCB 6-32 Amps, SP, 240 Volts, 50 Hz, AC supply, "C" curve, with breaking capacity of 10 kA complete all as specified and as directed.
S&F MCB FP 32 Amps 415 volts 10 KA 50 HZ C curve complete all as specified and as directed.
S&F MCB FP 40 Amps 415 volts 10 KA 50 HZ C curve complete all as specified and as directed.
S&F MCB FP 63 Amps 415 volts 10 KA 50 HZ C curve complete all as specified and as directed.
S&F MCB FP 16 Amps 415 volts 10 KA 50 HZ C curve complete all as specified and as directed.
S&FMCB DB VTPN 4 way double door 415 V AC 50Hz with for MCB FP as incomer and TP,DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete. Make:- Legrand, Cat No - 507725, Schneider Electric Cat No : NBKRENTVDD04 or equivalent of makes as listed here-in-after complete all as specified and as directed.
Earthing complete with galvanized iron earth plate electrode of size 600mmx600mm x 6.3 mm thick buried directly under ground vertically to depth not less than 2.25 meter below ground level with top edge of plate at a depth not less than 1.5 m below ground level connected to and including GI wire 4mm dia and GI protection pipe 15mm dia and light grade connected to and including by means of bolts nuts check nuts and washers made of copper as shown plate no 3 of SSR part 1 to the extent applicable to this item including necessary excavation earth work , PCC 1;3;6 chamber RCC 1;2;4 cover 50mm tick with 6mm TMT bar 100mm center to center watering pipe medium grade 20mm with funnel wire mesh etc. and testing on completion all as specified and as directed.
SEWAGE DISPOSAL S &F SFRC Man hole covers 450 dia with frame (factory made) all as directed by Engeneer-in charge .
S &F SFRC Man hole covers 600 dia with frame (factory made) all as directed by Engeneer-in charge.
FENCING AND GATE Supply and fixing ornamental gate of size 5.50mx2.5m including excavation in hard dense soil ,PCC in sub base RCC M-25 in column /post TMT bars in reinforcement ,mild steel work in pintol hinges ,rendering in cement mortor ,cement base painting to plastered surfaces,painting to mild steel work ,RFR and removal of surplus soil etc.,complete all shown in drawing and all as specified and as directed.
LIGHTING PROTECTION M&L for PCC 1:4:8,type D2 using 40mm graded aggregate and PCC 1:3:6, type C1 using 20mm graded aggregate for errecting air termination rods over roof top complete of size 0.45mx0.30mx0.30m all as specified and as directed.
AIR CONDITIONING Supply, install, connect, test and commissioning of hi wall split units indoor / outdoor complete with cordless remote control unit having 5 star rating with in built air ioniser, bio filter for better indoor air quality etc. with Invertor technology of capacity 1.5 TR, operated using environment friendly refrigerant gas R32, inclusive of suction and discharge lines of suitable size of copper tube, copper wires 4 sqmm including neccessary brazing and providing nitrile tubing over gas circulating copper tubes and neatly tying the ends with PVC insulating tape and mounting on suitable bracket with suitable drain pipe for disposal of waste water upto ground level and inclusive of suitable GI stand for outdoor unit, voltage stabilizer 4KVA capacity, wall mounting type having featurers such as intelligent time delay system, low and high voltage cut-off protection, latest IC technology to protect from power fluctuations,thermal over load protection, wide input variation between 170V to 270V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% complete all as specified and as directred by the Engineer in Charge. Make : Carrier (Superia) or equivalent in Voltas/ Bluestar or equivalent of makes as listed here-in-after
Supply, install, connect, test and commissioning of hi wall split units indoor / outdoor complete with cordless remote control unit having 5 star rating, with in built air ioniser, bio filter for better indoor air quality, leakage detector etc. with Invertor technology of capacity 2 TR, operated using environment friendly refrigerant gas R32, inclusive of suction and discharge lines of suitable size of copper tube, copper wires 6 sqmm including neccessary brazing and providing nitrile tubing over gas circulating copper tubes and neatly tying the ends with PVC insulating tape and mounting on suitable bracket with suitable drain pipe for disposal of waste water upto ground level and inclusive of suitable GI stand for outdoor unit, voltage stabilizer 5KVA capacity, wall mounting type having featurers such as intelligent time delay system, low and high voltage cut-off protection, latest IC technology to protect from power fluctuations,thermal over load protection, wide input variation between 170V to 270V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% complete all as specified and as directred by the Engineer in Charge. Make : Carrier (Superia) or equivalent in Voltas/ Bluestar or equivalent of makes as listed here-in-after
Taking down in door unit of split Air conditioner upto 1.5TR capacity carefully from the installed position dismantling the complete unit, applying blower to remove the complete dust, cleaning all the components with suitable cleaning agent, coombing the condensor coil for better efficiancy and re assembling the complete unit with voltage stabilizer and re installed in its original position or new location and testing on completion complete all as directed by the Engineer - in - Charge.
Description all as per item No 41.00 above but capacity upto 2TR
Description all as per item No 41.00 above but outdoor unit of split AC upto 1.5TR capacity
Description all as per item No 41.00 above but outdoor unit of split AC upto 2TR capacity
M&L for filling up & charging of R-410a refrigerant to the cooling appliances all as specified and directed by Engineer - in - Charge
M&L for filling up & charging of R-22 refrigerant to the cooling appliances all as specified and directed by Engineer - in - Charge
M&Lfor sub main wiring complete with two runs of 6.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia rigid non metallic PVC conduit and conduit accessories concealed/ roof/wall all as specified and as directed.. Note: Two runs of FRLS cable,1 run of earth continuity conductor cable and one run of non metalic PVC conduit shall be measured as one length/running metre.
S&FSingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB all as specified and directed by Engr in charge.
EXTERNAL WATER SUPPLYConstruction of valve chamber having inner dimension 750x750x750 mm suitable for 50mm dia valve PCC 1:4:8 type D2 for foundation, brick work wall in cement mortar (1:4), PCC 1:2:4 type B1 for copping, rendering plaster in CM 1:4, 15mm thick including provision of MS Sheet top cover 3 mm thick with brazing of MS flat of size 25mmx4mm at edges and in diagonal and angle iron base frame of 40x40x3mm painting with two coat of synthatic enamel paint over a coat of red oxide primer and locking arrangements including necessary excavation earth work complete all as specified.
Cutting existing 100mm bore cast iron pipes in position and inserting new tee branch connection for PPR pipe 50mm dia including draining out water, excavation etc complete all as specified and as directed. NOTE:- Cost of CI Tee, run lead joint etc shall be deemed to be included in the quoted rate.
EXTERNAL ELECTRIFICATION M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including 32x6 mm galvanized iron strip as earth lead, extended upto 7.5 m or upto test terminal point, drawn through 40mm dia med. gr. GI pipe for protection of galvanized iron strip in the ground, further connecting with suitable size of earthing strip to LT Panel, Transformer, Distribution boards etc., including excavation, earth work, Charcoal & Salt all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, wire net, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt-I, complete all as specified and as directed.
Dismantling of MCB DB 4/8 way with MCB's by disconnecting electric supply complete all as directed.
Taking down light fittings of any pattern complete all as directed.
Taking down carefully unserviceable copper sub main wiring of 4/6sqmm with all conduits and accessories complete all as directed.
M & L for Road cutting / hard standing for taking up or laying of LT UG cable upto a depth of 15 cm, after laying of cable, well ramming to the excavated soil and repair the exvcavated portion of road as existing or by providing suitable mixture of PCC all as specified and as directed.
S&F 4 pole MCCB 250 Amp, 50 Hz, 415V, rupturing capacity 35 KA in sheet metal enclosure with necessary fixing arrangements and fixtures all as specified and directed at site.
M&L for feeder pillar Box cubical type, factory made suitable for 3 phase, 415 Volts, 50Hz system with 200 Amps capacity aluminium bus bar, out door type, factory fabricated with 3mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable opening for vent and cable entry (CPRI type tested) with angle iron of size 50x50x5mm thick, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish complete along with following accessories. (a) MCCB, 4 pole, 100A, 35KA - 01 No (in coming) (b) MCCB, 4 pole, 100A, 25KA - 02 No (Out going-1, Spare-1) (c) Onload changeover, TPN 100A (d) Digital display VAF Panel meter - 01 No (e) LED indicator RYB - 01 No (f) Internal wiring with PVC insulated copper cable - 01 Job (g) suitable CT's all as specified and directed
M&L for feeder pillar Box cubical type, factory made suitable for 3 phase, 415 Volts, 50Hz system with 200 Amps capacity aluminium bus bar, out door type, factory fabricated with 3mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable opening for vent and cable entry (CPRI type tested) and spare terminal for MCCB - 01 No with angle iron of size 50x50x5mm thick, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish complete along with following accessories. (a) MCCB, 4 pole, 100A, 35KA - 01 No (in coming) (b) MCCB, 4 pole, 100A, 25KA - 02 No (Out going-1, Spare-1) (c) Digital display VAF Panel meter - 01 No (d) LED indicator RYB - 01 No (e) Internal wiring with PVC insulated copper cable - 01 Job (f) suitable CT's all as specified and directed
Supply and fixing LED street light fitting of capacity 70W heat resistant glass IP65 protection, suitable drive along with GI bracket with suitable clamp and nut, bolt and washer complete all as specified and as directed.(a) Make : Havells LHFAXU7PN6J070 or equivalent in Phillip/ Crompton or equivalent of makes as listed here-in-after. (b) For all other mandatory requirements of LED fittings, please refer PS Clause No.51.5 on Sl Page No.193.
M&L for Twin core 2.5 Sq mm PVC insulated copper conductor for street light fittings.
M&L for Factory made out door type street light loop-in and loop out box made out of 2 mm thick CRCA sheet, of size 220mm x 180mm x 150mm with pre-treated & powder coated comprising 3 Nos bus bar, insulators, connectors etc. and with one SP MCB 6A ''C'' Series, one PVC way connector etc including suitable size clamps, nut bolts & washers complete including suitable clamps for fixing all as specified and directed.
M&L for supply and spread riddled earth as permitted by IS 1255 in trenches as in cable cushioning all as specified and directed. Note: For the purpose of measurement only punned thickness will be considered for payment.all as specified and directed.
M/s RL Pareek
M/s. P S REDDY
UNITED ENGINEERS CORPORATION
R. Wadhumal and Sons
B.N.S Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .