Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹13.9 L Quoted ₹16.9 L | L1 | Accepted-AOC Found lowest and reasonable |
| 2 | L2₹17.5 LRejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | ₹17.5 L | L2 | Rejected-Finance In order but L2 |
| 3 | L3₹18.5 LRejected-Finance | ₹18.5 L | L3 | Rejected-Finance In order but L3 |
| 4 | L4₹18.5 LRejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | ₹18.5 L | L4 | Rejected-Finance In order but L4 |
| 5 | L5₹21.7 LRejected-Finance | ₹21.7 L | L5 | Rejected-Finance In order but L5 |
| Sl No | Description | Qty | Unit | M/S JPS Electrical Engineer & Contractor L6 | Jain Traders L4 | Niyana Innovation Works L7 | KUKREJA BROTHERS L3 | PK ENTERPRISES L1 | BHAGWAN DAS & Co L8 | SIYA ASSOCIATES L2 | himalayan edge enterprises L9 | NITHYA INFRATECH L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fixing LED street light fitting 70/72 watts , 140 V - 270 V , 50Hz AC outdoor type with high pressure die cast alluminium housing with top opening service and heat resistant complete with driver and with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection , Light sensing with auto on off as per ambient light conditions, High efficiency long life LED package modules on MCPCB with LED lumen efficacy of >110 lumen per watt, Electronic Driver Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection, Over Voltage protection, 10 kV surge protection, Surge Voltage protection & other safety tests as per IS 15885 Part-2/Sec13 completed to driver with superier finish with top maintainable driver compartment complete all as specified and directed. | 125 | Each | 2,529 ₹3.2 L | 1,549 ₹1.9 L | 2,000 ₹2.5 L | 1,850 ₹2.3 L | 1,900 ₹2.4 L | 2,500 ₹3.1 L | 1,511 ₹1.9 L | 3,200 ₹4 L | 1,700 ₹2.1 L |
| 2.00 | Taking out unserviceable Street lights any type any size from poles incl any cable used for connection complete all as specified and directed. | 110 | Each | 49 ₹5,390 | 39 ₹4,290 | 10 ₹1,100 | 20 ₹2,200 | 25 ₹2,750 | 20 ₹2,200 | 5.11 ₹562.10 | 20 ₹2,200 | 10 ₹1,100 |
| 3.00 | S&F pole mounting type junction box factory made of minimum size 300 x200x100mm of FRP sheet duly powder coated with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on SMC /porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps, 10 kA suitable for domestic loading , -01 no. including mild steel flat iron clamp and and supporting flat Iron made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. | 125 | Each | 949 ₹1.2 L | 849 ₹1.1 L | 1,100 ₹1.4 L | 700 ₹87,500 | 700 ₹87,500 | 600 ₹75,000 | 751 ₹93,875 | 1,600 ₹2 L | 850 ₹1.1 L |
| 4.00 | Taking down Old unsv Aluminium Cable 2 Core 4 Sqmm connected from overhead conductor to the street light complete all as specified and directed. | 125 | RM | 1.9 ₹237.50 | 4.49 ₹561.25 | 5 ₹625 | 5 ₹625 | 30 ₹3,750 | 30 ₹3,750 | 5.11 ₹638.75 | 100 ₹12,500 | 10 ₹1,250 |
| 5.00 | S&F one run of three core 2.5 Sqmm x 3 core (nominal area) PVC insulated and PVC sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Confirming to IS : 7098 drawn through existing tubular pole for connecting to street light and pole JBs complete as all specified and as directed. | 1,125 | RM | 89 ₹1.0 L | 49 ₹55,125 | 65 ₹73,125 | 45 ₹50,625 | 61 ₹68,625 | 300 ₹3.4 L | 81 ₹91,125 | 65 ₹73,125 | 90 ₹1.0 L |
| 6.00 | Material and labour for light grade GI pipe 40 mm bore of approx. 1.5 mtr length and fixed to pole with FI 40mm x 6mm clamps, 02 nos and suitable size necessary nuts & bolts complete set with painting of two coat red oxide and over a coat of red oxide and aluminium paint complete all as specified and directed. | 250 | Each | 299 ₹74,750 | 189 ₹47,250 | 500 ₹1.3 L | 250 ₹62,500 | 180 ₹45,000 | 300 ₹75,000 | 171 ₹42,750 | 500 ₹1.3 L | 140 ₹35,000 |
| 7.00 | Taking out Existing Street / security lights Bracket any type and size & Supply and fixing of mounting bracket made of 40 mm bore (or higher size to suit the opening of fitting) light grade GI pipe of approx 1.5 mtr length bent to shape and fixed to pole with FI 40mm x 6mm clamps, 2 nos and suitable size necessary nuts & bolts ,including Bracket complete set painting of two coat red oxide and aluminium painted including of fixing of existing street lights complete all as specified and directed. | 125 | Each | 399 ₹49,875 | 249 ₹31,125 | 500 ₹62,500 | 250 ₹31,250 | 200 ₹25,000 | 550 ₹68,750 | 171 ₹21,375 | 500 ₹62,500 | 125 ₹15,625 |
| 8.00 | M&L for taking out unsv Steel tubular pole including all accessories and Supplying, transporting to site, erecting, and fixing in position, steel tubular swaged and welded poles of Overall height 9 metres, type 410 SP-31, IS-2713 marked, with cast iron base plate (fillet welded to poles), pole cap / finial taper plug, bolts, nuts, washers etc,duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and painting 05 nos band /strips with fluorescent , Black/ Red/ White/ Green and Black synthetic enamel paint ( 30 cm wide each) at a distance of 30 cm from plinth block and numbering of poles, complete all as specified and directed.
(Note:- 1.- Excavation , Earth work and PCC required for pole fixing will be measured & paid seperately under respective item of schedule 'A'. 2- Poles shall be swaged and welded at manufacturer’s factory and not at site. The inner surface shall be factory painted) , | 15 | Each | 16,789 ₹2.5 L | 12,449 ₹1.9 L | 14,500 ₹2.2 L | 12,000 ₹1.8 L | 11,200 ₹1.7 L | 16,500 ₹2.5 L | 11,111 ₹1.7 L | 12,000 ₹1.8 L | 12,500 ₹1.9 L |
| 9.00 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth and getting out in Soft/Loose soil including trimming sides and bottom of trenches complete all as specified and directed. | 0.41 | Cum | 89 ₹36.49 | 59 ₹24.19 | 150 ₹61.50 | 150 ₹61.50 | 3,000 ₹1,230 | 200 ₹82 | 51 ₹20.91 | 4,800 ₹1,968 | 180 ₹73.80 |
| 10.00 | M&L for PCC (1:4:8)type D2 with 40 mm graded stone aggregate infoundation(below pole ) complete all as specified and directed. | 0.75 | Cum | 3,479 ₹2,609.25 | 2,989 ₹2,241.75 | 4,000 ₹3,000 | 4,000 ₹3,000 | 4,000 ₹3,000 | 4,000 ₹3,000 | 2,511 ₹1,883.25 | 4,500 ₹3,375 | 3,500 ₹2,625 |
Updated dates
Tender Value
₹38.6 L
EMD Value
₹77,300
Closing Date
19 Feb 2026, 6:00 pmClosed
GE (U) Meerut Cantt
Roorkee road Meerut Cantt
SPL REPAIR/ REPLACEMENT OF LT POLES, LT OVERHEAD LINES CONVERSION FOR UG CABLE, LT PANEL AND ALLIED WORKS AT VSD MEERUT CANTT UNDER GE (U) MEERUT CANTT.
2026_MES_749650_1
8785/E8
Open Tender
Electrical and Maintenance Works
180 days
Meerut Cantt
Please refer Tender documents.
12 documents required · 12 mandatory
₹500
GE (U) Meeerut Cantt
₹77,300
Yes
7 Apr 2026
22 Jan 2026
26 Feb 2026
22 Jan 2026
19 Feb 2026
5 Feb 2026
Supply and fixing LED street light fitting 70/72 watts , 140 V - 270 V , 50Hz AC outdoor type with high pressure die cast alluminium housing with top opening service and heat resistant complete with driver and with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection , Light sensing with auto on off as per ambient light conditions, High efficiency long life LED package modules on MCPCB with LED lumen efficacy of >110 lumen per watt, Electronic Driver Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection, Over Voltage protection, 10 kV surge protection, Surge Voltage protection & other safety tests as per IS 15885 Part-2/Sec13 completed to driver with superier finish with top maintainable driver compartment complete all as specified and directed.
Taking out unserviceable Street lights any type any size from poles incl any cable used for connection complete all as specified and directed.
S&F pole mounting type junction box factory made of minimum size 300 x200x100mm of FRP sheet duly powder coated with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on SMC /porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps, 10 kA suitable for domestic loading , -01 no. including mild steel flat iron clamp and and supporting flat Iron made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down Old unsv Aluminium Cable 2 Core 4 Sqmm connected from overhead conductor to the street light complete all as specified and directed.
S&F one run of three core 2.5 Sqmm x 3 core (nominal area) PVC insulated and PVC sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Confirming to IS : 7098 drawn through existing tubular pole for connecting to street light and pole JBs complete as all specified and as directed.
Material and labour for light grade GI pipe 40 mm bore of approx. 1.5 mtr length and fixed to pole with FI 40mm x 6mm clamps, 02 nos and suitable size necessary nuts & bolts complete set with painting of two coat red oxide and over a coat of red oxide and aluminium paint complete all as specified and directed.
Taking out Existing Street / security lights Bracket any type and size & Supply and fixing of mounting bracket made of 40 mm bore (or higher size to suit the opening of fitting) light grade GI pipe of approx 1.5 mtr length bent to shape and fixed to pole with FI 40mm x 6mm clamps, 2 nos and suitable size necessary nuts & bolts ,including Bracket complete set painting of two coat red oxide and aluminium painted including of fixing of existing street lights complete all as specified and directed.
M&L for taking out unsv Steel tubular pole including all accessories and Supplying, transporting to site, erecting, and fixing in position, steel tubular swaged and welded poles of Overall height 9 metres, type 410 SP-31, IS-2713 marked, with cast iron base plate (fillet welded to poles), pole cap / finial taper plug, bolts, nuts, washers etc,duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and painting 05 nos band /strips with fluorescent , Black/ Red/ White/ Green and Black synthetic enamel paint ( 30 cm wide each) at a distance of 30 cm from plinth block and numbering of poles, complete all as specified and directed. (Note:- 1.- Excavation , Earth work and PCC required for pole fixing will be measured & paid seperately under respective item of schedule 'A'. 2- Poles shall be swaged and welded at manufacturer’s factory and not at site. The inner surface shall be factory painted) ,
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth and getting out in Soft/Loose soil including trimming sides and bottom of trenches complete all as specified and directed.
M&L for PCC (1:4:8)type D2 with 40 mm graded stone aggregate infoundation(below pole ) complete all as specified and directed.
M&L for cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of pole etc. (around the poles in pit) complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate for coping of poles including necessary form work, fair finishing to exposed surfaces using extra cement, complete all as specified and directed.
Dismantling old existing ACSR conductor of any type/size complete all as specified and directed.
Dismantling old existing MS cross arms of any type/shape complete all as specified and directed.
Dismantling old existing Insulators of any type/shape complete all as specified and directed.
Supply, laying, jointing, testing and commissioning LT underground cables 16 sqmm x 4core, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098 (marked, laid in trenches / ducts / fixed on poles / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed. (Note;- Rate quoted includes terminal Lugs / road cutting/ floor cutting/ Inter locking floor and making good damaged portion matching with existing surface with all existing finishes.) complete all as specified and directed. (Note:- Excavation , earth work, sand, brick & GI Pipe will be measured and paid seperately under respective item of Schedule 'A').
All as per ser item No 16 but but cable size 50 Sqmm 3.5 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in Soft/Loose soil including trimming sides and bottom of trenches complete all as specified in the following type of soils complete all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified in the following type of soils complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified complete all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables complete all as specified and directed.
M & L for Bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as directed.complete all as specified and directed.
Supply and laying galvanised steel tubing, light grade, 50 mm bore, IS-1239 marked with all fittings (IS marked) and laid in trenches / under roads / under PCC/ under interlocking floor/ in drains / fixed to poles or walls ( with required size flat iron clamp bolts, nuts and washers ) complete all as specified and directed.
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any damage to existing cables of any type shall be made good by the Bidder without any extra cost to department complete all as specified and directed.
M&L for Cutting of worn-out / burnt aluminium cable terminal lugs from the LT cable , crimping of new aluminium cable core and fixing with transformer/ Panel MCCB terminal/ FPB/ JB/ pole/DBs/ stud including cutting/ dressing of cable, disconnecting under ground / OH line cable conductor , cutting down worn-out portion and refixing with suitable lugs complete , including under ground cables of any type and size for repairs including taking out underground cable loop from ground and making connections of restoration of electric supply complete all as specified and directed. Note:- (Excavation, earth work , taking out cable protection covers, and sand cushion and relaying the same shall be deemed included in the unit rate quoted by Contractor)
M&L for preparation of old painted surfaces steel tubular swaged poles, 9 M long including all MS work mounted on pole , earth protection & water pipe ( if exists) including bracket(s), single or double of size 1.5m x 40/50 mm pipe ) and providing one coat of aluminium paint and providing 05 Nos bands/ straps with Two coats of retro reflective paint ( Black, Green and 30 cm wide each) from top of plinth block and numbering of poles with white reflective paint (50mm wide and 100mm hight letters) including encircling the letters or figures complete all as specified and directed.
Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK), outdoor type, minium size 900 x 600x 800mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 350 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm CRCA sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & back door opening type, with aprons for cable entry, with front door of double door shutter type and locking arrangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-7098 marked of adequate size but not less than 2.5 Sqmm. Busbar connected to MCCB should be 1.5 time rated cap of MCCB and MCCB fixed in vertical position. Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for Feeder pillar box. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming new /existing cables of any size by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and crimping suitable size lugs for terminal connections of cables, All out going feeders shall be connected and fixing danger notice plate made of 1.6mm thick mild steel sheet, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door etc with voltage and danger indiated in Hindi and English complete all as specified and directed., The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates and Panel Builder should submit all Certificates before executing the job.)
(II) Outgoing :- (i) MCCB 4 Pole, Thermal Magnetic Based 100 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -01 No along with Spreader terminals. (ii) MCCB 4 Pole, Thermal Magnetic Based 63 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -01 No along with Spreader terminals
Supply, installing, testing and commissioning, factory made and tested , LT Panel (KIOSK), outdoor type, minium size 900 x 600x 800mm and platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 300 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and SMC/made of 3.15mm CRCA MS sheet and 50x50x5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with front door of double door shutter type and locking arrangement , internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-7098 marked of adequate size but not less than 2.5 Sqmm. Busbar connected to MCCB should be 1.5 time rated cap of MCCB and MCCB fixed in vertical position. Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for Feeder pillar box. The platform shall be such that it is of a height 45 cm above the nearest road level. complete all as specified and directed including connections of all out going/in coming new /existing cables of any size by drawing /digging out cable from loops in trenches out side the Bldg including of necessary excavation and earth work as required and relaying the cables with retrieved bricks and crimping suitable size lugs for terminal connections of cables, All out going feeders shall be connected and fixing danger notice plate made of 1.6mm thick mild steel sheet, of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front & back door etc with voltage and danger indiated in Hindi and English complete all as specified and as directed by Engr-in-Charge , The scope of work includes the following: (NOTE:-LT Panel board should be as per IS/ICE 61439-part I&II Type Test certificates and Panel Builder should submit all Certificates before executing the job.)
(II) Outgoing :- (i) MCCB 4 Pole, Thermal Magnetic Based 100 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -01 No along with Spreader terminals. (ii) MCCB 4 Pole, Thermal Magnetic Based 63 A, Breaking capacity 16 KA, 415 V, 50 Hz with OL, SC protection, -02 No along with Spreader terminals
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
technical_839561.pdf
techsummary_839561.pdf
finance_839561.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
Tender8785.pdf
Tender Documents • 1.43 MB
BOQ_839561.xls
BOQ • 0.33 MB
CreditSchedule8785.pdf
Tender Documents • 0.15 MB
PS8785.pdf
Additional Documents • 0.71 MB
AllMakes8785.pdf
Additional Documents • 0.77 MB
Download all tender documents and submit your bid