| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC Being L-1 and reasonable rate | |
| 2 | L-2₹10.4 L+₹1.0 L (10.7%)Rejected-Finance | L-2 | Rejected-Finance Being not L-1 | |
| 3 | L-3₹12.3 L+₹2.8 L (30.1%)Rejected-Finance | L-3 | Rejected-Finance Being not L-1 | |
| 4 | L4₹14.9 L+₹5.5 L (57.9%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance Being not L-1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
14 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda
REPAIR/MAINT OF VCBs/ OCBs ETC AND ALLIED WORK AT E/M INSTALLATIONS AT BATHINDA MIL STN
2023_MES_579506_1
CWE BTD 8143/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bathinda Mil Stn
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (U) Bathinda
₹30,000
Yes
27 Mar 2023
7 Feb 2023
16 Mar 2023
7 Feb 2023
14 Mar 2023
25 Feb 2023
8 Feb 2023 - 23 Feb 2023
Amount
Carrying out calibration of HT VCB panel of make: ABB/ SIEMENS/ CROMPTON, after taking proper shut down and disconnecting the cables from panel and VCB Breakers, calibration of over fault relay, earth fault relay, checking of alignment of VCB isolating contacts, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decorbonising of panel, bus section & circuit section including incoming/ outgoing cable and necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of worn-out/ defective spares like tension springs, tortion springs, nut bolts, washers of suitable size, lingers etc, under the supervision of M/s ABB or authorised dealer/ representative and refitting the panel in its original position and testing entire satisfaction of Engineer-in- charge. Note: (i) The quoted Rate shall be deemed to include all minor spares etc. (ii) Any burnt out/ defective items like moving/ fixed contracts, tripping coils, earth fault relay etc. will be measured and paid separately under appropriate item of BOQ. (iii) Spare parts required other than mentioned here-in-after shall be deemed to be including in the quoted rate. (iv) The calibration test certificate to be submitted after servicing & testing in front of Engr-in-charge.
M& L for maintenance and overhauling of 11 KV VCB including opening, checking, cleaning with CTC, cleaning wiping of insulating components, primary & secondary circuit, spouts, bus bars, supports, CT,PT, check oil for leakage, cleaning contact tips, cover the exposed portion of bus bar with HT tape & heat shrinkable sleeves, cleaning of bushes, spout insulators for visible crack, tightness old fasteners holding moving contacts, check & correct the buffer gap adjustment & mechanism settings, testing , cleaning & overhauling of complete operating mechanism for smooth functioning, checking of control panel wiring for operation & protection for tripping & closing & rectifying the defects including Deoxidizing of all electrical contacts replacement unserviceable wiring with ferrule & lugs, reassembling & testing of complete VCB all as directed. Note:-(i)Required part for replacement will be measured and paid under relevant item ser No. 3 to 27 as supply only. (ii)Cost of labour & cleaning material like Urethane, Gasket remover, lubricant etc for replacement is deemed to be included in quoted rate.
Supply only Shunt trip coil 220 /110volts DC
Supply only Closing coil 220/110 volts DC
Supply only monoblock assembly 600m suitable for ABB/CG/Siemens make breaker.
Supply only 24 Pin Plug assembly suitable for ABB/CG/Siemens make HT breaker.
Supply only cable stem article No 1VYN400901-BH suitable for ABB/CG/Siemens make HT breaker
Supply only contact system for VD4-630A (12 finger) suitable for ABB/CG/Siemens make HT breaker
Supply only front cover assembly suitable for HT breaker.
Supply only Aux switch suitable for ABB/CG/Siemens make HT breaker
Supply only spring drum V4205 suitable for ABB/CG/Siemens make HT breaker
Supply only Spring V4207 suitable for ABB/CG/Siemens make HT breaker
Supply only Roller Chain V4208 suitable for ABB/CG/Siemens make HT breaker
Supply only Torsion Spring V4710/4711 suitable for ABB/CG/Siemens make HT breaker
Supply only Lever Assembly V6014 suitable for ABB/CG/Siemens make HT breaker
Supply only Motor cut off switch suitable for ABB/CG/Siemens make HT breaker
Supply only Spring charging motor for ABB/CG/Siemens make HT breaker.
Supply only On Off Indicator (Display) V6061 suitable for ABB/CG/Siemens make HT breaker. Make:- ABB/CG/Siemens
Supply only HT self fusing tape insulation heavy duty suitable for insulation of 11 KV bus bar (38mmx0.76mmx10.0m). Make : Scapa/3M/Stanbac
Supply only insulation adhesive Urethane Isolation suitable for air drying conformal for coating in Electrical equipments, battery terminals, 11 KV bus bar etc in 300 ml bottle complete all as specified and directed by Engineer-in-Charge
Supply only bus bar insulator 11KV
Supply only push button assembly suitable for make:- CG/ABB/Siemens complete all as specified and directed by Engineer-in-Charge
S & F breaker control switch (Trip-Neutral-Close) 4 pole/4 Terminal 660 V AC / DC pistol grip type complete all as specified and directed by Engineer-in-Charge. Make : Switron or other make as approved by Accepting Officer
Supply only vacuum interrupter 800/630 Amps, 11KV rating, suitable for ABB/CG/Siemens make VCB, per phase per interrupter all as required
Supply only fixed contact assembly as per sample for ABB/CG/Siemens VCB make HT panel of 1200/800/630 Amps 11KV rating
Supply only CRC-2-26 power spray in 400ml bottles complete all as specified and directed by Engineer-in-Charge
Supply only HT insect killer power spray in 450ml bottles complete all as specified and directed by Engineer-in-Charge
S & F in replacement of LED indicator lamp 220 Volt DC lamp type with holder base in different colours complete all as specified
M & L in replacement of Flag coil for RASVP relay type ICM21P A : 0.5-2.0 at 220V DC supply complete all as specified and directed by Engineer-in-Charge
S & F in replacement of 220 Volt DC Contactor with 2 No+2NC complete all as specified
S & F in replacement 12 KV, VCB panel Spout suitable for ABB VD4, Rating 800 Amps, made of fiber reinforced material for R,Y,B phases complete all as specified
S & F in replacement heater assembly suitable for moisture control in VCBs as per sample complete all as specified
M & L in replacement of PF meter digital type (4 digit) 1A/5A and 110V with built-in Transducer accuracy class + 2o, size 96x96 mm complete all as specified and directed by Engineer-in-Charge
M & L in replacement of Digital voltmeter, DC, with phase range 200 mV to 600V with built in resistance of size 96x96mm, accu class 0.5 complete all as specified and directed by Engineer-in-Charge
M & L in replacement of Ammeter, digital type, 96x96mm with aux supply 220V complete all as specified and directed by Engineer-in-Charge
M & L in replacement of Rubber gasket double ended flexible type suitable for mounting of glass in HT panel/metering window complete all as specified and directed by Engineer-in-Charge
S & F in replacement of Current transformer (CT) ratio 400/200/5-5A, 50 Hz, 15 VA, accuracy class-I & 5P-10 , short cut time 18.4 KA for 1 sec, as per IS-2705 epoxy type suitable for 11 KV, VCB breaker including all necessary fixing arrangements and proper wiring and connections complete all as specified and directed by Engineer-in-Charge
S & F in replacement of Current transformer (CT) ratio 200/100/5-5A, 50 Hz, 15 VA, accuracy class-I & 5P-10 , short cut time 18.4 KA for 1 sec, as per IS-2705 epoxy type suitable for 11 KV, VCB breaker including all necessary fixing arrangements and proper wiring and connections complete all as specified and directed by Engineer-in-Charge
S & F 11KV potential transformer PT ratio 11000/110V accuracy class 0.5, 50 VA, indoor type, epoxy resin cast, strut type single stage suitable for power measurement current monitoring and relay protection in power system with rated frequency 50 Hz and rated voltage 10 kV all as specified and directed
M & L for including removing of old words on existing VCB panel paste fidder wise CTs ratio & fidder name sticker by using radium letter / No the height of the worked minimum 5 CMs & maximum 30 letters complete all as specified
M & L in replacement of Danger notice plate of 1.6mm thick mild steel sheet of size 25x20 cm, pasting with Sticker in radium red colour with writing 11000 KV, figures and conventional skull and bones size, for HT 11000 volts complete all as specified and directed by Engineer-in-Charge
M & L in replacement of MCB SP 'C' curve 6 to 32 Amp for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge
M & L in replacement of MCB SPN 'C' curve 6 to 32 Amp for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge
M&L for preparation of the old painted surfaces of HT VCB panel of any size, any description and in any position including complete removal of old paint either by hand scrubbing or by blow lamps, applying necessary filler coat and scraping as required and applying two coats of grey colour synthetic enamel paint over a coat of zinc chrome primer using spray machine complete all as directed.
S & F in replacement of adjusting insulator suitable for 630 Amp VCB complete all as specified and directed by Engineer-in-Charge. Make : CG/ABB/Siemens
M&L for CPRI tested Indian / International Standards IS: 13573/1992/IEC: 60502/ CENELEC; HD 628.1 & 629.1/ 1EEE; 48/VDE; 0278 Cold shrinkable end termination joint indoor type dielectric strength 15 KV/mm, tensile strngth 1x10E12 N/Sqmm, Elogation 300%, Volm Resist 1x10E11 Ohm.cm suitable for HT XLPE cable of size 50 to 95 sqmm 3 core armoured 11000 volt grade heavy duty
All as per item No 46 above but suitable for cable of size 120 to 185 Sqmm 3 core armoured 11000 volt grade heavy duty
All as per item No 46 above but suitable for cable of size 240 to 300 Sqmm 3 core armoured 11000 volt grade heavy duty
S & F of nominal 2.5mm + 10% thick insulated synthetic Mat conforming to IS 15652:2006 alongwith suitable adhesive/chemibound, Pu resin, waterproofing compound and sealing material and similar tape of matching colour and matching design, tapes should be used to maintain aesthetic look of the insulation over the joints and corner as per service recommendation and suitable for Class-B upto 11KV with HT trolley movement all as specified and directed by Engineer-in-Charge.
S & F in replacement maintenance free battery, 12 Volt, 150 AH lead acid type suitable for inverter purpose complete all as specified and as directed.
S & F in replacement maintenance free battery, 2 Volt, 40 AH lead acid type suitable for inverter purpose complete all as specified and as directed.
S&F in replacement 24 Volt pure sine wave inverter of 2 kVA DIP switch, auto mode 50 HZ, 6 stage charger for large battery life, input voltage 100 to 280 V, low cut recovery input voltage 90 V, high cut input voltage 280V, recharge time max 8 hrs, for 2 battery system, battery boost system, battery charging current 15A, compatible for sealed maintenance free lead acid tubular battery protection against high and low voltage overload, with onsite 36 months warranty complete all as specified. Make- Microtek/Luminous/Sukam
Supply only digital inverse current protection / control relay suitable to work on 24V/12V DC supply as per sample of HT panel of 800/630 Amp, 11 KV rating VCB of make ABB/CG/Siemens. Make of relay Ashida ADR 241 A/Micom 642/ Crompton Aegis FG 111X1/Siemens 7SR2102.
S & F in replacement copper bus bar 60 sqmm cross sectional area for connecting bus bar complete all as specified and directed
S & F in replacement of HT feeder pillar box factory made cubical type dust and vermin proof, outdoor type, both side opening of size 110 x 100 x 60cm of CRCA sheet 3 mm thick powder coated, machine pressed front opening in two halves with rubber gasket/bedding, locking arrangement with sliding bolt including aluminium bus bar of size 50 x 10 mm and 80 cm long 3 strips mounted on HT insulators. Each strip should be mounted minimum two insulator and nut bolt, panel shall be mounted on angle iron frame including heat shrinkable sleeve and legs made from angle iron of size 50 x 50 x 6 mm and legs 40 cm long duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer and including grouted in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete incoming/outgoing cable and earth work such as excavation and removal of surplus soil etc complete all as specified and directed.
Taking down carefully VCB from the position, after disconnecting the incoming and out going cable connections from the panel board and removing the panel from existing location, loading/unloading, transporting/ shifting from site to other location for reuse including reconnecting HT cable and control circuit complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F MS plates (plain or chequerred) channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment with riveted, bolted or welded attachment of steel conforming to Fe-410-W, Gde E-250, Quality B a in flooring and it supporting members foundation etc all as specified and as directed
Demolition of cement concrete of any description and in any position not otherwise specific all provided for complete all as specified.
M & L for PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in coping , concrete on floor/ wall etc complete all as specified
M & L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick/ concrete surfaces and finishing the surface even & smooth with using extra cement complete all as specified
M & L for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32x6 mm, as earth lead by means of bolts, nuts, check nut and washers of galvanized steel, protected by and including GI pipe 40 mm bore light grade and connected to main switch / VCB panel/ control pale and provision of test point as directed and including concrete pit in PCC (1:3:6) type C-1 pre cast RCC (1:1.5:3) type A-1 cover slab of size 54x54x5cm re-inforce with 4mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8 mm dia TMT bar embedded in pre cast cover slab, wire mesh funnel, 20mm bore GI pipe medium grade for watering, charcoal and slat in alternative layers of 15cm thick all around the electrode, including necessary excavation and earth work in any type of soil complete all as shown in electrical plate No. 3 of SSR part-I and testing on complete all as specified and directed
M & L for earth continuity conductor or main earthing lead fixed to pole/ wall on insulators or recessed or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by using 32 x 6mm galvanised iron strip complete
Supply, installation, testing & commissioning in replacement of old electromagnet type relay with new numerical power transformer feeder relay for Over current, Recloser, Breaker failure, Cold load pick-up, Earth fault, directional earth fault, Negative sequence overvoltage, Lockout, Under voltage, Overvoltage, Rate of change of frequency, Neutral voltage displacement, Thermal overload protection, Under frequency, Over frequency, Phase undercurrent, Earth fault watt metric, Synchro-check, Voltage restrained over current with following technical description complet all as specified and directed by Engineer-in-Charge:- (i) 5 current input CT....C/5 A & X/1 A, 16 discrete, 3...4 voltage (ii) 16 discrete output (iii) Communication part protocol, Ethernet, IEC 6185, Mdbus RTU, DNP3, IEC 60870-5-103 (iv) Aux & Rated supply 110..... 250 V DC (v) CB/ Contactor based control and monitoring control (vi) Fault, Event & Disturbance recording (vii) Trip ckt, CT/VT Supervision. (viii) RS-232, fibre optic & RS 485 communication port facility. Make Micom P141/ ABB REF 615/ SIEMENS 7SR 804/ASHIDA ADR 245 B.
M & L for maintenance & overhauling of 11 KV Capacitor Bank including opening, checking, cleaning with CRC, cleaning wiping of insulating components, primary & Secondary circuits, spouts, bus bars, supports, cleaning contact tips, cleaning of bushes, spout insulators for visible crack, tightness old fasteners holding moving contacts, fuse assemble, testing, cleaning & overhauling of complete operating mechanism for smooth functioning rectifying the defects including Deoxidizing of all electrical contacts replacement unserviceable wiring with ferrule & lugs, reassembling & testing of complete Capacitor Bank all as directed. Note :- (i) Required part for replacement will be measured and paid under relevant item as supply only. (ii) Cost of Labour & cleaning material like Urethane, Gasket remover, lubricant etc for replacement is deemed to be included under this item
Supply only in replacement fuse assembly for 11 KV Capacitor bank complete including Fuse of 40 Amps, Spring arrangement and testing of Capacitor bank complete.
M & L for supply including filling of SF-6 Gas in 132 KV circuit beaker upto level as per manufacturer's instructions and testing complete all as specified and directed by Engineer-in-Charge
Periodical checking of main transformer control panel of and control circuit of relays such as PRV Relay, main buccholz relay, differential relay, oil temp level, oil level etc upto Marshal box and power Transformer and necessary repair/ replacement of indicator, MCBs, lugs, Fuse, Tnc switch etc at control panel and testing complete all as specified and directed by Engineer-in-Charge.
Periodical maint of yard equipment such as cleaning of insulators, greasing of isolator links, cleaning of capacitor bank bus bar and yard etc complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of HRC fuse 4 A to 32 A suitable for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge
M & L in replacement of HRC fuse 40 A to 63A suitable for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge
M & L for repair of unserviceable oil level indicator gauge in conservator chamber of T3 transformer 132/11 KV including repair/ replacement of float valve, indicator guage etc and draining out conservator Chamber Transformer oil and refilling same after dehydration complete as per laid down procedure for power transformer handling complete all as specified and directed by Engineer-in-Charge
The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ
M/s Kataria Construction Company
GILL ENTERPRISES
SS CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .